Jiangang Bi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiangang Bi has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Yuan Xu
China Electric Power Research Institute
5 shared publications - Shuai Yuan
China Electric Power Research Institute
4 shared publications - Yanpeng Gong
China Electric Power Research Institute
3 shared publications - Fei Du
China Electric Power Research Institute
2 shared publications - Jinpeng Jiang
China Electric Power Research Institute
2 shared publications - Bin Liu
Faculty of Eletrical Engineering, Shanghai University of Electric Power, Shanghai 200090, China
1 shared publication
Latest Publications
- Open Access
Frequency Dependence of Air Breakdown and Investigation of Its Electro-Optical Characteristics
With the expanding frequency range of power equipment, understanding the frequency-dependent insulation performance of air becomes crucial. To address this, this paper establishes an integrated electrical–optical measurement platform for air breakdown to study the variation patterns of electrical and spectral characteristics of air breakdown at different frequencies. The effects and underlying mechanisms of different frequencies (20 Hz, 50 Hz, and 1 kHz) on the breakdown voltage are explored. Experimental results indicate that the air breakdown voltage increases with frequency as follows: from 17.7 kV at 20 Hz to 18.0 kV at 50 Hz (1.7% increase) and further to 18.9 kV at 1 kHz (5.0% increase from 50 Hz), representing a total increase of 6.8% across the 20 Hz to 1 kHz range. Regarding spectral characteristics, the spectral line intensity enhances with an increase in frequency. Compared to 20 Hz and 50 Hz, the spectral lines of nitrogen ions and oxygen ions become distinctly visible at 1 kHz, the Stark broadening phenomenon intensifies, and transitions from higher vibrational energy levels are enhanced relative to those from lower levels. Analysis via the Boltzmann plot method reveals a negative correlation between electron temperature (Te) and frequency, while the ionization degree (η) shows a positive correlation. Concurrently, the electron drift velocity (vd) increases with frequency, whereas the mean free path decreases (λ). Based on the parallel-plate capacitor model, the air breakdown under the experimental conditions of this study is dominated by collision ionization. As frequency increases, dielectric recovery slows down, and the memory effect strengthens. The interplay between these two competing factors leads to an increase in breakdown voltage with an increase in frequency within the 20 Hz to 1 kHz range. The findings of this study demonstrate that air breakdown exhibits significant frequency dependence, and its breakdown voltage shows statistical distribution characteristics (Weibull parameters) that vary with frequency. This article provides a reference basis for the design of sinusoidal air insulation in the 20 Hz to 1 kHz frequency range.
Open AccessFrequency Dependence of Air Breakdown and Investigation of Its Electro-Optical Characteristics
With the expanding frequency range of power equipment, understanding the frequency-dependent insulation performance of air becomes crucial. To address this, this paper establishes an integrated electrical–optical measurement platform for air breakdown to study the variation patterns of electrical and spectral characteristics of air breakdown at different frequencies. The effects and underlying mechanisms of different frequencies (20 Hz, 50 Hz, and 1 kHz) on the breakdown voltage are explored. Experimental results indicate that the air breakdown voltage increases with frequency as follows: from 17.7 kV at 20 Hz to 18.0 kV at 50 Hz (1.7% increase) and further to 18.9 kV at 1 kHz (5.0% increase from 50 Hz), representing a total increase of 6.8% across the 20 Hz to 1 kHz range. Regarding spectral characteristics, the spectral line intensity enhances with an increase in frequency. Compared to 20 Hz and 50 Hz, the spectral lines of nitrogen ions and oxygen ions become distinctly visible at 1 kHz, the Stark broadening phenomenon intensifies, and transitions from higher vibrational energy levels are enhanced relative to those from lower levels. Analysis via the Boltzmann plot method reveals a negative correlation between electron temperature (Te) and frequency, while the ionization degree (η) shows a positive correlation. Concurrently, the electron drift velocity (vd) increases with frequency, whereas the mean free path decreases (λ). Based on the parallel-plate capacitor model, the air breakdown under the experimental conditions of this study is dominated by collision ionization. As frequency increases, dielectric recovery slows down, and the memory effect strengthens. The interplay between these two competing factors leads to an increase in breakdown voltage with an increase in frequency within the 20 Hz to 1 kHz range. The findings of this study demonstrate that air breakdown exhibits significant frequency dependence, and its breakdown voltage shows statistical distribution characteristics (Weibull parameters) that vary with frequency. This article provides a reference basis for the design of sinusoidal air insulation in the 20 Hz to 1 kHz frequency range.
