Arya Rudi Nasution
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Arya Rudi Nasution has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Affandi Affandi
Universitas Muhammadiyah Sumatera Utara
2 shared publications - Rahmat Fauzi Siregar
Department of Electrical Engineering, Faculty of Engineering, Universitas Muhammadiyah Sumatera Utara
2 shared publications - Wawan Septiawan Damanik
Universitas Muhammadiyah Sumatera Utara
2 shared publications Adelia Febrina Br. Sembiring
Universitas Muhammadiyah Sumatera Utara
1 shared publication- Arfian Arif
Program Studi Teknik Elektro, Universitas Muhammadiyah Sumatera Utara, Medan, Indonesia
1 shared publication Jagodang Harahap
Teknologi Rekayasa Manufaktur, Jurusan Teknik Mesin, Politeknik Negeri Lhokseumawe
1 shared publication
Latest Publications
- Open Access
- 6 April 2026
- Published by Akademi Komunitas Negeri Aceh Barat in VOCATECH: Vocational Education and Technology Journal
- Vol. 8 (1) , 49-58
Numerical Analysis of Aerodynamic Load Characteristics and Pressure Distribution of NACA 4412 Airfoil in Vertical Wind Turbines
The performance of a wind turbine is largely determined by its blade design, which typically uses airfoil-shaped cross-sections to optimize aerodynamic efficiency. The NACA 4412 airfoil, known for its strong aerodynamic properties, is commonly employed in both aircraft wings and wind turbine blades. Research on this airfoil investigates its lift and drag coefficients under varying wind speeds (2 m/s to 8 m/s), using SolidWorks 2021 for simulations. Results show that higher wind speeds generally increase lift and drag coefficients, with the highest lift coefficient recorded at 6 m/s. However, at 8 m/s, the lift coefficient decreases, highlighting the sensitivity of aerodynamic performance to speed variations. Additionally, pressure distribution increases with speed, while speed distribution decreases. These findings emphasize the importance of speed variations in influencing the aerodynamic behavior of wind turbine blades. The speed variation on the NACA 4412 airfoil affects the lift coefficient, where the lift coefficient and drag coefficient values will increase at each speed, but at a speed of 8 m/s the lift coefficient and drag coefficient will decrease with a lift coefficient value of 1670314e+06 and a drag coefficient value of 7.857e+07. The highest lift coefficient value occurs at a flow speed of 6 m/s of 3.54769e+04, and the highest drag coefficient value occurs at a flow speed of 6 m/s of 2.606e+06.Keywords: Airfoil NACA 4412; CFD; Speed Variations; Lift Coefficient and Drag. AbstrakKinerja turbin angin sebagian besar ditentukan oleh desain bilahnya, yang biasanya menggunakan penampang berbentuk airfoil untuk mengoptimalkan efisiensi aerodinamis. Airfoil NACA 4412, yang dikenal karena sifat aerodinamisnya yang kuat, umumnya digunakan pada sayap pesawat dan bilah turbin angin. Penelitian pada airfoil ini menyelidiki koefisien gaya angkat dan gaya hambatnya dalam berbagai kecepatan angin (2 m/s hingga 8 m/s), menggunakan SolidWorks 2021 untuk simulasi. Hasil penelitian menunjukkan bahwa kecepatan angin yang lebih tinggi umumnya meningkatkan koefisien gaya angkat dan gaya hambat, dengan koefisien gaya angkat tertinggi tercatat pada 6 m/s. Namun, pada 8 m/s, koefisien gaya angkat menurun, yang menyoroti sensitivitas kinerja aerodinamis terhadap variasi kecepatan. Selain itu, distribusi tekanan meningkat seiring dengan kecepatan, sementara distribusi kecepatan menurun. Temuan ini menekankan pentingnya variasi kecepatan dalam memengaruhi perilaku aerodinamis bilah turbin angin. Variasi kecepatan pada airfoil NACA 4412 mempengaruhi koefisien gaya angkat, dimana nilai koefisien gaya angkat dan koefisien gaya hambat akan bertambah pada setiap kecepatan, namun pada kecepatan 8 m/s koefisien gaya angkat dan koefisien gaya hambat akan berkurang dengan nilai koefisien gaya angkat sebesar 1.670314e+06 dan nilai koefisien gaya hambat sebesar 7.857e+07. Nilai koefisien gaya angkat tertinggi terjadi pada kecepatan aliran 6 m/s sebesar 3.54769e+04, dan nilai koefisien gaya hambat tertinggi terjadi pada kecepatan aliran 6 m/s sebesar 2.606e+06.Kata Kunci : Airfoil NACA 4412; CFD; Variasi Kecepatan; Koefisien Angkat dan Hambatan.
