Zachary T. Grace
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zachary T. Grace has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Martinus Megalla
Department of Orthopaedic Surgery, Hackensack Meridian School of Medicine, Nutley, NJ, USA
5 shared publications - Alexander K. Hahn
Department of Orthopaedic Surgery, University of Connecticut Health Center, Farmington, CT, USA
2 shared publications - Francis G. Alberta
Department of Orthopaedic Surgery, Hackensack University Medical Center, Hackensack, NJ, USA
2 shared publications - Nareena Imam
Department of Orthopedic Surgery, Rutgers Robert Wood Johnson Medical School, New Brunswick, New Jersey
2 shared publications A.R. Nagarkatti
College of Holy Cross, WorcesterMassachusetts
1 shared publicationAlexander K. Hahn
1 shared publication
Latest Publications
- Open Access
- 11 September 2026
- Published by Elsevier in JSES International
- Vol. 10 (6)
Biomechanical evaluation of the gravity varus test in a cadaveric model of posterolateral rotatory instability of the elbow
- 11 September 2026
- Published by Elsevier in JSES International
- Vol. 10 (6)
Open AccessBiomechanical evaluation of the gravity varus test in a cadaveric model of posterolateral rotatory instability of the elbow
- 20 February 2026
- Published by SAGE Publications in HAND
Comparing Fixation Stability of Rotationally Unstable Proximal Phalanx Fractures: A Biomechanical Study
Background: Proximal phalanx fractures are common upper extremity injuries; surgical fixation is often recommended for unstable patterns. Intramedullary screw (IMS) fixation has emerged as a minimally invasive technique with potential benefits of earlier motion and reduction of soft tissue disruption compared with traditional methods. However, its resistance to fracture displacement in rotationally unstable fracture patterns requires further investigation. This study compares the biomechanical stability of single IMS, dual crossing IMS, and 2 interfragmentary cortical screw constructs in short oblique proximal phalanx fractures. Methods: Eleven cadaveric hands were used in the study. Sixty-degree oblique extra-articular proximal phalanx fractures were created in middle, index, and ring fingers and then randomly assigned to 1 of 3 constructs: single 3.5-mm IMS, dual crossing 2.5-mm IMS, or two 1.5-mm cortical screws perpendicular to the fracture. The hands underwent a flexion-extension protocol of 2000 cycles at 0.25 Hz, simulating postoperative motion. The fractures’ angular rotation (degrees) and displacement in coronal and sagittal planes (millimeters) were subsequently measured. Statistical analysis was conducted using analysis of variance with P value <.05 defined as statistically significant. Results: There was no significant difference in average angular rotation, or sagittal and coronal displacement across the 3 constructs after simulated early postoperative range of motion. None of the specimen reached clinically significant displacement more than 2 mm. Conclusion: The biomechanical stability of single IMS, dual IMS, and interfragmentary screws does not differ when considering angular rotation or displacement during simulated early postoperative range of motion in short oblique proximal phalanx fractures.
- 20 February 2026
- Published by SAGE Publications in HAND
Comparing Fixation Stability of Rotationally Unstable Proximal Phalanx Fractures: A Biomechanical Study
Background: Proximal phalanx fractures are common upper extremity injuries; surgical fixation is often recommended for unstable patterns. Intramedullary screw (IMS) fixation has emerged as a minimally invasive technique with potential benefits of earlier motion and reduction of soft tissue disruption compared with traditional methods. However, its resistance to fracture displacement in rotationally unstable fracture patterns requires further investigation. This study compares the biomechanical stability of single IMS, dual crossing IMS, and 2 interfragmentary cortical screw constructs in short oblique proximal phalanx fractures. Methods: Eleven cadaveric hands were used in the study. Sixty-degree oblique extra-articular proximal phalanx fractures were created in middle, index, and ring fingers and then randomly assigned to 1 of 3 constructs: single 3.5-mm IMS, dual crossing 2.5-mm IMS, or two 1.5-mm cortical screws perpendicular to the fracture. The hands underwent a flexion-extension protocol of 2000 cycles at 0.25 Hz, simulating postoperative motion. The fractures’ angular rotation (degrees) and displacement in coronal and sagittal planes (millimeters) were subsequently measured. Statistical analysis was conducted using analysis of variance with P value <.05 defined as statistically significant. Results: There was no significant difference in average angular rotation, or sagittal and coronal displacement across the 3 constructs after simulated early postoperative range of motion. None of the specimen reached clinically significant displacement more than 2 mm. Conclusion: The biomechanical stability of single IMS, dual IMS, and interfragmentary screws does not differ when considering angular rotation or displacement during simulated early postoperative range of motion in short oblique proximal phalanx fractures.
