Sami Daniel Harni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Sami Daniel Harni has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
- Hilkka Timonen
Atmospheric Composition Research, Finnish Meteorological Institute, Helsinki, Finland
26 shared publications - Tuukka Petäjä
Institute for Atmospheric and Earth System Research / Physics, University of Helsinki, Helsinki, Finland
19 shared publications - Topi Rönkkö
Aerosol Physics Laboratory, Physics Unit, Faculty of Engineering and Natural Sciences, Tampere University, 33014 Tampere, Finland
16 shared publications - Minna Aurela
Atmospheric Composition Research, Finnish Meteorological Institute, 00101 Helsinki, Finland
15 shared publications Sanna Saarikoski
Atmospheric Composition Research, Finnish Meteorological Institute, PL 503, 00101 Helsinki, Finland
14 shared publicationsHanna Manninen
Helsinki Region Environmental Services Authority HSY, Helsinki, Finland
11 shared publications
Latest Publications
- Open Access
- 22 September 2026
- Published by Copernicus GmbH in EGUsphere
- Vol. 2026, 1-23
Chemical composition of indoor and outdoor particles in a building near an international airport: Influence of local and long-range transported air pollution
Atmospheric pollution poses a significant threat to human health. These effects on human health are well documented in outdoor environments. However, in the Western world, people currently spend most of their time indoors. Therefore, studying the relationship between outdoor and indoor pollutant concentrations is essential. In this study, outdoor and indoor concentrations were measured in an unoccupied, mechanically ventilated building in Finland equipped with air-filtration and heat-recovery systems. Sampling was performed using a switching valve system that alternated sampling location between the building's air intake before filtration and the exhaust air vent, enabling near-simultaneous measurement of indoor and outdoor pollutant concentrations. The measurement campaign was conducted between 13th and 27th of February 2025. During the measurement period, a strong long-range transport (LRT) episode was observed, providing a good opportunity to study the effects of LRT on indoor pollutant concentrations. The measured variables included the chemical composition of aerosol particles, black carbon concentration, particle mass and number concentrations, and particle size distributions. Also, the effect of the nearby airport on the pollutant concentrations was discussed. The airport was found to have a large effect on particle number concentrations but almost no effect on particle mass or black carbon concentrations. The most abundant chemical component of aerosol particles both indoors and outdoors was organic matter. However, outside, the second most abundant component was nitrate, while indoors, more sulfate was measured. For the measured variables, the indoor-outdoor (I/O) ratios were calculated under normal and LRT conditions. Most of the I/O ratios remained stable between normal and LRT conditions. Exceptions to this were particulate matter and black carbon concentrations, which had higher I/O ratios during normal conditions, while particle number concentration had notably higher I/O ratios during LRT. The notably higher IO ratio of particle number concentrations was most likely due to the increase in the geometric mean diameter of particles. Notably, the ratios varied between the different measured components. The lowest I/O ratio of 0.20 ± 0.08 was observed for nitrate during the LRT. The low I/O ratio of nitrate might be related to the increasing temperature of aerosol particles while being transported indoors and therefore to increased evaporation. Under LRT conditions, the indoor black carbon concentrations increased to levels similar to those at street canyon measurement sites in Finland. The nearby airport was found to have a notable effect on the particle number but not particle mass concentrations or BC concentrations.
