YXYan Xu

Yan Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yan Xu has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Fault line selection algorithm for distribution networks based on AdapGL‐GIN network

    by Tong Lu, Sizu Hou, Yan Xu

    When a grounding fault occurs in the distribution network with distributed generation, the network topology becomes intricate, making it challenging to extract fault characteristics, resulting in a decrease in the precision of fault discrimination. To address this issue, a graph isomorphism network (GIN) approach based on the parameterized adaptive graph learning (AdapGL) module is proposed, transforming the distribution network fault selection problem into a graph classification task. First, the adjacency matrix of the distribution network's topology graph is initialized. This matrix, combined with feature vectors from the robust local mean decomposition energy entropy and transient dielectric loss angle of line, will be input into the GIN. Then, the AdapGL module is integrated into the GIN, dynamically learning and updating the one‐way relationships between actual network nodes to complete the graph classification task. Finally, a radial distribution network model (RDNM) and an improved IEEE 34 nodes model are established, and the fault selection results of the AdapGL‐GIN method are compared with those of other methods. The results indicate that the proposed method achieves higher accuracy than other methods, demonstrating significant practical importance in engineering applications.


  • Open Access

    Ultra-Short-Term Load Forecasting for Customer-Level Integrated Energy Systems Based on Composite VTDS Models

    by Tong Lu, Sizu Hou, Yan Xu

    A method is proposed to address the challenging issue of load prediction in user-level integrated energy systems (IESs) using a composite VTDS model. Firstly, an IES multi-dimensional load time series is decomposed into multiple intrinsic mode functions (IMFs) using variational mode decomposition (VMD). Then, each IMF, along with other influential features, is subjected to data dimensionality reduction and clustering denoising using t-distributed stochastic neighbor embedding (t-SNE) and fast density-based spatial clustering of applications with noise (FDBSCAN) to perform major feature selection. Subsequently, the reduced and denoised data are reconstructed, and a time-aware long short-term memory (T-LSTM) artificial neural network is employed to fill in missing data by incorporating time interval information. Finally, the selected multi-factor load time series is used as input into a support vector regression (SVR) model optimized using the quantum particle swarm optimization (QPSO) algorithm for load prediction. Using measured load data from a specific user-level IES at the Tempe campus of Arizona State University, USA, as a case study, a comparative analysis between the VTDS method and other approaches is conducted. The results demonstrate that the method proposed in this study achieved higher accuracy in short-term forecasting of the IES’s multiple loads.


  • Open Access

    Fault line selection algorithm for distribution networks based on improved EWT and GIN network

    by Sizu Hou, Yan Xu, Tong Lu

    When a single-phase grounding fault occurs in a power distribution system, the fault characteristics are not prominent and are easily drowned out by noise, making fault line selection difficult. A fault line selection method based on improved empirical wavelet transform (EWT) and GIN network is proposed to solve this problem. Firstly, EWT is optimized using kurtosis as the basis and N-point search method. EWT decomposes the electrical signal into a series of modal components, and noise is filtered out by weighted permutation entropy to reconstruct the signal, obtaining a denoised electrical signal. Then, according to the topology of the power distribution network, a corresponding graph structure is constructed. The Mahalanobis distance between each point and the overall structure in the denoised electrical signal is calculated and used as the input to each node in the GIN network. Finally, the GIN network autonomously mines the characteristics of each graph structure, performs graph classification, and realizes fault line selection. Experimental results show that the proposed method has a solid anti-noise ability and an accuracy of up to 99.95%, effectively completing fault line selection in power distribution networks.


  • Open Access

    Distribution Network Fault-Line Selection Method Based on MICEEMDAN–Recurrence Plot–Yolov5

    by Sizu Hou, Yan Xu, Wei Guo

    Distribution system fault signals contain severe noise components. In order to solve the problem of distribution network fault-line selection, a fault-line selection method based on modifying the Improved Complete Ensemble Empirical Mode Decomposition Adaptive Noise (MICEEMDAN) algorithm, Recurrence Plot, and Yolov5 network is proposed. First, ICEEMDAN is optimized using multi-scale weighted permutation entropy (MWPE). MICEEMDAN can decompose an electrical signal into a series of intrinsic mode functions (IMFs). Recurrence Plot transformation of all IMFs, obtained from decomposition and stitching from top to bottom, realizes the conversion of 1D time series to 2D images. Then, the recurrence maps obtained from all lines in the distribution network are stitched to obtain the distribution network recurrence map, realizing the mining of the fault-signal features of the whole distribution network. Finally, the Yolov5 network is used to mine the fault features of the recurrence map of the distribution network autonomously to realize the fault-line selection. The experiments show that the method has a good noise immunity and 99.98% fault-selection accuracy, which can effectively complete the distribution network fault selection.