Xiangzhen Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiangzhen Yang has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Yan Du
School of Electrical Engineering and Automation, Hefei University of Technology, Hefei 230009, China
4 shared publications - Jian Zhang
School of Electrical Engineering and Automation, Hefei University of Technology, Hefei, China
3 shared publications - Jianhui Su
School of Electrical Engineering and Automation, Hefei University of Technology, Hefei, China
3 shared publications Yan Du
School of Electrical Engineering and Automation, Hefei University of Technology, Hefei, China
3 shared publications- Yong Shi
School of Electrical Engineering and Automation, Hefei University of Technology, Hefei, China
3 shared publications Jianhui Su
School of Electrical Engineering and Automation, Hefei University of Technology, Hefei, China
2 shared publications
Latest Publications
- 7 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (4) , 4133-4143
Hybrid SVM for Enhanced Efficiency of 3L ANPC Inverter With Full ZVS Range
The zero-voltage-switching variable frequency control (ZVS-VF) can achieve ZVS without auxiliary circuit. Nevertheless, it will increase switching losses under light load, and conduction losses under heavy load, thus affecting efficiency. This is particularly evident in scenarios with varying DC side voltage and load power (e.g. photovoltaic systems). To address this issue, our proposed continuous space vector modulation (CSVM)-Improved discontinuous space vector modulation (IDSVM) hybrid strategy can improve the efficiency at both light and heavy loads under various DC side voltages, when employing ZVS-VF to a 3L inverter. This is achieved by leveraging the losses performance of diverse modulations, CSVM is chosen to reduce switching losses under light load, while IDSVM is selected to limit conduction losses under heavy load. Additionally, with the proposed hybrid modulation, the full ZVS range can be realized in the 3L inverter. The modulation transition point is determined by the power losses analysis, ZVS range analysis and smooth transition constraint. It can be adaptively adjusted to achieve smooth transition of different modulation methods under varying operating conditions. The experimental results from a 10kW 3L Active Neutral-Point-Clamped (ANPC) inverter demonstrate that the proposed strategy improves efficiency by 3.7% for light load and 1.94% for full load compared to the conventional constant frequency control.
- 7 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (4) , 4133-4143
Hybrid SVM for Enhanced Efficiency of 3L ANPC Inverter With Full ZVS Range
The zero-voltage-switching variable frequency control (ZVS-VF) can achieve ZVS without auxiliary circuit. Nevertheless, it will increase switching losses under light load, and conduction losses under heavy load, thus affecting efficiency. This is particularly evident in scenarios with varying DC side voltage and load power (e.g. photovoltaic systems). To address this issue, our proposed continuous space vector modulation (CSVM)-Improved discontinuous space vector modulation (IDSVM) hybrid strategy can improve the efficiency at both light and heavy loads under various DC side voltages, when employing ZVS-VF to a 3L inverter. This is achieved by leveraging the losses performance of diverse modulations, CSVM is chosen to reduce switching losses under light load, while IDSVM is selected to limit conduction losses under heavy load. Additionally, with the proposed hybrid modulation, the full ZVS range can be realized in the 3L inverter. The modulation transition point is determined by the power losses analysis, ZVS range analysis and smooth transition constraint. It can be adaptively adjusted to achieve smooth transition of different modulation methods under varying operating conditions. The experimental results from a 10kW 3L Active Neutral-Point-Clamped (ANPC) inverter demonstrate that the proposed strategy improves efficiency by 3.7% for light load and 1.94% for full load compared to the conventional constant frequency control.
- 18 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (1) , 1160-1171
Comprehensive Optimization of ZVS Variable Frequency Control for SiC/Si HANPC Converter
The growing demand for high-efficiency power con-verters with silicon carbide (SiC) devices at high switching frequencies has fueled an interest in non-auxiliary circuit-based soft switching techniques, particularly the variable switching frequency control for zero-voltage switching (VF-ZVS). Besides increasing the Total Harmonic Distortion (THD), applying the full ZVS range to three-phase SiC/Si Hybrid Active Neutral Point Clamped (HANPC) converters leads to a rise in conduction loss. This issue is exacerbated by the use of Si IGBT, as it generates significantly more conduction loss than SiC MOSFET in medium and small power HANPC. Consequently, a power loss optimized VF-ZVS (OVF-ZVS), based on a precise loss model, is proposed to enhance efficiency by considering the effect of the current ripple on device loss. This OVF-ZVS optimizes the switching frequency to minimize the total loss of three-phase switching devices across all load ranges. Meanwhile, the variable switching frequency range and LCL parameters are optimized to strike a balance between superior output current quality, power density, etc. Simulation and exper-imentation using a 10kW HANPC converter prototype illustrate the effectiveness of the proposed comprehensive optimization, further highlighting the reduction in THD and device loss.