- 22 September 2026
- Published by Copernicus GmbH in EGUsphere
- Vol. 2026, 1-23
Open AccessChemical composition of indoor and outdoor particles in a building near an international airport: Influence of local and long-range transported air pollution
Atmospheric pollution poses a significant threat to human health. These effects on human health are well documented in outdoor environments. However, in the Western world, people currently spend most of their time indoors. Therefore, studying the relationship between outdoor and indoor pollutant concentrations is essential. In this study, outdoor and indoor concentrations were measured in an unoccupied, mechanically ventilated building in Finland equipped with air-filtration and heat-recovery systems. Sampling was performed using a switching valve system that alternated sampling location between the building's air intake before filtration and the exhaust air vent, enabling near-simultaneous measurement of indoor and outdoor pollutant concentrations. The measurement campaign was conducted between 13th and 27th of February 2025. During the measurement period, a strong long-range transport (LRT) episode was observed, providing a good opportunity to study the effects of LRT on indoor pollutant concentrations. The measured variables included the chemical composition of aerosol particles, black carbon concentration, particle mass and number concentrations, and particle size distributions. Also, the effect of the nearby airport on the pollutant concentrations was discussed. The airport was found to have a large effect on particle number concentrations but almost no effect on particle mass or black carbon concentrations. The most abundant chemical component of aerosol particles both indoors and outdoors was organic matter. However, outside, the second most abundant component was nitrate, while indoors, more sulfate was measured. For the measured variables, the indoor-outdoor (I/O) ratios were calculated under normal and LRT conditions. Most of the I/O ratios remained stable between normal and LRT conditions. Exceptions to this were particulate matter and black carbon concentrations, which had higher I/O ratios during normal conditions, while particle number concentration had notably higher I/O ratios during LRT. The notably higher IO ratio of particle number concentrations was most likely due to the increase in the geometric mean diameter of particles. Notably, the ratios varied between the different measured components. The lowest I/O ratio of 0.20 ± 0.08 was observed for nitrate during the LRT. The low I/O ratio of nitrate might be related to the increasing temperature of aerosol particles while being transported indoors and therefore to increased evaporation. Under LRT conditions, the indoor black carbon concentrations increased to levels similar to those at street canyon measurement sites in Finland. The nearby airport was found to have a notable effect on the particle number but not particle mass concentrations or BC concentrations.
- Open Access
- 14 March 2026
- Published by Copernicus GmbH
Outdoor–Indoor VOC Dynamics: Insights from multi-site measurements and impacts of long-range transport on indoor air quality
Indoor concentrations are consistently higher than outdoors for most VOCs due to indoor sources and limited ventilation. In Finland, outdoor VOC concentrations are low even in urban areas. However, sometimes outdoor air can be impacted by long-range transported (LRT) pollution and concentration levels of VOCs increase. Some of these VOCs also impact the indoor air. In this study we compared indoor-outdoor ratios of VOCs in different kind of environments in Finland (Vantaa and Tampere) Czech Republic (Prague) and Germany (Düsseldorf).Carbopack B tubes were collected at five different locations, both indoors and outdoors; two daycare centers in Tampere, office in Vantaa, office in Düsseldorf and a high school in Prague. In Vantaa, an online thermal desorption–gas chromatography–mass spectrometry (TD-GC-MS) system was additionally employed to measure indoor and outdoor air with a time resolution of 2 hours over the two-week period.During the Vantaa campaign with more intensive online VOC measurements a LRT event occurred providing an opportunity to investigate its impact on indoor air quality. For certain compounds, such as benzene, which is not effectively removed by building ventilation, a clear correlation was observed: as outdoor concentrations increased, indoor concentrations rose accordingly, closely matching the outdoor levels. Up to four times higher concentrations were measured both indoors and outdoors during the event. Benzene is a known carcinogenic and regulated by the EU. Similar levels in indoor and outdoor air were also observed in passive samples in all locations for benzene and tetrachloromethane indicating that the main source is in outdoor air. For most other compounds higher indoor air levels were detected. Especially for monoterpenes (α-pinene, 3Δ-carene and limonene) and octane clearly higher concentrations were measured in indoor air indicating strong indoor sources.
