Philippe Piquet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Philippe Piquet has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Mariangela De Masi
Timone Aortic Center, Department of Vascular Surgery, APHM, Timone Hospital, 13005 Marseille, France
5 shared publications - Marine Gaudry
Timone Aortic Center, Department of Vascular Surgery, APHM, Timone Hospital, 13005 Marseille, France
5 shared publications - Alexis Jacquier
Radiology Department, University Hospital of Marseille, AP-HM , Marseille
4 shared publications - Carine Guivier-Curien
IRPHE UMR7342 Aix Marseille Université, CNRS, Centrale Méditerranée Marseille France
4 shared publications - Valérie Deplano
Aix Marseille Univ, CNRS, IRPHE, UMR7342, 13013 Marseille, France
4 shared publications - Laurence Bal
Timone Aortic Center, Department of Vascular Surgery, APHM, Timone Hospital, 13005 Marseille, France
3 shared publications
Latest Publications
- Open Access
- 21 August 2025
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 15 (8) , 393
Geometric Aortic Remodeling and Stent-Graft Migration After TEVAR: Insights from Longitudinal 3D Analysis and Literature Review
Background: Long-term follow-up after endovascular aortic repair (TEVAR) is crucial to detect adverse aortic remodeling, even with modern stent grafts offering enhanced flexibility and durability. Conventional imaging, based on diameter measurements, may fail to identify complications such as endograft migration. Methods: We conducted a longitudinal 3D geometric analysis of thoracic aortic and stent-graft evolution over 10 years in a patient treated for descending thoracic aortic aneurysm (DTAA) by endovascular treatment. A three-dimensional morphological analysis (length, tortuosity, angulation, and diameter) was carried out using advanced imaging software (EndoSize, MATLAB) to track aortic geometry and stent-graft behavior over time. A focused review of the literature on stent-graft migration, its risk factors, complications, and surveillance strategies was also performed. Results: This case illustrates how progressive geometric remodeling—including aortic elongation and increased tortuosity—can lead to delayed stent-graft migration and late type III endoleaks, with an elevated risk of rupture. The 3D analysis revealed early morphological changes that were undetectable using standard diameter-based follow-up. These observations are consistent with published data showing higher migration rates over time, particularly in tortuous anatomies. The literature review further emphasizes the clinical relevance of geometric surveillance, given the high rates of reintervention, morbidity, and mortality associated with stent-graft migration. Conclusions: This study underlines the importance of personalized and geometry-based surveillance after TEVAR. Advanced morphological assessment tools provide valuable insights for the early detection of complications and tailored patient management. Their integration into routine follow-up could help optimize long-term outcomes and prevent life-threatening events such as rupture.
- 21 August 2025
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 15 (8) , 393
Open AccessGeometric Aortic Remodeling and Stent-Graft Migration After TEVAR: Insights from Longitudinal 3D Analysis and Literature Review
Background: Long-term follow-up after endovascular aortic repair (TEVAR) is crucial to detect adverse aortic remodeling, even with modern stent grafts offering enhanced flexibility and durability. Conventional imaging, based on diameter measurements, may fail to identify complications such as endograft migration. Methods: We conducted a longitudinal 3D geometric analysis of thoracic aortic and stent-graft evolution over 10 years in a patient treated for descending thoracic aortic aneurysm (DTAA) by endovascular treatment. A three-dimensional morphological analysis (length, tortuosity, angulation, and diameter) was carried out using advanced imaging software (EndoSize, MATLAB) to track aortic geometry and stent-graft behavior over time. A focused review of the literature on stent-graft migration, its risk factors, complications, and surveillance strategies was also performed. Results: This case illustrates how progressive geometric remodeling—including aortic elongation and increased tortuosity—can lead to delayed stent-graft migration and late type III endoleaks, with an elevated risk of rupture. The 3D analysis revealed early morphological changes that were undetectable using standard diameter-based follow-up. These observations are consistent with published data showing higher migration rates over time, particularly in tortuous anatomies. The literature review further emphasizes the clinical relevance of geometric surveillance, given the high rates of reintervention, morbidity, and mortality associated with stent-graft migration. Conclusions: This study underlines the importance of personalized and geometry-based surveillance after TEVAR. Advanced morphological assessment tools provide valuable insights for the early detection of complications and tailored patient management. Their integration into routine follow-up could help optimize long-term outcomes and prevent life-threatening events such as rupture.
- Open Access
- 24 March 2025
- Published by MDPI AG in Preprints.org
Case Analyzes for Late Endograft Migration After Tevar Using a Special Software and a Literature Review
Post-TEVAR (thoracic endovascular aortic repair) follow-up is essential to monitor adverse aortic remodeling, despite technological advancements in stent grafts regarding their flexibility and durability. This article, along with the study of a clinical case over 10 years, explores the use of 3D morphological analysis and shows how type III endoleaks can drastically alter the morphology of the aorta. The literature review was to report the cumulative incidence of endograft migration as well as the morbidity, reintervention rates, and mortality related to endograft migration, to justify the importance of close standardized surveillance after TEVAR.