- 18 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (1) , 1160-1171
Comprehensive Optimization of ZVS Variable Frequency Control for SiC/Si HANPC Converter
The growing demand for high-efficiency power con-verters with silicon carbide (SiC) devices at high switching frequencies has fueled an interest in non-auxiliary circuit-based soft switching techniques, particularly the variable switching frequency control for zero-voltage switching (VF-ZVS). Besides increasing the Total Harmonic Distortion (THD), applying the full ZVS range to three-phase SiC/Si Hybrid Active Neutral Point Clamped (HANPC) converters leads to a rise in conduction loss. This issue is exacerbated by the use of Si IGBT, as it generates significantly more conduction loss than SiC MOSFET in medium and small power HANPC. Consequently, a power loss optimized VF-ZVS (OVF-ZVS), based on a precise loss model, is proposed to enhance efficiency by considering the effect of the current ripple on device loss. This OVF-ZVS optimizes the switching frequency to minimize the total loss of three-phase switching devices across all load ranges. Meanwhile, the variable switching frequency range and LCL parameters are optimized to strike a balance between superior output current quality, power density, etc. Simulation and exper-imentation using a 10kW HANPC converter prototype illustrate the effectiveness of the proposed comprehensive optimization, further highlighting the reduction in THD and device loss.
- 8 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (1) , 1277-1287
PEMFC Fault Diagnosis Based on an Equivalent Circuit and OS-ELM Framework
Most current proton exchange membrane fuel cell (PEMFC) fault diagnosis models are not updated after offline training is completed, so they cannot learn new data features. For this problem, a PEMFC fault diagnosis model based on an equivalent circuit and an online sequential extreme learning machine (OS-ELM) framework is proposed. Under different operating conditions, the range of equivalent circuit element values is different, which is conducive to fault diagnosis. Element values constitute a dataset, from which OS-ELM is used to learn data features, and PEMFC fault diagnosis and isolation can be accomplished. OS-ELM has online learning capability. During the operation of PEMFC, equivalent circuit fitting is performed on multiple sets of sample data obtained using electrical impedance spectroscopy (EIS). Optimized fuzzy C-means (FCM) is used to cluster and partition sample data for online updating of OS-ELM models. The experimental results show that the proposed PEMFC fault diagnosis model not only has the speed and accuracy of fault diagnosis but also has the ability to learn fault characteristics online.
- 8 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (1) , 1277-1287
PEMFC Fault Diagnosis Based on an Equivalent Circuit and OS-ELM Framework
Most current proton exchange membrane fuel cell (PEMFC) fault diagnosis models are not updated after offline training is completed, so they cannot learn new data features. For this problem, a PEMFC fault diagnosis model based on an equivalent circuit and an online sequential extreme learning machine (OS-ELM) framework is proposed. Under different operating conditions, the range of equivalent circuit element values is different, which is conducive to fault diagnosis. Element values constitute a dataset, from which OS-ELM is used to learn data features, and PEMFC fault diagnosis and isolation can be accomplished. OS-ELM has online learning capability. During the operation of PEMFC, equivalent circuit fitting is performed on multiple sets of sample data obtained using electrical impedance spectroscopy (EIS). Optimized fuzzy C-means (FCM) is used to cluster and partition sample data for online updating of OS-ELM models. The experimental results show that the proposed PEMFC fault diagnosis model not only has the speed and accuracy of fault diagnosis but also has the ability to learn fault characteristics online.
- 1 August 2023
- Published by Springer Nature in Journal of Power Electronics
- Vol. 23 (12) , 1867-1879
Online broadband grid impedance estimation method based on multi-objective optimized random PWM
- 1 August 2023
- Published by Springer Nature in Journal of Power Electronics
- Vol. 23 (12) , 1867-1879
Online broadband grid impedance estimation method based on multi-objective optimized random PWM
- 11 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (1) , 1183-1195
Bidirectional ZVS Operation of All Switches for a DAB Converter Over a Full Range of Loads With Optimized Current Stress
All-switches zero voltage switching (ZVS) and lower current stress are the most important challenges for improving the efficiency of dual-active-bridge (DAB) converters operating in the bidirectional full-load range and wide voltage range applications. Triple-phase-shift (TPS) has three control degrees of freedom and it is a more flexible way to extend the ZVS range in all kinds of operating conditions. In order to improve the efficiency of DAB converters, a new optimal current stress in TPS (OCS-TPS) control is proposed to minimize the current stress as well as achieve all-switches ZVS within the bidirectional full-load range and wide voltage range applications. Firstly, seven specific switching modes satisfying the ZVS conditions under step-up and step-down are selected from 12 TPS switching modes. Secondly, the issue of current stress minimization is turned into an extreme optimization problem with equality constraints of desired transmission power and inequality constraints of ZVS conditions in selected switching modes. The Karush-Kuhn-Tucker (KKT) algorithm is employed to solve this optimization issue. Then two switching modes are chosen to form the high-load range ZVS and low-load range partial-switches ZCS/ZVS in the case of step-down and step-up operations respectively. Therefore, the phase-shift ratios of selected switching modes in the low-load range are further optimized by adding an offset value to achieve all-switches ZVS. Finally, the effectiveness of the proposed strategy is verified by the experimental results.
