Gianluca Coltrinari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gianluca Coltrinari has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Antonucci
Università degli Studi Roma Tre, DIIEM , Italy
1 shared publication - Danilo Monarca
Department of Agriculture and Forest Sciences (DAFNE), Tuscia University, 01100 Viterbo, Italy
1 shared publication - Dario Lippiello
Department of Engineering, University of Roma Tre, Italy
1 shared publication - Guido Alfaro Degan
Department of Engineering, University of Roma Tre, Italy
1 shared publication - Leonardo Assettati
University of Tuscia
1 shared publication - Leonardo Bianchini
Department of Agriculture and Forest Sciences (DAFNE), University of Tuscia, 01100 Viterbo, Italy
1 shared publication
Latest Publications
- 13 April 2025
- Published by Springer Nature
- p. 389-395
Exposure to Noise and Vibrations for Workers Involved in Mechanized Almond Harvesting
- 13 April 2025
- Published by Springer Nature
- p. 389-395
Exposure to Noise and Vibrations for Workers Involved in Mechanized Almond Harvesting
- 24 May 2022
- Published by Taylor & Francis in International Journal of Occupational Safety and Ergonomics
- Vol. 29 (2) , 704-716
Problems related to measuring the transmissibility of anti-vibration gloves: possible efficacy for impact tools used in mining and quarrying activities
This article takes into account some of the most relevant studies investigating the transmissibility of anti-vibration (AV) gloves. AV gloves are almost useless at the palm level in the low frequencies (<31.5 Hz), while they generally start to have an appreciable reduction of the vibration over 400 Hz. In their use with impact tools, having a low dominant vibration frequency usually between 25 and 60 Hz for chipping hammers and drills, and less than 30 Hz for pneumatic breakers, the average transmissibility reduction at the palm level is 13% (minimum 2%; maximum 26%) when used with hammers, and 1% (increment of 4% and reduction of 6%) when used with breakers. The transmissibility at the finger level, especially in the low frequencies, is almost nothing or produces an increase of the vibration. Other problems related to the increase of the applied force and the reduction of dexterity are reported.
- 24 May 2022
- Published by Taylor & Francis in International Journal of Occupational Safety and Ergonomics
- Vol. 29 (2) , 704-716
Problems related to measuring the transmissibility of anti-vibration gloves: possible efficacy for impact tools used in mining and quarrying activities
This article takes into account some of the most relevant studies investigating the transmissibility of anti-vibration (AV) gloves. AV gloves are almost useless at the palm level in the low frequencies (<31.5 Hz), while they generally start to have an appreciable reduction of the vibration over 400 Hz. In their use with impact tools, having a low dominant vibration frequency usually between 25 and 60 Hz for chipping hammers and drills, and less than 30 Hz for pneumatic breakers, the average transmissibility reduction at the palm level is 13% (minimum 2%; maximum 26%) when used with hammers, and 1% (increment of 4% and reduction of 6%) when used with breakers. The transmissibility at the finger level, especially in the low frequencies, is almost nothing or produces an increase of the vibration. Other problems related to the increase of the applied force and the reduction of dexterity are reported.