- 6 April 2026
- Published by Akademi Komunitas Negeri Aceh Barat in VOCATECH: Vocational Education and Technology Journal
- Vol. 8 (1) , 49-58
Open AccessNumerical Analysis of Aerodynamic Load Characteristics and Pressure Distribution of NACA 4412 Airfoil in Vertical Wind Turbines
The performance of a wind turbine is largely determined by its blade design, which typically uses airfoil-shaped cross-sections to optimize aerodynamic efficiency. The NACA 4412 airfoil, known for its strong aerodynamic properties, is commonly employed in both aircraft wings and wind turbine blades. Research on this airfoil investigates its lift and drag coefficients under varying wind speeds (2 m/s to 8 m/s), using SolidWorks 2021 for simulations. Results show that higher wind speeds generally increase lift and drag coefficients, with the highest lift coefficient recorded at 6 m/s. However, at 8 m/s, the lift coefficient decreases, highlighting the sensitivity of aerodynamic performance to speed variations. Additionally, pressure distribution increases with speed, while speed distribution decreases. These findings emphasize the importance of speed variations in influencing the aerodynamic behavior of wind turbine blades. The speed variation on the NACA 4412 airfoil affects the lift coefficient, where the lift coefficient and drag coefficient values will increase at each speed, but at a speed of 8 m/s the lift coefficient and drag coefficient will decrease with a lift coefficient value of 1670314e+06 and a drag coefficient value of 7.857e+07. The highest lift coefficient value occurs at a flow speed of 6 m/s of 3.54769e+04, and the highest drag coefficient value occurs at a flow speed of 6 m/s of 2.606e+06.Keywords: Airfoil NACA 4412; CFD; Speed Variations; Lift Coefficient and Drag. AbstrakKinerja turbin angin sebagian besar ditentukan oleh desain bilahnya, yang biasanya menggunakan penampang berbentuk airfoil untuk mengoptimalkan efisiensi aerodinamis. Airfoil NACA 4412, yang dikenal karena sifat aerodinamisnya yang kuat, umumnya digunakan pada sayap pesawat dan bilah turbin angin. Penelitian pada airfoil ini menyelidiki koefisien gaya angkat dan gaya hambatnya dalam berbagai kecepatan angin (2 m/s hingga 8 m/s), menggunakan SolidWorks 2021 untuk simulasi. Hasil penelitian menunjukkan bahwa kecepatan angin yang lebih tinggi umumnya meningkatkan koefisien gaya angkat dan gaya hambat, dengan koefisien gaya angkat tertinggi tercatat pada 6 m/s. Namun, pada 8 m/s, koefisien gaya angkat menurun, yang menyoroti sensitivitas kinerja aerodinamis terhadap variasi kecepatan. Selain itu, distribusi tekanan meningkat seiring dengan kecepatan, sementara distribusi kecepatan menurun. Temuan ini menekankan pentingnya variasi kecepatan dalam memengaruhi perilaku aerodinamis bilah turbin angin. Variasi kecepatan pada airfoil NACA 4412 mempengaruhi koefisien gaya angkat, dimana nilai koefisien gaya angkat dan koefisien gaya hambat akan bertambah pada setiap kecepatan, namun pada kecepatan 8 m/s koefisien gaya angkat dan koefisien gaya hambat akan berkurang dengan nilai koefisien gaya angkat sebesar 1.670314e+06 dan nilai koefisien gaya hambat sebesar 7.857e+07. Nilai koefisien gaya angkat tertinggi terjadi pada kecepatan aliran 6 m/s sebesar 3.54769e+04, dan nilai koefisien gaya hambat tertinggi terjadi pada kecepatan aliran 6 m/s sebesar 2.606e+06.Kata Kunci : Airfoil NACA 4412; CFD; Variasi Kecepatan; Koefisien Angkat dan Hambatan.