- 25 February 2025
- Published by Springer Nature
- p. 16-25
Effectiveness Test and Application of Alarm Strategy for Ultra-High Frequency Online Monitoring Equipment
- 25 February 2025
- Published by Springer Nature
- p. 16-25
Effectiveness Test and Application of Alarm Strategy for Ultra-High Frequency Online Monitoring Equipment
- 25 February 2025
- Published by Springer Nature
- p. 146-153
Research on the Effectiveness of On-Line Monitoring Sensor Distribution in UHV GIS
- 25 February 2025
- Published by Springer Nature
- p. 146-153
Research on the Effectiveness of On-Line Monitoring Sensor Distribution in UHV GIS
- 25 February 2025
- Published by Springer Nature
- p. 154-162
Study on the Development Process of Partial Discharge Before GIS Fault Flashover
- 25 February 2025
- Published by Springer Nature
- p. 154-162
Study on the Development Process of Partial Discharge Before GIS Fault Flashover
- 14 February 2025
- Published by Springer Nature
- p. 583-589
Surface Charge Accumulation Characteristics of AC GIS Partial Discharge Induced by Metal Particles on the Surface of Post Insulator
- 14 February 2025
- Published by Springer Nature
- p. 583-589
Surface Charge Accumulation Characteristics of AC GIS Partial Discharge Induced by Metal Particles on the Surface of Post Insulator
- 3 December 2024
- Published by Springer Nature
- p. 38-45
Research on Magnetic Field Sensor Based on Tapered Fiber
- 3 December 2024
- Published by Springer Nature
- p. 38-45
Research on Magnetic Field Sensor Based on Tapered Fiber
- 11 May 2023
- Published by Springer Nature
- p. 479-486
Research on Defect Simulation and Diagnosis Method of On-Load Tap Changer
- 11 May 2023
- Published by Springer Nature
- p. 479-486
Research on Defect Simulation and Diagnosis Method of On-Load Tap Changer
- 30 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 64 (4) , 1058-1066
Novel Spiral-Gap Shielding Shell for a Rogowski Current Sensor
Rogowski current sensors play an important role in detecting the condition of electrical power substation equipment. An electromagnetic field shielding shell is necessary for some of these sensors to operate correctly, especially those with large diameters and small heights. These are used for frequency-response analysis in power transformers. In this study, the magnetic-shielding effectiveness of a normal C-type metal shell was tested and simulated. The distribution and direction of the magnetic field were analyzed using finite-element simulation calculations to reveal the reasons for its poor shielding effectiveness. It was found that the magnetic field induced by an interference current crosses the shell and enters its cavity through the gap in its inner wall. Shells with larger inner-diameter-to-height ratios have worse magnetic-shielding effectiveness. Therefore, a novel shell structure with a spiral gap is proposed here. The magnetic-shielding effectiveness of this new type of shell was analyzed by further simulations and verified in experimental tests. The results showed that a shell with a spiral gap has better shielding effectiveness when it has a long gap. In addition, the spiral gap was found not to inhibit the current-measurement function of the sensor. This provides a new approach to the design of electromagnetic shielding shells for Rogowski sensors.
- 30 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 64 (4) , 1058-1066
Novel Spiral-Gap Shielding Shell for a Rogowski Current Sensor
Rogowski current sensors play an important role in detecting the condition of electrical power substation equipment. An electromagnetic field shielding shell is necessary for some of these sensors to operate correctly, especially those with large diameters and small heights. These are used for frequency-response analysis in power transformers. In this study, the magnetic-shielding effectiveness of a normal C-type metal shell was tested and simulated. The distribution and direction of the magnetic field were analyzed using finite-element simulation calculations to reveal the reasons for its poor shielding effectiveness. It was found that the magnetic field induced by an interference current crosses the shell and enters its cavity through the gap in its inner wall. Shells with larger inner-diameter-to-height ratios have worse magnetic-shielding effectiveness. Therefore, a novel shell structure with a spiral gap is proposed here. The magnetic-shielding effectiveness of this new type of shell was analyzed by further simulations and verified in experimental tests. The results showed that a shell with a spiral gap has better shielding effectiveness when it has a long gap. In addition, the spiral gap was found not to inhibit the current-measurement function of the sensor. This provides a new approach to the design of electromagnetic shielding shells for Rogowski sensors.
- 9 September 2016
- Published by Springer Nature in Cluster Computing
- Vol. 19 (4) , 1951-1962
An approach for Condition Based Maintenance strategy optimization oriented to multi-source data
- 9 September 2016
- Published by Springer Nature in Cluster Computing
- Vol. 19 (4) , 1951-1962
An approach for Condition Based Maintenance strategy optimization oriented to multi-source data