Raimund Strauss
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Raimund Strauss has a total of 220 co-authors. Here are the top co-authors by number of shared publications:
C. Schwertner
MBI - Marietta-Blau-Institut für Teilchenphysik der Österreichischen Akademie der Wissenschaften
12 shared publicationsD. Hauff
Max-Planck-Institut für Physik
12 shared publications- Holger Kluck
Institut für Hochenergiephysik der Österreichischen Akademie der Wissenschaften 1050 Wien Austria
12 shared publications - Margarita Kaznacheeva
Technische Universität München
12 shared publications S. Fichtinger
MBI - Marietta-Blau-Institut für Teilchenphysik der Österreichischen Akademie der Wissenschaften
12 shared publicationsW. Potzel
Technische Universität München
12 shared publications
Latest Publications
- Open Access
- 17 November 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (11)
ImpCresst: a versatile simulation tool focusing on solid-state detectors at keV energies
We present Imp Cresst , a Geant4 -based Monte Carlo tool to simulate backgrounds from natural and cosmogenic radionuclides, and calibration signals in solid-state detectors and their response to it. It is tuned for a fast-evolving and heterogeneous detector environment with a focus on physics at the keV range. This tool was originally developed and validated by the CRESST collaboration; however, its flexibility and configurability make it suitable for other experiments with similar requirements. Key features of Imp Cresst include the dynamic geometry implementation directly from CAD files, ROOT-based data persistency of the whole event topology and automatic metadata annotation for data provenance, and interfaces to various particle generators, particularly for radiogenic and cosmogenic radionuclides. It includes also a newly developed particle generator for radioactive bulk and surface contaminations which is completely independent of any user defined confinement volumes. The auxiliary tool CresstDS applies detector-specific energy and time resolution based on a user-provided data set of empirical parameterization. We discuss also how to manage an Imp Cresst based workflow in an HPC environment based on Apptainer and nextflow.
- 17 November 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (11)
Open AccessImpCresst: a versatile simulation tool focusing on solid-state detectors at keV energies
We present Imp Cresst , a Geant4 -based Monte Carlo tool to simulate backgrounds from natural and cosmogenic radionuclides, and calibration signals in solid-state detectors and their response to it. It is tuned for a fast-evolving and heterogeneous detector environment with a focus on physics at the keV range. This tool was originally developed and validated by the CRESST collaboration; however, its flexibility and configurability make it suitable for other experiments with similar requirements. Key features of Imp Cresst include the dynamic geometry implementation directly from CAD files, ROOT-based data persistency of the whole event topology and automatic metadata annotation for data provenance, and interfaces to various particle generators, particularly for radiogenic and cosmogenic radionuclides. It includes also a newly developed particle generator for radioactive bulk and surface contaminations which is completely independent of any user defined confinement volumes. The auxiliary tool CresstDS applies detector-specific energy and time resolution based on a user-provided data set of empirical parameterization. We discuss also how to manage an Imp Cresst based workflow in an HPC environment based on Apptainer and nextflow.
- Open Access
- 1 October 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (10) , P10026
Sensitivity enhancement techniques for cryogenic calorimeters in the NUCLEUS experiment
Phonon-mediated cryogenic calorimeters find application in rare event searches due to their intrinsically low energy threshold. Achieving optimal sensitivity for these kinds of detectors is crucial for signal identification, leading to various optimization techniques. In this work, we present two complementary methods to increase the sensitivity of cryogenic detectors read out by transition-edge sensors, developed and tested in the context of the NUCLEUS experiment. The first procedure maps the signal-to-noise ratio of the device across a wide range of operating points, to identify the configuration with maximal sensitivity to be used during data taking. The second method exploits the double readout of the detector, combining the information from different channels with a two-dimensional optimum filter analysis that effectively lowers the energy threshold. By combining both techniques at the same time, we obtain a baseline resolution of 2.94 ± 0.05 stat ±0.74 syst eV using a CaWO 4 based detector, achieving a promising result ahead of the first run of NUCLEUS at the experimental site.
