Yonggang Lei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yonggang Lei has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Wuxuan Pan
School of Civil Engineering, Taiyuan University of Technology, Taiyuan 030024, China
4 shared publications - Chongfang Song
School of Civil Engineering, Taiyuan University of Technology, Taiyuan 030024, China
3 shared publications Baocun Du
Taiyuan University of Technology College of Civil Engineering 030024 Taiyuan China
2 shared publicationsChongfang Song
Taiyuan University of Technology College of Civil Engineering 030024 Taiyuan China
2 shared publications- Yonghui Wang
School of Civil Engineering, Taiyuan University of Technology, Taiyuan 030024, China
2 shared publications Angui Li
HVAC, Xi'an University of Architecture and Technology, China
1 shared publication
Latest Publications
- Open Access
Safety–Performance Trade-Offs of Phase-Change Materials in Battery Thermal Management: Materials, Systems, and Deployment
Lithium-ion batteries (LIBs) typically operate within a temperature range of 20–50 °C, depending on the chemical composition and application of the battery. Overheating may lead to degradation and thermal runaway, while overcooling may cause lithium plating and internal short circuits. Absorbing heat during the melting of phase-change materials (PCMs) has become an attractive passive thermal management strategy. However, organic PCMs such as paraffin are flammable, and most strategies for improving their inherently low thermal conductivity, such as adding carbon fillers and engineering porous scaffolds, sacrifice latent heat, electrical safety, or cost. Flame retardants achieve flame retardancy at the cost of 15–25% of latent heat, while inorganic PCMs eliminate flammability but introduce undercooling and corrosion. This study synthesizes the PCM–battery thermal management system (BTMS) literature with this safety–performance tension as its organizing principle, covering composite PCM strategies for thermal enhancement, flame-retardant approaches and thermal runaway mitigation, hybrid PCM–active cooling systems, and emerging directions that transcend rather than manage the trade-off. It also identifies the gaps between laboratory demonstration and commercial deployment: durability data measured in hundreds rather than thousands of cycles, absent standardized testing protocols, and manufacturing routes that have not left the university laboratory.
Open AccessSafety–Performance Trade-Offs of Phase-Change Materials in Battery Thermal Management: Materials, Systems, and Deployment
Lithium-ion batteries (LIBs) typically operate within a temperature range of 20–50 °C, depending on the chemical composition and application of the battery. Overheating may lead to degradation and thermal runaway, while overcooling may cause lithium plating and internal short circuits. Absorbing heat during the melting of phase-change materials (PCMs) has become an attractive passive thermal management strategy. However, organic PCMs such as paraffin are flammable, and most strategies for improving their inherently low thermal conductivity, such as adding carbon fillers and engineering porous scaffolds, sacrifice latent heat, electrical safety, or cost. Flame retardants achieve flame retardancy at the cost of 15–25% of latent heat, while inorganic PCMs eliminate flammability but introduce undercooling and corrosion. This study synthesizes the PCM–battery thermal management system (BTMS) literature with this safety–performance tension as its organizing principle, covering composite PCM strategies for thermal enhancement, flame-retardant approaches and thermal runaway mitigation, hybrid PCM–active cooling systems, and emerging directions that transcend rather than manage the trade-off. It also identifies the gaps between laboratory demonstration and commercial deployment: durability data measured in hundreds rather than thousands of cycles, absent standardized testing protocols, and manufacturing routes that have not left the university laboratory.
- Open Access
Analysis of Pollutant Dispersion in High-Rise Buildings Under Wind–Thermal Coupling
Controlling pollutant dispersion in high-rise buildings is crucial for public health. Vertical pollutant diffusion in stairwells occurs under thermal and wind effects. However, most existing studies rely on idealized boundary conditions. To address this, this study uses field-measured wall temperatures and a window wind velocity as boundary conditions for transient CFD simulations. We investigate the vertical diffusion characteristics of buoyant (CH4) and dense (CO2) pollutants under thermal pressure, window velocity, and wind–thermal coupling in a high-rise residential building in Taiyuan. Results show an asymmetric “fast-up, slow-down” diffusion under thermal pressure, a relatively symmetric profile under window velocity, and a hybrid pattern under coupling where the upper region is wind-dominated and the lower region resembles thermal-driven diffusion. Wind–thermal coupling most significantly enhances upward diffusion. Using the arrival time of CH4 at the 28th floor (about 15 m above the source floor) as the benchmark, the diffusion rate under coupling is about 200% faster than under thermal pressure alone, and about 50% faster than under the window-velocity condition alone. Differences in density lead to variations in dispersion, with CH4 exhibiting higher rates, concentrations (2–4 orders greater), and a broader influence range than CO2. This work interprets the synergistic regulatory mechanism between driving forces and pollutant density, providing a theoretical basis for ventilation optimization and pollution control in high-rise buildings.
