Tong Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tong Wang has a total of 102 co-authors. Here are the top co-authors by number of shared publications:
- Jing Liang
Institute of High Energy Physics
6 shared publications Xiaolong Wang
6 shared publicationsLan Dong
4 shared publicationsNa Ma
4 shared publicationsBo Li
3 shared publicationsLingling Men
3 shared publications
Latest Publications
- Open Access
- 1 July 2026
- Published by Elsevier in Superconductivity
- Vol. 19
The design, manufacture and vertical testing of 648 MHz 6-cell elliptical cavity for CSNS-II
- 1 July 2026
- Published by Elsevier in Superconductivity
- Vol. 19
Open AccessThe design, manufacture and vertical testing of 648 MHz 6-cell elliptical cavity for CSNS-II
- 5 June 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1091
A multi-sensor posterior weighting method for enhancing adjustment smoothness and the reliability of uncertainty evaluation in accelerator control networks
- 5 June 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1091
A multi-sensor posterior weighting method for enhancing adjustment smoothness and the reliability of uncertainty evaluation in accelerator control networks
- 1 June 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (6)
Curved neutron beam window for large vacuum chamber of neutron diffractometer
A curved large-area neutron beam window (NBW) has been designed for the large vacuum chamber of the high-resolution neutron diffractometer at the China Spallation Neutron Source. Compared with the conventional planar NBW, the curved structure can effectively reduce the deformation and stress, featuring a significantly longer lifetime and smaller thickness, which is crucial for improving the signal-noise ratio of diffraction data. Two prototypes of curved NBW with different thicknesses, 0.8 and 1.3 mm, were processed by high-speed milling, and the mechanical properties were studied by both strain gauges and x-ray stress analyzer. The experimental distribution of stress is in good consistency with the finite element analysis. Moreover, fatigue tests over 104 cycles of evacuation and venting demonstrate that the deformations of both prototypes are within the elastic region, which indicates a long life span. Therefore, this study reveals that the curved shape bears advantageous mechanical properties over the planar type for large and thin NBW.
- 1 June 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (6)
Curved neutron beam window for large vacuum chamber of neutron diffractometer
A curved large-area neutron beam window (NBW) has been designed for the large vacuum chamber of the high-resolution neutron diffractometer at the China Spallation Neutron Source. Compared with the conventional planar NBW, the curved structure can effectively reduce the deformation and stress, featuring a significantly longer lifetime and smaller thickness, which is crucial for improving the signal-noise ratio of diffraction data. Two prototypes of curved NBW with different thicknesses, 0.8 and 1.3 mm, were processed by high-speed milling, and the mechanical properties were studied by both strain gauges and x-ray stress analyzer. The experimental distribution of stress is in good consistency with the finite element analysis. Moreover, fatigue tests over 104 cycles of evacuation and venting demonstrate that the deformations of both prototypes are within the elastic region, which indicates a long life span. Therefore, this study reveals that the curved shape bears advantageous mechanical properties over the planar type for large and thin NBW.
- 10 April 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (4) , 045019
Research on accelerator tunnel network adjustment method based on minimum constraints
In the establishment of control networks for large-scale scientific facilities, this study focuses on the high energy photon source tunnel network, currently the largest light source in China. We explored the impact of ‘2 + 1’ dimensional (2 + 1D) and three-dimensional (3D) adjustment methods on the structure of control networks using two minimal constraint methods: fixed parameter and centroid datum. Firstly, the method of a posteriori variance component estimation (VCE) was adopted to address the impact of observed value weighting and approximate coordinates on the adjustment results, ensuring the reliability and uniqueness of these results. Secondly, through the adjustment analysis of the entire facility, as well as closed and non-closed loop networks, it was found that the deviation of the results in the horizontal between 2 + 1D adjustment and 3D adjustment is only 0.1 mm, demonstrating good consistency. However, in height, the 3D adjustment exhibits larger distortion, particularly in areas connected through small sight holes, where the distortion accumulates towards the distal end at each station. For the slender accelerator tunnel network, which is established through a free station setting and multi-station overlap, it is advisable to use 3D adjustment cautiously in the presence of structural weaknesses in the network shape.
- 10 April 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (4) , 045019
Research on accelerator tunnel network adjustment method based on minimum constraints
In the establishment of control networks for large-scale scientific facilities, this study focuses on the high energy photon source tunnel network, currently the largest light source in China. We explored the impact of ‘2 + 1’ dimensional (2 + 1D) and three-dimensional (3D) adjustment methods on the structure of control networks using two minimal constraint methods: fixed parameter and centroid datum. Firstly, the method of a posteriori variance component estimation (VCE) was adopted to address the impact of observed value weighting and approximate coordinates on the adjustment results, ensuring the reliability and uniqueness of these results. Secondly, through the adjustment analysis of the entire facility, as well as closed and non-closed loop networks, it was found that the deviation of the results in the horizontal between 2 + 1D adjustment and 3D adjustment is only 0.1 mm, demonstrating good consistency. However, in height, the 3D adjustment exhibits larger distortion, particularly in areas connected through small sight holes, where the distortion accumulates towards the distal end at each station. For the slender accelerator tunnel network, which is established through a free station setting and multi-station overlap, it is advisable to use 3D adjustment cautiously in the presence of structural weaknesses in the network shape.
