Alexandra Mena-Serrano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alexandra Mena-Serrano has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Alessandra Reis
Department of Restorative Dentistry State University of Ponta Grossa Ponta Grossa Paraná Brazil
7 shared publications - Alessandro Dourado Loguercio
Department of Restorative Dentistry State University of Ponta Grossa Ponta Grossa Brazil
4 shared publications - Michael Willian Favoreto
Department of Restorative Dentistry, University of São Paulo, São Paulo, Brazil
4 shared publications Alessandro Dourado Loguercio
3 shared publicationsAlessandra Reis
2 shared publications- Byron Velasquez Ron
Carrera de Odontología, Universidad de Las Américas (UDLA) Ecuador, Quito 170102, Ecuador
2 shared publications
Latest Publications
- Open Access
- 25 April 2024
- Published by Universidad Nacional Autonoma de Mexico in Revista Odontológica Mexicana Órgano Oficial de la Facultad de Odontología UNAM
- Vol. 26 (2)
Zonas de estrés en implantes dentales sinterizados valorados por elemento finito
Introducción: los implantes de diseño personalizado en dientes permiten su colocación inmediata posextracción con buena adaptación al alveolo, acortando los tiempos de espera en casos en los que se requiera regeneración, o sea en los implantes convencionales. Objetivo: comparar zonas de estrés entre implantes dentales personalizados sinterizados, implantes convencionales y dientes mediante el método de elemento finito. Material y métodos: se generaron tres modelos diseñados por computadora: implante convencional, implante personalizado y diente natural (segundo premolar superior); sometidos a tres fuerzas fijas perpendiculares al eje longitudinal del diente: 7.5 N, 100 N y 150 N. Resultados: el implante personalizado, en comparación con el implante convencional, tiene mejor distribución de fuerzas. Al compararse con el diente, la mayor concentración de fuerzas se encuentra en el inicio de la masticación, disipándose en toda su estructura. Conclusiones: el implante de diseño personalizado distribuye mejor las fuerzas oclusales en todo su eje limitando las zonas de estrés, y mantiene hueso y tejido conectivo mejorando el perfil de emergencia. No existe posibilidad de fractura de abutments definitivos o tornillos pasantes.
- 25 April 2024
- Published by Universidad Nacional Autonoma de Mexico in Revista Odontológica Mexicana Órgano Oficial de la Facultad de Odontología UNAM
- Vol. 26 (2)
Open AccessZonas de estrés en implantes dentales sinterizados valorados por elemento finito
Introducción: los implantes de diseño personalizado en dientes permiten su colocación inmediata posextracción con buena adaptación al alveolo, acortando los tiempos de espera en casos en los que se requiera regeneración, o sea en los implantes convencionales. Objetivo: comparar zonas de estrés entre implantes dentales personalizados sinterizados, implantes convencionales y dientes mediante el método de elemento finito. Material y métodos: se generaron tres modelos diseñados por computadora: implante convencional, implante personalizado y diente natural (segundo premolar superior); sometidos a tres fuerzas fijas perpendiculares al eje longitudinal del diente: 7.5 N, 100 N y 150 N. Resultados: el implante personalizado, en comparación con el implante convencional, tiene mejor distribución de fuerzas. Al compararse con el diente, la mayor concentración de fuerzas se encuentra en el inicio de la masticación, disipándose en toda su estructura. Conclusiones: el implante de diseño personalizado distribuye mejor las fuerzas oclusales en todo su eje limitando las zonas de estrés, y mantiene hueso y tejido conectivo mejorando el perfil de emergencia. No existe posibilidad de fractura de abutments definitivos o tornillos pasantes.
