Ping Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ping Xu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Bo Wang
Fudan Univ, Huashan Hosp, Dept Ultrasound, 12 Urumqi Rd, Shanghai 200040, Peoples R China
1 shared publication- Dandan Sheng
Sports Medicine Institute of Fudan University, Department of Sports Medicine, Huashan Hospital, Fudan University, Shanghai, 200040, China
1 shared publication Danru Liu
Fudan Univ, Huashan Hosp, Dept Ultrasound, 12 Urumqi Rd, Shanghai 200040, Peoples R China
1 shared publicationEdward G Grant
Department of Radiology, University of Southern California, Keck School of Medicine, USC University Hospital, Los Angeles, CA, USA
1 shared publication- Haojun Zhao
Department of Ultrasound, Huashan Hospital, Fudan University, Shanghai, China
1 shared publication Hong Ding
Fudan Univ, Huashan Hosp, Dept Ultrasound, 12 Urumqi Rd, Shanghai 200040, Peoples R China
1 shared publication
Latest Publications
- Open Access
- 13 October 2022
- Published by Wiley in Contrast Media & Molecular Imaging
- Vol. 2022 (1) , 6867743
Quantitative Analysis of Contrast‐Enhanced Ultrasound That Can Be Used to Evaluate Angiogenesis during Patellar Tendon Healing in Rats
Objective. To investigate the efficacy of contrast‐enhanced ultrasound (CEUS) in quantitatively evaluating angiogenesis during patellar tendon healing in rats. Methods. A total of 40 Sprague–Dawley rats were used in this study. The patellar tendons of 30 rats (60 limbs) that underwent incision and suture were treated as the operation group and monitored after 7, 14, and 28 days. The normal patellar tendons of 10 rats (20 limbs) were treated as the control group and monitored on day 0. The ultrasound examination was used to evaluate the structure and blood perfusion of the patellar tendon. Immunohistochemistry was used to assess angiogenesis, and the biomechanical test was used to verify functional recovery of the patellar tendon. Results. The tendons in the operation group were significantly thickened compared with those in the control group (p < 0.01). The peak intensity (PI) in CEUS of the tendons showed a clear difference at each time point after the surgery (p < 0.01). PI increased in the operation group with a maximum on day 7, and then gradually decreased until day 28 when PI was close to the basic intensity (BI) in the control group (p > 0.05). It was consistent with the change of the CD31‐positive staining areas representing angiogenesis of the injured patellar tendons. The PI was positively correlated with the CD31‐positive staining area fraction (R = 0.849, p < 0.001). The failure load and tensile strength of the repaired patellar tendons in the operation group increased over time. The PI showed negative correlations with the failure load (R = −0.787, p < 0.001) and tensile strength (R = −0.714, p < 0.001). Conclusion. The PI in CEUS could quantitatively reflect the time‐dependent change in the blood supply of the healing site, and the PI correlated with histologic and biomechanical properties of the healing tendon. Quantitative analysis of contrast‐enhanced ultrasound could be a useful method to evaluate angiogenesis in healing tendons.
- 13 October 2022
- Published by Wiley in Contrast Media & Molecular Imaging
- Vol. 2022 (1) , 6867743
Open AccessQuantitative Analysis of Contrast‐Enhanced Ultrasound That Can Be Used to Evaluate Angiogenesis during Patellar Tendon Healing in Rats
Objective. To investigate the efficacy of contrast‐enhanced ultrasound (CEUS) in quantitatively evaluating angiogenesis during patellar tendon healing in rats. Methods. A total of 40 Sprague–Dawley rats were used in this study. The patellar tendons of 30 rats (60 limbs) that underwent incision and suture were treated as the operation group and monitored after 7, 14, and 28 days. The normal patellar tendons of 10 rats (20 limbs) were treated as the control group and monitored on day 0. The ultrasound examination was used to evaluate the structure and blood perfusion of the patellar tendon. Immunohistochemistry was used to assess angiogenesis, and the biomechanical test was used to verify functional recovery of the patellar tendon. Results. The tendons in the operation group were significantly thickened compared with those in the control group (p < 0.01). The peak intensity (PI) in CEUS of the tendons showed a clear difference at each time point after the surgery (p < 0.01). PI increased in the operation group with a maximum on day 7, and then gradually decreased until day 28 when PI was close to the basic intensity (BI) in the control group (p > 0.05). It was consistent with the change of the CD31‐positive staining areas representing angiogenesis of the injured patellar tendons. The PI was positively correlated with the CD31‐positive staining area fraction (R = 0.849, p < 0.001). The failure load and tensile strength of the repaired patellar tendons in the operation group increased over time. The PI showed negative correlations with the failure load (R = −0.787, p < 0.001) and tensile strength (R = −0.714, p < 0.001). Conclusion. The PI in CEUS could quantitatively reflect the time‐dependent change in the blood supply of the healing site, and the PI correlated with histologic and biomechanical properties of the healing tendon. Quantitative analysis of contrast‐enhanced ultrasound could be a useful method to evaluate angiogenesis in healing tendons.
