Ailsa Willis
Research Subjects
Ailsa Willis has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Angus Ross Simpson
School of Architecture and Civil Engineering, The University of Adelaide, Adelaide, SA 5005, Australia
2 shared publications - Qi Zhao
Department of Infrastructure Engineering, The University of Melbourne, Parkville, VIC 3010, Australia
2 shared publications - Wenyan Wu
School of Engineering and the Built Environment, Birmingham City University, Birmingham B47XG, UK
2 shared publications
Latest Publications
- Open Access
Simpler Is Better—Calibration of Pipe Roughness in Water Distribution Systems
Hydraulic models of water distribution systems (WDSs) need to be calibrated, so they can be used to help to make informed decisions. Usually, hydraulic model calibration follows an iterative process of comparing the simulation results from the model with field observations and making adjustments to model parameters to make sure an acceptable level of agreement between predicted and measured values (e.g., water pressure) has been achieved. However, the manual process can be time-consuming, and the termination criterion relies on the modeler’s judgment. Therefore, various optimization-based calibration methods have been developed. In this study, three different optimization methods, i.e., Sequential Least Squares Programming (SLSQP), a Genetic Algorithm (GA) and Differential Evolution (DE), are compared for calibrating the pipe roughness of WDS models. Their performance is investigated over four different decision variable set formulations with different levels of discretization of the search space. Results obtained from a real-world case study demonstrate that compared to traditional engineering practice, optimization is effective for hydraulic model calibration. However, a finer search space discretization does not necessarily guarantee better results; and when multiple methods lead to similar performance, a simpler method is better. This study provides guidance on method and formulation selection for calibrating WDS models.
Open AccessSimpler Is Better—Calibration of Pipe Roughness in Water Distribution Systems
Hydraulic models of water distribution systems (WDSs) need to be calibrated, so they can be used to help to make informed decisions. Usually, hydraulic model calibration follows an iterative process of comparing the simulation results from the model with field observations and making adjustments to model parameters to make sure an acceptable level of agreement between predicted and measured values (e.g., water pressure) has been achieved. However, the manual process can be time-consuming, and the termination criterion relies on the modeler’s judgment. Therefore, various optimization-based calibration methods have been developed. In this study, three different optimization methods, i.e., Sequential Least Squares Programming (SLSQP), a Genetic Algorithm (GA) and Differential Evolution (DE), are compared for calibrating the pipe roughness of WDS models. Their performance is investigated over four different decision variable set formulations with different levels of discretization of the search space. Results obtained from a real-world case study demonstrate that compared to traditional engineering practice, optimization is effective for hydraulic model calibration. However, a finer search space discretization does not necessarily guarantee better results; and when multiple methods lead to similar performance, a simpler method is better. This study provides guidance on method and formulation selection for calibrating WDS models.
- Open Access
- 18 July 2022
- Published by Universitat Politecnica de Valencia
Water distribution system design with behind-the-meter solar energy under various discount rates
Water distribution systems (WDSs) are essential parts of urban and rural infrastructure systems. The energy consumption including associated costs and GHG emissions for distributing water has increased in recent years. As a result, behind-the-meter (BTM) energy systems such as solar panels and energy storage facilities have been installed by water utilities to reduce energy consumption from the centralised energy grid. There has been a lot of research on the optimisation of the design of WDSs, however, many of these works have not considered BTM energy options or have incorporated BTM energy options in an ad-hoc fashion. Therefore, this study is proposed to optimise the design of WDSs considering BTM solar energy sources. A pressurised irrigation supply system in Victoria, Australia has been used as the case study system. In this paper, the design of a real-world WDS has been formulated as a multi-objective optimisation problem to investigate the trade-offs between the total life cycle cost and total life cycle greenhouse gas (GHG) emissions under various discount rates scenarios used to estimate the operational cost and emissions throughout the service life of the system. It has been found that both the total life cycle cost and GHG emissions have been reduced significantly when BTM solar energy is incorporated. In addition, with the same solar photovoltaic (PV) size, the optimal pipe diameters, as well as the objective function values are sensitive to the discount rate values that have been used,
- 18 July 2022
- Published by Universitat Politecnica de Valencia
Open AccessWater distribution system design with behind-the-meter solar energy under various discount rates
Water distribution systems (WDSs) are essential parts of urban and rural infrastructure systems. The energy consumption including associated costs and GHG emissions for distributing water has increased in recent years. As a result, behind-the-meter (BTM) energy systems such as solar panels and energy storage facilities have been installed by water utilities to reduce energy consumption from the centralised energy grid. There has been a lot of research on the optimisation of the design of WDSs, however, many of these works have not considered BTM energy options or have incorporated BTM energy options in an ad-hoc fashion. Therefore, this study is proposed to optimise the design of WDSs considering BTM solar energy sources. A pressurised irrigation supply system in Victoria, Australia has been used as the case study system. In this paper, the design of a real-world WDS has been formulated as a multi-objective optimisation problem to investigate the trade-offs between the total life cycle cost and total life cycle greenhouse gas (GHG) emissions under various discount rates scenarios used to estimate the operational cost and emissions throughout the service life of the system. It has been found that both the total life cycle cost and GHG emissions have been reduced significantly when BTM solar energy is incorporated. In addition, with the same solar photovoltaic (PV) size, the optimal pipe diameters, as well as the objective function values are sensitive to the discount rate values that have been used,