Jungwoo Huh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jungwoo Huh has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Jihye Heo
Department of Oral & Maxillofacial Surgery, Korea University Anam Hospital, Seoul 02841, Republic of Korea
12 shared publications - Seongpil An
SKKU Advanced Institute of Nanotechnology (SAINT), Sungkyunkwan University (SKKU), Suwon, Republic of Korea
12 shared publications - Yong Il Kim
SKKU Advanced Institute of Nanotechnology (SAINT), Sungkyunkwan University, Suwon 16419, Republic of Korea
12 shared publications - Yang-Soo Kim
Dunamis Dental Co. Ltd, 904, A-Dong, Gwangmyeong Technopark, Haan-Ro 60, Gwangmyeong-Si, Gyeonggi-Do 14322, South Korea
9 shared publications - Sam Sukgoo Yoon
School of Mechanical Engineering, Korea University, Seoul 02841, Republic of Korea
7 shared publications - Alexander L. Yarin
Department of Mechanical and Industrial Engineering, University of Illinois Chicago, 842 W. Taylor St., Chicago, Illinois 60607-7022, United States
6 shared publications
Latest Publications
- 1 September 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (9)
Suppression of aerosol dispersion by highly viscoelastic poly(acrylic acid)- and poly(ethylene oxide)-based coolants during bone drilling
Bone drilling in neurosurgical, dental, and orthopedic procedures, combined with the use of coolants, generates a dispersion of bone particles, coolants, and blood aerosols in the air. This poses the threat of airborne transmission of infectious diseases between patients and medical practitioners. Highly viscoelastic polymeric poly(acrylic acid) (PAA) and poly(ethylene oxide) (PEO) solutions of various concentrations were used as coolants during bone drilling at different mass flow rates to suppress aerosol generation, thereby mitigating the threat of cross-infection. The results revealed that the PAA and PEO solutions provide less advection than water and a comparable cooling performance. However, excessive viscoelasticity of PEO causes the fluid to rise along the cutting burr (the Weissenberg effect), thereby reducing the cooling coverage area. In contrast, slightly lower viscoelasticity of PEO results in a high cooling coverage area. The cooling coverage area is smaller for the PAA at 20 ml/min because the corresponding PAA solution easily swirls or splashes away from the drilling location. However, at 80 ml/min, the supplied PAA solution sufficiently cools the drilling area, despite the loss through splashing. The numbers of atomized droplets of water and the PAA and PEO solutions were quantified and compared to investigate the degree of aerosol formation and dispersion. The solution with the strongest viscoelasticity most significantly suppressed aerosolization and produced the fewest dispersed aerosol droplets during bone drilling.
- 1 September 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (9)
Suppression of aerosol dispersion by highly viscoelastic poly(acrylic acid)- and poly(ethylene oxide)-based coolants during bone drilling
Bone drilling in neurosurgical, dental, and orthopedic procedures, combined with the use of coolants, generates a dispersion of bone particles, coolants, and blood aerosols in the air. This poses the threat of airborne transmission of infectious diseases between patients and medical practitioners. Highly viscoelastic polymeric poly(acrylic acid) (PAA) and poly(ethylene oxide) (PEO) solutions of various concentrations were used as coolants during bone drilling at different mass flow rates to suppress aerosol generation, thereby mitigating the threat of cross-infection. The results revealed that the PAA and PEO solutions provide less advection than water and a comparable cooling performance. However, excessive viscoelasticity of PEO causes the fluid to rise along the cutting burr (the Weissenberg effect), thereby reducing the cooling coverage area. In contrast, slightly lower viscoelasticity of PEO results in a high cooling coverage area. The cooling coverage area is smaller for the PAA at 20 ml/min because the corresponding PAA solution easily swirls or splashes away from the drilling location. However, at 80 ml/min, the supplied PAA solution sufficiently cools the drilling area, despite the loss through splashing. The numbers of atomized droplets of water and the PAA and PEO solutions were quantified and compared to investigate the degree of aerosol formation and dispersion. The solution with the strongest viscoelasticity most significantly suppressed aerosolization and produced the fewest dispersed aerosol droplets during bone drilling.