- 5 March 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (3) , 035011
A close-up photogrammetry method with additional distance and angle observations for particle accelerators measurement and simulation experiments
Laser trackers or total stations are most widely used in particle accelerator measurement with high measurement accuracy but low efficiency. Close range photogrammetry has great characteristics of both high accuracy and efficiency, other than that, it enables non-contact observation, which is ideal for high-radiation accelerator measurement environments. In order to obtain the absolute position of the measurement area using close range photogrammetry, the position and orientation of the camera and the scale of the photo must be accurately determined at the moment of observation. A new three-dimensional visual measurement equipment is developed in this paper, which can obtain image, distance, and angle data at the same time. Unified adjustment of all three types of observations can more accurately determine position, orientation and scale datum. We used simulated data for experimental validation, comparing the new algorithm with another two algorithms: the traditional fixed point constraint and centroid datum constraint. The experiment results show that it can significantly improve positioning accuracy by adding distance and angle observations. The three-dimensional coordinate accuracy can reach up to 0.073 mm, while the accuracy of the other two algorithms can only be achieved 0.137 and 0.153 mm, the improvement is approximately 52.4%. Especially in the forward direction of the tunnel, the positioning accuracy is significantly improved, with an improvement of about 67.8 %.
- 5 March 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (3) , 035011
A close-up photogrammetry method with additional distance and angle observations for particle accelerators measurement and simulation experiments
Laser trackers or total stations are most widely used in particle accelerator measurement with high measurement accuracy but low efficiency. Close range photogrammetry has great characteristics of both high accuracy and efficiency, other than that, it enables non-contact observation, which is ideal for high-radiation accelerator measurement environments. In order to obtain the absolute position of the measurement area using close range photogrammetry, the position and orientation of the camera and the scale of the photo must be accurately determined at the moment of observation. A new three-dimensional visual measurement equipment is developed in this paper, which can obtain image, distance, and angle data at the same time. Unified adjustment of all three types of observations can more accurately determine position, orientation and scale datum. We used simulated data for experimental validation, comparing the new algorithm with another two algorithms: the traditional fixed point constraint and centroid datum constraint. The experiment results show that it can significantly improve positioning accuracy by adding distance and angle observations. The three-dimensional coordinate accuracy can reach up to 0.073 mm, while the accuracy of the other two algorithms can only be achieved 0.137 and 0.153 mm, the improvement is approximately 52.4%. Especially in the forward direction of the tunnel, the positioning accuracy is significantly improved, with an improvement of about 67.8 %.
- Open Access
- 1 March 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (3)
Universal adjustment model for visual photogrammetry and application in three-dimensional high-accuracy measurement of spatial targets
In order to meet the high-precision measurement requirements of point and line targets for particle accelerators, the visual photogrammetry system for three-dimensional measurement is proposed, and the data processing algorithm is investigated. First, based on the images collected by visual measurement, the pixel observations are converted into universal angle observations. An observation model for points based on angle observations is proposed, and the relation between angle observations and global coordinates is established. Then, a spatial straight line of a four-parameter expression method is proposed, and an offset observation model for the line is established. Finally, based on the principle of indirect adjustment, error equations are established, and an overall adjustment solution is achieved for point targets and line targets. Experimental results show that the coordinate component differences are within 25 μm for point targets when comparing the coordinates measured by this system with those measured by a three-coordinate machine. The differences for line targets are within 10 μm in the transverse direction but large in vertical, possibly due to the influence of the illumination. The universal adjustment method for three-dimensional visual measurement proposed in this paper extends the measurement capability from point targets to line targets, providing a comprehensive solution for both types of targets. This method can also be applied for the data processing of multi-system combination measurements of visual photogrammetry systems and laser trackers, leveraging the strengths of different measurement systems and having broad application prospects.
- 1 March 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (3)
Open AccessUniversal adjustment model for visual photogrammetry and application in three-dimensional high-accuracy measurement of spatial targets
In order to meet the high-precision measurement requirements of point and line targets for particle accelerators, the visual photogrammetry system for three-dimensional measurement is proposed, and the data processing algorithm is investigated. First, based on the images collected by visual measurement, the pixel observations are converted into universal angle observations. An observation model for points based on angle observations is proposed, and the relation between angle observations and global coordinates is established. Then, a spatial straight line of a four-parameter expression method is proposed, and an offset observation model for the line is established. Finally, based on the principle of indirect adjustment, error equations are established, and an overall adjustment solution is achieved for point targets and line targets. Experimental results show that the coordinate component differences are within 25 μm for point targets when comparing the coordinates measured by this system with those measured by a three-coordinate machine. The differences for line targets are within 10 μm in the transverse direction but large in vertical, possibly due to the influence of the illumination. The universal adjustment method for three-dimensional visual measurement proposed in this paper extends the measurement capability from point targets to line targets, providing a comprehensive solution for both types of targets. This method can also be applied for the data processing of multi-system combination measurements of visual photogrammetry systems and laser trackers, leveraging the strengths of different measurement systems and having broad application prospects.