James P. Schmiedeler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
James P. Schmiedeler has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Satyajit Ambike
Department of Health and Kinesiology, Purdue University, West Lafayette, USA
6 shared publications - Patrick M. Wensing
University of Notre Dame
5 shared publications - Andrew P. Murray
University of Dayton, Dayton, OH 45469
3 shared publications - Kai Zhao
Magna Seating of America, Novi, MI 48335
3 shared publications - Andrew Peter Murray
University of Dayton
2 shared publications - Anthony Luscher
Department of Mechanical and Aerospace Engineering, The Ohio State University, Columbus, OH 43210, USA
2 shared publications
Latest Publications
- 23 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (6) , 7855-7865
Extending the Benefits of Parallel Elasticity Across Multiple Actuation Tasks: A Geometric and Optimization-Based Approach
A spring in parallel with an effort source (e.g., electric motor or human muscle) can reduce its energy consumption and effort (i.e., torque or force) depending on the spring stiffness, spring preload, and actuation task. However, selecting the spring stiffness and preload that guarantees effort or energy reduction for an arbitrary set of tasks is a design challenge. This work formulates a convex optimization problem to guarantee that a parallel spring reduces the root-mean-square source effort or energy consumption for multiple tasks. Specifically, we guarantee the benefits across multiple tasks by enforcing a set of convex quadratic constraints in our optimization variables, the parallel spring stiffness and preload. These quadratic constraints are equivalent to ellipses in the stiffness and preload plane; any combination of stiffness and preload inside the ellipse represents a parallel spring that minimizes effort source or energy consumption with respect to an actuator without a spring. This geometric interpretation intuitively guides the stiffness and preload selection process. We analytically and experimentally prove the convex quadratic function of the spring stiffness and preload. As applications, we analyze the stiffness and preload selection of a parallel spring for a knee exoskeleton using human muscle as the effort source and a prosthetic ankle powered by electric motors. The source code associated with our framework is available as supplemental open-source software.
- 23 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (6) , 7855-7865
Extending the Benefits of Parallel Elasticity Across Multiple Actuation Tasks: A Geometric and Optimization-Based Approach
A spring in parallel with an effort source (e.g., electric motor or human muscle) can reduce its energy consumption and effort (i.e., torque or force) depending on the spring stiffness, spring preload, and actuation task. However, selecting the spring stiffness and preload that guarantees effort or energy reduction for an arbitrary set of tasks is a design challenge. This work formulates a convex optimization problem to guarantee that a parallel spring reduces the root-mean-square source effort or energy consumption for multiple tasks. Specifically, we guarantee the benefits across multiple tasks by enforcing a set of convex quadratic constraints in our optimization variables, the parallel spring stiffness and preload. These quadratic constraints are equivalent to ellipses in the stiffness and preload plane; any combination of stiffness and preload inside the ellipse represents a parallel spring that minimizes effort source or energy consumption with respect to an actuator without a spring. This geometric interpretation intuitively guides the stiffness and preload selection process. We analytically and experimentally prove the convex quadratic function of the spring stiffness and preload. As applications, we analyze the stiffness and preload selection of a parallel spring for a knee exoskeleton using human muscle as the effort source and a prosthetic ankle powered by electric motors. The source code associated with our framework is available as supplemental open-source software.
- 13 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics & Automation Magazine
- Vol. 31 (2) , 135-140
The Next Generation of Robotics: The 2023 IEEE/RSJ International Conference on Intelligent Robots and Systems in Detroit, MI, USA [Conference Highlights]
The 2023 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2023) was held on 1–5 October at Huntington Place in Detroit, MI, USA ( Figure 1 ). With the COVID-19 pandemic shifting IROS 2020 entirely to the on-demand format, this was the first in-person IROS in North America in six years. The long-term impact of the pandemic also meant that it was the first in-person conference of any kind for many of the student attendees. IROS 2023’s theme, “The Next Generation of Robotics,” reinforced the importance of these students within the IROS community, so we made the conscious effort to prioritize the in-person experience for those among the more than 3,600 attendees from 53 countries and regions who were able to join us in person in Detroit.