- 1 October 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (10) , P10026
Open AccessSensitivity enhancement techniques for cryogenic calorimeters in the NUCLEUS experiment
Phonon-mediated cryogenic calorimeters find application in rare event searches due to their intrinsically low energy threshold. Achieving optimal sensitivity for these kinds of detectors is crucial for signal identification, leading to various optimization techniques. In this work, we present two complementary methods to increase the sensitivity of cryogenic detectors read out by transition-edge sensors, developed and tested in the context of the NUCLEUS experiment. The first procedure maps the signal-to-noise ratio of the device across a wide range of operating points, to identify the configuration with maximal sensitivity to be used during data taking. The second method exploits the double readout of the detector, combining the information from different channels with a two-dimensional optimum filter analysis that effectively lowers the energy threshold. By combining both techniques at the same time, we obtain a baseline resolution of 2.94 ± 0.05 stat ±0.74 syst eV using a CaWO 4 based detector, achieving a promising result ahead of the first run of NUCLEUS at the experimental site.
- Open Access
- 17 August 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (8) , 973
Publisher Correction: Characterization of the low energy excess using a NUCLEUS $\text {Al}_{2}\text {O}_{3}$ detector- 17 August 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (8) , 973
Open AccessPublisher Correction: Characterization of the low energy excess using a NUCLEUS $\text {Al}_{2}\text {O}_{3}$ detector - Open Access
- 18 July 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (7) , 831
Characterization of the low energy excess using a NUCLEUS Al$_2$O$_3$ detectorThe NUCLEUS experiment aims to detect coherent elastic neutrino–nucleus scattering of reactor antineutrinos using low-threshold, gram-scale cryogenic calorimeters. Similar to other low-threshold experiments, NUCLEUS observes a sharp rise in the event rate below a few hundred eV, referred to as the low energy excess (LEE), whose origin remains yet unidentified. Building on results from the NUCLEUS testing and commissioning at the Technical University of Munich and from previous characterization campaigns, we present a comprehensive study of the background rate measured with a sapphire detector equipped with two transition-edge sensors under various experimental conditions. We find no evidence for a dependence of the LEE rate on the particle background level, whereas the results indicate that slower cooling-down procedures lead to lower initial LEE rates. The behavior of the LEE rate during the same cooldown is comparable across the measurements and is best described by a power law with a common exponent across datasets of $$(-0.59\pm 0.06)$$ , when time is expressed from the moment the detector reaches the 4 K temperature. These findings provide valuable guidance for future LEE mitigation strategies in the NUCLEUS experiment.- 18 July 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (7) , 831
Open AccessCharacterization of the low energy excess using a NUCLEUS Al$_2$O$_3$ detectorThe NUCLEUS experiment aims to detect coherent elastic neutrino–nucleus scattering of reactor antineutrinos using low-threshold, gram-scale cryogenic calorimeters. Similar to other low-threshold experiments, NUCLEUS observes a sharp rise in the event rate below a few hundred eV, referred to as the low energy excess (LEE), whose origin remains yet unidentified. Building on results from the NUCLEUS testing and commissioning at the Technical University of Munich and from previous characterization campaigns, we present a comprehensive study of the background rate measured with a sapphire detector equipped with two transition-edge sensors under various experimental conditions. We find no evidence for a dependence of the LEE rate on the particle background level, whereas the results indicate that slower cooling-down procedures lead to lower initial LEE rates. The behavior of the LEE rate during the same cooldown is comparable across the measurements and is best described by a power law with a common exponent across datasets of $$(-0.59\pm 0.06)$$ , when time is expressed from the moment the detector reaches the 4 K temperature. These findings provide valuable guidance for future LEE mitigation strategies in the NUCLEUS experiment. - Open Access
- 16 January 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (1) , 29
Particle background characterization and prediction for the NUCLEUS reactor CE$\nu $NS experimentNUCLEUS is a cryogenic detection experiment which aims to measure Coherent Elastic Neutrino–Nucleus Scattering (CE $$\nu $$ NS) and to search for new physics at the Chooz nuclear power plant in France. This article reports on the prediction of particle-induced backgrounds, especially focusing on the sub-keV energy range, which is a poorly known region where most of the CE $$\nu $$ NS signal from reactor antineutrinos is expected. Together with measurements of the environmental background radiations at the experimental site, extensive Monte Carlo simulations based on the Geant4 package were run both to optimize the experimental setup for background reduction and to estimate the residual rates arising from different contributions such as cosmic ray-induced radiations, environmental gammas and material radioactivity. The NUCLEUS experimental setup is predicted to achieve a total rejection power of more than two orders of magnitude, leaving a residual background component which is strongly dominated by cosmic ray-induced neutrons. In the CE $$\nu $$ NS signal region of interest between 10 and 100 eV, a total particle background rate of $$\sim $$ 250 d −1 kg −1 keV −1 is expected in the CaWO 4 target detectors. This corresponds to a signal-to-background ratio $$\gtrsim $$ 1, and therefore meets the required specifications in terms of particle background rejection for the detection of reactor antineutrinos through CE $$\nu $$ NS.- 16 January 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (1) , 29