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 35, e24-5793
Hydrogen Peroxide in the Pulp Chamber and Color Change in Maxillary Anterior Teeth After In-Office Bleaching
While the literature has noted variations in hydrogen peroxide (HP) permeability, and consequently, tooth sensitivity among different types of anterior teeth, there is a scarcity of research on this specific topic. This study evaluated HP permeability and color change (CC) in different groups of human maxillary anterior teeth (canines, lateral incisors, and central incisors) after in-office bleaching with HP at 35%. Thirty teeth maxillary anterior (n=10) were bleached with HP at 35% gel in one session of three 15-minutes applications. Buccal thickness (mm) was measured from images obtained using cone beam computed tomography. The concentration of HP (µg/mL) that reached the pulp chamber was assessed using UV-Vis spectrophotometry. CC (WID, ∆Eab, and ∆E00) was evaluated before and after bleaching with a digital spectrophotometer. One-way ANOVA and Tukey’s test were applied to statistically evaluate the data for buccal thickness, HP permeability, and CC (α=0.05). Comparison between thickness and HP permeability was performed using Pearson's correlation. Thicker teeth, such as canines, had lower HP amounts inside the pulp chamber compared to central and lateral incisors. Despite the significant effect of buccal thickness on HP permeability (p0.05). The difference in buccal thickness among the superior anterior teeth does not interfere with CC. However, a thinner buccal wall thickness is associated with greater HP permeability detected in the pulp after in-office bleaching.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 35, e24-5793
Open AccessHydrogen Peroxide in the Pulp Chamber and Color Change in Maxillary Anterior Teeth After In-Office Bleaching
While the literature has noted variations in hydrogen peroxide (HP) permeability, and consequently, tooth sensitivity among different types of anterior teeth, there is a scarcity of research on this specific topic. This study evaluated HP permeability and color change (CC) in different groups of human maxillary anterior teeth (canines, lateral incisors, and central incisors) after in-office bleaching with HP at 35%. Thirty teeth maxillary anterior (n=10) were bleached with HP at 35% gel in one session of three 15-minutes applications. Buccal thickness (mm) was measured from images obtained using cone beam computed tomography. The concentration of HP (µg/mL) that reached the pulp chamber was assessed using UV-Vis spectrophotometry. CC (WID, ∆Eab, and ∆E00) was evaluated before and after bleaching with a digital spectrophotometer. One-way ANOVA and Tukey’s test were applied to statistically evaluate the data for buccal thickness, HP permeability, and CC (α=0.05). Comparison between thickness and HP permeability was performed using Pearson's correlation. Thicker teeth, such as canines, had lower HP amounts inside the pulp chamber compared to central and lateral incisors. Despite the significant effect of buccal thickness on HP permeability (p0.05). The difference in buccal thickness among the superior anterior teeth does not interfere with CC. However, a thinner buccal wall thickness is associated with greater HP permeability detected in the pulp after in-office bleaching.
- Open Access
- 4 November 2023
- Published by Wiley in International Journal of Dentistry
- Vol. 2023, 1-7
Effect of Sodium Ascorbate, Grape Seed Extract, and Aloe Vera Application after In-Office Bleaching on the Bond Strength of Enamel: A 3-Year Evaluation
Introduction. Dental bleaching is the first choice to improve smile esthetics, but, in some cases, it needs to be associated with resin composite restoration to obtain a satisfactory result. Unfortunately, the bonding of resin-based materials can be impaired due to residual oxygen molecules, which can decrease the durability of the restoration. Objectives. To evaluate the effect of the antioxidant application on the bond strength of bleached enamel after 24 hr and 3 years of water storage. Methods. In total, 84 bovine teeth were used in this study. Of these, 77 were bleached with 35% hydrogen peroxide in a single session for three cycles of 15 min. Then, the specimens were divided into groups (n = 7 each): control (without bleaching), without antioxidant (WA) use; application of 10% sodium ascorbate (SA) gel, grape seed (GS) extract, and aloe vera (AV). The restorative procedure was performed immediately after bleaching, 7 and 14 days after bleaching. Specimens were sectioned and evaluated using microtensile bond strength (μTBS). Half of the resin-enamel sticks were tested after 24 hr, and the remaining half after 3 years of water storage. µTBS data were analyzed using a three-way analysis of variance, Tukey’s test, and Dunnett’s test. Results. The lowest µTBS values were observed when the restoration was performed immediately after bleaching in the AV, GS, and WA groups when compared with the SA group ( ). However, no significant differences were observed among all groups after 3 years of water storage ( ). Conclusions. SA at 10% was the most effective antioxidant agent for improving the immediate bond strength. However, independent of the antioxidant agent used, the bond strength values were maintained or recovered after 3 years of water storage. SA at 10% could be used to avoid delayed bonding procedures after in-office whitening without compromising bond strength over time. Clinical Significance. The use of antioxidants after dental bleaching can be effective in improving the bonding durability of the adhesive restorations.