- 6 January 2024
- Published by Elsevier in Chemical Engineering Journal
- Vol. 481, 148617
Uniformly distributed FeVO4 nanocuboids on exfoliated rGO facilitated by supersonic spraying for wearable supercapacitors
- 6 January 2024
- Published by Elsevier in Chemical Engineering Journal
- Vol. 481, 148617
Uniformly distributed FeVO4 nanocuboids on exfoliated rGO facilitated by supersonic spraying for wearable supercapacitors
- 1 January 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (1)
Effect of muzzle gases on forward spatter of viscoelastic blood in close-range shooting
Because bloodstain patterns resulting from close-range shooting are intrinsically different from those of long-range shooting, an accurate interpretation and delineation of these phenomena are essential in forensic science and crime scene analysis. Such a delineation would be helpful, for example, to distinguish whether a suicide or a homicide had happened. If the shooting was from a long-range (most likely a homicide), muzzle gases would not be able to influence blood spatter ejected from a victim. However, in the case of a close-range shooting, muzzle gases would greatly influence blood spatter. Herein, the effect of the muzzle gases on bloodstain patterns is studied. A de Laval nozzle is used to mimic an issue of supersonic “muzzle” gas from a gun barrel. The supersonic gas flow passes through a cylinder containing defibrinated sheep blood, which is blown off and atomized into numerous drops. These drops fly away and settle onto the floor or onto vertical walls at various distances from the cylinder exit. Viscoelasticity of the defibrinated sheep blood is enhanced by adding Xanthan to model different states of blood corresponding to different conditions. An impact of a vertically-released single drop onto an inclined substrate was also studied to elucidate splashing regimes/criteria of the blood drops of different viscoelasticity levels. We found that stronger elastic forces facilitated formation of bloodstains with higher ellipticity at a higher impact angles.
- 1 January 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (1)
Effect of muzzle gases on forward spatter of viscoelastic blood in close-range shooting
Because bloodstain patterns resulting from close-range shooting are intrinsically different from those of long-range shooting, an accurate interpretation and delineation of these phenomena are essential in forensic science and crime scene analysis. Such a delineation would be helpful, for example, to distinguish whether a suicide or a homicide had happened. If the shooting was from a long-range (most likely a homicide), muzzle gases would not be able to influence blood spatter ejected from a victim. However, in the case of a close-range shooting, muzzle gases would greatly influence blood spatter. Herein, the effect of the muzzle gases on bloodstain patterns is studied. A de Laval nozzle is used to mimic an issue of supersonic “muzzle” gas from a gun barrel. The supersonic gas flow passes through a cylinder containing defibrinated sheep blood, which is blown off and atomized into numerous drops. These drops fly away and settle onto the floor or onto vertical walls at various distances from the cylinder exit. Viscoelasticity of the defibrinated sheep blood is enhanced by adding Xanthan to model different states of blood corresponding to different conditions. An impact of a vertically-released single drop onto an inclined substrate was also studied to elucidate splashing regimes/criteria of the blood drops of different viscoelasticity levels. We found that stronger elastic forces facilitated formation of bloodstains with higher ellipticity at a higher impact angles.
- Open Access
- 1 September 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (9)
Effect of muzzle gas on forward blood spatter from a gunshot: Experiments with a supersonic de Laval nozzle
For bloodstain pattern analysis (BPA), interpreting statistically reliable data on a crime scene resulting from gunshots is a great challenge. This is due to various uncertainties, including blood rheology, hematocrit, coagulation, surrounding atmospheric conditions, victim's peculiarities, gun types, geometries, etc. In addition, muzzle (propellant) gases that follow the bullet may influence the aerodynamics of blood spatter in the cases of short-range shooting. We studied the muzzle gas effect on forward blood spatter. Muzzle gas can penetrate the wound channel and be ejected from the bullet exit hole affecting the forward blood spatter. Experiments with blood atomization by a gas flow issued from a supersonic de Laval converging–diverging nozzle are conducted. Defibrinated sheep blood was enclosed in a thin solid cylinder, which was filled by a supersonic air flow ejected from a de Laval nozzle, mimicking the muzzle gas flow through a wound channel. The mass flow rate of the supersonic air stream was varied by controlling the upstream chamber pressure. It was found that the number counts of the forward blood spatter from the muzzle gas blasting peaked at relatively shorter distances from the exit hole compared to the one that would be caused by a bullet. The effects of the muzzle gas and bullet could cause the formation of a bimodal spatter distribution on the floor behind the exit hole. These findings imply that atomization events owing to muzzle gas cause coarser atomization than that of a bullet, which could facilitate BPA in distinguishing certain homicides from staged suicides.