Open AccessParticle background characterization and prediction for the NUCLEUS reactor CE$\nu $NS experimentNUCLEUS is a cryogenic detection experiment which aims to measure Coherent Elastic Neutrino–Nucleus Scattering (CE $$\nu $$ NS) and to search for new physics at the Chooz nuclear power plant in France. This article reports on the prediction of particle-induced backgrounds, especially focusing on the sub-keV energy range, which is a poorly known region where most of the CE $$\nu $$ NS signal from reactor antineutrinos is expected. Together with measurements of the environmental background radiations at the experimental site, extensive Monte Carlo simulations based on the Geant4 package were run both to optimize the experimental setup for background reduction and to estimate the residual rates arising from different contributions such as cosmic ray-induced radiations, environmental gammas and material radioactivity. The NUCLEUS experimental setup is predicted to achieve a total rejection power of more than two orders of magnitude, leaving a residual background component which is strongly dominated by cosmic ray-induced neutrons. In the CE $$\nu $$ NS signal region of interest between 10 and 100 eV, a total particle background rate of $$\sim $$ 250 d −1 kg −1 keV −1 is expected in the CaWO 4 target detectors. This corresponds to a signal-to-background ratio $$\gtrsim $$ 1, and therefore meets the required specifications in terms of particle background rejection for the detection of reactor antineutrinos through CE $$\nu $$ NS. - Open Access
- 26 November 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 112 (10)
Observation of a low energy nuclear recoil peak in the neutron calibration data of an Al 2 O 3 crystal in CRESST-III
The current generation of cryogenic solid state detectors used in direct dark matter and CE ν NS searches typically reach energy thresholds of O ( 10 ) eV for nuclear recoils. For a reliable calibration in this energy regime a method has been proposed, providing monoenergetic nuclear recoils at low energies ∼ 100 eV – 1 keV . In this work we report on the observation of a peak at ( 1113.6 − 6.5 + 6.5 ) eV in the data of an Al 2 O 3 crystal in CRESST-III, which was irradiated with neutrons from an AmBe calibration source. We attribute this monoenergetic peak to the radiative capture of thermal neutrons on Al 27 and the subsequent deexcitation via single γ emission. We compare the measured results with the outcome of Geant4 simulations and investigate the possibility to make use of this effect for the energy calibration of Al 2 O 3 detectors at low energies. We further investigate the possibility of a shift in the expected energy scale of this effect caused by the creation of defects in the target crystal.
- 26 November 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 112 (10)
Open AccessObservation of a low energy nuclear recoil peak in the neutron calibration data of an Al 2 O 3 crystal in CRESST-III
The current generation of cryogenic solid state detectors used in direct dark matter and CE ν NS searches typically reach energy thresholds of O ( 10 ) eV for nuclear recoils. For a reliable calibration in this energy regime a method has been proposed, providing monoenergetic nuclear recoils at low energies ∼ 100 eV – 1 keV . In this work we report on the observation of a peak at ( 1113.6 − 6.5 + 6.5 ) eV in the data of an Al 2 O 3 crystal in CRESST-III, which was irradiated with neutrons from an AmBe calibration source. We attribute this monoenergetic peak to the radiative capture of thermal neutrons on Al 27 and the subsequent deexcitation via single γ emission. We compare the measured results with the outcome of Geant4 simulations and investigate the possibility to make use of this effect for the energy calibration of Al 2 O 3 detectors at low energies. We further investigate the possibility of a shift in the expected energy scale of this effect caused by the creation of defects in the target crystal.
- Open Access
- 28 October 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 112 (7)
Commissioning of the NUCLEUS Experiment at the Technical University of Munich
The NUCLEUS experiment aims to detect coherent elastic neutrino-nucleus scattering of reactor antineutrinos on CaWO 4 targets in the fully coherent regime, using gram-scale cryogenic calorimeters. The experimental apparatus will be installed at the Chooz nuclear power plant in France, in the vicinity of two 4.25 GW th reactor cores. This work presents results from the commissioning of an essential version of the experiment at the shallow Underground Laboratory of the Technical University of Munich. For the first time, two cryogenic target detectors were tested alongside active and passive shielding systems. Over a period of two months, all detector subsystems were operated with stable performance. Background measurements were conducted, providing important benchmarks for the modeling of background sources at the reactor site. Finally, we present ongoing efforts to upgrade the detector systems in preparation for a technical run at Chooz in 2026, and highlight the remaining challenges to achieving neutrino detection.