- 6 September 2022
- Published by SAGE Publications in Technology and Health Care
- Vol. 30 (5) , 1043-1054
Application value of gray-scale ultrasound and shear wave elastography in differential diagnosis of thyroid nodules
BACKGROUND: The global prevalence of thyroid cancer has increased significantly in recent years. Ultrasonography is the preferred method for differentiating benign and malignant thyroid nodules preoperatively and is recommended by guidelines. OBJECTIVE: To assess the application value of gray-scale ultrasound and shear wave elastography in distinguishing small thyroid nodules. METHODS: A retrospective analysis of 228 thyroid nodules, all of which were confirmed by pathology after surgery or FNA from January 2019 to January 2020, was carried out. All nodules were divided into a ⩽ 5 mm group and a > 5 mm group according to their maximum size. We compared the differences in the gray scale and elastography of the nodules between the two groups and the accuracy of different diagnostic methods. RESULTS: The accuracies of gray-scale ultrasound and shear wave elastography in the ⩽ 5 mm group were found to be lower than those in the > 5 mm group, and the gray-scale accuracy was slightly higher than that of shear wave elastography in both groups (p< 0.05). The largest AUC (area under the curve) of elastic parameters in the ⩽ 5 mm and > 5 mm groups was found for Emax and Esd, respectively. Based on a combination of these two parameters, the accuracies of the two groups were significantly higher than those of the parameters or gray scale alone (p< 0.05) and were 84.62% and 85.48%, respectively. CONCLUSION: Shear wave elastography is valuable in the diagnosis of benign and malignant thyroid nodules using ultrasonography. When combining gray-scale ultrasound and shear wave elastography, the diagnostic accuracy is obviously improved, especially for ⩽ 5 mm small thyroid nodules.
- 6 September 2022
- Published by SAGE Publications in Technology and Health Care
- Vol. 30 (5) , 1043-1054
Application value of gray-scale ultrasound and shear wave elastography in differential diagnosis of thyroid nodules
BACKGROUND: The global prevalence of thyroid cancer has increased significantly in recent years. Ultrasonography is the preferred method for differentiating benign and malignant thyroid nodules preoperatively and is recommended by guidelines. OBJECTIVE: To assess the application value of gray-scale ultrasound and shear wave elastography in distinguishing small thyroid nodules. METHODS: A retrospective analysis of 228 thyroid nodules, all of which were confirmed by pathology after surgery or FNA from January 2019 to January 2020, was carried out. All nodules were divided into a ⩽ 5 mm group and a > 5 mm group according to their maximum size. We compared the differences in the gray scale and elastography of the nodules between the two groups and the accuracy of different diagnostic methods. RESULTS: The accuracies of gray-scale ultrasound and shear wave elastography in the ⩽ 5 mm group were found to be lower than those in the > 5 mm group, and the gray-scale accuracy was slightly higher than that of shear wave elastography in both groups (p< 0.05). The largest AUC (area under the curve) of elastic parameters in the ⩽ 5 mm and > 5 mm groups was found for Emax and Esd, respectively. Based on a combination of these two parameters, the accuracies of the two groups were significantly higher than those of the parameters or gray scale alone (p< 0.05) and were 84.62% and 85.48%, respectively. CONCLUSION: Shear wave elastography is valuable in the diagnosis of benign and malignant thyroid nodules using ultrasonography. When combining gray-scale ultrasound and shear wave elastography, the diagnostic accuracy is obviously improved, especially for ⩽ 5 mm small thyroid nodules.
