Wenyun Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wenyun Li has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Fangrong Zhou
Electric Power Research Institute, Yunnan Power Grid Co., Ltd., Kunming 650217, China
4 shared publications - Gang Ao
Yunnan Power Grid Co., Ltd., Kunming Power Supply Bureau, Kunming 650001, China
3 shared publications - Xiangyu Tan
Electric Power Research Institute, Yunnan Power Grid Co., Ltd., Kunming 650217, China
3 shared publications - Qinghua Tan
College of Mechanical and Electrical Engineering, Kunming University of Science and Technology, Kunming 650504, China
2 shared publications - Wenbin Zhang
Kunming University of Science and Technology, Kunming, China
2 shared publications - Xiaowei Xu
Electric Power Research Institute, Yunnan Power Grid Co., Ltd., Kunming 650504, China
2 shared publications
Latest Publications
- Open Access
Surface Wear Monitoring System of Industrial Transformer Tap-Changer Contacts by Using Voice Signal
Surface wear of the tap-changer contacts of industrial transformers (due to frequent switching times) easily leads to operation failure of industrial transformers, which affects the safety and stability of the transmission network. In this paper, an intelligent voice signal monitoring system was proposed for the abnormal condition (surface wear) of tap-changer contacts. This monitoring system was composed of a voice signal acquisition system, voice analysis system and voice processing system. First, the voice signal of the tap-changer contacts was collected, and the collected voice signal was analyzed in the time domain and the frequency domain. Secondly, the characteristic curve of the voice signal was proposed, and the voice curve was compared with that of the normal operation state. In this case, the running state and surface wear abnormal situation of the tap changer could be monitored and determined, and the cause of the abnormal state could also be further analyzed. This method solved the surface wear problem of the tap changer in industrial transformers, which could be not monitored effectively in real time. This method improved the operational reliability of industrial transformers and had high economic and social benefits.
Open AccessSurface Wear Monitoring System of Industrial Transformer Tap-Changer Contacts by Using Voice Signal
Surface wear of the tap-changer contacts of industrial transformers (due to frequent switching times) easily leads to operation failure of industrial transformers, which affects the safety and stability of the transmission network. In this paper, an intelligent voice signal monitoring system was proposed for the abnormal condition (surface wear) of tap-changer contacts. This monitoring system was composed of a voice signal acquisition system, voice analysis system and voice processing system. First, the voice signal of the tap-changer contacts was collected, and the collected voice signal was analyzed in the time domain and the frequency domain. Secondly, the characteristic curve of the voice signal was proposed, and the voice curve was compared with that of the normal operation state. In this case, the running state and surface wear abnormal situation of the tap changer could be monitored and determined, and the cause of the abnormal state could also be further analyzed. This method solved the surface wear problem of the tap changer in industrial transformers, which could be not monitored effectively in real time. This method improved the operational reliability of industrial transformers and had high economic and social benefits.
- Open Access
Non-Contact Adaptive Voltage Sensor Based on Electric Field Coupling Principle
Non-contact voltage sensors based on the principle of electric field coupling have the advantages of simple loading and unloading, high construction safety, and the fact that they are not affected by line insulation. They can accurately measure line voltage without the need to connect to the measured object. Starting from the principle of non-contact voltage measurement, this article abstracts a non-contact voltage measurement model into the principle of capacitive voltage sharing and deduces its transfer relationship. Secondly, it is theoretically inferred that the edge effect of the traditional symmetric structure sensor plate will cause the actual capacitance value between the sensor plates to be greater than the theoretically calculated capacitance value, resulting in a certain measurement error. Therefore, the addition of an equipotential ring structure is proposed to eliminate the edge additional capacitance caused by the edge effect in order to design the sensor structure. In addition, due to the influence of sensor volume, material dielectric constant, and other factors, the capacitance value of the sensor itself is only at pF level, resulting in poor low-frequency performance and imbuing the sensor with a low voltage division ratio. In this regard, this article analyzes the measurement principle of non-contact voltage sensors. By paralleling ceramic capacitors between the two electrode plates of the sensor, the capacitance of the sensor itself is effectively increased, improving the low-frequency performance of the sensor while also increasing the sensor’s voltage division ratio. In addition, by introducing a single pole double throw switch to switch parallel capacitors with different capacitance values, the sensor can have different voltage division ratios in different measurement scenarios, giving it a certain degree of adaptability. The final sensor prototype was made, and a high and low voltage experimental platform was built to test the sensor performance. The experimental results showed that the sensor has good linearity and high measurement accuracy, with a ratio error of within ±3%.