- 24 March 2025
- Published by MDPI AG in Preprints.org
Open AccessCase Analyzes for Late Endograft Migration After Tevar Using a Special Software and a Literature Review
Post-TEVAR (thoracic endovascular aortic repair) follow-up is essential to monitor adverse aortic remodeling, despite technological advancements in stent grafts regarding their flexibility and durability. This article, along with the study of a clinical case over 10 years, explores the use of 3D morphological analysis and shows how type III endoleaks can drastically alter the morphology of the aorta. The literature review was to report the cumulative incidence of endograft migration as well as the morbidity, reintervention rates, and mortality related to endograft migration, to justify the importance of close standardized surveillance after TEVAR.
- Open Access
- 18 May 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (10) , 2981
The Value of Aortic Volume and Intraluminal Thrombus Quantification for Predicting Aortic Events after Endovascular Thoracic Aneurysm Repair
Objectives: To assess the ability of the aortic aneurysm volume (AAV), aneurysmal lumen volume (ALV), and aneurysmal thrombus volume (ATV) to predict the need for aortic reintervention when using the maximal aortic diameter as a reference. Methods: This monocentric retrospective study included 31 consecutive patients who underwent successful thoracic endovascular aortic repair (TEVAR) to treat an atheromatous thoracic aortic aneurysm. All patients underwent clinical and computed tomography angiography (CTA) for 3 years after TEVAR. The patients were categorized into group 0 if no aortic reintervention was required during the follow-up period and categorized into group 1 if they experienced a type I or III endoleak or aneurysm diameter increase requiring intervention. The maximum aneurysm sac diameter and the AAV, ALV, and ATV were calculated using CTA images obtained preoperatively (T0) and at 6–12 months (T1), 24 months (T2), and 36 months (T3) postoperatively, and their changes over time were analyzed. Correlations between diameter and changes in AAV, ALV, and ATV were assessed, and the association between diameter and volume changes and reintervetion was examined. The cutoff values for predicting the need for reintervention was determined using a receiver operating characteristic (ROC) curve. The accuracy of volume change versus diameter change for predicting the need for reintervention was analyzed. Results: There were no significant differences in terms of the mean aneurysm diameter or AAV, ALV or ATV between the groups at preoperative CTA or after one year of follow-up imaging. The mean ATV was higher in group 1 than in group 0 at 2 years (187.6 ± 86.3 mL vs. 114.7 ± 64.7 mL; p = 0.057) and after 3 years (195.0 ± 86.7 mL vs. 82.1 ± 39.9 mL; p = 0.013). The maximal diameter was greater in group 1 than in group 0 at 3 years (67.3 ± 9.5 mm vs. 55.3 ± 12.6 mm; p = 0.044). The rate of AAV change between T0 and T1 was significantly higher in group 1 (7 ± 4.5%) than in group 0 (−6 ± 6.8%; p < 0.001). The rate of ATV change between T1-T3 was significantly higher in group 1 than in group 0 (34 ± 40.9% vs. −13 ± 14.4% (p = 0.041)); similar results were observed for the rate of ATV change between T2 and T3 (27 ± 50.1% for group 1 vs. −8 ± 49.5% in group 0 (p < 0.001)). According to our multivariate analysis, the annual growth rate for AAV between T0 and T1 was the only independent factor that was significantly associated with aortic reintervention (area under the curve (AUC) = 0.84, OR = 1.57, p = 0.025; optimal cutoff +0.4%). An increase in the annual growth rate of the ATV between T0 and T3 was independently associated with the need for aortic reintervention (area under the curve (AUC) = 0.90, OR = 1.11, p = 0.0347; optimal cutoff +10.1%). Conclusions: Aortic volume analysis can predict the need for aortic reintervention more accurately and earlier than maximal aortic diameter.
