Geumbee Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Geumbee Lee has a total of 121 co-authors. Here are the top co-authors by number of shared publications:
- Hong-Joon Yoon
Department of Semiconductor Engineering, Gachon University, Seongnam 13120, Republic of Korea
4 shared publications - John Allen Rogers
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, 60208, USA
4 shared publications - Hak-Young Ahn
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
3 shared publications - Hanjun Ryu
Department of Advanced Materials Engineering, Chung-Ang University, Anseong-si 17546, Gyeonggi-do, Republic of Korea
3 shared publications - John A. Rogers
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
3 shared publications - Sung Soo Kwak
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208
3 shared publications
Latest Publications
- Open Access
- 18 December 2025
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (13)
A Bioresorbable Neural Interface for On‐Demand Thermal Pain Block
Conventional strategies for the management of acute pain have significant limitations. Pharmaceutical approaches carry risks for addiction and misuse. Standard implantable devices require secondary surgeries for removal and physical tethers to external systems for power and control. Recent work on bioresorbable electrical stimulators overcomes certain of these drawbacks, but existing versions still depend on transcutaneous leads. Here, we introduce a platform that employs thermal mechanisms for nerve block to bypass some of these limitations. The system integrates both a Joule heating element and a resistive temperature sensor in a soft cuff structure as a nerve interface, in which most of the materials are bioresorbable over a clinically relevant timeframe. This design enables precise control of nerve temperature within a safe range (≤45°C) for effective nerve block through a feedback‐guided strategy that continuously monitors temperature and adjusts current in real time. Options for wireless power delivery eliminate the need for external interfaces. Small animal model studies confirm the reversible and non‐invasive operation of this system. The results demonstrate effective suppression of compound nerve action potentials in response to thermal stimulation, with recovery of nerve conduction upon cooling. These findings highlight the potential of this platform as a safe and effective solution to acute pain management.
- 18 December 2025
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (13)
Open AccessA Bioresorbable Neural Interface for On‐Demand Thermal Pain Block
Conventional strategies for the management of acute pain have significant limitations. Pharmaceutical approaches carry risks for addiction and misuse. Standard implantable devices require secondary surgeries for removal and physical tethers to external systems for power and control. Recent work on bioresorbable electrical stimulators overcomes certain of these drawbacks, but existing versions still depend on transcutaneous leads. Here, we introduce a platform that employs thermal mechanisms for nerve block to bypass some of these limitations. The system integrates both a Joule heating element and a resistive temperature sensor in a soft cuff structure as a nerve interface, in which most of the materials are bioresorbable over a clinically relevant timeframe. This design enables precise control of nerve temperature within a safe range (≤45°C) for effective nerve block through a feedback‐guided strategy that continuously monitors temperature and adjusts current in real time. Options for wireless power delivery eliminate the need for external interfaces. Small animal model studies confirm the reversible and non‐invasive operation of this system. The results demonstrate effective suppression of compound nerve action potentials in response to thermal stimulation, with recovery of nerve conduction upon cooling. These findings highlight the potential of this platform as a safe and effective solution to acute pain management.
- Open Access
- 25 June 2023
- Published by Wiley in Advanced Science
- Vol. 11 (27) , e2301232
Implantable, Bioresorbable Radio Frequency Resonant Circuits for Magnetic Resonance Imaging
Magnetic resonance imaging (MRI) is widely used in clinical care and medical research. The signal‐to‐noise ratio (SNR) in the measurement affects parameters that determine the diagnostic value of the image, such as the spatial resolution, contrast, and scan time. Surgically implanted radiofrequency coils can increase SNR of subsequent MRI studies of adjacent tissues. The resulting benefits in SNR are, however, balanced by significant risks associated with surgically removing these coils or with leaving them in place permanently. As an alternative, here the authors report classes of implantable inductor–capacitor circuits made entirely of bioresorbable organic and inorganic materials. Engineering choices for the designs of an inductor and a capacitor provide the ability to select the resonant frequency of the devices to meet MRI specifications (e.g., 200 MHz at 4.7 T MRI). Such devices enhance the SNR and improve the associated imaging capabilities. These simple, small bioelectronic systems function over clinically relevant time frames (up to 1 month) at physiological conditions and then disappear completely by natural mechanisms of bioresorption, thereby eliminating the need for surgical extraction. Imaging demonstrations in a nerve phantom and a human cadaver suggest that this technology has broad potential for post‐surgical monitoring/evaluation of recovery processes.