- 14 March 2026
- Published by Copernicus GmbH
Open AccessOutdoor–Indoor VOC Dynamics: Insights from multi-site measurements and impacts of long-range transport on indoor air quality
Indoor concentrations are consistently higher than outdoors for most VOCs due to indoor sources and limited ventilation. In Finland, outdoor VOC concentrations are low even in urban areas. However, sometimes outdoor air can be impacted by long-range transported (LRT) pollution and concentration levels of VOCs increase. Some of these VOCs also impact the indoor air. In this study we compared indoor-outdoor ratios of VOCs in different kind of environments in Finland (Vantaa and Tampere) Czech Republic (Prague) and Germany (Düsseldorf).Carbopack B tubes were collected at five different locations, both indoors and outdoors; two daycare centers in Tampere, office in Vantaa, office in Düsseldorf and a high school in Prague. In Vantaa, an online thermal desorption–gas chromatography–mass spectrometry (TD-GC-MS) system was additionally employed to measure indoor and outdoor air with a time resolution of 2 hours over the two-week period.During the Vantaa campaign with more intensive online VOC measurements a LRT event occurred providing an opportunity to investigate its impact on indoor air quality. For certain compounds, such as benzene, which is not effectively removed by building ventilation, a clear correlation was observed: as outdoor concentrations increased, indoor concentrations rose accordingly, closely matching the outdoor levels. Up to four times higher concentrations were measured both indoors and outdoors during the event. Benzene is a known carcinogenic and regulated by the EU. Similar levels in indoor and outdoor air were also observed in passive samples in all locations for benzene and tetrachloromethane indicating that the main source is in outdoor air. For most other compounds higher indoor air levels were detected. Especially for monoterpenes (α-pinene, 3Δ-carene and limonene) and octane clearly higher concentrations were measured in indoor air indicating strong indoor sources.
- Open Access
- 2 February 2026
- Published by Copernicus GmbH in Aerosol Research
- Vol. 4 (1) , 23-35
Primary particle emissions and atmospheric secondary aerosol formation potential from a large-scale wood-pellet-fired heating plant
Solid biofuels are one option to reduce fossil fuel combustion and mitigate climate change. However, large-scale combustion of solid biofuels can have significant impacts on air quality and the emissions of short-lived climate forcers. Due to the lack of detailed scientific experimental data on aerosol emissions, these atmospheric emissions and their aerosol impacts are largely unknown. In this study, we characterized primary particle emissions before and after the flue gas cleaning, as well as the potential of emissions to form secondary particulate mass in the atmosphere from the compounds emitted from a large-scale, biomass-fired modern heating plant. Experiments were conducted at three power plant loads, i.e., 30, 60, and 100 MW (full load), and, at each of these loads, flue gas particles were characterized for their physical and chemical characteristics. The study highlights the importance of efficient flue gas cleaning in biofuel applications; the bag-house filters (BHFs) utilized to clean the flue gas from the combustion boiler reduced the particle number emissions by 3 orders of magnitude, and the black carbon (BC) emissions were close to zero. After the filtration, at 30, 60, and 100 MW, the measured primary particle number emissions were 1.7 × 103, 5.2 × 103, and 7.2 × 103 MJ−1, respectively. By number, emitted particles existed mostly in the sub-200 nm mobility particle size range. When measuring the potential of flue gas to form secondary aerosol in the atmosphere, for the first time, according to the authors' knowledge, we observed that the secondary aerosol formation potential of flue gas is high; the total impact of flue gases on atmospheric particulate matter concentrations can even be 100 to 1000 times higher than the impact of primary particle emissions. In general, the results of the study enable emission inventory updates, improved air quality assessments, and climate modeling to support the transition toward climate-neutral societies.