- 28 October 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 112 (7)
Open AccessCommissioning of the NUCLEUS Experiment at the Technical University of Munich
The NUCLEUS experiment aims to detect coherent elastic neutrino-nucleus scattering of reactor antineutrinos on CaWO 4 targets in the fully coherent regime, using gram-scale cryogenic calorimeters. The experimental apparatus will be installed at the Chooz nuclear power plant in France, in the vicinity of two 4.25 GW th reactor cores. This work presents results from the commissioning of an essential version of the experiment at the shallow Underground Laboratory of the Technical University of Munich. For the first time, two cryogenic target detectors were tested alongside active and passive shielding systems. Over a period of two months, all detector subsystems were operated with stable performance. Background measurements were conducted, providing important benchmarks for the modeling of background sources at the reactor site. Finally, we present ongoing efforts to upgrade the detector systems in preparation for a technical run at Chooz in 2026, and highlight the remaining challenges to achieving neutrino detection.
- Open Access
- 22 October 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (10) , 1-24
The CRAB facility at the TU Wien TRIGA reactor: status and related physics program
The Crab (Calibrated nuclear Recoils for Accurate Bolometry) project aims to precisely characterize the response of cryogenic detectors to sub-keV nuclear recoils of direct interest for coherent neutrino-nucleus scattering and dark matter search experiments. The Crab method relies on the radiative capture of thermal neutrons in the target detector, resulting in a nuclear recoil with a well-defined energy. We present a new experimental setup installed at the TRIGA Mark-II reactor at Atominstitut (Vienna), providing a low intensity beam of thermal neutrons sent to the target cryogenic detector mounted inside a wet dilution refrigerator Kelvinox 100. After the presentation of all components of the setup we report the analysis of first commissioning data with CaWO $$_{4}$$ detectors of the Nucleus experiment. They show stable operation of the cryostat and detectors on a week-scale. Due to an energy resolution currently limited to 20 eV we use neutron beam induced events at high energy, in the 10 to 100 keV range, to demonstrate the excellent agreement between the data and simulation and the accurate understanding of external background. Thanks to these data we also propose an updated decay scheme of the low-lying excited states of $$^{187}$$ W. Finally, we present the first evidence of neutron-capture induced coincidences between BaF $$_2$$ $$\gamma $$ -detectors installed around the dewar and the inner cryogenic detector. These promising results pave the way for an extensive physics program with various detector materials, like CaWO $$_{4}$$ , Al $$_{2}$$ O $$_{3}$$ , Ge and Si.- 22 October 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (10) , 1-24
Open AccessThe CRAB facility at the TU Wien TRIGA reactor: status and related physics program
The Crab (Calibrated nuclear Recoils for Accurate Bolometry) project aims to precisely characterize the response of cryogenic detectors to sub-keV nuclear recoils of direct interest for coherent neutrino-nucleus scattering and dark matter search experiments. The Crab method relies on the radiative capture of thermal neutrons in the target detector, resulting in a nuclear recoil with a well-defined energy. We present a new experimental setup installed at the TRIGA Mark-II reactor at Atominstitut (Vienna), providing a low intensity beam of thermal neutrons sent to the target cryogenic detector mounted inside a wet dilution refrigerator Kelvinox 100. After the presentation of all components of the setup we report the analysis of first commissioning data with CaWO $$_{4}$$ detectors of the Nucleus experiment. They show stable operation of the cryostat and detectors on a week-scale. Due to an energy resolution currently limited to 20 eV we use neutron beam induced events at high energy, in the 10 to 100 keV range, to demonstrate the excellent agreement between the data and simulation and the accurate understanding of external background. Thanks to these data we also propose an updated decay scheme of the low-lying excited states of $$^{187}$$ W. Finally, we present the first evidence of neutron-capture induced coincidences between BaF $$_2$$ $$\gamma $$ -detectors installed around the dewar and the inner cryogenic detector. These promising results pave the way for an extensive physics program with various detector materials, like CaWO $$_{4}$$ , Al $$_{2}$$ O $$_{3}$$ , Ge and Si. - Open Access
- 6 September 2025
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 221 (1-6) , 265-288
Sub-keV Electron Recoil Calibration for Macroscopic Cryogenic Calorimeters Using a Novel X-ray Fluorescence Source
