XHXi Huang

Xi Huang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xi Huang has a total of 80 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Glancing-Angle Femtosecond Laser Polishing of Tantalum Carbide

    by Haoyu Dong, Luke Wadle, Zheyun Gu, Peizi Li, Xi Huang, Jean-Francois Silvain, Caillin Ryan, Patrick E. Albert, Xing Wang, Bai Cui, et al.

    Rapid, dimensionally accurate polishing of ultra-high-temperature ceramics remains difficult due to their hardness and brittleness, and how repeated ultrafast irradiation transforms a rough machined sidewall—and what limits further roughness reduction—is unclear. Glancing-angle femtosecond laser polishing of TaC in an ablation-dominated regime tracked morphological and chemical evolution with laser power and scan number. Roughness dropped rapidly as EDM topography was removed, then stabilized at 0.40–0.50 µm after a new sidewall formed. Raising power from 7.00 to 21.72 W reduced the scans needed for complete removal from 150 to 50; the lowest Sa of 0.400 µm was an 84.1% improvement over the initial EDM surface. Further scanning brought little additional smoothing but produced persistent 0.42–0.44 µm nanoripples of declining directional order and increased oxygen in the EDS sampling volume, while XPS showed a nearly constant Ta5+ fraction and O/Ta ratio, indicating a stable outermost oxide. Attainable roughness therefore reflects competition between fading EDM topography and growing laser-induced morphological and chemical modifications; a phenomenological model captured the two regimes and their transition. No microcracks were observed on the surface or in FIB cross-sections. The same approach reduced roughness of ZrB2 and cemented WC (BC-6S) by 77.2% and 74.4%, demonstrating versatility beyond TaC.

  • Open Access

    Characterizing laser-heated polymer foams with simultaneous x-ray fluorescence spectroscopy and Thomson scattering at the Matter in Extreme Conditions Endstation at LCLS

    by W. M. Martin, J. Nilsen, L. B. Fletcher, M. J. MacDonald, L. Andersen, A. Arnott, H. Bellenbaum, M. Böhme, N. Boiadjieva, N. Czapla, et al.

    Understanding the behavior of polymer foams at high energy density conditions is crucial to advance inertial fusion energy research. Here, we present a new experimental platform designed to measure the thermodynamic state of these materials at megabar pressures. At the Matter in Extreme Conditions Endstation of the Linac Coherent Light Source, we heat samples using an optical, high-intensity, femtosecond laser and dynamically probe them with ultra-short, coherent x-ray pulses of high peak brightness. We perform x-ray Thomson scattering measurements in forward and backward scattering geometries to capture both collective and non-collective electron behavior in the sample. Simultaneously, x-ray fluorescence spectroscopy is used to measure the emission from a mid-Z dopant, providing complementary information on the plasma conditions. By combining these techniques, we obtain temporally resolved temperature measurements of the transient warm dense matter states. Our initial experiments designed to benchmark the platform with carbon samples yielded data resolving the ultrafast response to laser heating with sub-picosecond resolution, measuring plasma temperatures exceeding 50 eV. These findings lay the foundation for precision studies of the dynamic evolution of laser-heated polymer foams.


  • Open Access

    Machine learning-assisted laser-induced breakdown spectroscopy for estimating substrate surface temperatures

    by Haoyu Dong, Xi Huang, Luke Wadle, Lanh Trinh, Peizi Li, Jean-Francois Silvain, Bai Cui, Yong-Feng Lu

    Laser-induced breakdown spectroscopy has been used for detecting substrate surface temperatures with the assistance of machine learning.


  • Time-resolved imaging of microscale dynamics in laser drying of silicon wafers

    by Zhipeng Wu, Xi Huang, Wanting Sun, Haoyu Dong, Aofei Mao, Bai Cui, Jean-François Silvain, Xinwei Wang, Yongfeng Lu


  • Enhance corrosion resistance of 304 stainless steel using nanosecond pulsed laser surface processing

    by Qiuchi Zhu, Wanting Sun, Yongchul Yoo, Xiang Zhang, Nicholas Hunter, Aofei Mao, Nan Li, Xi Huang, Peixun Fan, Xinwei Wang, et al.


  • Chemical element variation in fungi-induced coating degradation using laser-induced breakdown spectroscopy combined with Raman spectroscopy, mass spectrometry, and multivariate analyses

    by Xi Huang, Lei Liu, Yao Lu, Haoyu Dong, Aofei Mao, Peizi Li, Bai Cui, Jean-Francois Silvain, Yongfeng Lu

    Traditional coating products for hindering fungal growth are environmentally hazardous. As regulations become increasingly stringent, environmentally benign coating materials are becoming more prevalent. However, due to these new, lower-toxicity coating materials, the growth of mold, mildew, and other fungus begins to cause detrimental effects on materials. Thus, it is important to develop an understanding of the fungal survival and material degradation mechanisms of such low-toxicity coating materials. This study explored the fungal degradation mechanisms of coating materials by developing an approach combining laser-induced breakdown spectroscopy (LIBS), Raman spectroscopy, and mass spectrometry (MS). The coating systems tested in this study were MIL-PRF-23377, Type I, with chromate (class C) and non-chromate (class N). Aspergillus niger (A. niger) was used for fungal growth. The LIBS results indicate a chemical change/exchange (Mg, Ca, Ti, C, and N) during fungi-induced corrosion. In the Raman study, chemical bond changes at Raman peaks 748, 812, 976, 1006, 1041, 1184, and 1610 cm−1 were identified in the class N coatings after fungal growth. In the MS study, organic acids (oxalic and acetic) produced by fungi were detected. Based on the results, degradation mechanisms of non-Cr coating materials were proposed.