- Open Access
- 3 July 2025
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 5 (4) , 693-698
Representation of female authorship among American Shoulder and Elbow Surgeons meetings from 2008 to 2022
- 3 July 2025
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 5 (4) , 693-698
Open AccessRepresentation of female authorship among American Shoulder and Elbow Surgeons meetings from 2008 to 2022
- 5 January 2025
- Published by Elsevier in Seminars in Arthroplasty: JSES
- Vol. 35 (2) , 158-165
Use of ChatGPT vs. Google web search in anatomic total shoulder arthroplasty and reverse total shoulder arthroplasty: from a patient’s perspective
- 5 January 2025
- Published by Elsevier in Seminars in Arthroplasty: JSES
- Vol. 35 (2) , 158-165
Use of ChatGPT vs. Google web search in anatomic total shoulder arthroplasty and reverse total shoulder arthroplasty: from a patient’s perspective
- 1 April 2024
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 14 (2)
Feasibility of Multilevel Anterior Lumbar Interbody Fusion in a Patient With an Intrapelvic Kidney
Case: We present a 64-year-old woman with loss of lumbar lordosis with a preoperative computed tomography scan demonstrating the presence of an intrapelvic kidney with aberrant vasculature. A 2-level anterior lumbar interbody fusion with a 2-level oblique interbody fusion was planned. An anterior approach was successfully used to access the anterior spine without damaging the pelvic kidney. Conclusion: Anatomic variations, both congenital and acquired, can pose significant challenges to surgeons during their dissection. We present a case where multilevel anterior interbody cage placement can be safely performed, even in a patient whose anatomy is complicated by an intrapelvic kidney.
- 1 April 2024
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 14 (2)
Feasibility of Multilevel Anterior Lumbar Interbody Fusion in a Patient With an Intrapelvic Kidney
Case: We present a 64-year-old woman with loss of lumbar lordosis with a preoperative computed tomography scan demonstrating the presence of an intrapelvic kidney with aberrant vasculature. A 2-level anterior lumbar interbody fusion with a 2-level oblique interbody fusion was planned. An anterior approach was successfully used to access the anterior spine without damaging the pelvic kidney. Conclusion: Anatomic variations, both congenital and acquired, can pose significant challenges to surgeons during their dissection. We present a case where multilevel anterior interbody cage placement can be safely performed, even in a patient whose anatomy is complicated by an intrapelvic kidney.
- 14 October 2022
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 32 (3) , 539-545
Medical malpractice litigation after total shoulder arthroplasty: a comprehensive analysis based on the Westlaw legal database
- 14 October 2022
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 32 (3) , 539-545
Medical malpractice litigation after total shoulder arthroplasty: a comprehensive analysis based on the Westlaw legal database
- 1 January 2022
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 12 (4)
Pudendal Neurapraxia After Proximal Hamstring Repair
Case: The pudendal nerve lies near the origin of the hamstring muscles, placing it at increased risk of injury during proximal hamstring tendon repair. In this study, we report on a 56-year old man who experienced intermittent unilateral testicular pain after a proximal hamstring tendon repair presumably due to pudendal nerve neurapraxia. At the 1-year follow-up, he continued to experience discomfort in the pudendal nerve distribution but reported significant improvement in symptoms and complete resolution of hamstring pain. Conclusion: Although the risk of pudendal nerve injury during proximal hamstring tendon repair is rare, surgeons should be aware of this potential complication.
- 1 January 2022
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 12 (4)
Pudendal Neurapraxia After Proximal Hamstring Repair
Case: The pudendal nerve lies near the origin of the hamstring muscles, placing it at increased risk of injury during proximal hamstring tendon repair. In this study, we report on a 56-year old man who experienced intermittent unilateral testicular pain after a proximal hamstring tendon repair presumably due to pudendal nerve neurapraxia. At the 1-year follow-up, he continued to experience discomfort in the pudendal nerve distribution but reported significant improvement in symptoms and complete resolution of hamstring pain. Conclusion: Although the risk of pudendal nerve injury during proximal hamstring tendon repair is rare, surgeons should be aware of this potential complication.