- 1 September 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (9)
Open AccessEffect of muzzle gas on forward blood spatter from a gunshot: Experiments with a supersonic de Laval nozzle
For bloodstain pattern analysis (BPA), interpreting statistically reliable data on a crime scene resulting from gunshots is a great challenge. This is due to various uncertainties, including blood rheology, hematocrit, coagulation, surrounding atmospheric conditions, victim's peculiarities, gun types, geometries, etc. In addition, muzzle (propellant) gases that follow the bullet may influence the aerodynamics of blood spatter in the cases of short-range shooting. We studied the muzzle gas effect on forward blood spatter. Muzzle gas can penetrate the wound channel and be ejected from the bullet exit hole affecting the forward blood spatter. Experiments with blood atomization by a gas flow issued from a supersonic de Laval converging–diverging nozzle are conducted. Defibrinated sheep blood was enclosed in a thin solid cylinder, which was filled by a supersonic air flow ejected from a de Laval nozzle, mimicking the muzzle gas flow through a wound channel. The mass flow rate of the supersonic air stream was varied by controlling the upstream chamber pressure. It was found that the number counts of the forward blood spatter from the muzzle gas blasting peaked at relatively shorter distances from the exit hole compared to the one that would be caused by a bullet. The effects of the muzzle gas and bullet could cause the formation of a bimodal spatter distribution on the floor behind the exit hole. These findings imply that atomization events owing to muzzle gas cause coarser atomization than that of a bullet, which could facilitate BPA in distinguishing certain homicides from staged suicides.
- 1 April 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (4) , 049903
Publisher’s Note: “Effect of polymer viscosity and viscoelasticity on tooth cooling and aerosolization during dental procedures” [Phys. Fluids 35, 023112 (2023)]
- 1 April 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (4) , 049903
Publisher’s Note: “Effect of polymer viscosity and viscoelasticity on tooth cooling and aerosolization during dental procedures” [Phys. Fluids 35, 023112 (2023)]
- 28 February 2023
- Published by AIP Publishing
- Vol. 35 (2) , 023112
10.1063/5.0136286.1
Cooling liquids used in ultrasonic scalers are aerosolized into droplets. Larger droplets splatter over dental practitioners and patients, and small aerosols become airborne, posing a health threat to people in the surrounding area if a patient is infected by viral or bacterial infections. Polyacrylic acid (PAA), polyethylene glycol (PEG), and polyvinylpyrrolidone (PVP) can efficiently cool teeth and suppress aerosolization owing to their rheological properties, with PAA being the superior viscoelastic suppressant. Although the solutions of PEG and PVP studied here are also efficient in suppressing aerosol formation, their high viscosity may hinder their supply to the dental tools because of high viscous dissipation. The rheological behavior of PAA, PEG, and PVP is studied in the uniaxial elongational flow in self-thinning capillary threads. Then, the behavior of these solutions in an ultrasonic scaler in dental practice is explored. In particular, the aerosolization phenomena and the corresponding aerosol size distributions and droplet trajectories are studied and compared. The tooth temperature is found to be similar to that of water when these polymer solutions are used. The dispersion of the aerosolized droplets is qualitatively demonstrated by performing scaling using model teeth on a phantom mannequin face.
- 28 February 2023
- Published by AIP Publishing
- Vol. 35 (2) , 023112
10.1063/5.0136286.1
Cooling liquids used in ultrasonic scalers are aerosolized into droplets. Larger droplets splatter over dental practitioners and patients, and small aerosols become airborne, posing a health threat to people in the surrounding area if a patient is infected by viral or bacterial infections. Polyacrylic acid (PAA), polyethylene glycol (PEG), and polyvinylpyrrolidone (PVP) can efficiently cool teeth and suppress aerosolization owing to their rheological properties, with PAA being the superior viscoelastic suppressant. Although the solutions of PEG and PVP studied here are also efficient in suppressing aerosol formation, their high viscosity may hinder their supply to the dental tools because of high viscous dissipation. The rheological behavior of PAA, PEG, and PVP is studied in the uniaxial elongational flow in self-thinning capillary threads. Then, the behavior of these solutions in an ultrasonic scaler in dental practice is explored. In particular, the aerosolization phenomena and the corresponding aerosol size distributions and droplet trajectories are studied and compared. The tooth temperature is found to be similar to that of water when these polymer solutions are used. The dispersion of the aerosolized droplets is qualitatively demonstrated by performing scaling using model teeth on a phantom mannequin face.
