Shuomang Shi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shuomang Shi has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Luyang Xu
Department of Civil, Construction, and Environmental Engineering, North Dakota State University, Fargo, ND 58102, USA
2 shared publications - Ying Huang
Department of Civil, Construction, and Environmental Engineering, North Dakota State University, Fargo, ND 58102, USA
2 shared publications - Baiyu Jiang
Department of Civil and Environmental Engineering, School of Engineering, Rutgers, The State University of New Jersey, New Brunswick, NJ 08901, USA
1 shared publication - Dawei Zhang
Beijing Jiaotong Univ
1 shared publication - Di Wu
Department of Electrical and Computer Engineering, North Dakota State University, Fargo, ND, USA
1 shared publication - Fei Yan
Department of Civil, Construction, and Environmental Engineering, North Dakota State University, Fargo, ND 58105, USA
1 shared publication
Latest Publications
- Open Access
Structural Vulnerability Analysis of Interdependent Electric Power and Natural Gas Systems
The growing use of gas-fired power generators and electricity-driven gas compressors and storage has increased the interdependence between electric power infrastructure and natural gas infrastructure. However, the increasing interdependence may spread the failures from one system to the other, causing subsequent failures in an integrated power and gas system (IPGS). This paper investigates the structural vulnerability of a realistic IPGS based on complex network theory. Different from the existing works with a focus on the static vulnerability analysis for an IPGS, this paper considers both static and dynamic vulnerability analysis. The former focuses on vulnerability analysis under random and selective failures without flow redistribution, while the latter concentrates on vulnerability analysis under cascading failures caused by flow redistribution. Also, different from the existing works with a focus on the IPGS as a whole, we not only analyze the vulnerability of the IPGS but also analyze the vulnerability of the power subsystem (PS) and gas subsystem (GS), in order to understand how the vulnerability of the IPGS is affected by its PS and GS. The analysis results show that (1) if the PS and GS are more susceptible to cascading failures than selective and random failures, the IPGS as a whole is also more vulnerable to cascading failures. (2) There are different dominant factors affecting the IPGS vulnerability under cascading failures and selective failures. Under cascading failures, the GS has a more significant impact on the IPGS vulnerability; under selective failures, the PS has a more important impact on the IPGS vulnerability. (3) The IPGS is more vulnerable to failures on the critical nodes, which are identified from the IPGS as a whole rather than from the individual PS or GS. The results provide insights into the design and planning of IPGSs to improve their overall reliability.
Open AccessStructural Vulnerability Analysis of Interdependent Electric Power and Natural Gas Systems
The growing use of gas-fired power generators and electricity-driven gas compressors and storage has increased the interdependence between electric power infrastructure and natural gas infrastructure. However, the increasing interdependence may spread the failures from one system to the other, causing subsequent failures in an integrated power and gas system (IPGS). This paper investigates the structural vulnerability of a realistic IPGS based on complex network theory. Different from the existing works with a focus on the static vulnerability analysis for an IPGS, this paper considers both static and dynamic vulnerability analysis. The former focuses on vulnerability analysis under random and selective failures without flow redistribution, while the latter concentrates on vulnerability analysis under cascading failures caused by flow redistribution. Also, different from the existing works with a focus on the IPGS as a whole, we not only analyze the vulnerability of the IPGS but also analyze the vulnerability of the power subsystem (PS) and gas subsystem (GS), in order to understand how the vulnerability of the IPGS is affected by its PS and GS. The analysis results show that (1) if the PS and GS are more susceptible to cascading failures than selective and random failures, the IPGS as a whole is also more vulnerable to cascading failures. (2) There are different dominant factors affecting the IPGS vulnerability under cascading failures and selective failures. Under cascading failures, the GS has a more significant impact on the IPGS vulnerability; under selective failures, the PS has a more important impact on the IPGS vulnerability. (3) The IPGS is more vulnerable to failures on the critical nodes, which are identified from the IPGS as a whole rather than from the individual PS or GS. The results provide insights into the design and planning of IPGSs to improve their overall reliability.
