Matan Kraus
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Matan Kraus has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Avinoah Ironi
Sackler School of Medicine, Tel Aviv University, Tel Aviv 69978, Israel
1 shared publication Eli Konen
Department of Diagnostic Imaging, Sheba Medical Center, Ramat Gan, Israel
1 shared publication- Eli Konen
Department of Diagnostic Imaging, Sheba Medical Center, Ramat Gan, Israel
1 shared publication Eyal Klang
Department of Diagnostic Imaging, Sheba Medical Center, Ramat Gan, Israel
1 shared publication- Eyal Klang
BRIDGE GenAI Lab, Beth Israel Deaconess Medical Center, Boston, MA, USA
1 shared publication Iris Eshed
Department of Diagnostic Imaging, Sheba Medical Center, Ramat Gan, Israel
1 shared publication
Latest Publications
- Open Access
- 12 March 2025
- Published by SAGE Publications in Journal of Children's Orthopaedics
- Vol. 19 (2) , 109-118
What’s new in pediatric musculoskeletal imaging
The field of pediatric musculoskeletal imaging is undergoing significant advancements due to technological innovations and a growing emphasis on safety and patient-centered care. This review explores recent developments in imaging modalities such as advanced magnetic resonance imaging, ultrasound innovations, and artificial intelligence applications. Highlights include radiation dose-reduction techniques in radiography and computed tomography, enhanced diagnostic tools like contrast-enhanced ultrasound and ultra-high-frequency imaging, and the integration of artificial intelligence for pathology detection and workflow optimization. The adoption of advanced methods like whole-body magnetic resonance imaging and computed tomography-like magnetic resonance imaging sequences has improved diagnostic accuracy, minimized radiation exposure, and expanded the capabilities of noninvasive imaging. Emerging technologies, including photon-counting detector computed tomography and deep learning-based reconstructions, are transforming clinical practices by balancing precision and safety. Artificial intelligence applications are reshaping diagnostic approaches, automating complex assessments, and improving efficiency, although challenges such as external validation and limited scope persist. Functional imaging advancements, such as diffusion-weighted imaging and positron emission tomography-magnetic resonance imaging integration, are enhancing disease characterization and treatment planning. This review underscores the clinical impact of these innovations, emphasizing the need for standardized protocols, interdisciplinary collaboration, and continued research to address unmet needs in radiation safety and artificial intelligence integration. It aims to equip healthcare professionals with the knowledge to leverage these advancements for improved outcomes in pediatric musculoskeletal care.
- 12 March 2025
- Published by SAGE Publications in Journal of Children's Orthopaedics
- Vol. 19 (2) , 109-118
Open AccessWhat’s new in pediatric musculoskeletal imaging
The field of pediatric musculoskeletal imaging is undergoing significant advancements due to technological innovations and a growing emphasis on safety and patient-centered care. This review explores recent developments in imaging modalities such as advanced magnetic resonance imaging, ultrasound innovations, and artificial intelligence applications. Highlights include radiation dose-reduction techniques in radiography and computed tomography, enhanced diagnostic tools like contrast-enhanced ultrasound and ultra-high-frequency imaging, and the integration of artificial intelligence for pathology detection and workflow optimization. The adoption of advanced methods like whole-body magnetic resonance imaging and computed tomography-like magnetic resonance imaging sequences has improved diagnostic accuracy, minimized radiation exposure, and expanded the capabilities of noninvasive imaging. Emerging technologies, including photon-counting detector computed tomography and deep learning-based reconstructions, are transforming clinical practices by balancing precision and safety. Artificial intelligence applications are reshaping diagnostic approaches, automating complex assessments, and improving efficiency, although challenges such as external validation and limited scope persist. Functional imaging advancements, such as diffusion-weighted imaging and positron emission tomography-magnetic resonance imaging integration, are enhancing disease characterization and treatment planning. This review underscores the clinical impact of these innovations, emphasizing the need for standardized protocols, interdisciplinary collaboration, and continued research to address unmet needs in radiation safety and artificial intelligence integration. It aims to equip healthcare professionals with the knowledge to leverage these advancements for improved outcomes in pediatric musculoskeletal care.
