Stefan Steiner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Stefan Steiner has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Clemens Vass
Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
3 shared publications Florian Schwarzhans
Research Center for Medical Image Analysis and Artificial Intelligence (MIAAI), Danube Private University, Krems an der Donau, Austria
2 shared publicationsGeorg Fischer
Center for Medical Statistics Informatics and Intelligent Systems, Section for Medical Information Management and Imaging, Medical University of Vienna, Vienna, Austria
2 shared publicationsMichael Pircher
Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
2 shared publicationsAllison Jones-Farmer
Department of Information Systems and Analytics, Miami University, Oxford, Ohio
1 shared publicationAngela Patterson
General Electric and Virginia Tech, Blacksburg, Virginia
1 shared publication
Latest Publications
- Open Access
- 24 December 2025
- Published by BMJ in British Journal of Ophthalmology
- Vol. 110 (7) , 793-801
The retinal nerve fibre layer thickness slope: a localised biomarker of the structure–function relationship in early glaucoma
Background/aims: To describe the relationship between the novel biomarker retinal nerve fibre layer thickness slope (RNFL-S), and visual field sensitivity (VFS) in healthy and early glaucoma eyes. Methods: This prospective cross-sectional study of 50 early glaucoma and 139 healthy eyes analysed RNFL-S locally along retinal nerve fibre trajectories that were automatically traced and centred on 24–2 and 10–2 visual field (VF) test points. Corresponding virtual B-scans were extracted from stitched wide-field polarisation-sensitive optical coherence tomography images. A linear mixed-effects model (LMM) assessed the association between VFS and the factors RNFL-S, glaucoma status and age. Results: The average VF mean deviation was −3.11±1.51 dB in glaucoma (mean age: 63.0±9.3 years) and −0.36±1.10 dB in healthy eyes (mean age: 47.9±16.3 years). In healthy subjects, VFS and the corresponding RNFL-S were 31.8±2.4 dB (12.5±2.9 µm/mm) in the upper hemisphere and 32.4±2.2 dB (12.5±2.5 µm/mm) in the lower hemisphere. In glaucoma patients, these values were significantly lower: 27.5±7.0 dB (8.6 ± 3.9 µm/mm, p<0.001) in the upper hemisphere and 30.1±4.3 dB (10.5±3.3 µm/mm, p<0.001) in the lower hemisphere. Significant point-wise Spearman correlation coefficients (up to r=0.61) were observed, particularly in the upper VF hemisphere within the central 10° and close to the optic nerve head. The LMM showed a positive association between VFS and RNFL-S (β=0.0415, SE=0.0023, p<0.001, R²=0.1885). Glaucoma was significantly associated with lower VFS (β=−2.468, SE=0.069, p<0.001). Age negatively correlated with VFS (β=−0.048, SE=0.002, p<0.001). Conclusion: Local RNFL-S is significantly correlated with VFS, highlighting its potential as a biomarker for focal glaucoma damage.
- 24 December 2025
- Published by BMJ in British Journal of Ophthalmology
- Vol. 110 (7) , 793-801
Open AccessThe retinal nerve fibre layer thickness slope: a localised biomarker of the structure–function relationship in early glaucoma
Background/aims: To describe the relationship between the novel biomarker retinal nerve fibre layer thickness slope (RNFL-S), and visual field sensitivity (VFS) in healthy and early glaucoma eyes. Methods: This prospective cross-sectional study of 50 early glaucoma and 139 healthy eyes analysed RNFL-S locally along retinal nerve fibre trajectories that were automatically traced and centred on 24–2 and 10–2 visual field (VF) test points. Corresponding virtual B-scans were extracted from stitched wide-field polarisation-sensitive optical coherence tomography images. A linear mixed-effects model (LMM) assessed the association between VFS and the factors RNFL-S, glaucoma status and age. Results: The average VF mean deviation was −3.11±1.51 dB in glaucoma (mean age: 63.0±9.3 years) and −0.36±1.10 dB in healthy eyes (mean age: 47.9±16.3 years). In healthy subjects, VFS and the corresponding RNFL-S were 31.8±2.4 dB (12.5±2.9 µm/mm) in the upper hemisphere and 32.4±2.2 dB (12.5±2.5 µm/mm) in the lower hemisphere. In glaucoma patients, these values were significantly lower: 27.5±7.0 dB (8.6 ± 3.9 µm/mm, p<0.001) in the upper hemisphere and 30.1±4.3 dB (10.5±3.3 µm/mm, p<0.001) in the lower hemisphere. Significant point-wise Spearman correlation coefficients (up to r=0.61) were observed, particularly in the upper VF hemisphere within the central 10° and close to the optic nerve head. The LMM showed a positive association between VFS and RNFL-S (β=0.0415, SE=0.0023, p<0.001, R²=0.1885). Glaucoma was significantly associated with lower VFS (β=−2.468, SE=0.069, p<0.001). Age negatively correlated with VFS (β=−0.048, SE=0.002, p<0.001). Conclusion: Local RNFL-S is significantly correlated with VFS, highlighting its potential as a biomarker for focal glaucoma damage.