  • Gold-coated nanoripples produced by UV-Femtosecond lasers for surface enhanced Raman spectroscopy

    by Nan Li, Xi Huang, Haoyu Dong, Bin Duan, Qiuchi Zhu, Aofei Mao, Peizi Li, Bai Cui, Jean-Francois Silvain, Yongfeng Lu


  • Rapid nondestructive assessment of the degrees of sensitization of 5456 aluminum alloys using laser-induced breakdown spectroscopy (LIBS) with multivariate analysis

    by Lei Liu, Xi Huang, Haoyu Dong, Aofei Mao, Peizi Li, Bai Cui, Jean-Francois Silvain, Yongfeng Lu

    The 5xxx series aluminum (Al)–magnesium (Mg) alloys are extensively used in marine transportation and naval ships due to their high strength-to-weight ratios and great corrosion resistance properties. However, material degradation of the 5xxx alloys occurs over time after exposure to environments at elevated temperatures, referred to as sensitization. Sensitization is characterized by β-phase (Mg2Al3) precipitates along the grain boundaries, which increase the susceptibility to intergranular corrosion (IGC) and stress corrosion cracking (SCC). Therefore, it is important to assess the degree of sensitization (DoS) in modern naval ships, whose structures are primarily made of Al–Mg alloys, to determine whether they have reached a DoS threshold that may require maintenance or repair activities. In this study, laser-induced breakdown spectroscopy (LIBS) with statistical multivariate analysis methods was successfully developed to assess the DoS levels of the 5xxx alloys. LIBS measurements were conducted after chemical etching on 5456 Al–Mg alloy samples with DoS values of 7.1 (unsensitized), 20.2 (indeterminate), and 47.3 (sensitized) mg cm−2, respectively. The statistical multivariate analysis method of principal component and discriminant function analysis (PC-DFA) was used to process the LIBS spectra to establish a calibration model used for prediction of Al alloys with unknown DoS values. For each alloy sample, a total of 400 LIBS spectra were acquired. 350 of them were used to establish the calibration model by PC-DFA and the remaining 50 were used as unknown spectra for external validation of the model established. External validation of the established classification model shows accuracies of 100%, 100%, and 82%, respectively, for predicting tested Al alloy samples with unsensitized, indeterminate, and sensitized DoS values. Successful external validation of the classification model established by PC-DFA indicates the ability for sensitization assessment of 5456 Al alloys with unknown DoS values. The technology developed has the capability for rapid and non-destructive sensitization assessment on site.


  • Open Access

    SERS spectroscopy with machine learning to analyze human plasma derived sEVs for coronary artery disease diagnosis and prognosis

    by Xi Huang, Bo Liu, Shenghan Guo, Weihong Guo, Ke Liao, Guoku Hu, Wen Shi, Mitchell Kuss, Michael J. Duryee, Daniel R. Anderson, et al.

    Coronary artery disease (CAD) is one of the major cardiovascular diseases and represents the leading causes of global mortality. Developing new diagnostic and therapeutic approaches for CAD treatment are critically needed, especially for an early accurate CAD detection and further timely intervention. In this study, we successfully isolated human plasma small extracellular vesicles (sEVs) from four stages of CAD patients, that is, healthy control, stable plaque, non‐ST‐elevation myocardial infarction, and ST‐elevation myocardial infarction. Surface‐enhanced Raman scattering (SERS) measurement in conjunction with five machine learning approaches, including Quadratic Discriminant Analysis, Support Vector Machine (SVM), K‐Nearest Neighbor, Artificial Neural network, were then applied for the classification and prediction of the sEV samples. Among these five approaches, the overall accuracy of SVM shows the best predication results on both early CAD detection (86.4%) and overall prediction (92.3%). SVM also possesses the highest sensitivity (97.69%) and specificity (95.7%). Thus, our study demonstrates a promising strategy for noninvasive, safe, and high accurate diagnosis for CAD early detection.


  • Single and Multiwavelength All-Optical Clock Recovery Using Fabry–PÉrot Semiconductor Optical Amplifier

    by Fei Wang, Yu Yu, Xi Huang, Xinliang Zhang

    We experimentally demonstrate an all-optical clock recovery scheme for the return-to-zero data with single- and multiwavelength. This scheme is mainly based on clock-like pulse generation from an active filter with a multiquantum-well Fabry-Perot semiconductor optical amplifier and amplitude-equalization with self-nonlinear polarization switching. We obtain stable and low jitter optical clock signals in single and dual channels using this scheme, which has some distinct advantages including easy integration, free preamplification, convenient tuning, good tolerance to long ldquo0srdquo data, and greater tolerance to the stability of the input wavelength.