- Open Access
- 22 September 2025
- Published by Jurnal Rekayasa Elektrika (JRE) in Jurnal Rekayasa Elektrika
- Vol. 21 (3)
Optimizing Light Detection with Photodiode Sensor Arrays using Linear Regression
Photodiode sensors are widely used in various applications such as light intensity measurement, optoelectronic devices, and automation. In improving the quality of measurement and automation systems, more sophisticated technology is needed such as photodiode sensor arrays, which allow more accurate data collection from multiple sensors simultaneously. This research aims to design a photodiode sensor array with high sensitivity. The system design consists of six photodiode sensors combined with a summing amplifier circuit and a non-inverting amplifier as a signal conditioner which is then processed by a microcontroller. After that, the linear regression function is determined through the calibration process and experiments carried out. Two linear regression functions are obtained and implemented in two operating modes: normal mode and sensitive mode. Experimental results yield two linear regression functions applied to a photodiode sensor array in normal and sensitive modes. Normal mode shows 82.50% accuracy with a 36.69% coefficient of variation, while sensitive mode boasts 94.05% accuracy and 49.81% coefficient of variation. Both modes cater to different light conditions, with sensitive mode excelling in detecting light intensity. Linear regression implementation proves precise and accurate for light detection.
- 22 September 2025
- Published by Jurnal Rekayasa Elektrika (JRE) in Jurnal Rekayasa Elektrika
- Vol. 21 (3)
Open AccessOptimizing Light Detection with Photodiode Sensor Arrays using Linear Regression
Photodiode sensors are widely used in various applications such as light intensity measurement, optoelectronic devices, and automation. In improving the quality of measurement and automation systems, more sophisticated technology is needed such as photodiode sensor arrays, which allow more accurate data collection from multiple sensors simultaneously. This research aims to design a photodiode sensor array with high sensitivity. The system design consists of six photodiode sensors combined with a summing amplifier circuit and a non-inverting amplifier as a signal conditioner which is then processed by a microcontroller. After that, the linear regression function is determined through the calibration process and experiments carried out. Two linear regression functions are obtained and implemented in two operating modes: normal mode and sensitive mode. Experimental results yield two linear regression functions applied to a photodiode sensor array in normal and sensitive modes. Normal mode shows 82.50% accuracy with a 36.69% coefficient of variation, while sensitive mode boasts 94.05% accuracy and 49.81% coefficient of variation. Both modes cater to different light conditions, with sensitive mode excelling in detecting light intensity. Linear regression implementation proves precise and accurate for light detection.
- Open Access
- 31 July 2023
- Published by Poltekkes Kemenkes Palu in Poltekita: Jurnal Pengabdian Masyarakat
- Vol. 4 (3) , 649-658
Penerapan Teknologi Skimming dan Bioremediation pada Instalasi Pengelolaan Air Limbah di PT. Waruna Shipyard Indonesia
Water pollution causes environmental damage and is very detrimental to living things. This activity aims to improve the performance of the Wastewater Management Installation (WWTP) which functions to reduce pollutant levels in the waters. Through the collaboration of the UMSU Faculty of Engineering with PT. Waruna Shipyrad Indonesia (WSI), collaboration was also carried out to improve the performance of the wastewater management system. Wastewater management methods are carried out by applying skimming machine technology, and several sensors for the physical properties and composition of water, as well as using remediation of good bacteria from the laboratory. 6 WWTP ponds were implemented, each with dimensions of 3.7x2.8x2.17 m. The skimming machine is designed to use a drum, and the bacteria from the remediation process will suppress the growth of bacteria that damage the environment. The volume of water entering the reservoir is around 207,200 kg/m3 perweek or 207.2 Liters/week. The results of applying this technology obtained an average amount of oil taken every 2 days reaching 600 mL. The average water quality is 6-8 with a pH standard of 6-9, a COD value of 47.8 mg/L with a quality standard of 100 mg/L, and a BOD value of 21.1 mg/L with a quality standard of 30 mg/L.
- 31 July 2023
- Published by Poltekkes Kemenkes Palu in Poltekita: Jurnal Pengabdian Masyarakat
- Vol. 4 (3) , 649-658
Open AccessPenerapan Teknologi Skimming dan Bioremediation pada Instalasi Pengelolaan Air Limbah di PT. Waruna Shipyard Indonesia
Water pollution causes environmental damage and is very detrimental to living things. This activity aims to improve the performance of the Wastewater Management Installation (WWTP) which functions to reduce pollutant levels in the waters. Through the collaboration of the UMSU Faculty of Engineering with PT. Waruna Shipyrad Indonesia (WSI), collaboration was also carried out to improve the performance of the wastewater management system. Wastewater management methods are carried out by applying skimming machine technology, and several sensors for the physical properties and composition of water, as well as using remediation of good bacteria from the laboratory. 6 WWTP ponds were implemented, each with dimensions of 3.7x2.8x2.17 m. The skimming machine is designed to use a drum, and the bacteria from the remediation process will suppress the growth of bacteria that damage the environment. The volume of water entering the reservoir is around 207,200 kg/m3 perweek or 207.2 Liters/week. The results of applying this technology obtained an average amount of oil taken every 2 days reaching 600 mL. The average water quality is 6-8 with a pH standard of 6-9, a COD value of 47.8 mg/L with a quality standard of 100 mg/L, and a BOD value of 21.1 mg/L with a quality standard of 30 mg/L.