- 2 February 2026
- Published by Copernicus GmbH in Aerosol Research
- Vol. 4 (1) , 23-35
Open AccessPrimary particle emissions and atmospheric secondary aerosol formation potential from a large-scale wood-pellet-fired heating plant
Solid biofuels are one option to reduce fossil fuel combustion and mitigate climate change. However, large-scale combustion of solid biofuels can have significant impacts on air quality and the emissions of short-lived climate forcers. Due to the lack of detailed scientific experimental data on aerosol emissions, these atmospheric emissions and their aerosol impacts are largely unknown. In this study, we characterized primary particle emissions before and after the flue gas cleaning, as well as the potential of emissions to form secondary particulate mass in the atmosphere from the compounds emitted from a large-scale, biomass-fired modern heating plant. Experiments were conducted at three power plant loads, i.e., 30, 60, and 100 MW (full load), and, at each of these loads, flue gas particles were characterized for their physical and chemical characteristics. The study highlights the importance of efficient flue gas cleaning in biofuel applications; the bag-house filters (BHFs) utilized to clean the flue gas from the combustion boiler reduced the particle number emissions by 3 orders of magnitude, and the black carbon (BC) emissions were close to zero. After the filtration, at 30, 60, and 100 MW, the measured primary particle number emissions were 1.7 × 103, 5.2 × 103, and 7.2 × 103 MJ−1, respectively. By number, emitted particles existed mostly in the sub-200 nm mobility particle size range. When measuring the potential of flue gas to form secondary aerosol in the atmosphere, for the first time, according to the authors' knowledge, we observed that the secondary aerosol formation potential of flue gas is high; the total impact of flue gases on atmospheric particulate matter concentrations can even be 100 to 1000 times higher than the impact of primary particle emissions. In general, the results of the study enable emission inventory updates, improved air quality assessments, and climate modeling to support the transition toward climate-neutral societies.
- Open Access
- 23 December 2025
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 25 (24) , 18719-18738
Measured and modelled air quality related effects of a noise barrier near a busy highway
A three-month air quality measurement campaign was conducted in spring 2023 near a busy highway in Espoo, Finland. The measurement site featured a high (6.5 m) noise barrier built adjacent to the highway. Additionally, there was a gap in the noise barrier at the selected measurement site, providing an opportunity to study the air quality impacts of the noise barrier. Several air quality measurement devices were installed behind the noise barrier and in the gap at distances of 10, 20 and 40 m from the side of the highway. Additionally, 15 passive samplers were deployed to monitor NO2 concentrations across the study area, mobile measurements were conducted using the ATMo-Lab mobile laboratory on the highway, and concurrent flights with drones equipped with AQ monitors were performed along the highway. The effects of the noise barrier on PM10, PM2.5, lung deposited surface area (LDSA), particle number concentration (PNC), NO2, and black carbon (BC) were quantified based on the analysed measurement data. Furthermore, the measurements were compared with simulated pollutant concentrations from a local-scale Gaussian air quality model (Enfuser) with a nearby obstacle detection and concentration reduction method incorporated in the model to address the effects of the noise barrier in the study. The noise barrier was found to effectively reduce pollutant concentrations behind the barrier. The most notable reductions were observed closest to the highway. The greatest reductions were observed for PM10 (mostly road dust) while gaseous concentrations, such as NO2, exhibited less pronounced decreases.
- 23 December 2025
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 25 (24) , 18719-18738
Open AccessMeasured and modelled air quality related effects of a noise barrier near a busy highway
A three-month air quality measurement campaign was conducted in spring 2023 near a busy highway in Espoo, Finland. The measurement site featured a high (6.5 m) noise barrier built adjacent to the highway. Additionally, there was a gap in the noise barrier at the selected measurement site, providing an opportunity to study the air quality impacts of the noise barrier. Several air quality measurement devices were installed behind the noise barrier and in the gap at distances of 10, 20 and 40 m from the side of the highway. Additionally, 15 passive samplers were deployed to monitor NO2 concentrations across the study area, mobile measurements were conducted using the ATMo-Lab mobile laboratory on the highway, and concurrent flights with drones equipped with AQ monitors were performed along the highway. The effects of the noise barrier on PM10, PM2.5, lung deposited surface area (LDSA), particle number concentration (PNC), NO2, and black carbon (BC) were quantified based on the analysed measurement data. Furthermore, the measurements were compared with simulated pollutant concentrations from a local-scale Gaussian air quality model (Enfuser) with a nearby obstacle detection and concentration reduction method incorporated in the model to address the effects of the noise barrier in the study. The noise barrier was found to effectively reduce pollutant concentrations behind the barrier. The most notable reductions were observed closest to the highway. The greatest reductions were observed for PM10 (mostly road dust) while gaseous concentrations, such as NO2, exhibited less pronounced decreases.