- 13 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics & Automation Magazine
- Vol. 31 (2) , 135-140
The Next Generation of Robotics: The 2023 IEEE/RSJ International Conference on Intelligent Robots and Systems in Detroit, MI, USA [Conference Highlights]
The 2023 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2023) was held on 1–5 October at Huntington Place in Detroit, MI, USA ( Figure 1 ). With the COVID-19 pandemic shifting IROS 2020 entirely to the on-demand format, this was the first in-person IROS in North America in six years. The long-term impact of the pandemic also meant that it was the first in-person conference of any kind for many of the student attendees. IROS 2023’s theme, “The Next Generation of Robotics,” reinforced the importance of these students within the IROS community, so we made the conscious effort to prioritize the in-person experience for those among the more than 3,600 attendees from 53 countries and regions who were able to join us in person in Detroit.
- Open Access
- 7 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 1210-1220
Lower-Limb Myoelectric Calibration Postures for Transtibial Prostheses
The use of an agonist-antagonist muscle pair for myoelectric control of a transtibial prosthesis requires normalizing the myoelectric signals and identifying their co-contraction signature. Extensive literature has explored the relationship between body posture and lower-limb muscle activation level using surface electromyography (EMG), but it is unknown how these relationships hold after amputation. Using a virtual tracking task, this study compares the effect of three different calibration postures (seated, standing, dynamic) on user tracking ability while in two tracking postures (seated, standing) for 18 able-bodied (AB) subjects and 9 subjects with transtibial (TT) amputation. As expected, AB subjects produced statistically significant differences in muscle activation for gastrocnemius (GAS) when seated vs. standing during calibration (p = 8.8e-4), but not for tibialis anterior (TA) (p = 0.76). TT subjects, however, showed no significant differences in GAS or TA between seated and standing (p = 0.90, 0.60 respectively). It was also determined that normalizing EMG by the global maximum signal observed (standard in biomechanic analysis) is undesirable for myoelectric control. For best general results with this framework, calibration in both seated and dynamic postures is recommended, taking the normalization information from the seated posture and the narrowest co-contraction slopes from the two.
- 7 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 1210-1220
Open AccessLower-Limb Myoelectric Calibration Postures for Transtibial Prostheses
The use of an agonist-antagonist muscle pair for myoelectric control of a transtibial prosthesis requires normalizing the myoelectric signals and identifying their co-contraction signature. Extensive literature has explored the relationship between body posture and lower-limb muscle activation level using surface electromyography (EMG), but it is unknown how these relationships hold after amputation. Using a virtual tracking task, this study compares the effect of three different calibration postures (seated, standing, dynamic) on user tracking ability while in two tracking postures (seated, standing) for 18 able-bodied (AB) subjects and 9 subjects with transtibial (TT) amputation. As expected, AB subjects produced statistically significant differences in muscle activation for gastrocnemius (GAS) when seated vs. standing during calibration (p = 8.8e-4), but not for tibialis anterior (TA) (p = 0.76). TT subjects, however, showed no significant differences in GAS or TA between seated and standing (p = 0.90, 0.60 respectively). It was also determined that normalizing EMG by the global maximum signal observed (standard in biomechanic analysis) is undesirable for myoelectric control. For best general results with this framework, calibration in both seated and dynamic postures is recommended, taking the normalization information from the seated posture and the narrowest co-contraction slopes from the two.
- Open Access
- 20 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 2778-2788
Finite-State Impedance and Direct Myoelectric Control for Robotic Ankle Prostheses: Comparing Their Performance and Exploring Their Combination
Non-volitional control, such as finite-state machine (FSM) impedance control, does not directly incorporate user intent signals, while volitional control, like direct myoelectric control (DMC), relies on these signals. This paper compares the performance, capabilities, and perception of FSM impedance control to DMC on a robotic prosthesis for subjects with and without transtibial amputation. It then explores, using the same metrics, the feasibility and performance of the combination of FSM impedance control and DMC across the full gait cycle, termed Hybrid Volitional Control (HVC). After calibration and acclimation with each controller, subjects walked for two minutes, explored the control capabilities, and completed a questionnaire. FSM impedance control produced larger average peak torque (1.15Nm/kg) and power (2.05 W/kg) than DMC (0.88 Nm/kg and 0.94 W/kg). The discrete FSM, however, caused non-standard kinetic and kinematic trajectories, while DMC yielded trajectories qualitatively more similar to able-bodied biomechanics. While walking with HVC, all subjects successfully achieved ankle push-off and were able to modulate the magnitude of push-off via the the volitional input. Unexpectedly, however, HVC behaved either more similarly to FSM impedance control or to DMC alone, rather than in combination. Both DMC and HVC, but not FSM impedance control, allowed subjects to achieve unique activities such as tip-toe standing, foot tapping, side-stepping, and backward walking. Able-bodied subject (N=6) preferences were split amongst the controllers, while all transtibial subjects (N=3) preferred DMC. Desired performance and ease of use showed the highest correlations with overall satisfaction (0.81 and 0.82, respectively).