- 1 February 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (2) , 023112
Effect of polymer viscosity and viscoelasticity on tooth cooling and aerosolization during dental procedures
Cooling liquids used in ultrasonic scalers are aerosolized into droplets. Larger droplets splatter over dental practitioners and patients, and small aerosols become airborne, posing a health threat to people in the surrounding area if a patient is infected by viral or bacterial infections. Polyacrylic acid (PAA), polyethylene glycol (PEG), and polyvinylpyrrolidone (PVP) can efficiently cool teeth and suppress aerosolization owing to their rheological properties, with PAA being the superior viscoelastic suppressant. Although the solutions of PEG and PVP studied here are also efficient in suppressing aerosol formation, their high viscosity may hinder their supply to the dental tools because of high viscous dissipation. The rheological behavior of PAA, PEG, and PVP is studied in the uniaxial elongational flow in self-thinning capillary threads. Then, the behavior of these solutions in an ultrasonic scaler in dental practice is explored. In particular, the aerosolization phenomena and the corresponding aerosol size distributions and droplet trajectories are studied and compared. The tooth temperature is found to be similar to that of water when these polymer solutions are used. The dispersion of the aerosolized droplets is qualitatively demonstrated by performing scaling using model teeth on a phantom mannequin face.
- 1 February 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (2) , 023112
Effect of polymer viscosity and viscoelasticity on tooth cooling and aerosolization during dental procedures
Cooling liquids used in ultrasonic scalers are aerosolized into droplets. Larger droplets splatter over dental practitioners and patients, and small aerosols become airborne, posing a health threat to people in the surrounding area if a patient is infected by viral or bacterial infections. Polyacrylic acid (PAA), polyethylene glycol (PEG), and polyvinylpyrrolidone (PVP) can efficiently cool teeth and suppress aerosolization owing to their rheological properties, with PAA being the superior viscoelastic suppressant. Although the solutions of PEG and PVP studied here are also efficient in suppressing aerosol formation, their high viscosity may hinder their supply to the dental tools because of high viscous dissipation. The rheological behavior of PAA, PEG, and PVP is studied in the uniaxial elongational flow in self-thinning capillary threads. Then, the behavior of these solutions in an ultrasonic scaler in dental practice is explored. In particular, the aerosolization phenomena and the corresponding aerosol size distributions and droplet trajectories are studied and compared. The tooth temperature is found to be similar to that of water when these polymer solutions are used. The dispersion of the aerosolized droplets is qualitatively demonstrated by performing scaling using model teeth on a phantom mannequin face.
- 18 October 2022
- Published by AIP Publishing
- Vol. 34 (10) , 103108
10.1063/5.0112210.8
Aerosolized droplets are produced en masse in dental practices; these aerosols disperse in the surrounding space, posing a health threat if the patient is infected with a transmittable disease, particularly COVID-19. Here, a viscoelastic polyacrylic acid (PAA) solution was used to minimize liquid aerosolization and limit the travel distance of aerosols. The PAA concentration was varied to evaluate its effect on aerosolization and droplet size resulting from procedures using dental handpieces, which include tooth cutting, grinding, and polishing. In addition, a thermocouple was inserted at the center of the model tooth to measure its temperature during a handpiece operation. The temperature data suggest that the cooling performance of the PAA solution is comparable to that of pure water in operations in the occlusal and facial directions. The PAA solution droplets splattered on the patient's facial area during the handpiece operation are markedly larger than those of pure water, which is evidence of the settling of the PAA droplets, preventing further transmission. Accordingly, the travel distance of the aerosolized PAA droplets was limited by viscoelastic resistance to droplet detachment. This comparison of the aerosol suppression capability between water and PAA solutions confirms the benefit of using viscoelastic solutions for various dental operations.
- 18 October 2022
- Published by AIP Publishing
- Vol. 34 (10) , 103108
10.1063/5.0112210.8
Aerosolized droplets are produced en masse in dental practices; these aerosols disperse in the surrounding space, posing a health threat if the patient is infected with a transmittable disease, particularly COVID-19. Here, a viscoelastic polyacrylic acid (PAA) solution was used to minimize liquid aerosolization and limit the travel distance of aerosols. The PAA concentration was varied to evaluate its effect on aerosolization and droplet size resulting from procedures using dental handpieces, which include tooth cutting, grinding, and polishing. In addition, a thermocouple was inserted at the center of the model tooth to measure its temperature during a handpiece operation. The temperature data suggest that the cooling performance of the PAA solution is comparable to that of pure water in operations in the occlusal and facial directions. The PAA solution droplets splattered on the patient's facial area during the handpiece operation are markedly larger than those of pure water, which is evidence of the settling of the PAA droplets, preventing further transmission. Accordingly, the travel distance of the aerosolized PAA droplets was limited by viscoelastic resistance to droplet detachment. This comparison of the aerosol suppression capability between water and PAA solutions confirms the benefit of using viscoelastic solutions for various dental operations.