- 25 June 2023
- Published by Wiley in Advanced Science
- Vol. 11 (27) , e2301232
Open AccessImplantable, Bioresorbable Radio Frequency Resonant Circuits for Magnetic Resonance Imaging
Magnetic resonance imaging (MRI) is widely used in clinical care and medical research. The signal‐to‐noise ratio (SNR) in the measurement affects parameters that determine the diagnostic value of the image, such as the spatial resolution, contrast, and scan time. Surgically implanted radiofrequency coils can increase SNR of subsequent MRI studies of adjacent tissues. The resulting benefits in SNR are, however, balanced by significant risks associated with surgically removing these coils or with leaving them in place permanently. As an alternative, here the authors report classes of implantable inductor–capacitor circuits made entirely of bioresorbable organic and inorganic materials. Engineering choices for the designs of an inductor and a capacitor provide the ability to select the resonant frequency of the devices to meet MRI specifications (e.g., 200 MHz at 4.7 T MRI). Such devices enhance the SNR and improve the associated imaging capabilities. These simple, small bioelectronic systems function over clinically relevant time frames (up to 1 month) at physiological conditions and then disappear completely by natural mechanisms of bioresorption, thereby eliminating the need for surgical extraction. Imaging demonstrations in a nerve phantom and a human cadaver suggest that this technology has broad potential for post‐surgical monitoring/evaluation of recovery processes.
- Top Cited Papers
- 24 February 2023
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 9 (8) , eade4687
Bioresorbable, wireless, and battery-free system for electrotherapy and impedance sensing at wound sites
Chronic wounds, particularly those associated with diabetes mellitus, represent a growing threat to public health, with additional notable economic impacts. Inflammation associated with these wounds leads to abnormalities in endogenous electrical signals that impede the migration of keratinocytes needed to support the healing process. This observation motivates the treatment of chronic wounds with electrical stimulation therapy, but practical engineering challenges, difficulties in removing stimulation hardware from the wound site, and absence of means to monitor the healing process create barriers to widespread clinical use. Here, we demonstrate a miniaturized wireless, battery-free bioresorbable electrotherapy system that overcomes these challenges. Studies based on a splinted diabetic mouse wound model confirm the efficacy for accelerated wound closure by guiding epithelial migration, modulating inflammation, and promoting vasculogenesis. Changes in the impedance provide means for tracking the healing process. The results demonstrate a simple and effective platform for wound site electrotherapy.
- 24 February 2023
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 9 (8) , eade4687
Top Cited PapersBioresorbable, wireless, and battery-free system for electrotherapy and impedance sensing at wound sites
Chronic wounds, particularly those associated with diabetes mellitus, represent a growing threat to public health, with additional notable economic impacts. Inflammation associated with these wounds leads to abnormalities in endogenous electrical signals that impede the migration of keratinocytes needed to support the healing process. This observation motivates the treatment of chronic wounds with electrical stimulation therapy, but practical engineering challenges, difficulties in removing stimulation hardware from the wound site, and absence of means to monitor the healing process create barriers to widespread clinical use. Here, we demonstrate a miniaturized wireless, battery-free bioresorbable electrotherapy system that overcomes these challenges. Studies based on a splinted diabetic mouse wound model confirm the efficacy for accelerated wound closure by guiding epithelial migration, modulating inflammation, and promoting vasculogenesis. Changes in the impedance provide means for tracking the healing process. The results demonstrate a simple and effective platform for wound site electrotherapy.
- Open Access
- 23 December 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (51) , eade3201
Biodegradable, three-dimensional colorimetric fliers for environmental monitoring
Recently reported winged microelectronic systems offer passive flight mechanisms as a dispersal strategy for purposes in environmental monitoring, population surveillance, pathogen tracking, and other applications. Initial studies indicate potential for technologies of this type, but advances in structural and responsive materials and in aerodynamically optimized geometries are necessary to improve the functionality and expand the modes of operation. Here, we introduce environmentally degradable materials as the basis of 3D fliers that allow remote, colorimetric assessments of multiple environmental parameters—pH, heavy metal concentrations, and ultraviolet exposure, along with humidity levels and temperature. Experimental and theoretical investigations of the aerodynamics of these systems reveal design considerations that include not only the geometries of the structures but also their mass distributions across a range of bioinspired designs. Preliminary field studies that rely on drones for deployment and for remote colorimetric analysis by machine learning interpretation of digital images illustrate scenarios for practical use.
- 23 December 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (51) , eade3201
Open AccessBiodegradable, three-dimensional colorimetric fliers for environmental monitoring
Recently reported winged microelectronic systems offer passive flight mechanisms as a dispersal strategy for purposes in environmental monitoring, population surveillance, pathogen tracking, and other applications. Initial studies indicate potential for technologies of this type, but advances in structural and responsive materials and in aerodynamically optimized geometries are necessary to improve the functionality and expand the modes of operation. Here, we introduce environmentally degradable materials as the basis of 3D fliers that allow remote, colorimetric assessments of multiple environmental parameters—pH, heavy metal concentrations, and ultraviolet exposure, along with humidity levels and temperature. Experimental and theoretical investigations of the aerodynamics of these systems reveal design considerations that include not only the geometries of the structures but also their mass distributions across a range of bioinspired designs. Preliminary field studies that rely on drones for deployment and for remote colorimetric analysis by machine learning interpretation of digital images illustrate scenarios for practical use.