- 18 May 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (10) , 2981
Open AccessThe Value of Aortic Volume and Intraluminal Thrombus Quantification for Predicting Aortic Events after Endovascular Thoracic Aneurysm Repair
Objectives: To assess the ability of the aortic aneurysm volume (AAV), aneurysmal lumen volume (ALV), and aneurysmal thrombus volume (ATV) to predict the need for aortic reintervention when using the maximal aortic diameter as a reference. Methods: This monocentric retrospective study included 31 consecutive patients who underwent successful thoracic endovascular aortic repair (TEVAR) to treat an atheromatous thoracic aortic aneurysm. All patients underwent clinical and computed tomography angiography (CTA) for 3 years after TEVAR. The patients were categorized into group 0 if no aortic reintervention was required during the follow-up period and categorized into group 1 if they experienced a type I or III endoleak or aneurysm diameter increase requiring intervention. The maximum aneurysm sac diameter and the AAV, ALV, and ATV were calculated using CTA images obtained preoperatively (T0) and at 6–12 months (T1), 24 months (T2), and 36 months (T3) postoperatively, and their changes over time were analyzed. Correlations between diameter and changes in AAV, ALV, and ATV were assessed, and the association between diameter and volume changes and reintervetion was examined. The cutoff values for predicting the need for reintervention was determined using a receiver operating characteristic (ROC) curve. The accuracy of volume change versus diameter change for predicting the need for reintervention was analyzed. Results: There were no significant differences in terms of the mean aneurysm diameter or AAV, ALV or ATV between the groups at preoperative CTA or after one year of follow-up imaging. The mean ATV was higher in group 1 than in group 0 at 2 years (187.6 ± 86.3 mL vs. 114.7 ± 64.7 mL; p = 0.057) and after 3 years (195.0 ± 86.7 mL vs. 82.1 ± 39.9 mL; p = 0.013). The maximal diameter was greater in group 1 than in group 0 at 3 years (67.3 ± 9.5 mm vs. 55.3 ± 12.6 mm; p = 0.044). The rate of AAV change between T0 and T1 was significantly higher in group 1 (7 ± 4.5%) than in group 0 (−6 ± 6.8%; p < 0.001). The rate of ATV change between T1-T3 was significantly higher in group 1 than in group 0 (34 ± 40.9% vs. −13 ± 14.4% (p = 0.041)); similar results were observed for the rate of ATV change between T2 and T3 (27 ± 50.1% for group 1 vs. −8 ± 49.5% in group 0 (p < 0.001)). According to our multivariate analysis, the annual growth rate for AAV between T0 and T1 was the only independent factor that was significantly associated with aortic reintervention (area under the curve (AUC) = 0.84, OR = 1.57, p = 0.025; optimal cutoff +0.4%). An increase in the annual growth rate of the ATV between T0 and T3 was independently associated with the need for aortic reintervention (area under the curve (AUC) = 0.90, OR = 1.11, p = 0.0347; optimal cutoff +10.1%). Conclusions: Aortic volume analysis can predict the need for aortic reintervention more accurately and earlier than maximal aortic diameter.
- Open Access
- 29 June 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (13) , 4378
In Marfan Syndrome and Related Diseases, STABILISE Technique Should Be Used with Care: Results from a Volumetric Comparative Study of Endovascular Treatment for Aortic Dissection
Objectives: Aortic dissection in patients with Marfan and related syndromes (HTAD) is a serious pathology whose treatment by thoracic endovascular repair (TEVAR) is still under debate. The aim of this study was to assess the results of the TEVAR for aortic dissection in patients with HTAD as compared to a young population without HTAD. Methods: The study received the proper ethical oversight. We performed an observational exposed (confirmed HTAD) vs. non-exposed (p = 0.005. An increase in the whole aortic volume > 10% was observed in ten cases (58.8%) in the HTAD group and in five cases (22.7%) in the non-HTAD group (p = 0.022). FL thrombosis was achieved in nine cases (52.9%) in the HTAD group vs. twenty (90.9%) cases in the non-HTAD group (p < 0.01). The risk factors for unfavorable anatomical evolution were male gender and the STABILISE technique. With a linear model, we observed a significantly different aortic volume evolution between the two groups (p < 0.01) with the STABILISE technique; this statistical difference was not found in the TEVAR subgroup. In the HTAD patients, there was a significant difference in the total aortic volume evolution progression between the patients treated with the STABILISE technique and the patients treated with TEVAR (+160.1 ± 52.3% vs. +47 ± 22.5%, p < 0.01 and +189.5 ± 92.5% vs. +58.6 ± 34.8%, p < 0.01 at 1 year and at the end of follow-up, respectively). Conclusions: TEVAR in the HTAD patients seemed to be associated with poorer anatomical outcomes at 1 year. This result was strongly related to the STABILISE technique which should be considered with care in these specific patients.