Open AccessAnalysis of Pollutant Dispersion in High-Rise Buildings Under Wind–Thermal Coupling
Controlling pollutant dispersion in high-rise buildings is crucial for public health. Vertical pollutant diffusion in stairwells occurs under thermal and wind effects. However, most existing studies rely on idealized boundary conditions. To address this, this study uses field-measured wall temperatures and a window wind velocity as boundary conditions for transient CFD simulations. We investigate the vertical diffusion characteristics of buoyant (CH4) and dense (CO2) pollutants under thermal pressure, window velocity, and wind–thermal coupling in a high-rise residential building in Taiyuan. Results show an asymmetric “fast-up, slow-down” diffusion under thermal pressure, a relatively symmetric profile under window velocity, and a hybrid pattern under coupling where the upper region is wind-dominated and the lower region resembles thermal-driven diffusion. Wind–thermal coupling most significantly enhances upward diffusion. Using the arrival time of CH4 at the 28th floor (about 15 m above the source floor) as the benchmark, the diffusion rate under coupling is about 200% faster than under thermal pressure alone, and about 50% faster than under the window-velocity condition alone. Differences in density lead to variations in dispersion, with CH4 exhibiting higher rates, concentrations (2–4 orders greater), and a broader influence range than CO2. This work interprets the synergistic regulatory mechanism between driving forces and pollutant density, providing a theoretical basis for ventilation optimization and pollution control in high-rise buildings.
- Open Access
Calculation of Pollutant and Thermal Accumulation in Recirculating Ventilation Systems with Discrete High-Temperature Sources
The non-fixed location and intermittent emission of pollution sources are posing significant challenges for industrial ventilation and dust removal. Owing to its energy-saving and emission-reduction advantages, recirculating ventilation has emerged as a critical solution in industrial ventilation. However, the introduction of recirculated air leads to the accumulation of both pollutants and temperature in controlled environments. However, the accumulation situation and control methods within the recirculation air system are still not fully understood, especially for discrete pollution sources. Theoretical models were developed in this paper to quantitatively calculate these issues. Then, the spatiotemporal distributions of air temperature and pollutant concentrations were investigated within the controlled environment by numerical simulation. The result shows that upper limits exist for both pollutant and heat accumulation. Controlling the recirculation air ratio between 0% and 60% resulted in a corresponding increase in pollutant concentration ranging up to 28.58% and a temperature rise of up to 6.16%. At a 27.8% recirculation ratio, fresh air consumption decreased by 27.8%, mean pollutant concentration increased by 5.50%, and mean air temperature rose by 3.78%. In addition, the dynamic characteristics of pollutant concentration and temperature variation at different circulating air ratios were analyzed. The recirculating air system effectively conserves energy and reduces emissions. The quantitative calculation models can facilitate the adoption and promotion of such systems, thereby contributing to industrial green development.
Open AccessCalculation of Pollutant and Thermal Accumulation in Recirculating Ventilation Systems with Discrete High-Temperature Sources
The non-fixed location and intermittent emission of pollution sources are posing significant challenges for industrial ventilation and dust removal. Owing to its energy-saving and emission-reduction advantages, recirculating ventilation has emerged as a critical solution in industrial ventilation. However, the introduction of recirculated air leads to the accumulation of both pollutants and temperature in controlled environments. However, the accumulation situation and control methods within the recirculation air system are still not fully understood, especially for discrete pollution sources. Theoretical models were developed in this paper to quantitatively calculate these issues. Then, the spatiotemporal distributions of air temperature and pollutant concentrations were investigated within the controlled environment by numerical simulation. The result shows that upper limits exist for both pollutant and heat accumulation. Controlling the recirculation air ratio between 0% and 60% resulted in a corresponding increase in pollutant concentration ranging up to 28.58% and a temperature rise of up to 6.16%. At a 27.8% recirculation ratio, fresh air consumption decreased by 27.8%, mean pollutant concentration increased by 5.50%, and mean air temperature rose by 3.78%. In addition, the dynamic characteristics of pollutant concentration and temperature variation at different circulating air ratios were analyzed. The recirculating air system effectively conserves energy and reduces emissions. The quantitative calculation models can facilitate the adoption and promotion of such systems, thereby contributing to industrial green development.
