Hyeoktae Son
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hyeoktae Son has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Byeongkwan Jin
Department of Electronics Engineering, Chungnam National University, Daejeon 34134, Republic of Korea
4 shared publications - Gyuri Choi
Department of Electronics Engineering, Chungnam National University, Daejeon 34134, Republic of Korea
4 shared publications - Hyoungho Ko
Chungnam National University
4 shared publications - Kyeongsik Nam
Department of Electronics Engineering, Chungnam National University, Daejeon 34134, Republic of Korea
4 shared publications - Mookyoung Yoo
Department of Electronics Engineering, Chungnam National University, Daejeon 34134, Republic of Korea
4 shared publications - Sanggyun Kang
Department of Electronics Engineering, Chungnam National University, Daejeon 34134, Republic of Korea
4 shared publications
Latest Publications
- Open Access
- 15 December 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (24) , 12897
Low-Noise, Low-Power Readout IC for Two-Electrode ECG Recording Using Common-Mode Charge Pump for Robust 20-VPP Common-Mode Interference
A low-noise and -power readout integrated circuit (IC) for two-electrode electrocardiogram (ECG) recording is developed in this study using a common-mode charge pump (CMCP) for a robust 20-VPP common-mode interference (CMI). Two-electrode ECG recording offers more comfort than three-electrode ECG recording. Contrasting to the three-electrode ECG recording, the two-electrode ECG recording is affected by CMI during measurements; the intervention of a large CMI will distort the ECG signal measurement. To achieve robustness for the CMI, the proposed ECG readout IC adopts CMCP—it uses switched capacitors that store and subtract CMI by control logic. In this paper, a window comparator structure is applied to CMCP to obtain a signal with less distortion. The window voltage ranges were set between the input common-mode ranges in which IA can operate. Therefore, a signal with less distortion was obtained by stopping the operation of CMCP between the window voltage ranges. It also reduced additional current consumption. To achieve this, the proposed circuit is implemented using a chopper stabilization technique. The chopper implemented in the amplifier can reduce low-frequency noise components, such as 1/f noise, and it comprises a CMCP, current feedback instrumentation amplifier, QRS peak detector, relaxation oscillator, voltage reference, timing generator, and serial peripheral interface on a single chip. The proposed circuit was designed using a standard 0.18 μm CMOS process with an active area of 0.54 mm2. The proposed CMCP achieves a CMI robustness of 20 VPP at 60 Hz. The measured input-referred noise level was 119 nV/√Hz at 1 Hz, and the power consumption was 23.83 μW with a 1.8 V power supply.
- 15 December 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (24) , 12897
Open AccessLow-Noise, Low-Power Readout IC for Two-Electrode ECG Recording Using Common-Mode Charge Pump for Robust 20-VPP Common-Mode Interference
A low-noise and -power readout integrated circuit (IC) for two-electrode electrocardiogram (ECG) recording is developed in this study using a common-mode charge pump (CMCP) for a robust 20-VPP common-mode interference (CMI). Two-electrode ECG recording offers more comfort than three-electrode ECG recording. Contrasting to the three-electrode ECG recording, the two-electrode ECG recording is affected by CMI during measurements; the intervention of a large CMI will distort the ECG signal measurement. To achieve robustness for the CMI, the proposed ECG readout IC adopts CMCP—it uses switched capacitors that store and subtract CMI by control logic. In this paper, a window comparator structure is applied to CMCP to obtain a signal with less distortion. The window voltage ranges were set between the input common-mode ranges in which IA can operate. Therefore, a signal with less distortion was obtained by stopping the operation of CMCP between the window voltage ranges. It also reduced additional current consumption. To achieve this, the proposed circuit is implemented using a chopper stabilization technique. The chopper implemented in the amplifier can reduce low-frequency noise components, such as 1/f noise, and it comprises a CMCP, current feedback instrumentation amplifier, QRS peak detector, relaxation oscillator, voltage reference, timing generator, and serial peripheral interface on a single chip. The proposed circuit was designed using a standard 0.18 μm CMOS process with an active area of 0.54 mm2. The proposed CMCP achieves a CMI robustness of 20 VPP at 60 Hz. The measured input-referred noise level was 119 nV/√Hz at 1 Hz, and the power consumption was 23.83 μW with a 1.8 V power supply.
