CZChristopher Thomas Zoppo

Christopher Thomas Zoppo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Christopher Thomas Zoppo has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Case for Automated Segmentation of MRI Data in Neurodegenerative Diseases: Type II GM1 Gangliosidosis

    by Connor J. Lewis, Jean M. Johnston, Precilla D’souza, Josephine Kolstad, Christopher Zoppo, Zeynep Vardar, Anna Luisa Kühn, Ahmet Peker, Zubir S. Rentiya, Muhammad H. Yousef, et al.

    Background: Volumetric analysis and segmentation of magnetic resonance imaging (MRI) data is an important tool for evaluating neurological disease progression and neurodevelopment. Fully automated segmentation pipelines offer faster and more reproducible results. However, since these analysis pipelines were trained on or run based on atlases consisting of neurotypical controls, it is important to evaluate how accurate these methods are for neurodegenerative diseases. In this study, we compared five fully automated segmentation pipelines, including FSL, Freesurfer, volBrain, SPM12, and SimNIBS, with a manual segmentation process in GM1 gangliosidosis patients and neurotypical controls. Methods: We analyzed 45 MRI scans from 16 juvenile GM1 gangliosidosis patients, 11 MRI scans from 8 late-infantile GM1 gangliosidosis patients, and 19 MRI scans from 11 neurotypical controls. We compared the results for seven brain structures, including volumes of the total brain, bilateral thalamus, ventricles, bilateral caudate nucleus, bilateral lentiform nucleus, corpus callosum, and cerebellum. Results: We found volBrain’s vol2Brain pipeline to have the strongest correlations with the manual segmentation process for the whole brain, ventricles, and thalamus. We also found Freesurfer’s recon-all pipeline to have the strongest correlations with the manual segmentation process for the caudate nucleus. For the cerebellum, we found a combination of volBrain’s vol2Brain and SimNIBS’ headreco to have the strongest correlations, depending on the cohort. For the lentiform nucleus, we found a combination of recon-all and FSL’s FIRST to give the strongest correlations, depending on the cohort. Lastly, we found segmentation of the corpus callosum to be highly variable. Conclusions: Previous studies have considered automated segmentation techniques to be unreliable, particularly in neurodegenerative diseases. However, in our study, we produced results comparable to those obtained with a manual segmentation process. While manual segmentation processes conducted by neuroradiologists remain the gold standard, we present evidence to the capabilities and advantages of using an automated process that includes the ability to segment white matter throughout the brain or analyze large datasets, which pose feasibility issues to fully manual processes. Future investigations should consider the use of artificial intelligence-based segmentation pipelines to determine their accuracy in GM1 gangliosidosis, lysosomal storage disorders, and other neurodegenerative diseases.


  • Open Access

    Surface modification of neurovascular stents: from bench to patient

    by Christopher T Zoppo, J Mocco, Nathan W Manning, Alexei A Bogdanov, Matthew J Gounis

    Flow-diverting stents (FDs) for the treatment of cerebrovascular aneurysms are revolutionary. However, these devices require systemic dual antiplatelet therapy (DAPT) to reduce thromboembolic complications. Given the risk of ischemic complications as well as morbidity and contraindications associated with DAPT, demonstrating safety and efficacy for FDs either without DAPT or reducing the duration of DAPT is a priority. The former may be achieved by surface modifications that decrease device thrombogenicity, and the latter by using coatings that expedite endothelial growth. Biomimetics, commonly achieved by grafting hydrophilic and non-interacting polymers to surfaces, can mask the device surface with nature-derived coatings from circulating factors that normally activate coagulation and inflammation. One strategy is to mimic the surfaces of innocuous circulatory system components. Phosphorylcholine and glycan coatings are naturally inspired and present on the surface of all eukaryotic cell membranes. Another strategy involves linking synthetic biocompatible polymer brushes to the surface of a device that disrupts normal interaction with circulating proteins and cells. Finally, drug immobilization can also impart antithrombotic effects that counteract normal foreign body reactions in the circulatory system without systemic effects. Heparin coatings have been explored since the 1960s and used on a variety of blood contacting surfaces. This concept is now being explored for neurovascular devices. Coatings that improve endothelialization are not as clinically mature as anti-thrombogenic coatings. Coronary stents have used an anti-CD34 antibody coating to capture circulating endothelial progenitor cells on the surface, potentially accelerating endothelial integration. Similarly, coatings with CD31 analogs are being explored for neurovascular implants.


  • A novel intrasaccular aneurysm device with high complete occlusion rate: initial results in a rabbit model

    by Christopher T Zoppo, Josephine W Kolstad, Robert M King, Thomas Wolfe, Afif Kraitem, Zeynep Vardar, Aamir Badruddin, Edgard Pereira, Boris Pabón Guerrero, Arturo S Rosqueta, et al.

