  • Partial Discharge Monitoring of C3F7CN/CO2 Mixture Retrofilled in Gas Insulated Busbar

    by Prem Ranjan, Maria Oancea, Qinghua Han, Faisal Omar Bahdad, Constantinos Onoufriou, Malcolm Seltzer-Grant, Roberto Fernandez Bautista, Lujia Chen

    Condition monitoring of gas insulated high voltage equipment is important to ensure reliable operation of electricity networks. Partial discharge (PD) monitoring is well established for existing SF 6 equipment, but still in its infancy for the emerging SF 6 alternatives as the power industry transitions from SF 6 . PD characteristics of 20% C 3 F 7 CN / 80% CO 2 gas mixture as a viable retrofill solution were extensively investigated over extended energization periods in a busbar demonstrator designed for SF 6 and rated to 420/550 kV. Protrusions of 3, 5, 10 and 15 mm needle lengths were used on the high voltage conductor for comparative PD investigations of SF 6 and 20% C 3 F 7 CN / 80% CO 2 gas mixture. PD activity was measured with IEC 60270 (apparent charge) and ultra-high frequency (UHF) detection methods. The PD patterns recorded for all needle lengths were representative of a protrusion-on-conductor defect and the two PD detection methods were comparable. For identical defect lengths, SF 6 showed a comparatively longer time-to-breakdown when compared to a 20% C 3 F 7 CN / 80% CO 2 mixture. Results obtained in a controlled laboratory environment demonstrate wider applicability to field measurements of C 3 F 7 CN based mixtures adopted for retrofill application in SF 6 -designed gas insulated busbar.


  • Open Access

    Partial Discharge Characteristics of C3F7CN Gas Mixture Using the UHF Method

    by Loizos Loizou, Qinghua Han, Lujia Chen, Qiang Liu, Mark Waldron, Gordon Wilson, Roberto Fernandez Bautista, Malcolm Seltzer-Grant

    Manufacturing or assembly defects in gas-insulated equipment can introduce field enhancements that could lead to partial discharge (PD). This paper examines the PD characteristics of SF6 alternatives considered for potential application to retro-filling existing SF6-designed equipment. The PD performance of the C3F7CN/CO2 gas mixture and SF6 were characterised adopting the ultra-high frequency (UHF) method and investigated for different defect configurations, pressures, and gas mediums. Hemispherical rod-plane and plane-to-plane configurations with needle on the high-voltage (HV) and ground electrodes were used to mimic conductor and enclosure protrusion defects, respectively. The results demonstrate that with a needle length of 15 mm, the 20% C3F7CN/80% CO2 gas mixture had almost half the partial discharge inception and extinction voltages (PDIV/EV) of SF6. For less divergent fields, the 20% C3F7CN/80% CO2 gas mixture demonstrated a comparable PDIV/EV performance as SF6. The phase-resolved PD patterns of the 20% C3F7CN/80% CO2 gas mixture demonstrated a 3-stage transition phase that was not observed with SF6, which could be due to the discharge mechanism of the weakly attaching CO2 gas used within the mixture.