- 20 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 2778-2788
Open AccessFinite-State Impedance and Direct Myoelectric Control for Robotic Ankle Prostheses: Comparing Their Performance and Exploring Their Combination
Non-volitional control, such as finite-state machine (FSM) impedance control, does not directly incorporate user intent signals, while volitional control, like direct myoelectric control (DMC), relies on these signals. This paper compares the performance, capabilities, and perception of FSM impedance control to DMC on a robotic prosthesis for subjects with and without transtibial amputation. It then explores, using the same metrics, the feasibility and performance of the combination of FSM impedance control and DMC across the full gait cycle, termed Hybrid Volitional Control (HVC). After calibration and acclimation with each controller, subjects walked for two minutes, explored the control capabilities, and completed a questionnaire. FSM impedance control produced larger average peak torque (1.15Nm/kg) and power (2.05 W/kg) than DMC (0.88 Nm/kg and 0.94 W/kg). The discrete FSM, however, caused non-standard kinetic and kinematic trajectories, while DMC yielded trajectories qualitatively more similar to able-bodied biomechanics. While walking with HVC, all subjects successfully achieved ankle push-off and were able to modulate the magnitude of push-off via the the volitional input. Unexpectedly, however, HVC behaved either more similarly to FSM impedance control or to DMC alone, rather than in combination. Both DMC and HVC, but not FSM impedance control, allowed subjects to achieve unique activities such as tip-toe standing, foot tapping, side-stepping, and backward walking. Able-bodied subject (N=6) preferences were split amongst the controllers, while all transtibial subjects (N=3) preferred DMC. Desired performance and ease of use showed the highest correlations with overall satisfaction (0.81 and 0.82, respectively).
- 2 August 2022
- Published by Springer Nature in Autonomous Robots
- Vol. 46 (7) , 831-849
A unified framework for measuring interplane and intraplane coupling in spatial biped robots
- 2 August 2022
- Published by Springer Nature in Autonomous Robots
- Vol. 46 (7) , 831-849
A unified framework for measuring interplane and intraplane coupling in spatial biped robots
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2019, 471-476
Characterizing Intent Changes in Exoskeleton-Assisted Walking Through Onboard Sensors
Robotic exoskeletons are a promising technology for rehabilitation and locomotion following musculoskeletal injury, but their adoption outside the physical therapy clinic has been limited by relatively primitive methods for identifying and incorporating the user’s gait intentions. Various intent detection approaches have been demonstrated using electromyography and electroencephalography signals. These technologies sense the human directly but introduce complications for donning/doffing the device and in measurement consistency. By contrast, sensors onboard the exoskeleton avoid these complications but sense the human indirectly via the human-robot interface. This pilot study examines if onboard sensors alone may enable identification of user intent. Joint positions and commanded motor currents are compared prior to and after changes in the user’s intended gait speed. Preliminary experimental results confirm that these measures are significantly different following intent changes for both able-bodied and non-able-bodied users. The findings suggest that intent detection is possible with onboard sensors alone, but the intent signals depend on exoskeleton control settings, user ability, and temporal considerations.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2019, 471-476
Characterizing Intent Changes in Exoskeleton-Assisted Walking Through Onboard Sensors
Robotic exoskeletons are a promising technology for rehabilitation and locomotion following musculoskeletal injury, but their adoption outside the physical therapy clinic has been limited by relatively primitive methods for identifying and incorporating the user’s gait intentions. Various intent detection approaches have been demonstrated using electromyography and electroencephalography signals. These technologies sense the human directly but introduce complications for donning/doffing the device and in measurement consistency. By contrast, sensors onboard the exoskeleton avoid these complications but sense the human indirectly via the human-robot interface. This pilot study examines if onboard sensors alone may enable identification of user intent. Joint positions and commanded motor currents are compared prior to and after changes in the user’s intended gait speed. Preliminary experimental results confirm that these measures are significantly different following intent changes for both able-bodied and non-able-bodied users. The findings suggest that intent detection is possible with onboard sensors alone, but the intent signals depend on exoskeleton control settings, user ability, and temporal considerations.