    Background Intrasaccular flow-disrupting devices are a safe and effective treatment strategy for intracranial aneurysms. We utilized high-frequency optical coherence tomography (HF-OCT) and digital subtraction angiography (DSA) to evaluate SEAL Arc, a new intrasaccular device, and compare the findings with the well-established Woven EndoBridge (WEB) device in an animal model of saccular aneurysms. Methods In a rabbit model, elastase-induced aneurysms were treated with SEAL Arc (n=11) devices. HF-OCT and DSA were performed after implant and repeated after 12 weeks. Device protrusion and malapposition were assessed at implant time and scored on a binary system. Aneurysm occlusion was assessed at 12 weeks with the WEB Occlusion Scale and dichotomized to complete (A and B) or incomplete (C and D) occlusion. The percentage of neointimal coverage after 12 weeks was quantified using HF-OCT. We compared these data to previously published historical controls treated with the gold-standard WEB device (n=24) in the same model. Results Aneurysm size and device placement were not significantly different between the two groups. Complete occlusion was demonstrated in 80% of the SEAL Arc devices, which compared favorably to the 21% of the aneurysms treated with WEB devices (P=0.002). Neointimal coverage across SEAL Arc devices was 86±15% compared with 49±27% for WEB (P=0.001). Protruding devices had significantly less neointimal coverage (PConclusion Complete early aneurysm occlusion was frequently observed in the SEAL Arc treated aneurysms, with significant neointimal coverage after 12 weeks.


  • I saw Medusa's head sign and turned to stone

    by Christopher Thomas Zoppo, Trenton Taros, Jasmeet Singh, Ajit Puri, Anna Luisa Kuhn

  • Longitudinal healing flow diverting stents with phosphorylcholine surface modification

    by Christopher T Zoppo, Mark Epshtein, Matthew J Gounis, Vania Anagnostakou, Robert M King

    Background Flow diversion has become a standard treatment for cerebral aneurysms. However, major drawbacks include the need for dual antiplatelet therapy after implant and delayed complete occlusion of the aneurysm, which occurs when new tissue growth excludes the aneurysm from the parent artery. Biomimetic surface modifications such as the phosphorylcholine polymer (Shield surface modification) represent major advances in reducing thrombogenicity of these devices. However, in vitro studies have raised concerns that this modification may also delay endothelialization of flow diverters. Methods Bare metal Pipeline, Pipeline Shield, and Vantage with Shield devices were implanted in the common carotid arteries (CCAs) of 10 rabbits (two in the left CCA, one in the right CCA). Following implant and at 5, 10, 15, and 30 days, the devices were imaged with high-frequency optical coherence tomography and conventional angiography to evaluate tissue growth. At 30 days the devices were explanted and their endothelial growth was assessed with scanning electron microscopy (SEM) at five locations along their length using a semi-quantitative score. Results The average tissue growth thickness (ATGT) was not different between the three devices. Neointima was apparent at 5 days and all devices demonstrated similar ATGT at each time point. On SEM, no difference was found in the endothelium scores between the device types. Conclusion In vivo, neither the Shield surface modification nor the device design (Vantage) altered the longitudinal healing of the flow diverter.


  • Open Access

    Top 50 most cited articles on prostatic artery embolization for benign prostatic hyperplasia: A bibliometric review

    by Christopher Thomas Zoppo, Trenton Taros, Aaron Harman

    Bibliometric analysis can be used to assess the current state of the literature and publication trends on a given topic. There has not been a review of this kind on prostatic artery embolization (PAE) for benign prostatic hyperplasia (BPH). PAE is a relatively new and somewhat controversial treatment option for BPH. Given the novelty and controversy, there has been much research published on the topic recently. To survey the current state of research on PAE for BPH by using bibliometric analysis to analyze the top 50 most highly cited articles. A cross-sectional study was performed using the Web of Science database to identify the most cited articles published on PAE for BPH as of June 2022. Articles that did not primarily focus on PAE or BPH as an indication were eliminated. The 50 most cited articles were carried forward for analysis. All but 6 articles were published in the last decade with contributions from 15 countries. Fifty-two percent of the studies had a C level of evidence. The majority were published in the Journal of Vascular and Interventional Radiology and Cardiovascular and Interventional Radiology. Twenty percent (n = 10) of the articles were published in urologic journals. On average, articles published in urologic journals tended to be more recent. The mean year of publication for an article in a urological journal was 2016.6 compared to 2013.9 in a non-urologic journal (P = 0.02). Seventy percent of the articles focused on clinical outcomes, while only 2% focused on practice guidelines. Self-citations accounted for 11.4 citations per article on average, corresponding to 14.7% of all citations analyzed. The most influential papers on this topic represent a fairly recent body of work with contributions from a wide variety of countries and journals. The fact that articles in urologic journals were published significantly more recently than articles on the list in non-urologic journals may suggest that the field of urology is starting to accept PAE for a wider range of indications. Finally, while there has been much high-quality research published, more influential studies on practice guidelines and technique may be beneficial.

  • Splenic Artery Embolization for Unstable Patients with Splenic Injury: A Retrospective Cohort Study

    by Christopher Zoppo, Daniel Alvarez Valero, Venkatesh Arumugam Murugan, Alex Pavidapha, Julie Flahive, Alex Newbury, Eleanor Fallon, Aaron Harman