ACAlejandro Von Chong

Alejandro Von Chong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alejandro Von Chong has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    OpenMCT: an open-source DC motor control educational kit

    by Alejandro Von Chong, Salvador Vargas, Jean-François Duhé, Dorindo Cárdenas


  • Nouvelle approche pour l'estimation de la saturation en oxygène du sang artériel en utilisant un capteur multispectrale

    by Alejandro Von Chong Echevers

    Ce manuscrit présente les travaux réalisés pour la mise au point d’un système d’estimation du taux d’oxygénation connu aussi sous le nom d’oxymètre de pouls. Ledit outil est indispensable, notamment dans le domaine médical, pour la surveillance des patients lors des interventions anesthésiques, pour les soins post-opératoires et aux urgences puisqu’il fournit de l’information relative à l’efficacité respiratoire et au rythme cardiaque. Le principe d’opération de ce dernier est basé sur la différence en absorption optique entre le sang oxygéné et le sang désoxygéné à l’aide d’une photodiode simple comme moyen de détection. Dans ce travail de recherche, nous introduisons une nouvelle méthode basée sur la différence des spectres d’absorption entre le sang oxygéné et le sang désoxygéné en utilisant un photodétecteur multispectrale.En premier lieu, une introduction et une analyse de l’état de l’art sont faites afin de mieux comprendre la théorie derrière l’oxymétrie de pouls et de mettre en évidence les limitations des méthodes actuelles, ce qui nous permettra de positionner scientifiquement et techniquement les contributions. Ensuite, une explication détaillée du système conçu, concernant l’électronique, l’acquisition et traitement des signaux est décrite.Finalement, nous présentons les résultats obtenus avec la méthode proposée. D’abord, une preuve de concept à plusieurs longueurs d’onde a été faite avec un spectromètre comme moyen de détection afin de valider le principe de fonctionnement de notre méthode. Pour ce faire, nous avons effectué des tests de désoxygénation par rétention de la respiration conjointement avec un oxymètre de haute gamme comme moyen de comparaison. Une fois le principe validé, nous avons remplacé le spectromètre par un capteur multispectrale. Nous avons alors montré que les estimations faites avec notre méthode, en régime stable, tombaient dans la tolérance permise par la norme ISO régulant les oxymètres de pouls.Ces travaux ouvrent une voie alternative et complémentaire à l’étude de l’oxymétrie de pouls capable de surmonter plusieurs limitations présentes dans la technique conventionnelle, en particulier dans le cadre du design d’implants autonomes. Des essais cliniques à venir permettront d’approfondir sur l’utilité de cette méthode et ses limitations.

  • Open Access

    OpenCL: an open-source DC motor control educational kit

    by Alejandro Von Chong, Salvador Vargas, Jean-François Duhé, Dorindo Cárdenas

    Control engineering is used in multiple engineering domains, but most introductory courses lean heavily on mathematical manipulation and simulation. This can limit students’ exposure to real-world applications, often at the cost of student engagement. To promote a system-level approach, this work describes OpenMCT, a low-cost, open-source educational kit for DC motor control that enables hands-on experiments covering topics from actuation and sensing to sampling and real-time control execution, while also touching on other engineering topics students encounter in practice, such as drive electronics, measurement conditioning, and filtering. The hardware integrates a brushed DC motor, incremental encoder feedback, motor current sensing, and an H-bridge driver controlled by a Teensy 4 microcontroller. A cross-platform Python/Qt GUI provides configuration, live telemetry, excitation signals, data logging, and interactive controller tuning, including PID and direct entry of z-domain difference-equation coefficients. Validation follows the workflow commonly taught in control courses, going from calibration, characterization, and system identification through to controller design and deployment. Experimental results are validated using MATLAB-based tools, showing that system identification and closed-loop responses follow the trends predicted by MATLAB simulations.

  • Open Access

    Enhanced Visualization of Erythrocytes Through Photoluminescence Using NaYbF4:Yb3+,Er3+ Nanoparticles

    by Vivian Torres-Vera, Lorena M. Coronado, Ana Patricia Valencia, Alejandro Von Chong, Esteban Rua, Michelle Ng, Jorge Rubio-Retama, Carmenza Spadafora, Ricardo Correa

    Rare-earth nanoparticles (RE-NPs), particularly NaYF4:Yb3+,Er3+, have emerged as a promising class of photoluminescent probes for bioimaging and sensing applications. These nanomaterials are characterized by their ability to absorb low-energy photons and emit higher-energy photons through an upconversion luminescence process. This process can be triggered by continuous-wave (CW) light excitation, providing a unique optical feature that is not exhibited by native biomolecules. However, the application of upconversion nanoparticles (UCNPs) in bioimaging requires systematic optimization to maximize the signal and ensure biological compatibility. In this work, we synthesized hexagonal-phase UCNPs (average diameter: 29 ± 3 nm) coated with polyacrylic acid (PAA) and established the optimal conditions for imaging human erythrocytes. The best results were obtained after a 4-h incubation in 100 mM HEPES buffer, using a nanoparticle concentration of 0.01 mg/mL and a laser current intensity of 250–300 mA. Under these conditions, the UCNPs exhibited minimal cytotoxicity and were found to predominantly localize at the erythrocyte membrane periphery, indicating surface adsorption rather than internalization. Additionally, a machine learning model (Random Forest) was implemented that classified the photoluminescent signal with 80% accuracy and 83% precision, with the signal intensity identified as the most relevant feature. This study establishes a quantitative and validated protocol that balances signal strength with cell integrity, enabling robust and automated image analysis.

  • Open Access

    Experimental data validating the optimization of a wireless power transfer prototype employing a novel phase shift measurement system and frequency control

    by Andrés Martínez, Christian González, Adrián Jaramillo, Dorindo Cárdenas, Alejandro Von Chong


  • Open Access

    Low-cost, microcontroller-based phase shift measurement system for a wireless power transfer prototype

    by Andrés Martínez, Christian González, Adrián Jaramillo, Dorindo Cárdenas, Alejandro Von Chong