- Open Access
- 11 November 2024
- Published by Springer Nature in Research Square
Correlation between human expert macular fluid height assessment and fluid volume quantification in neovascular age-related macular degeneration
To investigate the association of manually measured retinal fluid by a human expert with AI-quantified retinal fluid volumes and to explore disease activity indicated by fluid volume distributions in neovascular age-related macular degeneration (nAMD) using an approved AI-based algorithm. This is a retrospective study analyzing baseline OCT data of patients with nAMD from multicenter study data. Manually measured maximum macular fluid heights vertically on B-scans in the central millimeter (CMM) for intraretinal fluid (IRF), subretinal fluid (SRF), and pigment epithelial detachment (PED) acquired from expert were associated with vertical fluid heights and three-dimensional volumes obtained by automated quantification using an AI-based tool (RetInSight Fluid Monitor Version 2). Out of 890 patients/eyes, we identified IRF in the CMM both manually and automatically in 328 eyes, SRF in 502 eyes, and PED in 705 eyes. The correlation between manual height and AI-based height was strong for IRF (r = 0.87) and PED (r = 0.91), and moderate for SRF (r = 0.67). Manual height vs. AI-based volume correlation in the CMM was strong for IRF (r = 0.76), and PED (r = 0.87) and moderate for SRF (r = 0.55). The correlation worsened when associating total fluid volumes in the central 6mm with manual CMM fluid height, indicating that CMM height does not represent total nAMD disease activity. AI-based fluid segmentation, in contrast to conventional human expert fluid measurements, provides a more comprehensive assessment, allowing for a significantly more accurate interpretation of total nAMD disease activity.
- 11 November 2024
- Published by Springer Nature in Research Square
Open AccessCorrelation between human expert macular fluid height assessment and fluid volume quantification in neovascular age-related macular degeneration
To investigate the association of manually measured retinal fluid by a human expert with AI-quantified retinal fluid volumes and to explore disease activity indicated by fluid volume distributions in neovascular age-related macular degeneration (nAMD) using an approved AI-based algorithm. This is a retrospective study analyzing baseline OCT data of patients with nAMD from multicenter study data. Manually measured maximum macular fluid heights vertically on B-scans in the central millimeter (CMM) for intraretinal fluid (IRF), subretinal fluid (SRF), and pigment epithelial detachment (PED) acquired from expert were associated with vertical fluid heights and three-dimensional volumes obtained by automated quantification using an AI-based tool (RetInSight Fluid Monitor Version 2). Out of 890 patients/eyes, we identified IRF in the CMM both manually and automatically in 328 eyes, SRF in 502 eyes, and PED in 705 eyes. The correlation between manual height and AI-based height was strong for IRF (r = 0.87) and PED (r = 0.91), and moderate for SRF (r = 0.67). Manual height vs. AI-based volume correlation in the CMM was strong for IRF (r = 0.76), and PED (r = 0.87) and moderate for SRF (r = 0.55). The correlation worsened when associating total fluid volumes in the central 6mm with manual CMM fluid height, indicating that CMM height does not represent total nAMD disease activity. AI-based fluid segmentation, in contrast to conventional human expert fluid measurements, provides a more comprehensive assessment, allowing for a significantly more accurate interpretation of total nAMD disease activity.