- Open Access
Optimization for Pipeline Corrosion Sensor Placement in Oil-Water Two-Phase Flow Using CFD Simulations and Genetic Algorithm
Internal corrosion is a major concern in ensuring the safety of transmission and gathering pipelines in Structural Health Monitoring (SHM). It usually requires numerous sensors deployed inside the piping system to comprehensively cover the locations with high corrosion rates. This study presents a hybrid modeling strategy using Computational Fluid Dynamics (CFD) and Genetic Algorithm (GA) to improve the sensor placement scheme for corrosion detection and monitoring. The essence of the proposed strategy harnesses the well-validated physical modeling capability of the CFD to simulate the oil-water two-phase flow and the stochastic searching ability of the GA to explore better solutions on a global level. The CFD-based corrosion rate prediction was validated through experimental results and further used to form the initial population for GA optimization. Importantly, fitness was defined by considering both sensing effectiveness and cost of sensor coverage. The hybrid modeling strategy was implemented through case studies, where three typical pipe fittings were used to demonstrate the applicability of the sensor layout design for corrosion detection in pipelines. The GA optimization results show high accuracy for sensor placement inside the pipelines. The best fitness of the U-shaped, upward-inclined, and downward-inclined pipes were 0.9415, 0.9064, and 0.9183, respectively. Upon this, the hybrid modeling strategy can provide a promising tool for the pipeline industry to design the practical placement.
Open AccessOptimization for Pipeline Corrosion Sensor Placement in Oil-Water Two-Phase Flow Using CFD Simulations and Genetic Algorithm
Internal corrosion is a major concern in ensuring the safety of transmission and gathering pipelines in Structural Health Monitoring (SHM). It usually requires numerous sensors deployed inside the piping system to comprehensively cover the locations with high corrosion rates. This study presents a hybrid modeling strategy using Computational Fluid Dynamics (CFD) and Genetic Algorithm (GA) to improve the sensor placement scheme for corrosion detection and monitoring. The essence of the proposed strategy harnesses the well-validated physical modeling capability of the CFD to simulate the oil-water two-phase flow and the stochastic searching ability of the GA to explore better solutions on a global level. The CFD-based corrosion rate prediction was validated through experimental results and further used to form the initial population for GA optimization. Importantly, fitness was defined by considering both sensing effectiveness and cost of sensor coverage. The hybrid modeling strategy was implemented through case studies, where three typical pipe fittings were used to demonstrate the applicability of the sensor layout design for corrosion detection in pipelines. The GA optimization results show high accuracy for sensor placement inside the pipelines. The best fitness of the U-shaped, upward-inclined, and downward-inclined pipes were 0.9415, 0.9064, and 0.9183, respectively. Upon this, the hybrid modeling strategy can provide a promising tool for the pipeline industry to design the practical placement.
- Open Access
Monitoring Epoxy Coated Steel under Combined Mechanical Loads and Corrosion Using Fiber Bragg Grating Sensors
Fiber Bragg grating (FBG) sensors have been applied to assess strains, stresses, loads, corrosion, and temperature for structural health monitoring (SHM) of steel infrastructure, such as buildings, bridges, and pipelines. Since a single FBG sensor measures a particular parameter at a local spot, it is challenging to detect different types of anomalies and interactions of anomalies. This paper presents an approach to assess interactive anomalies caused by mechanical loading and corrosion on epoxy coated steel substrates using FBG sensors in real time. Experiments were performed by comparing the monitored center wavelength changes in the conditions with loading only, corrosion only, and simultaneous loading and corrosion. The theoretical and experimental results indicated that there were significant interactive influences between loading and corrosion for steel substrates. Loading accelerated the progress of corrosion for the epoxy coated steel substrate, especially when delamination in the epoxy coating was noticed. Through the real-time monitoring from the FBG sensors, the interactions between the anomalies induced by the loading and corrosion can be quantitatively evaluated through the corrosion depth and the loading contact length. These fundamental understandings of the interactions of different anomalies on steel structures can provide valuable information to engineers for better management of steel structures.
Open AccessMonitoring Epoxy Coated Steel under Combined Mechanical Loads and Corrosion Using Fiber Bragg Grating Sensors
Fiber Bragg grating (FBG) sensors have been applied to assess strains, stresses, loads, corrosion, and temperature for structural health monitoring (SHM) of steel infrastructure, such as buildings, bridges, and pipelines. Since a single FBG sensor measures a particular parameter at a local spot, it is challenging to detect different types of anomalies and interactions of anomalies. This paper presents an approach to assess interactive anomalies caused by mechanical loading and corrosion on epoxy coated steel substrates using FBG sensors in real time. Experiments were performed by comparing the monitored center wavelength changes in the conditions with loading only, corrosion only, and simultaneous loading and corrosion. The theoretical and experimental results indicated that there were significant interactive influences between loading and corrosion for steel substrates. Loading accelerated the progress of corrosion for the epoxy coated steel substrate, especially when delamination in the epoxy coating was noticed. Through the real-time monitoring from the FBG sensors, the interactions between the anomalies induced by the loading and corrosion can be quantitatively evaluated through the corrosion depth and the loading contact length. These fundamental understandings of the interactions of different anomalies on steel structures can provide valuable information to engineers for better management of steel structures.