- 4 November 2023
- Published by Wiley in International Journal of Dentistry
- Vol. 2023, 1-7
Open AccessEffect of Sodium Ascorbate, Grape Seed Extract, and Aloe Vera Application after In-Office Bleaching on the Bond Strength of Enamel: A 3-Year Evaluation
Introduction. Dental bleaching is the first choice to improve smile esthetics, but, in some cases, it needs to be associated with resin composite restoration to obtain a satisfactory result. Unfortunately, the bonding of resin-based materials can be impaired due to residual oxygen molecules, which can decrease the durability of the restoration. Objectives. To evaluate the effect of the antioxidant application on the bond strength of bleached enamel after 24 hr and 3 years of water storage. Methods. In total, 84 bovine teeth were used in this study. Of these, 77 were bleached with 35% hydrogen peroxide in a single session for three cycles of 15 min. Then, the specimens were divided into groups (n = 7 each): control (without bleaching), without antioxidant (WA) use; application of 10% sodium ascorbate (SA) gel, grape seed (GS) extract, and aloe vera (AV). The restorative procedure was performed immediately after bleaching, 7 and 14 days after bleaching. Specimens were sectioned and evaluated using microtensile bond strength (μTBS). Half of the resin-enamel sticks were tested after 24 hr, and the remaining half after 3 years of water storage. µTBS data were analyzed using a three-way analysis of variance, Tukey’s test, and Dunnett’s test. Results. The lowest µTBS values were observed when the restoration was performed immediately after bleaching in the AV, GS, and WA groups when compared with the SA group ( ). However, no significant differences were observed among all groups after 3 years of water storage ( ). Conclusions. SA at 10% was the most effective antioxidant agent for improving the immediate bond strength. However, independent of the antioxidant agent used, the bond strength values were maintained or recovered after 3 years of water storage. SA at 10% could be used to avoid delayed bonding procedures after in-office whitening without compromising bond strength over time. Clinical Significance. The use of antioxidants after dental bleaching can be effective in improving the bonding durability of the adhesive restorations.
- Open Access
- 1 October 2023
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 34 (5) , 87-94
Effects of the application of sodium ascorbate after in-office bleaching on the penetration of hydrogen peroxide, color change, and microtensile bond strength
This study aimed to evaluate the effects of the application of 10% sodium ascorbate (SA) after in-office bleaching on the penetration of hydrogen peroxide (HP) into the pulp chamber, color change, and microtensile bond strength (µTBS) to the resin-enamel interface. Thirty premolars and thirty molars were randomly divided into three groups (n = 20 each). One group was exposed to deionized water (negative control). The other two groups were bleached with 35% HP in a single session for 3x15 minutes for each application. However, in only one of them, SA was applied for 10 minutes after bleaching. After, the concentration (µg/mL) of HP in each pulp chamber was evaluated by UV-Vis spectrophotometry. Color changes (ΔEab, ΔE00, and ΔWID) were evaluated with a digital spectrophotometer before and in the first week after bleaching. After treatment, molars were restored and sectioned to obtain resin-enamel interface sticks for µTBS at a crosshead speed of 1 mm/min until failure. The HP concentration and µTBS data were analyzed using one-way ANOVA and Tukey tests, and color changes were analyzed by t-tests (α = 0.05). SA application significantly improved the µTBS values and reduced the HP concentrations within the pulp chambers (p < 0.0001). The application of SA significantly interfered with the color changes after bleaching when compared to the control group (p < 0.05). Application of 10% SA after in-office bleaching successfully reduced the penetration of HP into the pulp chamber; however, it decreased color change.