- Open Access
- 15 December 2023
- Published by Springer Nature in European Radiology
- Vol. 34 (7) , 4341-4351
Artificial intelligence for X-ray scaphoid fracture detection: a systematic review and diagnostic test accuracy meta-analysis
Objectives: Scaphoid fractures are usually diagnosed using X-rays, a low-sensitivity modality. Artificial intelligence (AI) using Convolutional Neural Networks (CNNs) has been explored for diagnosing scaphoid fractures in X-rays. The aim of this systematic review and meta-analysis is to evaluate the use of AI for detecting scaphoid fractures on X-rays and analyze its accuracy and usefulness. Materials and methods: This study followed the guidelines of Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) and PRISMA-Diagnostic Test Accuracy. A literature search was conducted in the PubMed database for original articles published until July 2023. The risk of bias and applicability were evaluated using the QUADAS-2 tool. A bivariate diagnostic random-effects meta-analysis was conducted, and the results were analyzed using the Summary Receiver Operating Characteristic (SROC) curve. Results: Ten studies met the inclusion criteria and were all retrospective. The AI’s diagnostic performance for detecting scaphoid fractures ranged from AUC 0.77 to 0.96. Seven studies were included in the meta-analysis, with a total of 3373 images. The meta-analysis pooled sensitivity and specificity were 0.80 and 0.89, respectively. The meta-analysis overall AUC was 0.88. The QUADAS-2 tool found high risk of bias and concerns about applicability in 9 out of 10 studies. Conclusions: The current results of AI’s diagnostic performance for detecting scaphoid fractures in X-rays show promise. The results show high overall sensitivity and specificity and a high SROC result. Further research is needed to compare AI’s diagnostic performance to human diagnostic performance in a clinical setting. Clinical relevance statement: Scaphoid fractures are prone to be missed secondary to assessment with a low sensitivity modality and a high occult fracture rate. AI systems can be beneficial for clinicians and radiologists to facilitate early diagnosis, and avoid missed injuries. Key Points: • Scaphoid fractures are common and some can be easily missed in X-rays. • Artificial intelligence (AI) systems demonstrate high diagnostic performance for the diagnosis of scaphoid fractures in X-rays. • AI systems can be beneficial in diagnosing both obvious and occult scaphoid fractures.
- 15 December 2023
- Published by Springer Nature in European Radiology
- Vol. 34 (7) , 4341-4351
Open AccessArtificial intelligence for X-ray scaphoid fracture detection: a systematic review and diagnostic test accuracy meta-analysis
Objectives: Scaphoid fractures are usually diagnosed using X-rays, a low-sensitivity modality. Artificial intelligence (AI) using Convolutional Neural Networks (CNNs) has been explored for diagnosing scaphoid fractures in X-rays. The aim of this systematic review and meta-analysis is to evaluate the use of AI for detecting scaphoid fractures on X-rays and analyze its accuracy and usefulness. Materials and methods: This study followed the guidelines of Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) and PRISMA-Diagnostic Test Accuracy. A literature search was conducted in the PubMed database for original articles published until July 2023. The risk of bias and applicability were evaluated using the QUADAS-2 tool. A bivariate diagnostic random-effects meta-analysis was conducted, and the results were analyzed using the Summary Receiver Operating Characteristic (SROC) curve. Results: Ten studies met the inclusion criteria and were all retrospective. The AI’s diagnostic performance for detecting scaphoid fractures ranged from AUC 0.77 to 0.96. Seven studies were included in the meta-analysis, with a total of 3373 images. The meta-analysis pooled sensitivity and specificity were 0.80 and 0.89, respectively. The meta-analysis overall AUC was 0.88. The QUADAS-2 tool found high risk of bias and concerns about applicability in 9 out of 10 studies. Conclusions: The current results of AI’s diagnostic performance for detecting scaphoid fractures in X-rays show promise. The results show high overall sensitivity and specificity and a high SROC result. Further research is needed to compare AI’s diagnostic performance to human diagnostic performance in a clinical setting. Clinical relevance statement: Scaphoid fractures are prone to be missed secondary to assessment with a low sensitivity modality and a high occult fracture rate. AI systems can be beneficial for clinicians and radiologists to facilitate early diagnosis, and avoid missed injuries. Key Points: • Scaphoid fractures are common and some can be easily missed in X-rays. • Artificial intelligence (AI) systems demonstrate high diagnostic performance for the diagnosis of scaphoid fractures in X-rays. • AI systems can be beneficial in diagnosing both obvious and occult scaphoid fractures.