- 9 November 2025
- Published by Springer Nature
- p. 361-370
Experimental Study on Melting and Solidification in a Trombe Wall Integrated with Multi-row Channel PCM Wallboard
- 9 November 2025
- Published by Springer Nature
- p. 361-370
Experimental Study on Melting and Solidification in a Trombe Wall Integrated with Multi-row Channel PCM Wallboard
- 9 November 2025
- Published by Springer Nature
- p. 266-274
Application of Nonlinear Topology Optimization Method in Staged Construction of District Heating Network Engineering
- 9 November 2025
- Published by Springer Nature
- p. 266-274
Application of Nonlinear Topology Optimization Method in Staged Construction of District Heating Network Engineering
- 26 January 2023
- Published by Wiley in Chemical Engineering & Technology
- Vol. 46 (4) , 794-802
Effect of Geometric Parameters on the Performance of a Membrane-Based Enthalpy Exchanger
- 26 January 2023
- Published by Wiley in Chemical Engineering & Technology
- Vol. 46 (4) , 794-802
Effect of Geometric Parameters on the Performance of a Membrane-Based Enthalpy Exchanger
- 1 November 2022
- Published by AIP Publishing in Physics of Fluids
- Vol. 34 (11)
Field synergy principle for compressible laminar flow and the application for drag reduction in microchannel
Considering the density variation of compressible fluid, the field synergy principle for compressible laminar flow is presented based on the incompressible flow field synergy principle. The flow resistance is related to the synergy of velocity field and density logarithmic gradient field. Based on the principle of minimum mechanical energy dissipation, the compressible laminar flow field synergy equation is derived. The field synergy principle is verified by an example of the microchannel with expansion cross section, and the structure is optimized. The results indicate that the viscous dissipation value in the entire flow domain of the optimized structure can be reduced by 13.5%, and the angle between the velocity vector and the gradient field of logarithm of density increases. In fluid flows, it will reduce the fluid flow drag to decrease the synergy angle between the velocity vector and the gradient field of logarithm of density.
- 1 November 2022
- Published by AIP Publishing in Physics of Fluids
- Vol. 34 (11)
Field synergy principle for compressible laminar flow and the application for drag reduction in microchannel
Considering the density variation of compressible fluid, the field synergy principle for compressible laminar flow is presented based on the incompressible flow field synergy principle. The flow resistance is related to the synergy of velocity field and density logarithmic gradient field. Based on the principle of minimum mechanical energy dissipation, the compressible laminar flow field synergy equation is derived. The field synergy principle is verified by an example of the microchannel with expansion cross section, and the structure is optimized. The results indicate that the viscous dissipation value in the entire flow domain of the optimized structure can be reduced by 13.5%, and the angle between the velocity vector and the gradient field of logarithm of density increases. In fluid flows, it will reduce the fluid flow drag to decrease the synergy angle between the velocity vector and the gradient field of logarithm of density.
- Open Access
Natural Ventilation Enhancement of a Roof Solar Chimney with Wind-Induced Channel
A novel roof solar chimney with wind-induced channel was designed herein to augment indoor natural ventilation under combined action of wind and solar energy. Compared with the traditional solar chimney, the new rooftop solar chimney improves the air flow due to the wind-induced channel. The effects of channel width ratio, chimney inclination at different outdoor wind speeds on the natural ventilation performance of the roof solar chimney were studied by numerical simulation. Finite-volume method was used for the numerical calculation. It was found that the trends of ventilation rate are different when the channel widths increase. The mass flow rate of the new structure increases with the increase in the inclination angle. When the inclination angles increase from 30° to 90°, the ventilation rate increases by 212% for U = 1.0 m·s−1, 166% for U = 2.0 m·s−1, and 127% for U = 3.0 m·s−1 under the condition of and the solar radiation I = 600 W·m−2.
Open AccessNatural Ventilation Enhancement of a Roof Solar Chimney with Wind-Induced Channel
A novel roof solar chimney with wind-induced channel was designed herein to augment indoor natural ventilation under combined action of wind and solar energy. Compared with the traditional solar chimney, the new rooftop solar chimney improves the air flow due to the wind-induced channel. The effects of channel width ratio, chimney inclination at different outdoor wind speeds on the natural ventilation performance of the roof solar chimney were studied by numerical simulation. Finite-volume method was used for the numerical calculation. It was found that the trends of ventilation rate are different when the channel widths increase. The mass flow rate of the new structure increases with the increase in the inclination angle. When the inclination angles increase from 30° to 90°, the ventilation rate increases by 212% for U = 1.0 m·s−1, 166% for U = 2.0 m·s−1, and 127% for U = 3.0 m·s−1 under the condition of and the solar radiation I = 600 W·m−2.