- 11 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (1) , 1183-1195
Bidirectional ZVS Operation of All Switches for a DAB Converter Over a Full Range of Loads With Optimized Current Stress
All-switches zero voltage switching (ZVS) and lower current stress are the most important challenges for improving the efficiency of dual-active-bridge (DAB) converters operating in the bidirectional full-load range and wide voltage range applications. Triple-phase-shift (TPS) has three control degrees of freedom and it is a more flexible way to extend the ZVS range in all kinds of operating conditions. In order to improve the efficiency of DAB converters, a new optimal current stress in TPS (OCS-TPS) control is proposed to minimize the current stress as well as achieve all-switches ZVS within the bidirectional full-load range and wide voltage range applications. Firstly, seven specific switching modes satisfying the ZVS conditions under step-up and step-down are selected from 12 TPS switching modes. Secondly, the issue of current stress minimization is turned into an extreme optimization problem with equality constraints of desired transmission power and inequality constraints of ZVS conditions in selected switching modes. The Karush-Kuhn-Tucker (KKT) algorithm is employed to solve this optimization issue. Then two switching modes are chosen to form the high-load range ZVS and low-load range partial-switches ZCS/ZVS in the case of step-down and step-up operations respectively. Therefore, the phase-shift ratios of selected switching modes in the low-load range are further optimized by adding an offset value to achieve all-switches ZVS. Finally, the effectiveness of the proposed strategy is verified by the experimental results.
- 19 August 2021
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 17 (1) , 295-305
Hierarchical Voltage Control Strategy in Multi-bus Islanded Microgrid Based on Secondary Voltage Control Bus Selection Method
- 19 August 2021
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 17 (1) , 295-305
Hierarchical Voltage Control Strategy in Multi-bus Islanded Microgrid Based on Secondary Voltage Control Bus Selection Method
- 4 April 2019
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 14 (3) , 1235-1246
Adaptive Virtual Impedance of Grid-Tied Inverters to Enhance the Stability in a Weak Grid
- 4 April 2019
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 14 (3) , 1235-1246
Adaptive Virtual Impedance of Grid-Tied Inverters to Enhance the Stability in a Weak Grid
- 25 August 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 4 (4) , 1236-1246
An Optimal Secondary Voltage Control Strategy for an Islanded Multibus Microgrid
In this paper, an optimal secondary voltage control (SVC) strategy has been proposed for an islanded multibus microgrid (MG). The proposed strategy consists of a multiobjective function, power flow equality constraints, and four sets of inequality constraints. The multiobjective function aims to achieve a compromise between multibus voltage regulation and reactive power distribution among voltage modulation units by taking full advantage of both droop-controlled and PQ-controlled distributed energy resource (DER) units in the MG. Power flow equations for an islanded MG with or without secondary frequency control were considered as equality constraints. The limits of DER capacities, bus voltages, power flows on distribution lines, and system frequency must be accommodated during the process of solving the proposed SVC control strategy iteratively using the primal-dual interior-point method. Finally, simulation results have been presented to validate the feasibility of the proposed optimal SVC strategy.
- 25 August 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 4 (4) , 1236-1246
An Optimal Secondary Voltage Control Strategy for an Islanded Multibus Microgrid
In this paper, an optimal secondary voltage control (SVC) strategy has been proposed for an islanded multibus microgrid (MG). The proposed strategy consists of a multiobjective function, power flow equality constraints, and four sets of inequality constraints. The multiobjective function aims to achieve a compromise between multibus voltage regulation and reactive power distribution among voltage modulation units by taking full advantage of both droop-controlled and PQ-controlled distributed energy resource (DER) units in the MG. Power flow equations for an islanded MG with or without secondary frequency control were considered as equality constraints. The limits of DER capacities, bus voltages, power flows on distribution lines, and system frequency must be accommodated during the process of solving the proposed SVC control strategy iteratively using the primal-dual interior-point method. Finally, simulation results have been presented to validate the feasibility of the proposed optimal SVC strategy.