- Open Access
- 18 November 2022
- Published by Wiley in Advanced Healthcare Materials
- Vol. 12 (4) , e2202021
Wireless, Soft Sensors of Skin Hydration with Designs Optimized for Rapid, Accurate Diagnostics of Dermatological Health
Accurate measurements of skin hydration are of great interest to dermatological science and clinical practice. This parameter serves as a relevant surrogate of skin barrier function, a key representative benchmark for overall skin health. The skin hydration sensor (SHS) is a soft, skin‐interfaced wireless system that exploits a thermal measurement method, as an alternative to conventional impedance‐based hand‐held probes. This study presents multiple strategies for maximizing the sensitivity and reliability of this previously reported SHS platform. An in‐depth analysis of the thermal physics of the measurement process serves as the basis for structural optimizations of the electronics and the interface to the skin. Additional engineering advances eliminate variabilities associated with manual use of the device and with protocols for the measurement. The cumulative effect is an improvement in sensitivity by 135% and in repeatability by 36% over previously reported results. Pilot trials on more than 200 patients in a dermatology clinic validate the practical utility of the sensor for fast, reliable measurements.
- 18 November 2022
- Published by Wiley in Advanced Healthcare Materials
- Vol. 12 (4) , e2202021
Open AccessWireless, Soft Sensors of Skin Hydration with Designs Optimized for Rapid, Accurate Diagnostics of Dermatological Health
Accurate measurements of skin hydration are of great interest to dermatological science and clinical practice. This parameter serves as a relevant surrogate of skin barrier function, a key representative benchmark for overall skin health. The skin hydration sensor (SHS) is a soft, skin‐interfaced wireless system that exploits a thermal measurement method, as an alternative to conventional impedance‐based hand‐held probes. This study presents multiple strategies for maximizing the sensitivity and reliability of this previously reported SHS platform. An in‐depth analysis of the thermal physics of the measurement process serves as the basis for structural optimizations of the electronics and the interface to the skin. Additional engineering advances eliminate variabilities associated with manual use of the device and with protocols for the measurement. The cumulative effect is an improvement in sensitivity by 135% and in repeatability by 36% over previously reported results. Pilot trials on more than 200 patients in a dermatology clinic validate the practical utility of the sensor for fast, reliable measurements.
- Top Cited PapersOpen Access
- 7 October 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (40) , eabp9169
A bioresorbable peripheral nerve stimulator for electronic pain block
Local electrical stimulation of peripheral nerves can block the propagation of action potentials, as an attractive alternative to pharmacological agents for the treatment of acute pain. Traditional hardware for such purposes, however, involves interfaces that can damage nerve tissue and, when used for temporary pain relief, that impose costs and risks due to requirements for surgical extraction after a period of need. Here, we introduce a bioresorbable nerve stimulator that enables electrical nerve block and associated pain mitigation without these drawbacks. This platform combines a collection of bioresorbable materials in architectures that support stable blocking with minimal adverse mechanical, electrical, or biochemical effects. Optimized designs ensure that the device disappears harmlessly in the body after a desired period of use. Studies in live animal models illustrate capabilities for complete nerve block and other key features of the technology. In certain clinically relevant scenarios, such approaches may reduce or eliminate the need for use of highly addictive drugs such as opioids.
- 7 October 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (40) , eabp9169
Top Cited PapersOpen AccessA bioresorbable peripheral nerve stimulator for electronic pain block
Local electrical stimulation of peripheral nerves can block the propagation of action potentials, as an attractive alternative to pharmacological agents for the treatment of acute pain. Traditional hardware for such purposes, however, involves interfaces that can damage nerve tissue and, when used for temporary pain relief, that impose costs and risks due to requirements for surgical extraction after a period of need. Here, we introduce a bioresorbable nerve stimulator that enables electrical nerve block and associated pain mitigation without these drawbacks. This platform combines a collection of bioresorbable materials in architectures that support stable blocking with minimal adverse mechanical, electrical, or biochemical effects. Optimized designs ensure that the device disappears harmlessly in the body after a desired period of use. Studies in live animal models illustrate capabilities for complete nerve block and other key features of the technology. In certain clinically relevant scenarios, such approaches may reduce or eliminate the need for use of highly addictive drugs such as opioids.
- Open Access
- 12 January 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1
Author Correction: Stretchable, dynamic covalent polymers for soft, long-lived bioresorbable electronic stimulators designed to facilitate neuromuscular regeneration
A Correction to this paper has been published: https://doi.org/10.1038/s41467-020-20857-y
- 12 January 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1
Open AccessAuthor Correction: Stretchable, dynamic covalent polymers for soft, long-lived bioresorbable electronic stimulators designed to facilitate neuromuscular regeneration
A Correction to this paper has been published: https://doi.org/10.1038/s41467-020-20857-y