- Open Access
- 16 November 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (22) , 11651
A Single-Bit Incremental Second-Order Delta-Sigma Modulator with Coarse-Fine Input Buffer
This paper presents an incremental second-order delta-sigma modulator with a coarse-fine input buffer in 180-nm CMOS. The modulator’s architecture was implemented as a second-order cascade of integrators with a feedback structure. The switched-capacitor integrator was operated in discrete time, with high-gain amplifiers required to achieve improved performance during the integration phase. The amplifier comprised rail-to-rail input and gain-boosted cascode intermediate stages, thus achieving a high gain and wide input voltage range. The circuit adopts a coarse-fine buffer for higher performance. The coarse buffer is operated first to enable fast settling through a high slew rate, followed by the fine buffer to satisfy the low-noise and high-accuracy characteristics. The fine buffer has a smaller current consumption with higher power efficiency. The experiment results show that the proposed input buffer achieved a 13.14 effective number of bits and an 80.87 dB signal-to-noise and distortion ratio. The modulator operates a single bit and sampling clock at 125 kHz. The proposed delta-sigma modulator was operated at 1.8 V. The proposed circuit was designed using a standard 0.18-μm CMOS process with an active area of 1.06 mm2. The total current consumption with the coarse-fine buffer was 1.374 mA.
- 16 November 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (22) , 11651
Open AccessA Single-Bit Incremental Second-Order Delta-Sigma Modulator with Coarse-Fine Input Buffer
This paper presents an incremental second-order delta-sigma modulator with a coarse-fine input buffer in 180-nm CMOS. The modulator’s architecture was implemented as a second-order cascade of integrators with a feedback structure. The switched-capacitor integrator was operated in discrete time, with high-gain amplifiers required to achieve improved performance during the integration phase. The amplifier comprised rail-to-rail input and gain-boosted cascode intermediate stages, thus achieving a high gain and wide input voltage range. The circuit adopts a coarse-fine buffer for higher performance. The coarse buffer is operated first to enable fast settling through a high slew rate, followed by the fine buffer to satisfy the low-noise and high-accuracy characteristics. The fine buffer has a smaller current consumption with higher power efficiency. The experiment results show that the proposed input buffer achieved a 13.14 effective number of bits and an 80.87 dB signal-to-noise and distortion ratio. The modulator operates a single bit and sampling clock at 125 kHz. The proposed delta-sigma modulator was operated at 1.8 V. The proposed circuit was designed using a standard 0.18-μm CMOS process with an active area of 1.06 mm2. The total current consumption with the coarse-fine buffer was 1.374 mA.
- Open Access
- 8 November 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (22) , 11334
Low-Noise Potentiostat Readout Circuit with a Chopper Fully Differential Difference Amplifier for Glucose Monitoring
This paper presents a low-noise potentiostat readout circuit with a chopper fully differential difference amplifier (FDDA) for glucose monitoring. Glucose monitoring is necessary for the early diagnosis of diabetes complications and for health management. Ammeter electrochemical sensors are widely used for glucose detection, and in general, a three-electrode structure of a reference electrode (RE), a counter electrode (CE), and a working electrode (WE) is implemented with a potentiostat structure. A low-noise characteristic of the readout circuit is essential for highly accurate glucose monitoring. The chopping technique can reduce low-frequency noises such as 1/f noise and can achieve the required low-noise characteristic. The proposed potentiostat readout circuit is based on a low-noise chopper FDDA with a class-AB output stage. The implementation of the chopper FDDA scheme of the potentiostat readout circuit can decrease the number of amplifiers in the control part of the potentiostat, with reduced power consumption and a wide dynamic output range. The negative feedback loop of the inverting amplifier scheme with the FDDA maintains the voltage between the WE and RE constants. The negative feedback loop tracks the reference voltage of the RE with an input voltage of the WE. The proposed potentiostat readout circuit is designed in the standard 0.18 µm CMOS process, and the simulated current consumption is 48.54 μA with a 1.8 V power supply. The simulated input-referred noise level was 8.53 pArms.
