- Open Access
Effect of Solar Irradiation Inter-Annual Variability on PV and CSP Power Plants Production Capacity: Portugal Case-Study
The sizing of solar energy power plants is usually made using typical meteorological years, which disregards the inter-annual variability of the solar resource. Nevertheless, such variability is crucial for the bankability of these projects because it impacts on the production goals set at the time of the supply agreement. For that reason, this study aims to fill the gap in the existing literature and analyse the impact that solar resource variability has on solar power plant production as applied to the case of Portugal (southern Europe). To that end, 17 years (2003–2019) of meteorological data from a network of 90 ground stations hosted by the Portuguese Meteorological Service is examined. Annual capacity factor regarding photovoltaic (PV) and concentrating solar power (CSP) plants is computed using the System Advisor Model, used here for solar power performance simulations. In terms of results, while a long-term trend for increase in annual irradiation is found for Global Horizontal Irradiance (GHI) and Direct Normal Irradiance (DNI), 0.4148 and 3.2711 kWh/m2/year, respectively, consistent with a solar brightening period, no corresponding trend is found for PV or CSP production. The latter is attributed to the long-term upward trend of 0.0231 °C/year in annual average ambient temperature, which contributes to PV and CSP efficiency reduction. Spatial analysis of inter-annual relative variability for GHI and DNI shows a reduction in variability from the north to the south of the country, as well as for the respective power plant productions. Particularly, for PV, inter-annual variability ranges between 2.45% and 12.07% in Faro and Santarém, respectively, while higher values are generally found for CSP, 3.71% in Faro and 16.04% in São Pedro de Moel. These results are a contribution to future instalments of PV and CSP systems in southern Portugal, a region with very favourable conditions for solar energy harvesting, due to the combination of high production capacity and low inter-annual variability.
Open AccessEffect of Solar Irradiation Inter-Annual Variability on PV and CSP Power Plants Production Capacity: Portugal Case-Study
The sizing of solar energy power plants is usually made using typical meteorological years, which disregards the inter-annual variability of the solar resource. Nevertheless, such variability is crucial for the bankability of these projects because it impacts on the production goals set at the time of the supply agreement. For that reason, this study aims to fill the gap in the existing literature and analyse the impact that solar resource variability has on solar power plant production as applied to the case of Portugal (southern Europe). To that end, 17 years (2003–2019) of meteorological data from a network of 90 ground stations hosted by the Portuguese Meteorological Service is examined. Annual capacity factor regarding photovoltaic (PV) and concentrating solar power (CSP) plants is computed using the System Advisor Model, used here for solar power performance simulations. In terms of results, while a long-term trend for increase in annual irradiation is found for Global Horizontal Irradiance (GHI) and Direct Normal Irradiance (DNI), 0.4148 and 3.2711 kWh/m2/year, respectively, consistent with a solar brightening period, no corresponding trend is found for PV or CSP production. The latter is attributed to the long-term upward trend of 0.0231 °C/year in annual average ambient temperature, which contributes to PV and CSP efficiency reduction. Spatial analysis of inter-annual relative variability for GHI and DNI shows a reduction in variability from the north to the south of the country, as well as for the respective power plant productions. Particularly, for PV, inter-annual variability ranges between 2.45% and 12.07% in Faro and Santarém, respectively, while higher values are generally found for CSP, 3.71% in Faro and 16.04% in São Pedro de Moel. These results are a contribution to future instalments of PV and CSP systems in southern Portugal, a region with very favourable conditions for solar energy harvesting, due to the combination of high production capacity and low inter-annual variability.
- Open Access
Development of a Simple Methodology Using Meteorological Data to Evaluate Concentrating Solar Power Production Capacity
Evaluation of the Concentrating Solar Power capacity factor is critical to support decision making on possible regional energy investments. For such evaluations, the System Advisor Model is used to perform capacity factor assessments. Among the required data, information concerning direct normal irradiance is fundamental. In this context, the Engerer model is used to estimate direct normal irradiance hourly values out of global horizontal irradiance ground measurements and other observed meteorological variables. Model parameters were calibrated for direct normal irradiance measurements in Évora (Southern Portugal), being then applied to a network of 90 stations, part of the Portuguese Meteorological Service. From the modelled direct normal irradiance, and for stations that comprise 20 years of data, typical meteorological years were determined. Finally, to identify locations of interest for possible installations of Concentrating Solar Power systems, annual direct normal irradiance availabilities and the respective capacity factor, for a predefined power plant using the System Advisor Model, were produced. Results show annual direct normal irradiance availabilities and capacity factors of up to ~2310 kWh/m2 and ~36.2% in Castro Marim and in Faro, respectively. Moreover, this study supports energy policies that would promote Concentrating Solar Power investments in Southern Portugal (Alentejo and Algarve regions) and eastern centre Portugal (Beira Interior region), which have capacity factors above 30%.
Open AccessDevelopment of a Simple Methodology Using Meteorological Data to Evaluate Concentrating Solar Power Production Capacity
Evaluation of the Concentrating Solar Power capacity factor is critical to support decision making on possible regional energy investments. For such evaluations, the System Advisor Model is used to perform capacity factor assessments. Among the required data, information concerning direct normal irradiance is fundamental. In this context, the Engerer model is used to estimate direct normal irradiance hourly values out of global horizontal irradiance ground measurements and other observed meteorological variables. Model parameters were calibrated for direct normal irradiance measurements in Évora (Southern Portugal), being then applied to a network of 90 stations, part of the Portuguese Meteorological Service. From the modelled direct normal irradiance, and for stations that comprise 20 years of data, typical meteorological years were determined. Finally, to identify locations of interest for possible installations of Concentrating Solar Power systems, annual direct normal irradiance availabilities and the respective capacity factor, for a predefined power plant using the System Advisor Model, were produced. Results show annual direct normal irradiance availabilities and capacity factors of up to ~2310 kWh/m2 and ~36.2% in Castro Marim and in Faro, respectively. Moreover, this study supports energy policies that would promote Concentrating Solar Power investments in Southern Portugal (Alentejo and Algarve regions) and eastern centre Portugal (Beira Interior region), which have capacity factors above 30%.