- Open Access
- 11 October 2022
- Published by Indonesian Mechanical Engineering Cooperation Agency in Jurnal Teknik Mesin Indonesia
- Vol. 17 (2) , 12-20
Analisa numerik pengaruh diameter perforate terhadap perpindahan panas dan penurunan tekanan pada saluran segi empat 4:1 menggunakan perforated groove v- rib
Dalam saluran pendingin internal bilah turbin gas, struktur rusuk banyak digunakan untuk meningkatkan perpindahan panas konveksi dengan aliran pendingin yang melewati permukaan rusuk. Kajian ini berkonsentrasi pada V-rib berlubang dengan alur pada saluran pendingin dengan penampang persegi panjang. Kajian ini menganalisis perpindahan panas dan penurunan tekanan pada saluran segi empat dengan alur v-rib berlubang untuk memberikan solusi pendingin sudu turbin gas. Kajian ini dilakukan dengan analisis numerik. Beberapa model dibuat dan dianalisis menggunakan Solidworks Flow Simulation, sebuah komputasi dinamika fluida komersial (CFD) berdasarkan metode volume hingga. Solidworks Flow Simulation Solver untuk menganalisis aliran laminar dan turbulen menggunakan persamaan Reynolds rata-rata Navier-Stokes. Menggunakan persamaan transportasi yang sama untuk aliran laminar dan turbulen memberikan fleksibilitas. Turbulensi dalam aliran diperlakukan menggunakan energi kinetik turbulen (k) dan laju disipasi turbulensi (ꞷ) menggunakan model turbulensi k-ꞷ standar. Bilangan Reynolds 2000, 4000, 6000, 8000, 10000,12000,14000. Dengan memberikan panas 1000 Watt di bagian bawah saluran, kondisi udara pada suhu saluran masuk adalah 30 oC dan tekanan 1 atm. Pada rezim aliran 2000 < Re < 20.000, konstruksi rib berlubang secara signifikan meningkatkan angka Nusselt dibandingkan tanpa rib. Koefisien gesekan untuk konfigurasi rusuk padat lebih tinggi daripada rusuk berlubang.
- 11 October 2022
- Published by Indonesian Mechanical Engineering Cooperation Agency in Jurnal Teknik Mesin Indonesia
- Vol. 17 (2) , 12-20
Open AccessAnalisa numerik pengaruh diameter perforate terhadap perpindahan panas dan penurunan tekanan pada saluran segi empat 4:1 menggunakan perforated groove v- rib
Dalam saluran pendingin internal bilah turbin gas, struktur rusuk banyak digunakan untuk meningkatkan perpindahan panas konveksi dengan aliran pendingin yang melewati permukaan rusuk. Kajian ini berkonsentrasi pada V-rib berlubang dengan alur pada saluran pendingin dengan penampang persegi panjang. Kajian ini menganalisis perpindahan panas dan penurunan tekanan pada saluran segi empat dengan alur v-rib berlubang untuk memberikan solusi pendingin sudu turbin gas. Kajian ini dilakukan dengan analisis numerik. Beberapa model dibuat dan dianalisis menggunakan Solidworks Flow Simulation, sebuah komputasi dinamika fluida komersial (CFD) berdasarkan metode volume hingga. Solidworks Flow Simulation Solver untuk menganalisis aliran laminar dan turbulen menggunakan persamaan Reynolds rata-rata Navier-Stokes. Menggunakan persamaan transportasi yang sama untuk aliran laminar dan turbulen memberikan fleksibilitas. Turbulensi dalam aliran diperlakukan menggunakan energi kinetik turbulen (k) dan laju disipasi turbulensi (ꞷ) menggunakan model turbulensi k-ꞷ standar. Bilangan Reynolds 2000, 4000, 6000, 8000, 10000,12000,14000. Dengan memberikan panas 1000 Watt di bagian bawah saluran, kondisi udara pada suhu saluran masuk adalah 30 oC dan tekanan 1 atm. Pada rezim aliran 2000 < Re < 20.000, konstruksi rib berlubang secara signifikan meningkatkan angka Nusselt dibandingkan tanpa rib. Koefisien gesekan untuk konfigurasi rusuk padat lebih tinggi daripada rusuk berlubang.