- 29 June 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (13) , 4378
Open AccessIn Marfan Syndrome and Related Diseases, STABILISE Technique Should Be Used with Care: Results from a Volumetric Comparative Study of Endovascular Treatment for Aortic Dissection
Objectives: Aortic dissection in patients with Marfan and related syndromes (HTAD) is a serious pathology whose treatment by thoracic endovascular repair (TEVAR) is still under debate. The aim of this study was to assess the results of the TEVAR for aortic dissection in patients with HTAD as compared to a young population without HTAD. Methods: The study received the proper ethical oversight. We performed an observational exposed (confirmed HTAD) vs. non-exposed (p = 0.005. An increase in the whole aortic volume > 10% was observed in ten cases (58.8%) in the HTAD group and in five cases (22.7%) in the non-HTAD group (p = 0.022). FL thrombosis was achieved in nine cases (52.9%) in the HTAD group vs. twenty (90.9%) cases in the non-HTAD group (p < 0.01). The risk factors for unfavorable anatomical evolution were male gender and the STABILISE technique. With a linear model, we observed a significantly different aortic volume evolution between the two groups (p < 0.01) with the STABILISE technique; this statistical difference was not found in the TEVAR subgroup. In the HTAD patients, there was a significant difference in the total aortic volume evolution progression between the patients treated with the STABILISE technique and the patients treated with TEVAR (+160.1 ± 52.3% vs. +47 ± 22.5%, p < 0.01 and +189.5 ± 92.5% vs. +58.6 ± 34.8%, p < 0.01 at 1 year and at the end of follow-up, respectively). Conclusions: TEVAR in the HTAD patients seemed to be associated with poorer anatomical outcomes at 1 year. This result was strongly related to the STABILISE technique which should be considered with care in these specific patients.
- Open Access
- 12 October 2022
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 9 (10) , 349
Volume Analysis to Predict the Long-Term Evolution of Residual Aortic Dissection after Type A Repair
Background: The aim of this study was to evaluate the aortic diameter and volume during the first year after a type A repair to predict the long-term prognosis of a residual aortic dissection (RAD). Methods: All patients treated in our center for an acute type A dissection with a RAD and follow-up > 3 years were included. We defined two groups: group 1 with dissection-related events (defined as an aneurysmal evolution, distal reintervention, or aortic-related death) and group 2 without dissection-related events. The aortic diameters and volume analysis were evaluated on three postoperative CT scans: pre-discharge (T1), 3–6 months (T2) and 1 year (T3). Results: Between 2009 and 2016, 54 patients were included. Following a mean follow-up of 75.4 months (SD 31.5), the rate of dissection-related events was 62.9% (34/54). The total aortic diameters of the descending thoracic aorta were greater in group 1 at T1, T2 and T3, with greater diameters in the FL (p < 0.01). The aortic diameter evolution at 3 months was not predictive of long-term dissection-related events. The total thoracic aortic volume was significantly greater in group 1 at T1 (p < 0.01), T2 (p < 0.01), and T3 (p < 0.01). At 3 months, the increase in the FL volume was significantly greater in group 1 (p < 0.01) and was predictive for long-term dissection-related events. Conclusion: This study shows that an initial CT scan volume analysis coupled with another at 3 months is predictive for the long-term evolution in a RAD. Based on this finding, more aggressive treatment could be given at an earlier stage.
- 12 October 2022
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 9 (10) , 349
Open AccessVolume Analysis to Predict the Long-Term Evolution of Residual Aortic Dissection after Type A Repair
Background: The aim of this study was to evaluate the aortic diameter and volume during the first year after a type A repair to predict the long-term prognosis of a residual aortic dissection (RAD). Methods: All patients treated in our center for an acute type A dissection with a RAD and follow-up > 3 years were included. We defined two groups: group 1 with dissection-related events (defined as an aneurysmal evolution, distal reintervention, or aortic-related death) and group 2 without dissection-related events. The aortic diameters and volume analysis were evaluated on three postoperative CT scans: pre-discharge (T1), 3–6 months (T2) and 1 year (T3). Results: Between 2009 and 2016, 54 patients were included. Following a mean follow-up of 75.4 months (SD 31.5), the rate of dissection-related events was 62.9% (34/54). The total aortic diameters of the descending thoracic aorta were greater in group 1 at T1, T2 and T3, with greater diameters in the FL (p < 0.01). The aortic diameter evolution at 3 months was not predictive of long-term dissection-related events. The total thoracic aortic volume was significantly greater in group 1 at T1 (p < 0.01), T2 (p < 0.01), and T3 (p < 0.01). At 3 months, the increase in the FL volume was significantly greater in group 1 (p < 0.01) and was predictive for long-term dissection-related events. Conclusion: This study shows that an initial CT scan volume analysis coupled with another at 3 months is predictive for the long-term evolution in a RAD. Based on this finding, more aggressive treatment could be given at an earlier stage.
- 1 November 2006
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 20 (6) , 723-730
Emergency Treatment of Acute Rupture of the Descending Thoracic Aorta Using Endovascular Stent-Grafts
- 1 November 2006
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 20 (6) , 723-730
Emergency Treatment of Acute Rupture of the Descending Thoracic Aorta Using Endovascular Stent-Grafts
- 1 September 2004
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 40 (3) , 455-462
Minimally invasive retroperitoneal approach for the treatment of infrarenal aortic disease
- 1 September 2004
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 40 (3) , 455-462
Minimally invasive retroperitoneal approach for the treatment of infrarenal aortic disease