- Open Access
- 3 September 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-34
Comment on egusphere-2025-1423
A three-month air quality measurement campaign was conducted in spring 2023 near a busy highway in Espoo, Finland. The measurement site featured a high (6.5 m) noise barrier built adjacent to the highway. Additionally, there was a gap in the noise barrier at the selected measurement site, providing an opportunity to study the air quality impacts of the noise barrier. Several air quality measurement devices were installed behind the noise barrier and in the gap at distances of 10, 20 and 40 m from the side of the highway. Additionally, 15 passive samplers were deployed to monitor NO2 concentrations across the study area, mobile measurements were conducted using the ATMo-Lab mobile laboratory on the highway and concurrent flights with drones equipped with AQ monitors were performed along the highway. The effects of the noise barrier on PM10, PM2.5, lung deposited surface area (LDSA), particle number concentration (PNC), NO2, and black carbon (BC) were quantified based on analysed measurement data. Furthermore, the measurements were compared with simulated pollutant concentrations from a local scale Gaussian air quality model (Enfuser) with a nearby obstacle detection and concentration reduction method incorporated in the model to address the effects of the noise barrier in the study. The noise barrier was found to effectively reduce pollutant concentrations behind the barrier. The most significant reductions were observed closest to the highway. The greatest reductions were observed for PM10 (mostly road dust) while gaseous concentrations, such as NO2, exhibited less pronounced decreases.
- 3 September 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-34
Open AccessComment on egusphere-2025-1423
A three-month air quality measurement campaign was conducted in spring 2023 near a busy highway in Espoo, Finland. The measurement site featured a high (6.5 m) noise barrier built adjacent to the highway. Additionally, there was a gap in the noise barrier at the selected measurement site, providing an opportunity to study the air quality impacts of the noise barrier. Several air quality measurement devices were installed behind the noise barrier and in the gap at distances of 10, 20 and 40 m from the side of the highway. Additionally, 15 passive samplers were deployed to monitor NO2 concentrations across the study area, mobile measurements were conducted using the ATMo-Lab mobile laboratory on the highway and concurrent flights with drones equipped with AQ monitors were performed along the highway. The effects of the noise barrier on PM10, PM2.5, lung deposited surface area (LDSA), particle number concentration (PNC), NO2, and black carbon (BC) were quantified based on analysed measurement data. Furthermore, the measurements were compared with simulated pollutant concentrations from a local scale Gaussian air quality model (Enfuser) with a nearby obstacle detection and concentration reduction method incorporated in the model to address the effects of the noise barrier in the study. The noise barrier was found to effectively reduce pollutant concentrations behind the barrier. The most significant reductions were observed closest to the highway. The greatest reductions were observed for PM10 (mostly road dust) while gaseous concentrations, such as NO2, exhibited less pronounced decreases.
- Open Access
- 4 August 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-34
Comment on egusphere-2025-1423
A three-month air quality measurement campaign was conducted in spring 2023 near a busy highway in Espoo, Finland. The measurement site featured a high (6.5 m) noise barrier built adjacent to the highway. Additionally, there was a gap in the noise barrier at the selected measurement site, providing an opportunity to study the air quality impacts of the noise barrier. Several air quality measurement devices were installed behind the noise barrier and in the gap at distances of 10, 20 and 40 m from the side of the highway. Additionally, 15 passive samplers were deployed to monitor NO2 concentrations across the study area, mobile measurements were conducted using the ATMo-Lab mobile laboratory on the highway and concurrent flights with drones equipped with AQ monitors were performed along the highway. The effects of the noise barrier on PM10, PM2.5, lung deposited surface area (LDSA), particle number concentration (PNC), NO2, and black carbon (BC) were quantified based on analysed measurement data. Furthermore, the measurements were compared with simulated pollutant concentrations from a local scale Gaussian air quality model (Enfuser) with a nearby obstacle detection and concentration reduction method incorporated in the model to address the effects of the noise barrier in the study. The noise barrier was found to effectively reduce pollutant concentrations behind the barrier. The most significant reductions were observed closest to the highway. The greatest reductions were observed for PM10 (mostly road dust) while gaseous concentrations, such as NO2, exhibited less pronounced decreases.
