Megan N. Gerold
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Megan N. Gerold has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Erica D. Dawson
InDevR Inc., 6035 Longbow Drive, Suite 102, Boulder, CO 80301, USA
2 shared publications - Evan Toth
InDevR Inc., 6035 Longbow Dr, Suite 102, Boulder, CO 80301, USA
2 shared publications - Kathy L. Rowlen
InDevR Inc., 2100 Central Ave., Suite 106, Boulder, CO 80301, USA
2 shared publications - Rachel Yue Gao
InDevR Inc., 2100 Central Ave., Suite 106, Boulder, CO 80301, USA
2 shared publications - Amber W. Taylor
InDevR Inc., 2100 Central Ave., Suite 106, Boulder, CO 80301, USA
1 shared publication - Caitlin McCormick
InDevR Inc., 2100 Central Ave., Suite 106, Boulder, CO 80301, USA
1 shared publication
Latest Publications
- Open Access
Analytical Performance of a Multiplexed Microarray Assay for Rapid Identification and Quantification of a Multivalent mRNA Vaccine
MRNA vaccines were highly effective in response to the COVID-19 pandemic, making them an attractive platform to address cancers and other infectious diseases. Many new mRNA vaccines in development are multivalent, which represents a difficulty for the standard assays commonly used to characterize the critical quality attributes of monovalent formulations. Here, we present a multiplexed analytical tool with nucleic acid microarray technology using the VaxArray platform that measures the identity and quantity of mono- and multivalent mixtures of naked mRNA and mRNA encapsulated in lipid nanoparticle formulations in under 2 h without any additional preparation steps, such as extraction or RT-PCR. Using a quadrivalent mixture of encapsulated mRNA constructs that encode for four unique proteins in a vaccine formulation, the VaxArray mRNA assay was demonstrated to be highly specific for each mRNA with sensitivity < 1 µg/mL. The quantification of individual mRNAs within the lipid nanoparticle mixture resulted in a precision of ≤10% RSD and an accuracy of 100 ± 9%.
Open AccessAnalytical Performance of a Multiplexed Microarray Assay for Rapid Identification and Quantification of a Multivalent mRNA Vaccine
MRNA vaccines were highly effective in response to the COVID-19 pandemic, making them an attractive platform to address cancers and other infectious diseases. Many new mRNA vaccines in development are multivalent, which represents a difficulty for the standard assays commonly used to characterize the critical quality attributes of monovalent formulations. Here, we present a multiplexed analytical tool with nucleic acid microarray technology using the VaxArray platform that measures the identity and quantity of mono- and multivalent mixtures of naked mRNA and mRNA encapsulated in lipid nanoparticle formulations in under 2 h without any additional preparation steps, such as extraction or RT-PCR. Using a quadrivalent mixture of encapsulated mRNA constructs that encode for four unique proteins in a vaccine formulation, the VaxArray mRNA assay was demonstrated to be highly specific for each mRNA with sensitivity < 1 µg/mL. The quantification of individual mRNAs within the lipid nanoparticle mixture resulted in a precision of ≤10% RSD and an accuracy of 100 ± 9%.
- Open Access
Rapid Identity and Quantity CQA Test for Multivalent mRNA Drug Product Formulations
The COVID-19 pandemic highlighted mRNA as a promising platform for vaccines and therapeutics. Many of the analytical tools used to characterize the critical quality attributes of mRNA are inherently singleplex and are not necessarily optimal from a labor and cost perspective. Here, we demonstrate the feasibility of a multiplexed platform (VaxArray) for efficient identity verification and concentration determination for both monovalent and multivalent mRNA formulations. A model system comprising mRNA constructs for influenza hemagglutinin and neuraminidase was used to characterize the analytical performance metrics for a VaxArray mRNA assay. The assay presented herein had a time to result of less than 2 h, required no PCR-based amplification nor extraction of mRNA from lipid nanoparticles, and exhibited high construct specificity that enabled application to the bivalent mixture. The sensitivity for influenza hemagglutinin and neuraminidase mRNA was sub-µg/mL, which is vaccine-relevant, and the average accuracy (%recovery of a check standard) and precision were 104 ± 2% and 9 ± 2%, respectively.
Open AccessRapid Identity and Quantity CQA Test for Multivalent mRNA Drug Product Formulations
The COVID-19 pandemic highlighted mRNA as a promising platform for vaccines and therapeutics. Many of the analytical tools used to characterize the critical quality attributes of mRNA are inherently singleplex and are not necessarily optimal from a labor and cost perspective. Here, we demonstrate the feasibility of a multiplexed platform (VaxArray) for efficient identity verification and concentration determination for both monovalent and multivalent mRNA formulations. A model system comprising mRNA constructs for influenza hemagglutinin and neuraminidase was used to characterize the analytical performance metrics for a VaxArray mRNA assay. The assay presented herein had a time to result of less than 2 h, required no PCR-based amplification nor extraction of mRNA from lipid nanoparticles, and exhibited high construct specificity that enabled application to the bivalent mixture. The sensitivity for influenza hemagglutinin and neuraminidase mRNA was sub-µg/mL, which is vaccine-relevant, and the average accuracy (%recovery of a check standard) and precision were 104 ± 2% and 9 ± 2%, respectively.