- 1 October 2023
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 34 (5) , 87-94
Open AccessEffects of the application of sodium ascorbate after in-office bleaching on the penetration of hydrogen peroxide, color change, and microtensile bond strength
This study aimed to evaluate the effects of the application of 10% sodium ascorbate (SA) after in-office bleaching on the penetration of hydrogen peroxide (HP) into the pulp chamber, color change, and microtensile bond strength (µTBS) to the resin-enamel interface. Thirty premolars and thirty molars were randomly divided into three groups (n = 20 each). One group was exposed to deionized water (negative control). The other two groups were bleached with 35% HP in a single session for 3x15 minutes for each application. However, in only one of them, SA was applied for 10 minutes after bleaching. After, the concentration (µg/mL) of HP in each pulp chamber was evaluated by UV-Vis spectrophotometry. Color changes (ΔEab, ΔE00, and ΔWID) were evaluated with a digital spectrophotometer before and in the first week after bleaching. After treatment, molars were restored and sectioned to obtain resin-enamel interface sticks for µTBS at a crosshead speed of 1 mm/min until failure. The HP concentration and µTBS data were analyzed using one-way ANOVA and Tukey tests, and color changes were analyzed by t-tests (α = 0.05). SA application significantly improved the µTBS values and reduced the HP concentrations within the pulp chambers (p < 0.0001). The application of SA significantly interfered with the color changes after bleaching when compared to the control group (p < 0.05). Application of 10% SA after in-office bleaching successfully reduced the penetration of HP into the pulp chamber; however, it decreased color change.
- 8 September 2023
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 36 (2) , 402-409
In vitro evaluation of the effect of different bleaching varnishes: Hydrogen peroxide penetration into the pulp chamber and color change
Objective: To evaluate the penetration of hydrogen peroxide (HP) into the pulp chamber and the color change of different bleaching varnishes in low concentrations used for at‐home bleaching.Materials and Methods: Ninety healthy premolars were used, randomly distributed into nine groups (n = 10) according to bleaching varnish (PL, PolaLuminate; VS, VivaStyle Paint On Plus; CA, Cavex Bite&White whitening pen and; AW AlignerWhite) and time (10 and 30 min), and a control group (no bleaching). The penetration of HP was evaluated by UV–Vis spectroscopy. To evaluate the color change (ΔEab, ΔE00, ΔWID) a digital spectrophotometer was used (α = 0.05).Results: The AW group in 10 min and the control group showed similar and lower HP penetration in the pulp chamber when compared to the other groups (p = 0.003). Increasing the application time to 30 minutes elevated the amount of HP inside the pulp chamber for all groups (p = 0.003), except for PL (p > 0.05). When applied for 30 min all bleaching varnishes showed higher color change (ΔWID) when compared to 10 min (p = 0.04).Conclusions: For all bleaching varnishes evaluated, PolaLuminate applied for 30 min showed lower penetration into the pulp chamber and higher bleaching effects.Clinical Significance: The use of bleaching varnishes seems promising for teeth bleaching, but it varies according to user product and protocol.
- 8 September 2023
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 36 (2) , 402-409
In vitro evaluation of the effect of different bleaching varnishes: Hydrogen peroxide penetration into the pulp chamber and color change
Objective: To evaluate the penetration of hydrogen peroxide (HP) into the pulp chamber and the color change of different bleaching varnishes in low concentrations used for at‐home bleaching.Materials and Methods: Ninety healthy premolars were used, randomly distributed into nine groups (n = 10) according to bleaching varnish (PL, PolaLuminate; VS, VivaStyle Paint On Plus; CA, Cavex Bite&White whitening pen and; AW AlignerWhite) and time (10 and 30 min), and a control group (no bleaching). The penetration of HP was evaluated by UV–Vis spectroscopy. To evaluate the color change (ΔEab, ΔE00, ΔWID) a digital spectrophotometer was used (α = 0.05).Results: The AW group in 10 min and the control group showed similar and lower HP penetration in the pulp chamber when compared to the other groups (p = 0.003). Increasing the application time to 30 minutes elevated the amount of HP inside the pulp chamber for all groups (p = 0.003), except for PL (p > 0.05). When applied for 30 min all bleaching varnishes showed higher color change (ΔWID) when compared to 10 min (p = 0.04).Conclusions: For all bleaching varnishes evaluated, PolaLuminate applied for 30 min showed lower penetration into the pulp chamber and higher bleaching effects.Clinical Significance: The use of bleaching varnishes seems promising for teeth bleaching, but it varies according to user product and protocol.