- 4 August 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-34
Open AccessComment on egusphere-2025-1423
A three-month air quality measurement campaign was conducted in spring 2023 near a busy highway in Espoo, Finland. The measurement site featured a high (6.5 m) noise barrier built adjacent to the highway. Additionally, there was a gap in the noise barrier at the selected measurement site, providing an opportunity to study the air quality impacts of the noise barrier. Several air quality measurement devices were installed behind the noise barrier and in the gap at distances of 10, 20 and 40 m from the side of the highway. Additionally, 15 passive samplers were deployed to monitor NO2 concentrations across the study area, mobile measurements were conducted using the ATMo-Lab mobile laboratory on the highway and concurrent flights with drones equipped with AQ monitors were performed along the highway. The effects of the noise barrier on PM10, PM2.5, lung deposited surface area (LDSA), particle number concentration (PNC), NO2, and black carbon (BC) were quantified based on analysed measurement data. Furthermore, the measurements were compared with simulated pollutant concentrations from a local scale Gaussian air quality model (Enfuser) with a nearby obstacle detection and concentration reduction method incorporated in the model to address the effects of the noise barrier in the study. The noise barrier was found to effectively reduce pollutant concentrations behind the barrier. The most significant reductions were observed closest to the highway. The greatest reductions were observed for PM10 (mostly road dust) while gaseous concentrations, such as NO2, exhibited less pronounced decreases.
- Open Access
- 9 July 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-34
Comment on egusphere-2025-1423
A three-month air quality measurement campaign was conducted in spring 2023 near a busy highway in Espoo, Finland. The measurement site featured a high (6.5 m) noise barrier built adjacent to the highway. Additionally, there was a gap in the noise barrier at the selected measurement site, providing an opportunity to study the air quality impacts of the noise barrier. Several air quality measurement devices were installed behind the noise barrier and in the gap at distances of 10, 20 and 40 m from the side of the highway. Additionally, 15 passive samplers were deployed to monitor NO2 concentrations across the study area, mobile measurements were conducted using the ATMo-Lab mobile laboratory on the highway and concurrent flights with drones equipped with AQ monitors were performed along the highway. The effects of the noise barrier on PM10, PM2.5, lung deposited surface area (LDSA), particle number concentration (PNC), NO2, and black carbon (BC) were quantified based on analysed measurement data. Furthermore, the measurements were compared with simulated pollutant concentrations from a local scale Gaussian air quality model (Enfuser) with a nearby obstacle detection and concentration reduction method incorporated in the model to address the effects of the noise barrier in the study. The noise barrier was found to effectively reduce pollutant concentrations behind the barrier. The most significant reductions were observed closest to the highway. The greatest reductions were observed for PM10 (mostly road dust) while gaseous concentrations, such as NO2, exhibited less pronounced decreases.
- 9 July 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-34
Open AccessComment on egusphere-2025-1423
A three-month air quality measurement campaign was conducted in spring 2023 near a busy highway in Espoo, Finland. The measurement site featured a high (6.5 m) noise barrier built adjacent to the highway. Additionally, there was a gap in the noise barrier at the selected measurement site, providing an opportunity to study the air quality impacts of the noise barrier. Several air quality measurement devices were installed behind the noise barrier and in the gap at distances of 10, 20 and 40 m from the side of the highway. Additionally, 15 passive samplers were deployed to monitor NO2 concentrations across the study area, mobile measurements were conducted using the ATMo-Lab mobile laboratory on the highway and concurrent flights with drones equipped with AQ monitors were performed along the highway. The effects of the noise barrier on PM10, PM2.5, lung deposited surface area (LDSA), particle number concentration (PNC), NO2, and black carbon (BC) were quantified based on analysed measurement data. Furthermore, the measurements were compared with simulated pollutant concentrations from a local scale Gaussian air quality model (Enfuser) with a nearby obstacle detection and concentration reduction method incorporated in the model to address the effects of the noise barrier in the study. The noise barrier was found to effectively reduce pollutant concentrations behind the barrier. The most significant reductions were observed closest to the highway. The greatest reductions were observed for PM10 (mostly road dust) while gaseous concentrations, such as NO2, exhibited less pronounced decreases.