- 1 April 2011
- Published by SAGE Publications in Acta Radiologica
- Vol. 52 (3) , 248-255
Contrast-enhanced ultrasonographic findings of different histopathologic types of breast cancer
Background The new application of contrast-enhanced ultrasonography (CEUS) in the diagnosis of breast masses has evolved quickly only in recent years. Nevertheless, mixed results owing to the overlap in characteristics of benign and malignant lesions are simultaneously discovered by most studies, partially attributed to different histopathologic characteristics of breast cancer. Purpose To explore the characteristics of different histopathologic types of breast cancer at real-time gray-scale CEUS and evaluate its diagnostic value. Material and Methods One hundred and one histopathologically confirmed malignant lesions were included. We retrospectively reviewed the contrast-enhanced ultrasonographic findings including morphologic features, quantitative parameters, and correlated them with histopathology. True-positive rate was calculated to assess the diagnostic performance of CEUS. Results The 101 malignancies displayed irregular shape (72 [71%]), poorly-defined margin (73 [72%]), penetrating or tortuous surrounding vessels (79 [78%]), heterogeneous enhancement (84 [83%]), including focal perfusion defects (24 [24%]). For each histopathologic type, 87% (58/67) of invasive ductal carcinoma (IDC) showed heterogeneous enhancement. Of all the 24 perfusion defects, IDC account for 88% (21/24). Low average peak intensity (PI) of 4.9 was detected in this type. Ductal carcinoma in situ (DCIS) excellently showed the features of irregular shape (82% [14/17]), poorly-defined margin (82% [14/17]), heterogeneous enhancement (94% [16/17]). While 83% (5/6) of medullary carcinoma exhibited regular shape, well-defined margin, homogenous enhancement, and high average PI value of 9.6. Invasive lobular carcinoma showed similar enhancement pattern to that of IDC. Intraductal papillary carcinoma displayed high average PI value of 8.1. The overall true-positive rate for conventional US and CEUS was 88%, 86%, respectively. DCIS, medullary carcinoma, and intraductal papillary carcinoma achieved an improved true-positive rate (94%, 100% and 100%, respectively). Conclusion The imaging characteristics of CEUS are variable in different histopathologic types of breast cancer. CEUS does not appear to be superior to conventional ultrasound as a diagnostic tool overall, however, it is a useful adjunct to conventional ultrasound in diagnosing some special types of breast cancer.
- 1 April 2011
- Published by SAGE Publications in Acta Radiologica
- Vol. 52 (3) , 248-255
Contrast-enhanced ultrasonographic findings of different histopathologic types of breast cancer
Background The new application of contrast-enhanced ultrasonography (CEUS) in the diagnosis of breast masses has evolved quickly only in recent years. Nevertheless, mixed results owing to the overlap in characteristics of benign and malignant lesions are simultaneously discovered by most studies, partially attributed to different histopathologic characteristics of breast cancer. Purpose To explore the characteristics of different histopathologic types of breast cancer at real-time gray-scale CEUS and evaluate its diagnostic value. Material and Methods One hundred and one histopathologically confirmed malignant lesions were included. We retrospectively reviewed the contrast-enhanced ultrasonographic findings including morphologic features, quantitative parameters, and correlated them with histopathology. True-positive rate was calculated to assess the diagnostic performance of CEUS. Results The 101 malignancies displayed irregular shape (72 [71%]), poorly-defined margin (73 [72%]), penetrating or tortuous surrounding vessels (79 [78%]), heterogeneous enhancement (84 [83%]), including focal perfusion defects (24 [24%]). For each histopathologic type, 87% (58/67) of invasive ductal carcinoma (IDC) showed heterogeneous enhancement. Of all the 24 perfusion defects, IDC account for 88% (21/24). Low average peak intensity (PI) of 4.9 was detected in this type. Ductal carcinoma in situ (DCIS) excellently showed the features of irregular shape (82% [14/17]), poorly-defined margin (82% [14/17]), heterogeneous enhancement (94% [16/17]). While 83% (5/6) of medullary carcinoma exhibited regular shape, well-defined margin, homogenous enhancement, and high average PI value of 9.6. Invasive lobular carcinoma showed similar enhancement pattern to that of IDC. Intraductal papillary carcinoma displayed high average PI value of 8.1. The overall true-positive rate for conventional US and CEUS was 88%, 86%, respectively. DCIS, medullary carcinoma, and intraductal papillary carcinoma achieved an improved true-positive rate (94%, 100% and 100%, respectively). Conclusion The imaging characteristics of CEUS are variable in different histopathologic types of breast cancer. CEUS does not appear to be superior to conventional ultrasound as a diagnostic tool overall, however, it is a useful adjunct to conventional ultrasound in diagnosing some special types of breast cancer.