- 22 February 2019
- Published by ASME International in Journal of Mechanisms and Robotics
- Vol. 11 (2)
Velocity Decomposition-Enhanced Control for Point and Curved-Foot Planar Bipeds Experiencing Velocity Disturbances
This paper extends the use of velocity decomposition of underactuated mechanical systems to the design of an enhanced hybrid zero dynamics (HZD)-based controller for biped robots. To reject velocity disturbances in the unactuated degree-of-freedom, a velocity decomposition-enhanced controller implements torso and leg offsets that are proportional to the error in the time derivative of the unactuated velocity. The offsets are layered on top of an HZD-based controller to preserve simplicity of implementation. Simulation results with a point-foot, three-link planar biped show that the proposed method has nearly identical performance to transverse linearization feedback control and outperforms conventional HZD-based control. Curved feet are implemented in simulation and show that the proposed control method is valid for both point-foot and curved-foot planar bipeds. Performance of each controller is assessed by (1) the magnitude of the disturbance it can reject by numerically computing the basin of attraction, (2) the speed of return to nominal step velocity following a disturbance at every point of the gait cycle, and (3) the energetic efficiency, which is measured via the specific cost of transport. Several gaits are analyzed to demonstrate that the observed trends are consistent across different walking speeds.
- 22 February 2019
- Published by ASME International in Journal of Mechanisms and Robotics
- Vol. 11 (2)
Velocity Decomposition-Enhanced Control for Point and Curved-Foot Planar Bipeds Experiencing Velocity Disturbances
This paper extends the use of velocity decomposition of underactuated mechanical systems to the design of an enhanced hybrid zero dynamics (HZD)-based controller for biped robots. To reject velocity disturbances in the unactuated degree-of-freedom, a velocity decomposition-enhanced controller implements torso and leg offsets that are proportional to the error in the time derivative of the unactuated velocity. The offsets are layered on top of an HZD-based controller to preserve simplicity of implementation. Simulation results with a point-foot, three-link planar biped show that the proposed method has nearly identical performance to transverse linearization feedback control and outperforms conventional HZD-based control. Curved feet are implemented in simulation and show that the proposed control method is valid for both point-foot and curved-foot planar bipeds. Performance of each controller is assessed by (1) the magnitude of the disturbance it can reject by numerically computing the basin of attraction, (2) the speed of return to nominal step velocity following a disturbance at every point of the gait cycle, and (3) the energetic efficiency, which is measured via the specific cost of transport. Several gaits are analyzed to demonstrate that the observed trends are consistent across different walking speeds.
- Open Access
- 21 May 2018
- Published by ASME International in Journal of Manufacturing Science and Engineering
- Vol. 140 (8)
Control of Final Part Dimensions in Polymer Extrusion Using a Variable-Geometry Die
Parts made via polymer extrusion are currently limited to a constant cross section. Additionally, the process is difficult to control, so desired final part dimensions are often achieved via a manual trial-and-error approach to parameter adjustment. This work seeks to increase the capability of polymer extrusion by using iterative learning control (ILC) to regulate the final width of a rectangular part through changing the width of a simple variable-geometry die. Simulation results determine the appropriateness of the learning algorithm and gains to be used in experiment. A prototype die on a production extruder was used to demonstrate the effectiveness of the approach. These experiments achieved automated control over both gross change in shape and final part dimension when the puller speed was held constant, which has not been seen previously in the literature.
- 21 May 2018
- Published by ASME International in Journal of Manufacturing Science and Engineering
- Vol. 140 (8)
Open AccessControl of Final Part Dimensions in Polymer Extrusion Using a Variable-Geometry Die
Parts made via polymer extrusion are currently limited to a constant cross section. Additionally, the process is difficult to control, so desired final part dimensions are often achieved via a manual trial-and-error approach to parameter adjustment. This work seeks to increase the capability of polymer extrusion by using iterative learning control (ILC) to regulate the final width of a rectangular part through changing the width of a simple variable-geometry die. Simulation results determine the appropriateness of the learning algorithm and gains to be used in experiment. A prototype die on a production extruder was used to demonstrate the effectiveness of the approach. These experiments achieved automated control over both gross change in shape and final part dimension when the puller speed was held constant, which has not been seen previously in the literature.