- Open Access
- 19 June 2025
- Published by Copernicus GmbH in EGUsphere
- Vol. 2025, 1-34
Measured and modelled air quality related effects of a noise barrier near a busy highway
A three-month air quality measurement campaign was conducted in spring 2023 near a busy highway in Espoo, Finland. The measurement site featured a high (6.5 m) noise barrier built adjacent to the highway. Additionally, there was a gap in the noise barrier at the selected measurement site, providing an opportunity to study the air quality impacts of the noise barrier. Several air quality measurement devices were installed behind the noise barrier and in the gap at distances of 10, 20 and 40 m from the side of the highway. Additionally, 15 passive samplers were deployed to monitor NO2 concentrations across the study area, mobile measurements were conducted using the ATMo-Lab mobile laboratory on the highway and concurrent flights with drones equipped with AQ monitors were performed along the highway. The effects of the noise barrier on PM10, PM2.5, lung deposited surface area (LDSA), particle number concentration (PNC), NO2, and black carbon (BC) were quantified based on analysed measurement data. Furthermore, the measurements were compared with simulated pollutant concentrations from a local scale Gaussian air quality model (Enfuser) with a nearby obstacle detection and concentration reduction method incorporated in the model to address the effects of the noise barrier in the study. The noise barrier was found to effectively reduce pollutant concentrations behind the barrier. The most significant reductions were observed closest to the highway. The greatest reductions were observed for PM10 (mostly road dust) while gaseous concentrations, such as NO2, exhibited less pronounced decreases.
- 19 June 2025
- Published by Copernicus GmbH in EGUsphere
- Vol. 2025, 1-34
Open AccessMeasured and modelled air quality related effects of a noise barrier near a busy highway
A three-month air quality measurement campaign was conducted in spring 2023 near a busy highway in Espoo, Finland. The measurement site featured a high (6.5 m) noise barrier built adjacent to the highway. Additionally, there was a gap in the noise barrier at the selected measurement site, providing an opportunity to study the air quality impacts of the noise barrier. Several air quality measurement devices were installed behind the noise barrier and in the gap at distances of 10, 20 and 40 m from the side of the highway. Additionally, 15 passive samplers were deployed to monitor NO2 concentrations across the study area, mobile measurements were conducted using the ATMo-Lab mobile laboratory on the highway and concurrent flights with drones equipped with AQ monitors were performed along the highway. The effects of the noise barrier on PM10, PM2.5, lung deposited surface area (LDSA), particle number concentration (PNC), NO2, and black carbon (BC) were quantified based on analysed measurement data. Furthermore, the measurements were compared with simulated pollutant concentrations from a local scale Gaussian air quality model (Enfuser) with a nearby obstacle detection and concentration reduction method incorporated in the model to address the effects of the noise barrier in the study. The noise barrier was found to effectively reduce pollutant concentrations behind the barrier. The most significant reductions were observed closest to the highway. The greatest reductions were observed for PM10 (mostly road dust) while gaseous concentrations, such as NO2, exhibited less pronounced decreases.
- Open Access
- 19 June 2025
- Published by Copernicus GmbH
Supplementary material to "Measured and modelled air quality related effects of a noise barrier near a busy highway"
- 19 June 2025
- Published by Copernicus GmbH
Open AccessSupplementary material to "Measured and modelled air quality related effects of a noise barrier near a busy highway"