- Open Access
- 12 October 2022
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 17 (03) , 615-622
Occlusal Analysis in Natural Dentition: Systematic Review
This study aimed to evaluate the effectiveness of conventional occlusal analysis in contrast with digital occlusal analysis in natural dentition. Occlusal analysis allows the identification of normal and abnormal occlusal contact points that alter the craniomandibular cervical system. We searched for articles with keywords [[dental occlusion]], [[natural dentition]], [[occlusal adjustment]], [[Immediate Complete Anterior Guidance Development]] [[mastication]], [[bite force]], [[premature contact]], [[occlusal balance]] [[articulating paper]]], [[spray]], [[Occlusal contacts]], and [[bite strength]]. They were considered observational , odds ratio and case control studies. We found 189 items. After evaluating the abstracts and full texts of the articles, 10 papers met the inclusion criteria. It was found that occlusal analysis allows the identification of the relationship between poor occlusion and the sensitivity of the teeth due to occlusal trauma, which is also related to temporomandibular joint pain in dynamic occlusion. The contacts of greater strength were observed in nonfunctional cusps, 48%, without ruling out the functional cusps, 24%. Despite being the universal method of occlusal control to date, the use of joint paper, remains subjective compared to the digital occlusal control device. Posture is considered directly related to occlusal trauma and temporomandibular disorders; without proper occlusal analysis, a clear diagnosis of the patient's joint condition cannot be obtained. Digital occlusal analysis is more objective than traditional occlusal analysis.
- 12 October 2022
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 17 (03) , 615-622
Open AccessOcclusal Analysis in Natural Dentition: Systematic Review
This study aimed to evaluate the effectiveness of conventional occlusal analysis in contrast with digital occlusal analysis in natural dentition. Occlusal analysis allows the identification of normal and abnormal occlusal contact points that alter the craniomandibular cervical system. We searched for articles with keywords [[dental occlusion]], [[natural dentition]], [[occlusal adjustment]], [[Immediate Complete Anterior Guidance Development]] [[mastication]], [[bite force]], [[premature contact]], [[occlusal balance]] [[articulating paper]]], [[spray]], [[Occlusal contacts]], and [[bite strength]]. They were considered observational , odds ratio and case control studies. We found 189 items. After evaluating the abstracts and full texts of the articles, 10 papers met the inclusion criteria. It was found that occlusal analysis allows the identification of the relationship between poor occlusion and the sensitivity of the teeth due to occlusal trauma, which is also related to temporomandibular joint pain in dynamic occlusion. The contacts of greater strength were observed in nonfunctional cusps, 48%, without ruling out the functional cusps, 24%. Despite being the universal method of occlusal control to date, the use of joint paper, remains subjective compared to the digital occlusal control device. Posture is considered directly related to occlusal trauma and temporomandibular disorders; without proper occlusal analysis, a clear diagnosis of the patient's joint condition cannot be obtained. Digital occlusal analysis is more objective than traditional occlusal analysis.
- 4 February 2016
- Published by Editora Napoleao Ltda ME in THE INTERNATIONAL JOURNAL OF ESTHETIC DENTISTRY
- Vol. 01 (01)
Ensaio clínico randomizado sobre quatro estratégias adesivas em lesões cervicais: resultados de 12 meses
- 4 February 2016
- Published by Editora Napoleao Ltda ME in THE INTERNATIONAL JOURNAL OF ESTHETIC DENTISTRY
- Vol. 01 (01)
Ensaio clínico randomizado sobre quatro estratégias adesivas em lesões cervicais: resultados de 12 meses
- 1 December 2014
- Vol. 27 (6) , 301-6
Penetration and cytotoxicity of a bleaching gel activated by LED/laser in restored teeth.