- Open Access
- 12 August 2023
- Published by Elsevier in European Journal of Radiology Open
- Vol. 11, 100515
MRI features of intraductal papillary mucinous neoplasm of the bile ducts, “The myth about the cyst”: A systematic review
- 12 August 2023
- Published by Elsevier in European Journal of Radiology Open
- Vol. 11, 100515
Open AccessMRI features of intraductal papillary mucinous neoplasm of the bile ducts, “The myth about the cyst”: A systematic review
- Open Access
- 1 January 2023
- Published by Oxford University Press (OUP) in BJR|case reports
- Vol. 9 (1) , 20220100
Interrupted inferior vena cava with deep vein thrombosis
A 22-year-old healthy man presented to the emergency department with worsening left flank and testicular pain. Lower abdominal pain and lower urinary tract symptoms, were also noted.Contrast-enhanced CT demonstrated several vascular malformations: both common iliac veins converging to an infrarenal inferior vena cava (IVC) with an absent cephalad IVC. Multiple collateral veins were noted, and both the Azygos and Hemiazygos veins were seen dilated, serving as an alternative venous drainage path due to the interrupted IVC.The patient’s CT was also notable for several pathologies: bilateral iliac vein thrombosis and left-sided testicular vein thrombus with surrounding fat stranding, suggestive of testicular vein thrombophlebitis.The patient was admitted, and received antibiotic and anticoagulation treatment, with clinical improvement.Hypercoagulability work-up was obtained, and the patient was found to be heterozygous for Factor V Leiden.Interrupted IVC with azygos continuation is an uncommon, and mostly a benign vascular malformation, resulting from abnormal development of IVC-contributing segments during embryogenesis. It is associated with lower limb deep vein thombosis and hypercoagulable states. It is imperative for radiologists to be acquainted with this entity, in order to avoid misdiagnosis.Testicular vein thrombosis is uncommon, mostly associated with prothrombotic disorders, and it should be considered when coagulopathy is suspected.
- 1 January 2023
- Published by Oxford University Press (OUP) in BJR|case reports
- Vol. 9 (1) , 20220100
Open AccessInterrupted inferior vena cava with deep vein thrombosis
A 22-year-old healthy man presented to the emergency department with worsening left flank and testicular pain. Lower abdominal pain and lower urinary tract symptoms, were also noted.Contrast-enhanced CT demonstrated several vascular malformations: both common iliac veins converging to an infrarenal inferior vena cava (IVC) with an absent cephalad IVC. Multiple collateral veins were noted, and both the Azygos and Hemiazygos veins were seen dilated, serving as an alternative venous drainage path due to the interrupted IVC.The patient’s CT was also notable for several pathologies: bilateral iliac vein thrombosis and left-sided testicular vein thrombus with surrounding fat stranding, suggestive of testicular vein thrombophlebitis.The patient was admitted, and received antibiotic and anticoagulation treatment, with clinical improvement.Hypercoagulability work-up was obtained, and the patient was found to be heterozygous for Factor V Leiden.Interrupted IVC with azygos continuation is an uncommon, and mostly a benign vascular malformation, resulting from abnormal development of IVC-contributing segments during embryogenesis. It is associated with lower limb deep vein thombosis and hypercoagulable states. It is imperative for radiologists to be acquainted with this entity, in order to avoid misdiagnosis.Testicular vein thrombosis is uncommon, mostly associated with prothrombotic disorders, and it should be considered when coagulopathy is suspected.
- 12 October 2022
- Published by Springer Nature in Abdominal Radiology
- Vol. 48 (1) , 229-235
CT signs of hypovolemic shock complex in patients with non-traumatic shock
- 12 October 2022
- Published by Springer Nature in Abdominal Radiology
- Vol. 48 (1) , 229-235
CT signs of hypovolemic shock complex in patients with non-traumatic shock