Lei Su
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lei Su has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Boyu Zhou
School of Civil and Transportation Engineering, Hebei University of Technology, Tianjin 300401, China
1 shared publication - Fan Yang
College of Automation and the College of Artificial Intelligence, Nanjing University of Posts and Telecommunications, Nanjing, China
1 shared publication Han Gang
Electric Power Science Research Institute of State Grid Hubei Electric Power Co., Ltd,Wuhan,HUBEI
1 shared publication- Haoyu Wang
School of Civil Engineering, Tianjin Renai College, Tianjin 301636, China
1 shared publication - Lei Yang
The Hong Kong Polytechnic University
1 shared publication Min Huaidong
1 shared publication
Latest Publications
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 42, 1-7
Testing and Verification of Distribution Transformer Substation Area Flexible Interconnection Technology Considering Multiflow Fusion
In this paper, the development requirements of flexible interconnection technology in power distribution transformer station area are analyzed firstly, and the architecture of “acquisition, transmission, storage and application” is given by combining five power distribution transformer station area flexible interconnection systems. The characteristics of flexible interconnection in power distribution transformer station area are analyzed from the perspectives of multi-flow integration, such as energy flow, information flow, control flow and service flow. The paper focuses on load balancing, fault transfer and black start in the service flow, and gives the control scheme of flexible interconnection operation of multi-current fusion distribution transformer station area. Finally, it sets up two real type empirical simulation platforms of flexible interconnection system of distribution transformer station area in the laboratory environment. The monitoring function of energy flow-information flow-control flow, fault disposal service flow and power mutual exchange service flow of the interconnected system are verified, which provides technical support for the next stage flexible interconnection demonstration project construction of distribution transformer platform area.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 42, 1-7
Testing and Verification of Distribution Transformer Substation Area Flexible Interconnection Technology Considering Multiflow Fusion
In this paper, the development requirements of flexible interconnection technology in power distribution transformer station area are analyzed firstly, and the architecture of “acquisition, transmission, storage and application” is given by combining five power distribution transformer station area flexible interconnection systems. The characteristics of flexible interconnection in power distribution transformer station area are analyzed from the perspectives of multi-flow integration, such as energy flow, information flow, control flow and service flow. The paper focuses on load balancing, fault transfer and black start in the service flow, and gives the control scheme of flexible interconnection operation of multi-current fusion distribution transformer station area. Finally, it sets up two real type empirical simulation platforms of flexible interconnection system of distribution transformer station area in the laboratory environment. The monitoring function of energy flow-information flow-control flow, fault disposal service flow and power mutual exchange service flow of the interconnected system are verified, which provides technical support for the next stage flexible interconnection demonstration project construction of distribution transformer platform area.
- Open Access
- 15 February 2022
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2022, 1-13
Determination of Gel Products in Alkali-Activated Fly Ash-Based Composites Incorporating Inorganic Calcium Additives
The introduction of soluble calcium additives contributes to forming calcium-containing geopolymer (N,C)-A-S-H and/or calcium (alumino)silicate hydration C-(A)-S-H in alkali-activated fly ash-based composites (AAFCs). However, the quantitative determination of the final gel product has yet been unclear due to the different chemical components, which influences the prediction of mechanical strength and microstructure. This study aims to propose a method to clarify the gel products in AAFCs by the critical elemental compositions in gel products. Furthermore, the AAFCs were prepared (by casting method) using soda residue (SR) as the calcium additive, fly ash as the aluminosilicate precursor, and sodium silicate solution as the alkaline activator. The compressive strengths of the AAFCs with different SR contents were recorded. The microstructures and gel products of AAFCs were detected through scanning electron microscope (SEM), energy-dispersive spectroscopy (EDS), X-ray diffraction (XRD), and 29Si nuclear magnetic resonance spectrometer (29Si NMR). Finally, the proposed determination method was verified with the experimental results. The new proposed quantitative method refers to a limit value of 2Ca/Al=1.00 about the critical chemical elements in gel products, which helps to determine the calcium-containing geopolymer (N,C)-A-S-H or/and calcium (alumino)silicate hydration C-(A)-S-H in stable AAFCs. Results show that the gel products are determined as single (N,C)-A-S-H gels when 2Ca/Al is lower than 1.00; meanwhile, (N,C)-A-S-H and C-(A)-S-H gels coexist when 2Ca/Al is higher than 1.00 by the above proposed quantitative determination method. Furthermore, it works that the industrial solid waste SRs regarded as calcium additive are applied in the AAFCs to verify the gel products by 2Ca/Al=1.00 as the limit value. The results provide the theoretical and experimental basis for the performance prediction and microstructural determination.
- 15 February 2022
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2022, 1-13
Open AccessDetermination of Gel Products in Alkali-Activated Fly Ash-Based Composites Incorporating Inorganic Calcium Additives
The introduction of soluble calcium additives contributes to forming calcium-containing geopolymer (N,C)-A-S-H and/or calcium (alumino)silicate hydration C-(A)-S-H in alkali-activated fly ash-based composites (AAFCs). However, the quantitative determination of the final gel product has yet been unclear due to the different chemical components, which influences the prediction of mechanical strength and microstructure. This study aims to propose a method to clarify the gel products in AAFCs by the critical elemental compositions in gel products. Furthermore, the AAFCs were prepared (by casting method) using soda residue (SR) as the calcium additive, fly ash as the aluminosilicate precursor, and sodium silicate solution as the alkaline activator. The compressive strengths of the AAFCs with different SR contents were recorded. The microstructures and gel products of AAFCs were detected through scanning electron microscope (SEM), energy-dispersive spectroscopy (EDS), X-ray diffraction (XRD), and 29Si nuclear magnetic resonance spectrometer (29Si NMR). Finally, the proposed determination method was verified with the experimental results. The new proposed quantitative method refers to a limit value of 2Ca/Al=1.00 about the critical chemical elements in gel products, which helps to determine the calcium-containing geopolymer (N,C)-A-S-H or/and calcium (alumino)silicate hydration C-(A)-S-H in stable AAFCs. Results show that the gel products are determined as single (N,C)-A-S-H gels when 2Ca/Al is lower than 1.00; meanwhile, (N,C)-A-S-H and C-(A)-S-H gels coexist when 2Ca/Al is higher than 1.00 by the above proposed quantitative determination method. Furthermore, it works that the industrial solid waste SRs regarded as calcium additive are applied in the AAFCs to verify the gel products by 2Ca/Al=1.00 as the limit value. The results provide the theoretical and experimental basis for the performance prediction and microstructural determination.