- 1 January 2018
- Published by ASME International in Applied Mechanics Reviews
- Vol. 70 (1)
Discussion of “A Review of Intent Detection, Arbitration, and Communication Aspects of Shared Control for Physical Human–Robot Interaction” (Losey, D. P., McDonald, C. G., Battaglia, E., and O'Malley, M. K., 2018, ASME Appl. Mech. Rev., 70(1), p. 010804)
A unifying description of the shared control architecture within the field of physical human–robot interaction (pHRI) facilitates the education of those being introduced to the field and the framing of new contributions to it. The authors' review of shared control within pHRI proposes such a unifying framework composed of three pillars. First, intent detection addresses the robot's interpretation of human goals, representing one-way communication. Second, arbitration manages the respective roles of the human and robot in the shared control. Third, feedback is the mechanism by which the robot returns information to the human, representing one-way communication in the opposite direction. Interpreting existing contributions through the lens of this framework brings out the importance of mechanical design, modeling, and state-based control.
- 1 January 2018
- Published by ASME International in Applied Mechanics Reviews
- Vol. 70 (1)
Discussion of “A Review of Intent Detection, Arbitration, and Communication Aspects of Shared Control for Physical Human–Robot Interaction” (Losey, D. P., McDonald, C. G., Battaglia, E., and O'Malley, M. K., 2018, ASME Appl. Mech. Rev., 70(1), p. 010804)
A unifying description of the shared control architecture within the field of physical human–robot interaction (pHRI) facilitates the education of those being introduced to the field and the framing of new contributions to it. The authors' review of shared control within pHRI proposes such a unifying framework composed of three pillars. First, intent detection addresses the robot's interpretation of human goals, representing one-way communication. Second, arbitration manages the respective roles of the human and robot in the shared control. Third, feedback is the mechanism by which the robot returns information to the human, representing one-way communication in the opposite direction. Interpreting existing contributions through the lens of this framework brings out the importance of mechanical design, modeling, and state-based control.
- 9 March 2017
- Published by ASME International in Journal of Mechanisms and Robotics
- Vol. 9 (2) , 021009
Simultaneous Topological and Dimensional Synthesis of Planar Morphing Mechanisms
This paper presents a general method to perform simultaneous topological and dimensional synthesis for planar rigid-body morphing mechanisms. The synthesis is framed as a multi-objective optimization problem for which the first objective is to minimize the error in matching the desired shapes. The second objective is typically to minimize the actuating force/moment required to move the mechanism, but different applications may require a different choice. All the possible topologies are enumerated for morphing mechanism designs with a specified number of degrees of freedom (DOF), and infeasible topologies are removed from the search space. A multi-objective genetic algorithm (GA) is then used to simultaneously handle the discrete nature of the topological optimization and the continuous nature of the dimensional optimization. In this way, candidate solutions from any of the feasible topologies enumerated can be evaluated and compared. Ultimately, the method yields a sizable population of viable solutions, often of different topologies, so that the designer can manage engineering tradeoffs in selecting the best mechanism. Three examples illustrate the strengths of this method. The first examines the advantages gained by considering and optimizing across all the topologies simultaneously. The second and third demonstrate the method's versatility by incorporating prismatic joints into the morphing chain to allow for morphing between shapes that have significant changes in both shape and arc length.
- 9 March 2017
- Published by ASME International in Journal of Mechanisms and Robotics
- Vol. 9 (2) , 021009
Simultaneous Topological and Dimensional Synthesis of Planar Morphing Mechanisms
This paper presents a general method to perform simultaneous topological and dimensional synthesis for planar rigid-body morphing mechanisms. The synthesis is framed as a multi-objective optimization problem for which the first objective is to minimize the error in matching the desired shapes. The second objective is typically to minimize the actuating force/moment required to move the mechanism, but different applications may require a different choice. All the possible topologies are enumerated for morphing mechanism designs with a specified number of degrees of freedom (DOF), and infeasible topologies are removed from the search space. A multi-objective genetic algorithm (GA) is then used to simultaneously handle the discrete nature of the topological optimization and the continuous nature of the dimensional optimization. In this way, candidate solutions from any of the feasible topologies enumerated can be evaluated and compared. Ultimately, the method yields a sizable population of viable solutions, often of different topologies, so that the designer can manage engineering tradeoffs in selecting the best mechanism. Three examples illustrate the strengths of this method. The first examines the advantages gained by considering and optimizing across all the topologies simultaneously. The second and third demonstrate the method's versatility by incorporating prismatic joints into the morphing chain to allow for morphing between shapes that have significant changes in both shape and arc length.