- 18 October 2022
- Published by AIP Publishing
- Vol. 34 (10) , 103108
10.1063/5.0112210.1
Aerosolized droplets are produced en masse in dental practices; these aerosols disperse in the surrounding space, posing a health threat if the patient is infected with a transmittable disease, particularly COVID-19. Here, a viscoelastic polyacrylic acid (PAA) solution was used to minimize liquid aerosolization and limit the travel distance of aerosols. The PAA concentration was varied to evaluate its effect on aerosolization and droplet size resulting from procedures using dental handpieces, which include tooth cutting, grinding, and polishing. In addition, a thermocouple was inserted at the center of the model tooth to measure its temperature during a handpiece operation. The temperature data suggest that the cooling performance of the PAA solution is comparable to that of pure water in operations in the occlusal and facial directions. The PAA solution droplets splattered on the patient's facial area during the handpiece operation are markedly larger than those of pure water, which is evidence of the settling of the PAA droplets, preventing further transmission. Accordingly, the travel distance of the aerosolized PAA droplets was limited by viscoelastic resistance to droplet detachment. This comparison of the aerosol suppression capability between water and PAA solutions confirms the benefit of using viscoelastic solutions for various dental operations.
- 18 October 2022
- Published by AIP Publishing
- Vol. 34 (10) , 103108
10.1063/5.0112210.1
Aerosolized droplets are produced en masse in dental practices; these aerosols disperse in the surrounding space, posing a health threat if the patient is infected with a transmittable disease, particularly COVID-19. Here, a viscoelastic polyacrylic acid (PAA) solution was used to minimize liquid aerosolization and limit the travel distance of aerosols. The PAA concentration was varied to evaluate its effect on aerosolization and droplet size resulting from procedures using dental handpieces, which include tooth cutting, grinding, and polishing. In addition, a thermocouple was inserted at the center of the model tooth to measure its temperature during a handpiece operation. The temperature data suggest that the cooling performance of the PAA solution is comparable to that of pure water in operations in the occlusal and facial directions. The PAA solution droplets splattered on the patient's facial area during the handpiece operation are markedly larger than those of pure water, which is evidence of the settling of the PAA droplets, preventing further transmission. Accordingly, the travel distance of the aerosolized PAA droplets was limited by viscoelastic resistance to droplet detachment. This comparison of the aerosol suppression capability between water and PAA solutions confirms the benefit of using viscoelastic solutions for various dental operations.
- 18 October 2022
- Published by AIP Publishing
- Vol. 34 (10) , 103108
10.1063/5.0112210.3
Aerosolized droplets are produced en masse in dental practices; these aerosols disperse in the surrounding space, posing a health threat if the patient is infected with a transmittable disease, particularly COVID-19. Here, a viscoelastic polyacrylic acid (PAA) solution was used to minimize liquid aerosolization and limit the travel distance of aerosols. The PAA concentration was varied to evaluate its effect on aerosolization and droplet size resulting from procedures using dental handpieces, which include tooth cutting, grinding, and polishing. In addition, a thermocouple was inserted at the center of the model tooth to measure its temperature during a handpiece operation. The temperature data suggest that the cooling performance of the PAA solution is comparable to that of pure water in operations in the occlusal and facial directions. The PAA solution droplets splattered on the patient's facial area during the handpiece operation are markedly larger than those of pure water, which is evidence of the settling of the PAA droplets, preventing further transmission. Accordingly, the travel distance of the aerosolized PAA droplets was limited by viscoelastic resistance to droplet detachment. This comparison of the aerosol suppression capability between water and PAA solutions confirms the benefit of using viscoelastic solutions for various dental operations.
- 18 October 2022
- Published by AIP Publishing
- Vol. 34 (10) , 103108
10.1063/5.0112210.3
Aerosolized droplets are produced en masse in dental practices; these aerosols disperse in the surrounding space, posing a health threat if the patient is infected with a transmittable disease, particularly COVID-19. Here, a viscoelastic polyacrylic acid (PAA) solution was used to minimize liquid aerosolization and limit the travel distance of aerosols. The PAA concentration was varied to evaluate its effect on aerosolization and droplet size resulting from procedures using dental handpieces, which include tooth cutting, grinding, and polishing. In addition, a thermocouple was inserted at the center of the model tooth to measure its temperature during a handpiece operation. The temperature data suggest that the cooling performance of the PAA solution is comparable to that of pure water in operations in the occlusal and facial directions. The PAA solution droplets splattered on the patient's facial area during the handpiece operation are markedly larger than those of pure water, which is evidence of the settling of the PAA droplets, preventing further transmission. Accordingly, the travel distance of the aerosolized PAA droplets was limited by viscoelastic resistance to droplet detachment. This comparison of the aerosol suppression capability between water and PAA solutions confirms the benefit of using viscoelastic solutions for various dental operations.