Z. Chelli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Z. Chelli has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
A. Omeiri
Department of Electrical Engineering, University of Badji Mokhtar of Annaba, P.O. Box 12, 23000 Annaba, Algeria
1 shared publicationR. Toufouti
Department of Electrical Engineering, University of Mohamed-Cherif Messaadia of Souk Ahras, P.O. Box 1553, 41000 Souk Ahras, Algeria
1 shared publication- Salah Saad
Badji Mokhtar University
1 shared publication
Latest Publications
- Open Access
- 1 January 2015
- Published by Hindawi Limited in Journal of Electrical and Computer Engineering
- Vol. 2015, 1-9
Hysteresis Control for Shunt Active Power Filter under Unbalanced Three-Phase Load Conditions
This paper focuses on a four-wire shunt active power filter (APF) control scheme proposed to improve the performance of the APF. This filter is used to compensate harmonic distortion in three-phase four-wire systems. Several harmonic suppression techniques have been widely proposed and applied to minimize harmonic effects. The proposed control scheme can compensate harmonics and reactive power of the nonlinear loads simultaneously. This approach is compared to the conventional shunt APF reference compensation strategy. The developed algorithm is validated by simulation tests using MATLAB Simulink. The obtained results have demonstrated the effectiveness of the proposed scheme and confirmed the theoretical developments for balanced and unbalanced nonlinear loads.
- 1 January 2015
- Published by Hindawi Limited in Journal of Electrical and Computer Engineering
- Vol. 2015, 1-9
Open AccessHysteresis Control for Shunt Active Power Filter under Unbalanced Three-Phase Load Conditions
This paper focuses on a four-wire shunt active power filter (APF) control scheme proposed to improve the performance of the APF. This filter is used to compensate harmonic distortion in three-phase four-wire systems. Several harmonic suppression techniques have been widely proposed and applied to minimize harmonic effects. The proposed control scheme can compensate harmonics and reactive power of the nonlinear loads simultaneously. This approach is compared to the conventional shunt APF reference compensation strategy. The developed algorithm is validated by simulation tests using MATLAB Simulink. The obtained results have demonstrated the effectiveness of the proposed scheme and confirmed the theoretical developments for balanced and unbalanced nonlinear loads.