Hemeth Dhaliwal
Research Subjects
Hemeth Dhaliwal has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Bernard M. Lawless
Dept. of Mechanical Engineering, University of Birmingham, Birmingham B15 2TT, UK
1 shared publication- Daniel M. Espino
Department of Mechanical Engineering, University of Birmingham, Birmingham B15 2TT, UK
1 shared publication David W.L. Hukins
Dept. of Mechanical Engineering, University of Birmingham, Birmingham B15 2TT, UK
1 shared publicationDuncan K. Temple
Dept. of Mechanical Engineering, University of Birmingham, Birmingham B15 2TT, UK
1 shared publication- Haider Butt
Department of Mechanical and Nuclear Engineering, Khalifa University of Science and Technology, Abu Dhabi, UAE
1 shared publication Hamid Sadeghi
Dept. of Mechanical Engineering, University of Birmingham, Birmingham B15 2TT, UK
1 shared publication
Latest Publications
- Open Access
- 21 October 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (20) , 10661
Contact Lens-Based Microchannel Rings for Detecting Ocular Hypertension
Glaucoma is a major cause of irreversible blindness worldwide. The most acknowledged biomarker to diagnose and monitor glaucoma progression is intraocular pressure (IOP). Gold standard techniques for IOP monitoring are invasive, uncomfortable, and require visiting a clinic. In addition, most methods only provide a single snapshot on widely varying parameters. On the other hand, contact lenses have attracted particular interest to be used as continuous monitoring platforms to incorporate sensors, drugs, and more. Here, commercial contact lenses were laser-processed to be capable of detecting IOP variations in the physiological range. Three ring-couples with interspaces of 1.0, 1.5, and 2.0 mm were engraved on three soft contact lenses separately by using a carbon dioxide laser. The IOP/pressure variations induced repeatable changes in the ring-couple interspace which acted as a smartphone-readable pressure sensor. The processed contact lenses may be a potential candidate toward IOP monitoring at point-of-care settings.
- 21 October 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (20) , 10661
Open AccessContact Lens-Based Microchannel Rings for Detecting Ocular Hypertension
Glaucoma is a major cause of irreversible blindness worldwide. The most acknowledged biomarker to diagnose and monitor glaucoma progression is intraocular pressure (IOP). Gold standard techniques for IOP monitoring are invasive, uncomfortable, and require visiting a clinic. In addition, most methods only provide a single snapshot on widely varying parameters. On the other hand, contact lenses have attracted particular interest to be used as continuous monitoring platforms to incorporate sensors, drugs, and more. Here, commercial contact lenses were laser-processed to be capable of detecting IOP variations in the physiological range. Three ring-couples with interspaces of 1.0, 1.5, and 2.0 mm were engraved on three soft contact lenses separately by using a carbon dioxide laser. The IOP/pressure variations induced repeatable changes in the ring-couple interspace which acted as a smartphone-readable pressure sensor. The processed contact lenses may be a potential candidate toward IOP monitoring at point-of-care settings.
- Open Access
- 1 November 2017
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 75, 293-301
Viscoelasticity of articular cartilage: Analysing the effect of induced stress and the restraint of bone in a dynamic environment
- 1 November 2017
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 75, 293-301
Open AccessViscoelasticity of articular cartilage: Analysing the effect of induced stress and the restraint of bone in a dynamic environment