Xiaoyang Dong
Xiaoyang Dong has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Chen Liang
Electric Power Research Institute, State Grid Gansu Electric Power Company, Lanzhou 730050, China
2 shared publications - Xiping Ma
Electric Power Research Institute, State Grid Gansu Electric Power Company, Lanzhou 730070, China
2 shared publications - Chen Liang
Electric Power Research Institute, State Grid Gansu Electric Power Company, Lanzhou 730050, China
1 shared publication - Haodong Du
School of Electrical Engineering, Xi’an University of Technology, Xi’an 710048, China
1 shared publication - Man Ding
School of Electrical Engineering, Xi’an University of Technology, Xi’an 710048, China
1 shared publication - Rong Jia
School of Electrical Engineering, Xi’an University of Technology, Xi’an 710054, China
1 shared publication
Latest Publications
- Open Access
Economic Dispatch of AC/DC Power System Considering Thermal Dynamics
Advance in renewable penetration has promoted the interaction between the AC and DC power system and multi-energy sources. However, the disparate nature of different energy utilization technologies presents strong challenges for the economic dispatch of such a complex system. This paper proposes a comprehensive characterization of the AC/DC power system considering multi-energy and renewable integration. Detailed models are elaborated for the AC/DC power grid, the district heating system (DHS), coupling units, and renewables to describe their inner interactions accurately. On this basis, an economic dispatch method is developed to minimize the operation cost and renewable’s abandonment. Simulations indicate that the interaction between the AC/DC power systems and multi-energy sources can enhance voltage levels and improve operational economy.
Open AccessEconomic Dispatch of AC/DC Power System Considering Thermal Dynamics
Advance in renewable penetration has promoted the interaction between the AC and DC power system and multi-energy sources. However, the disparate nature of different energy utilization technologies presents strong challenges for the economic dispatch of such a complex system. This paper proposes a comprehensive characterization of the AC/DC power system considering multi-energy and renewable integration. Detailed models are elaborated for the AC/DC power grid, the district heating system (DHS), coupling units, and renewables to describe their inner interactions accurately. On this basis, an economic dispatch method is developed to minimize the operation cost and renewable’s abandonment. Simulations indicate that the interaction between the AC/DC power systems and multi-energy sources can enhance voltage levels and improve operational economy.
- Open Access
- 11 October 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (20) , 12975
Study of Transformer Harmonic Loss Characteristic in Distribution Network Based on Field-Circuit Coupling Method
One of the primary causes of additional losses in dry-type distribution transformers is harmonic disturbances in the distribution network. It is critical to investigate the change law of trans-former losses under harmonic conditions. The effect of harmonics on transformer core losses and winding losses is first investigated in this paper. The field-circuit coupling method is then used to create a finite element model of a three-phase phase dry type distribution transformer. Finally, the relationship between core loss and harmonic voltage, winding loss and harmonic current is calculated and analyzed for each harmonic frequency. The AC resistance factor model is found to be more accurate than the conventional model in calculating transformer harmonic winding losses. This paper’s findings have significant theoretical implications for the analysis of harmonic losses and loss reduction in distribution networks.
- 11 October 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (20) , 12975
Open AccessStudy of Transformer Harmonic Loss Characteristic in Distribution Network Based on Field-Circuit Coupling Method
One of the primary causes of additional losses in dry-type distribution transformers is harmonic disturbances in the distribution network. It is critical to investigate the change law of trans-former losses under harmonic conditions. The effect of harmonics on transformer core losses and winding losses is first investigated in this paper. The field-circuit coupling method is then used to create a finite element model of a three-phase phase dry type distribution transformer. Finally, the relationship between core loss and harmonic voltage, winding loss and harmonic current is calculated and analyzed for each harmonic frequency. The AC resistance factor model is found to be more accurate than the conventional model in calculating transformer harmonic winding losses. This paper’s findings have significant theoretical implications for the analysis of harmonic losses and loss reduction in distribution networks.