Open AccessNon-Contact Adaptive Voltage Sensor Based on Electric Field Coupling Principle
Non-contact voltage sensors based on the principle of electric field coupling have the advantages of simple loading and unloading, high construction safety, and the fact that they are not affected by line insulation. They can accurately measure line voltage without the need to connect to the measured object. Starting from the principle of non-contact voltage measurement, this article abstracts a non-contact voltage measurement model into the principle of capacitive voltage sharing and deduces its transfer relationship. Secondly, it is theoretically inferred that the edge effect of the traditional symmetric structure sensor plate will cause the actual capacitance value between the sensor plates to be greater than the theoretically calculated capacitance value, resulting in a certain measurement error. Therefore, the addition of an equipotential ring structure is proposed to eliminate the edge additional capacitance caused by the edge effect in order to design the sensor structure. In addition, due to the influence of sensor volume, material dielectric constant, and other factors, the capacitance value of the sensor itself is only at pF level, resulting in poor low-frequency performance and imbuing the sensor with a low voltage division ratio. In this regard, this article analyzes the measurement principle of non-contact voltage sensors. By paralleling ceramic capacitors between the two electrode plates of the sensor, the capacitance of the sensor itself is effectively increased, improving the low-frequency performance of the sensor while also increasing the sensor’s voltage division ratio. In addition, by introducing a single pole double throw switch to switch parallel capacitors with different capacitance values, the sensor can have different voltage division ratios in different measurement scenarios, giving it a certain degree of adaptability. The final sensor prototype was made, and a high and low voltage experimental platform was built to test the sensor performance. The experimental results showed that the sensor has good linearity and high measurement accuracy, with a ratio error of within ±3%.
- Open Access
Design of a Fluxgate Weak Current Sensor with Anti-Low Frequency Interference Ability
According to the requirements of weak current measurement in power grid, a weak current sensor with anti-low frequency interference ability is developed. The sensor adopts the principle of fluxgate detection and adds a magnetic ring on the original basis. The structure of the magnetic ring is simulated using comsol to further improve detection sensitivity. In order to solve the problem that the electromagnetic current sensor is vulnerable to the interference of geomagnetic field and power frequency magnetic field in weak current measurement, a magnetic shielding method with low cost is selected, and the shielding shell structure is designed using a finite element analysis method. The experimental results show that the minimum measurable current is 1 mA, the measurement range is 1 mA–1 A, and the bandwidth is DC-16 kHz. The designed magnetic shielding shell can effectively reduce 97.3% of the DC magnetic field interference and 95.7% of the power frequency magnetic field interference. The sensor can realize accurate measurement of weak current in power grid.
Open AccessDesign of a Fluxgate Weak Current Sensor with Anti-Low Frequency Interference Ability
According to the requirements of weak current measurement in power grid, a weak current sensor with anti-low frequency interference ability is developed. The sensor adopts the principle of fluxgate detection and adds a magnetic ring on the original basis. The structure of the magnetic ring is simulated using comsol to further improve detection sensitivity. In order to solve the problem that the electromagnetic current sensor is vulnerable to the interference of geomagnetic field and power frequency magnetic field in weak current measurement, a magnetic shielding method with low cost is selected, and the shielding shell structure is designed using a finite element analysis method. The experimental results show that the minimum measurable current is 1 mA, the measurement range is 1 mA–1 A, and the bandwidth is DC-16 kHz. The designed magnetic shielding shell can effectively reduce 97.3% of the DC magnetic field interference and 95.7% of the power frequency magnetic field interference. The sensor can realize accurate measurement of weak current in power grid.
- Open Access
Contactless AC/DC Wide-Bandwidth Current Sensor Based on Composite Measurement Principle
With the accelerated construction of the smart grid, new energy sources such as photovoltaic and wind power are connected to the grid. In addition to power frequency, the current signal of power grid also includes several DC signals, as well as medium-high and high-frequency transient signals. Traditional current sensors for power grids are bulky, have a narrow measurement range, and cannot measure both AC and DC at the same time. Therefore, this paper designs a non-intrusive, AC-DC wide-bandwidth current sensor based on the composite measurement principle. The proposed composite current detection scheme combines two different isolation detection technologies, namely tunneling reluctance and the Rogowski coil. These two current sensing techniques are complementary (tunneling magnetoresistive sensors have good low-frequency characteristics and Rogowski coils have good high-frequency characteristics, allowing for a wide detection bandwidth). Through theoretical and simulation analysis, the feasibility of the composite measurement scheme was verified. The prototype of composite current sensor was developed. The DC and AC transmission characteristics of the sensor prototype were measured, and the sensitivity and linearity were 11.96 mV/A, 1.14%, respectively. Finally, the sweep current method and pulse current method experiments prove that the designed composite current sensor can realize the current measurement from DC to 17 MHz.
Open AccessContactless AC/DC Wide-Bandwidth Current Sensor Based on Composite Measurement Principle
With the accelerated construction of the smart grid, new energy sources such as photovoltaic and wind power are connected to the grid. In addition to power frequency, the current signal of power grid also includes several DC signals, as well as medium-high and high-frequency transient signals. Traditional current sensors for power grids are bulky, have a narrow measurement range, and cannot measure both AC and DC at the same time. Therefore, this paper designs a non-intrusive, AC-DC wide-bandwidth current sensor based on the composite measurement principle. The proposed composite current detection scheme combines two different isolation detection technologies, namely tunneling reluctance and the Rogowski coil. These two current sensing techniques are complementary (tunneling magnetoresistive sensors have good low-frequency characteristics and Rogowski coils have good high-frequency characteristics, allowing for a wide detection bandwidth). Through theoretical and simulation analysis, the feasibility of the composite measurement scheme was verified. The prototype of composite current sensor was developed. The DC and AC transmission characteristics of the sensor prototype were measured, and the sensitivity and linearity were 11.96 mV/A, 1.14%, respectively. Finally, the sweep current method and pulse current method experiments prove that the designed composite current sensor can realize the current measurement from DC to 17 MHz.