Percent-level calibration of cryogenic macro-calorimeters with energy thresholds below 100 eV is crucial for light Dark Matter (DM) searches and reactor neutrino studies based on coherent elastic neutrino-nucleus scattering (CEvNS). This paper presents a novel calibration source based on X-ray fluorescence (XRF) of light elements. It uses a $$^{55}$$ Fe source to irradiate a two-staged target arrangement, emitting characteristic emission lines from 677 eV to 6.5 keV. We demonstrate the potential of this new XRF source to calibrate a 0.75 g CaWO $$_4$$ crystal of the NUCLEUS and CRAB experiments. Additionally, we introduce CryoLab, an advanced analysis tool for cryogenic detector data, featuring robust methods for data processing, calibration, and high-level analysis, implemented in MATLAB and HDF5. We also present a phenomenological model for energy resolution, which incorporates statistical contributions, systematic effects, and baseline noise, enabling a novel approach to evaluating athermal phonon collection efficiency in macro-calorimeters based on transition edge sensors (TES).- 6 September 2025
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 221 (1-6) , 265-288
Open AccessSub-keV Electron Recoil Calibration for Macroscopic Cryogenic Calorimeters Using a Novel X-ray Fluorescence Source
Percent-level calibration of cryogenic macro-calorimeters with energy thresholds below 100 eV is crucial for light Dark Matter (DM) searches and reactor neutrino studies based on coherent elastic neutrino-nucleus scattering (CEvNS). This paper presents a novel calibration source based on X-ray fluorescence (XRF) of light elements. It uses a $$^{55}$$ Fe source to irradiate a two-staged target arrangement, emitting characteristic emission lines from 677 eV to 6.5 keV. We demonstrate the potential of this new XRF source to calibrate a 0.75 g CaWO $$_4$$ crystal of the NUCLEUS and CRAB experiments. Additionally, we introduce CryoLab, an advanced analysis tool for cryogenic detector data, featuring robust methods for data processing, calibration, and high-level analysis, implemented in MATLAB and HDF5. We also present a phenomenological model for energy resolution, which incorporates statistical contributions, systematic effects, and baseline noise, enabling a novel approach to evaluating athermal phonon collection efficiency in macro-calorimeters based on transition edge sensors (TES). - Open Access
- 1 May 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (05) , P05022
Decoupling pulse tube vibrations from a dry dilution refrigerator at milli-Kelvin temperatures
With the rising adoption of dry dilution refrigerators across scientific and industrial domains, there has been a pressing demand for highly efficient vibration decoupling systems capable of operation at cryogenic temperatures in order to achieve the low vibration levels required for operation of sensitive equipment like cryogenic detectors or quantum devices. As part of the NUCLEUS experiment, a cryogenic spring pendulum has been engineered to effectively isolate pulse tube vibrations by establishing an autonomous frame of reference for the experimental volume, while sustaining temperatures below 10 mK. Attaining attenuation of up to two orders of magnitude within the region of interest of the NUCLEUS cryogenic detectors, we achieved displacement RMS values in the order of 1 nm in the axial direction and 100 pm radially, thereby reducing vibrations below typical environmental levels. Our successful detector operation across multiple cooldown cycles demonstrated negligible sensitivity to pulse tube induced vibrations, culminating in the achievement of an ultra-low (6.22 ± 0.07) eV baseline resolution on a gram-scale CaWO4 cryogenic calorimeter during continuous pulse tube operation over the course of several weeks.
- 1 May 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (05) , P05022
Open AccessDecoupling pulse tube vibrations from a dry dilution refrigerator at milli-Kelvin temperatures
With the rising adoption of dry dilution refrigerators across scientific and industrial domains, there has been a pressing demand for highly efficient vibration decoupling systems capable of operation at cryogenic temperatures in order to achieve the low vibration levels required for operation of sensitive equipment like cryogenic detectors or quantum devices. As part of the NUCLEUS experiment, a cryogenic spring pendulum has been engineered to effectively isolate pulse tube vibrations by establishing an autonomous frame of reference for the experimental volume, while sustaining temperatures below 10 mK. Attaining attenuation of up to two orders of magnitude within the region of interest of the NUCLEUS cryogenic detectors, we achieved displacement RMS values in the order of 1 nm in the axial direction and 100 pm radially, thereby reducing vibrations below typical environmental levels. Our successful detector operation across multiple cooldown cycles demonstrated negligible sensitivity to pulse tube induced vibrations, culminating in the achievement of an ultra-low (6.22 ± 0.07) eV baseline resolution on a gram-scale CaWO4 cryogenic calorimeter during continuous pulse tube operation over the course of several weeks.