ZEZeeshan

Zeeshan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zeeshan has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Electric-Field-Assisted Enrichment and Electrochemical Detection of Gram-Positive Bacteria Using an FEM-Guided Interdigitated Electrode Biosensor

    by Zeeshan, Naeem Iqbal, Jaeyoung Choi

    Dielectrophoretic (DEP) enrichment is a powerful strategy to enhance bacterial capture efficiency and accelerate the response of electrochemical biosensors by actively concentrating target bioparticles at the sensing interface. In this study, a combined numerical–experimental framework is developed to rationally design a DEP-assisted electrochemical biosensor with improved bacterial capture and detection performance. A finite-element modeling (FEM) approach was used to model the coupled electric field, dielectrophoretic force, and particle-transport phenomena, providing a quantitative basis for comparing bacterial trapping efficiency across different interdigitated electrode geometries. The modeling reveals that a wave-shaped interdigitated electrode (W_IDE) generates extended high-field regions and an enlarged effective capture area, resulting in an improved bacterial capture efficiency of 19% compared to 12% for the conventional rectangular interdigitated electrodes (R_IDE) under positive DEP (pDEP) conditions. Based on these insights, the W_IDE was fabricated on a printed circuit board (PCB) substrate, modified with platinum-black (Pt-black) to increase electroactive surface area, and interfaced with a custom-built 16-channel portable potentiostat unit, enabling sequential impedance measurements. The developed biosensor was applied to pDEP-assisted impedance detection of Staphylococcus aureus and Micrococcus luteus using vancomycin as the capture probe. The pDEP-assisted operation enabled rapid and highly sensitive detection down to 10 CFU/mL within 30 min with a wide linear range (10–105 CFU/mL) in 0.1× PBS, outperforming passive detection (102–105 CFU/mL) for both Staphylococcus aureus and Micrococcus luteus. In skim milk, however, the linear detection ranges shifted to 102–105 CFU/mL with pDEP-assisted detection and 103–105 CFU/mL under passive detection conditions. Overall, this work highlights the significance of combining FEM-optimized electrodes with DEP-driven enrichment to achieve improved bacterial capture, sensitivity, and robustness in electrochemical biosensors.

  • Open Access

    Dielectrophoretic Enrichment Coupled with Impedance Spectroscopy for Real-Time Bacterial Detection and Antibiotic Susceptibility Testing Using an Interdigitated Wave Electrode Array

    by Zeeshan, Naeem Iqbal

    Antimicrobial resistance (AMR), largely driven by the inappropriate and excessive use of antibiotics, requires rapid and reliable bacterial detection and antibiotic susceptibility testing (AST), as conventional culture-based methods remain time-intensive. Here, we report a real-time, label-free interdigitated wave electrode array (IWEA) that combines dielectrophoretic (DEP) enrichment with impedance spectroscopy for rapid bacterial detection and AST. The proposed IWEA was designed and optimized via COMSOL Multiphysics to enhance DEP-relevant electric-field strength, thereby improving DEP-assisted bacterial enrichment compared to conventional planar interdigitated electrodes. The platform enabled sensitive detection of both Gram-positive (Staphylococcus aureus) and Gram-negative (Escherichia coli) in 0.1× PBS across 10–105 CFU/mL within 30 min using DEP-assisted preconcentration (100 kHz, 10 Vpp), outperforming passive (non-DEP) operation (102–105 CFU/mL). For AST, bacterial responses to vancomycin, gentamicin, and ampicillin were monitored through impedance variations following DEP-based enrichment. Susceptible bacteria produced concentration-dependent reductions in ΔZ/Z0, whereas resistant bacteria showed similar responses to untreated controls. Quantitative assessment yielded CC50 values of 2.86 ± 0.22 µg/mL and 3.06 ± 0.20 µg/mL for vancomycin and gentamicin against S. aureus, and 4.59 ± 0.30 µg/mL for gentamicin against E. coli. Resistance profiles of S. aureus to ampicillin and E. coli to vancomycin and ampicillin were clearly distinguished. SEM imaging and disk diffusion assays independently validated the impedance-derived susceptibility results. Collectively, this IWEA platform offers a rapid, label-free, and quantitative approach for bacterial detection and AST, with strong potential for antimicrobial screening and point-of-care diagnostics.

  • Open Access

    Design and Fabrication of a Robust Chitosan/Polyvinyl Alcohol-Based Humidity Sensor energized by a Piezoelectric Generator

    by Zeeshan, Afaque Manzoor Soomro, Sungbo Cho

    Due to their rapid growth in industrial and environmental applications, there is a need to develop self-powered humidity sensor systems with improved sensitivity, a wide detection range, and an eco-friendly nature. In this study, an aqueous solution of chitosan (CS) and polyvinyl alcohol (PVA) was blended to yield a composite film material with enhanced humidity detection properties. Meanwhile, a polyvinylidene difluoride (PVDF)-loaded chitosan composite film was developed and employed as a piezoelectric generator. Moreover, the developed composite materials for both devices (the piezoelectric generator and the humidity sensor) were optimized based on output performance. The piezoelectric generator generates a maximum of 16.2 V when a force of 10 N is applied and works as a power source for the humidity-sensing film. The sensing film swells in response to changes in relative humidity, which affects film resistance. This change in resistance causes a change in voltage through the piezoelectric generator and allows the precise measurement of relative humidity (RH). The fabricated sensor showed a linear response (R2 = 0.981) with a reasonable sensitivity (0.23 V/% RH) in an environment with an RH range of 21–89%. In addition, the device requires no external power, and therefore, it has numerous sensing applications in various fields.