To evaluate the amount of hydrogen peroxide (HP) in the pulp chamber of teeth restored with composite resin and its cytotoxic effect on fibroblast cell line 3T3/NIH. 112 human premolars were randomized into groups according to the combination of factors: Restoration: no restoration (NR); shallow (S); deep (D) and Activation by Light: yes (A) or no (NA). With exception of the groups Control and NR, Class V cavities (3 mm x 2 mm x 1 mm [S] and 3 mm x 2 mm x 2 mm [D]) were prepared and restored with composite resin. An acetate buffer was placed in the pulp chamber. The bleaching procedure was performed with 35% HP and activated or not with a LED/laser light. The buffer was mixed with leucocrystal violet and peroxide enzyme for the spectrophotometric evaluation of the optical density of the solution. For viability cell assays, different concentrations of HP were applied to fibroblast cell line. After 24 hours, the MTT and neutral red assays were evaluated. The lethal concentration of 50% of cells (LC50) was determined. Data were submitted to ANOVA and Tukey's test (α = 0.05). All experimental groups showed HP in the pulp chamber, but a higher amount was found in the pulp chamber of teeth with deep restorations (P = 0.026), regardless of light activation. The concentrations of HP that were found in the pulp chamber did not affect cell viability.
- 1 December 2014
- Vol. 27 (6) , 301-6
Penetration and cytotoxicity of a bleaching gel activated by LED/laser in restored teeth.
To evaluate the amount of hydrogen peroxide (HP) in the pulp chamber of teeth restored with composite resin and its cytotoxic effect on fibroblast cell line 3T3/NIH. 112 human premolars were randomized into groups according to the combination of factors: Restoration: no restoration (NR); shallow (S); deep (D) and Activation by Light: yes (A) or no (NA). With exception of the groups Control and NR, Class V cavities (3 mm x 2 mm x 1 mm [S] and 3 mm x 2 mm x 2 mm [D]) were prepared and restored with composite resin. An acetate buffer was placed in the pulp chamber. The bleaching procedure was performed with 35% HP and activated or not with a LED/laser light. The buffer was mixed with leucocrystal violet and peroxide enzyme for the spectrophotometric evaluation of the optical density of the solution. For viability cell assays, different concentrations of HP were applied to fibroblast cell line. After 24 hours, the MTT and neutral red assays were evaluated. The lethal concentration of 50% of cells (LC50) was determined. Data were submitted to ANOVA and Tukey's test (α = 0.05). All experimental groups showed HP in the pulp chamber, but a higher amount was found in the pulp chamber of teeth with deep restorations (P = 0.026), regardless of light activation. The concentrations of HP that were found in the pulp chamber did not affect cell viability.
- 1 October 2014
- Vol. 16 (5) , 435-440
Effect of Sonic Application Mode on the Resin-Dentin Bond Strength and Dentin Permeability of Self-etching Systems
To compare manual and sonic adhesive application modes in terms of the permeability and microtensile bond strength of a self-etching adhesive applied in the one-step or two-step protocol. Self-etching All Bond SE (Bisco) was applied as a one- or a two-step adhesive under manual or sonic vibration modes on flat occlusal dentin surfaces of 64 human molars. Half of the teeth were used to measure the hydraulic conductance of dentin at 200 cm H₂O hydrostatic pressure for 5 min immediately after the adhesive application. In the other half, composite buildups (Opallis) were constructed incrementally to create resin-dentin sticks with a cross-sectional area of 0.8 mm² to be tested in tension (0.5 mm/min) immediately after restoration placement. Data were analyzed using a two-way ANOVA and Tukey's test (α = 0.05). The fluid conductance of dentin was significantly reduced by the sonic vibration mode for both adhesives, but no effect on the bond strength values was observed for either adhesive. The sonic application mode at an oscillating frequency of 170 Hz can reduce the fluid conductance of the one- and two-step All Bond SE adhesive when applied on dentin.