- 8 November 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (22) , 11334
Open AccessLow-Noise Potentiostat Readout Circuit with a Chopper Fully Differential Difference Amplifier for Glucose Monitoring
This paper presents a low-noise potentiostat readout circuit with a chopper fully differential difference amplifier (FDDA) for glucose monitoring. Glucose monitoring is necessary for the early diagnosis of diabetes complications and for health management. Ammeter electrochemical sensors are widely used for glucose detection, and in general, a three-electrode structure of a reference electrode (RE), a counter electrode (CE), and a working electrode (WE) is implemented with a potentiostat structure. A low-noise characteristic of the readout circuit is essential for highly accurate glucose monitoring. The chopping technique can reduce low-frequency noises such as 1/f noise and can achieve the required low-noise characteristic. The proposed potentiostat readout circuit is based on a low-noise chopper FDDA with a class-AB output stage. The implementation of the chopper FDDA scheme of the potentiostat readout circuit can decrease the number of amplifiers in the control part of the potentiostat, with reduced power consumption and a wide dynamic output range. The negative feedback loop of the inverting amplifier scheme with the FDDA maintains the voltage between the WE and RE constants. The negative feedback loop tracks the reference voltage of the RE with an input voltage of the WE. The proposed potentiostat readout circuit is designed in the standard 0.18 µm CMOS process, and the simulated current consumption is 48.54 μA with a 1.8 V power supply. The simulated input-referred noise level was 8.53 pArms.
- Open Access
- 17 October 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (20) , 10471
Current-Feedback Instrumentation Amplifier Using Dual-Chopper Fill-In Technique
In this study, we describe a dual-chopper glitch-reduction current-feedback instrumentation amplifier (CFIA) with a ripple reduction loop. The amplifier employs the chopping technique to reduce low-frequency noise, such as 1/f noise. A glitch caused by chopping occurs at each chopper clock edge and results in intermodulation distortion (IMD). Owing to the input offset, the chopping technique also produces ripples. In this study, the glitch-induced IMD was reduced using a fill-in technique whereby only neat signals were alternately used as outputs by avoiding the glitch section with dual-chopping channel CFIA. To avoid using a high-order, low-frequency filter, a ripple reduction loop was implemented to reduce the ripple generated by chopping. The CFIA is based on a low-noise chopper fully differential difference amplifier with a cascode stage and a Monticelli-class AB output stage, which can drive a larger load and increase power efficiency. The proposed dual-chopper CFIA was fabricated using a 0.18 µm CMOS standard process, and its current consumption with a 1.8-V power supply is 29.5 μA. The proposed CFIA has a gain of 51 V/V, input referred noise of 53.3 nV/√Hz at 1 Hz, and a noise efficiency factor of 4.48.
- 17 October 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (20) , 10471
Open AccessCurrent-Feedback Instrumentation Amplifier Using Dual-Chopper Fill-In Technique
In this study, we describe a dual-chopper glitch-reduction current-feedback instrumentation amplifier (CFIA) with a ripple reduction loop. The amplifier employs the chopping technique to reduce low-frequency noise, such as 1/f noise. A glitch caused by chopping occurs at each chopper clock edge and results in intermodulation distortion (IMD). Owing to the input offset, the chopping technique also produces ripples. In this study, the glitch-induced IMD was reduced using a fill-in technique whereby only neat signals were alternately used as outputs by avoiding the glitch section with dual-chopping channel CFIA. To avoid using a high-order, low-frequency filter, a ripple reduction loop was implemented to reduce the ripple generated by chopping. The CFIA is based on a low-noise chopper fully differential difference amplifier with a cascode stage and a Monticelli-class AB output stage, which can drive a larger load and increase power efficiency. The proposed dual-chopper CFIA was fabricated using a 0.18 µm CMOS standard process, and its current consumption with a 1.8-V power supply is 29.5 μA. The proposed CFIA has a gain of 51 V/V, input referred noise of 53.3 nV/√Hz at 1 Hz, and a noise efficiency factor of 4.48.