- Open Access
- 31 August 2022
- Published by EDP Sciences
- Vol. 356, 03057
Study on ventilation performance of inclined solar chimney coupled with indoor heat source
The study of ventilation air distribution of the building with built-in heat source and set inclined solar chimney is carried out through 3D numerical simulation. The synergistic effect of thermal plume formed by internal heat source and solar chimney effect is analyzed. The effects of different solar radiation intensity I, heat flow density W at the surface of the internal heat source and structural parameters (including the height of the internal heat source from the ground h and the mezzanine inlet spacing b) on the indoor natural ventilation performance of the building are investigated.
- 31 August 2022
- Published by EDP Sciences
- Vol. 356, 03057
Open AccessStudy on ventilation performance of inclined solar chimney coupled with indoor heat source
The study of ventilation air distribution of the building with built-in heat source and set inclined solar chimney is carried out through 3D numerical simulation. The synergistic effect of thermal plume formed by internal heat source and solar chimney effect is analyzed. The effects of different solar radiation intensity I, heat flow density W at the surface of the internal heat source and structural parameters (including the height of the internal heat source from the ground h and the mezzanine inlet spacing b) on the indoor natural ventilation performance of the building are investigated.
- 1 August 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Pipeline Systems Engineering and Practice
- Vol. 11 (3) , 04020028
Thermal Fatigue Analysis of the Secondary Network of District Heating Systems in China
Central heating is the main heating method in cities in northern China in winter, and it is also an important part of urban utilities. The safety of the heating pipe network operation is an important livelihood issue. Temperature fatigue damage of the central heating pipeline has a severe impact on the safe operation of the system, and reasonable estimation of the number of fatigue cycles during the service life of the pipeline is an essential link in the pipeline design of a district heating (DH) system. The temperature data of five typical secondary networks of heat exchanger stations in Jiancao District of Taiyuan City in four heating seasons were collected. The frequency of temperature change during operation was counted, and the maximum total temperature difference cycle number of pipelines was estimated. In this paper, the regression analysis method is adopted to fit the design equation of the number of temperature cycles of water supply and return pipelines in 30 years of service life, which provides a way of thinking for predicting the number of temperature difference fatigue cycles of pipelines in the design stage. In the calculation of the number of maximum total temperature difference cycles, the different values of temperature difference defining parameter and reference temperature difference are analyzed. The results show that the selection of temperature difference defining parameter can effectively distinguish the effect of large and small temperature difference on the number of fatigue cycles of pipelines; at the same time, the cyclic temperature difference is normalized within a specific range of design temperature difference, which overcomes the problem of simplifying the guidance of the operation parameters of the central heating system and makes the predicted maximum total temperature difference cycle have universal guiding significance in a specific heating area.- 1 August 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Pipeline Systems Engineering and Practice
- Vol. 11 (3) , 04020028
Thermal Fatigue Analysis of the Secondary Network of District Heating Systems in China
Central heating is the main heating method in cities in northern China in winter, and it is also an important part of urban utilities. The safety of the heating pipe network operation is an important livelihood issue. Temperature fatigue damage of the central heating pipeline has a severe impact on the safe operation of the system, and reasonable estimation of the number of fatigue cycles during the service life of the pipeline is an essential link in the pipeline design of a district heating (DH) system. The temperature data of five typical secondary networks of heat exchanger stations in Jiancao District of Taiyuan City in four heating seasons were collected. The frequency of temperature change during operation was counted, and the maximum total temperature difference cycle number of pipelines was estimated. In this paper, the regression analysis method is adopted to fit the design equation of the number of temperature cycles of water supply and return pipelines in 30 years of service life, which provides a way of thinking for predicting the number of temperature difference fatigue cycles of pipelines in the design stage. In the calculation of the number of maximum total temperature difference cycles, the different values of temperature difference defining parameter and reference temperature difference are analyzed. The results show that the selection of temperature difference defining parameter can effectively distinguish the effect of large and small temperature difference on the number of fatigue cycles of pipelines; at the same time, the cyclic temperature difference is normalized within a specific range of design temperature difference, which overcomes the problem of simplifying the guidance of the operation parameters of the central heating system and makes the predicted maximum total temperature difference cycle have universal guiding significance in a specific heating area.