- 1 October 2014
- Vol. 16 (5) , 435-440
Effect of Sonic Application Mode on the Resin-Dentin Bond Strength and Dentin Permeability of Self-etching Systems
To compare manual and sonic adhesive application modes in terms of the permeability and microtensile bond strength of a self-etching adhesive applied in the one-step or two-step protocol. Self-etching All Bond SE (Bisco) was applied as a one- or a two-step adhesive under manual or sonic vibration modes on flat occlusal dentin surfaces of 64 human molars. Half of the teeth were used to measure the hydraulic conductance of dentin at 200 cm H₂O hydrostatic pressure for 5 min immediately after the adhesive application. In the other half, composite buildups (Opallis) were constructed incrementally to create resin-dentin sticks with a cross-sectional area of 0.8 mm² to be tested in tension (0.5 mm/min) immediately after restoration placement. Data were analyzed using a two-way ANOVA and Tukey's test (α = 0.05). The fluid conductance of dentin was significantly reduced by the sonic vibration mode for both adhesives, but no effect on the bond strength values was observed for either adhesive. The sonic application mode at an oscillating frequency of 170 Hz can reduce the fluid conductance of the one- and two-step All Bond SE adhesive when applied on dentin.
- 28 June 2013
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 18 (3) , 729-736
Effect of sonic application mode on the resin–dentin bond strength and nanoleakage of simplified self-etch adhesive
This study aims to evaluate the effect of different application modes on the immediate and 6-month resin–dentin bond strength (μTBS) and nanoleakage in the hybrid and adhesive layers. Three 1-step self-etch adhesives (One Coat 7.0 (OC), Clearfil S3 Bond (CS), and FuturaBond NR (FB)) were applied on a flat superficial dentin surface of 30 human molars under manual mode or sonic vibration at a frequency of 170 Hz (SV). Composite build-ups were constructed incrementally; specimens were sectioned to obtain resin–dentin sticks with cross-sectional area of 0.8 mm2 and tested in tension (0.5 mm/min) immediately (IM) or after 6 months (6M) of water storage. Two bonded sticks, from each tooth at each storage time, were immersed in a silver nitrate solution, photo-developed, and analyzed under scanning electron microscopy. The amount of nanoleakage was measured using the ImageTool 3.0 software. Data, from each adhesive, were analyzed by two-way ANOVA and Tukey’s test (α = 0.05). OC and CS showed higher μTBS and lower nanoleakage in the IM period when applied with SV groups. For FB, no significant difference was observed between the two modes of application. All materials showed lower nanoleakage in the SV groups. Higher nanoleakage was observed after 6M for OC and FB. The sonic application mode at an oscillating frequency of 170 Hz can improve the resin–dentin μTBS, reduce the nanoleakage, and retard the degradation of the resin–dentin μTBS of Clearfil S3 Bond and One Coat 7.0 adhesives. Sonic application mode at an oscillating frequency of 170 Hz can be helpful and easy to use in dental practice to guaranty long-lasting restorations.
- 28 June 2013
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 18 (3) , 729-736
Effect of sonic application mode on the resin–dentin bond strength and nanoleakage of simplified self-etch adhesive
This study aims to evaluate the effect of different application modes on the immediate and 6-month resin–dentin bond strength (μTBS) and nanoleakage in the hybrid and adhesive layers. Three 1-step self-etch adhesives (One Coat 7.0 (OC), Clearfil S3 Bond (CS), and FuturaBond NR (FB)) were applied on a flat superficial dentin surface of 30 human molars under manual mode or sonic vibration at a frequency of 170 Hz (SV). Composite build-ups were constructed incrementally; specimens were sectioned to obtain resin–dentin sticks with cross-sectional area of 0.8 mm2 and tested in tension (0.5 mm/min) immediately (IM) or after 6 months (6M) of water storage. Two bonded sticks, from each tooth at each storage time, were immersed in a silver nitrate solution, photo-developed, and analyzed under scanning electron microscopy. The amount of nanoleakage was measured using the ImageTool 3.0 software. Data, from each adhesive, were analyzed by two-way ANOVA and Tukey’s test (α = 0.05). OC and CS showed higher μTBS and lower nanoleakage in the IM period when applied with SV groups. For FB, no significant difference was observed between the two modes of application. All materials showed lower nanoleakage in the SV groups. Higher nanoleakage was observed after 6M for OC and FB. The sonic application mode at an oscillating frequency of 170 Hz can improve the resin–dentin μTBS, reduce the nanoleakage, and retard the degradation of the resin–dentin μTBS of Clearfil S3 Bond and One Coat 7.0 adhesives. Sonic application mode at an oscillating frequency of 170 Hz can be helpful and easy to use in dental practice to guaranty long-lasting restorations.