- Open Access
- 31 August 2024
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 269, 172-180
Introduction and Validation of Low-Cost Ocular Biometry in Healthy and Cataractous Eyes Using a Thermally Tunable Swept-Source Laser
- 31 August 2024
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 269, 172-180
Open AccessIntroduction and Validation of Low-Cost Ocular Biometry in Healthy and Cataractous Eyes Using a Thermally Tunable Swept-Source Laser
- Open Access
- 29 March 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (7) , 1979
PRESERFLO™ Microshunt: 1-Year Results of a 25-Gauge vs. 27-Gauge Needle Tract
Background: The purpose of this study was to evaluate the effectiveness and safety of the PreserFlo™ microshunt (PMS) using a 25-Gauge vs. 27-Gauge needle tract. Methods: This is a prospective postoperative examination of 60 glaucoma eyes that received a PMS. The main outcome measures were intraocular pressure (IOP), glaucoma drug score (GDS), Kaplan–Meier success rates, complications, and secondary intervention rates. Two subgroups were formed for data comparison: 27-Gauge (27G), and 25-Gauge (25G). Success was defined as IOP < 18 mmHg together with ≥20% IOP reduction with medication allowed (qualified success = QS18) or not (full success = FS18). Results: IOP and GDS were reduced from baseline to the 1-year study visit as follows: All eyes from 23.4 ± 8.6 mmHg (3.1 ± 0.9) to 15.1 ± 5.9 mmHg (0.8 ± 1.1); 25G from 24.2 ± 7.3 mmHg (3.0 ± 0.8) to 12.7 ± 2.7 mmHg (0.5 ± 0.8); and 27G from 23.1 ± 9.2 mmHg (3.1 ± 1.0) to 16.2 ± 6.7 mmHg (0.9 ± 1.2). IOP at one year was lower in the 25G group compared to the 27G group (p = 0.035). Bleb needling was required in eight (13.3%) eyes and open bleb revisions in three (5.0%). Transient hypotony occurred in 21% and choroidal effusion in 8% of all eyes. Choroidal effusions were more frequent in the 25G group (21%) compared to the 27G group (2%, p = 0.031). One-year success rates were significantly higher in the 25G group compared to the 27G group for both QS18 (25G: 67.9% vs. 27G: 35.7%, p = 0.002) and FS18 (25G: 63.6% vs. 27G: 29.2%, p = 0.007). Conclusions: The PreserFlo microshunt is an effective and safe glaucoma surgery with a low rate of bleb revisions or needlings. We show that the 25G needle tract might be more efficient for IOP control at the cost of increased IOP-related complications compared to 27G.
- 29 March 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (7) , 1979
Open AccessPRESERFLO™ Microshunt: 1-Year Results of a 25-Gauge vs. 27-Gauge Needle Tract
Background: The purpose of this study was to evaluate the effectiveness and safety of the PreserFlo™ microshunt (PMS) using a 25-Gauge vs. 27-Gauge needle tract. Methods: This is a prospective postoperative examination of 60 glaucoma eyes that received a PMS. The main outcome measures were intraocular pressure (IOP), glaucoma drug score (GDS), Kaplan–Meier success rates, complications, and secondary intervention rates. Two subgroups were formed for data comparison: 27-Gauge (27G), and 25-Gauge (25G). Success was defined as IOP < 18 mmHg together with ≥20% IOP reduction with medication allowed (qualified success = QS18) or not (full success = FS18). Results: IOP and GDS were reduced from baseline to the 1-year study visit as follows: All eyes from 23.4 ± 8.6 mmHg (3.1 ± 0.9) to 15.1 ± 5.9 mmHg (0.8 ± 1.1); 25G from 24.2 ± 7.3 mmHg (3.0 ± 0.8) to 12.7 ± 2.7 mmHg (0.5 ± 0.8); and 27G from 23.1 ± 9.2 mmHg (3.1 ± 1.0) to 16.2 ± 6.7 mmHg (0.9 ± 1.2). IOP at one year was lower in the 25G group compared to the 27G group (p = 0.035). Bleb needling was required in eight (13.3%) eyes and open bleb revisions in three (5.0%). Transient hypotony occurred in 21% and choroidal effusion in 8% of all eyes. Choroidal effusions were more frequent in the 25G group (21%) compared to the 27G group (2%, p = 0.031). One-year success rates were significantly higher in the 25G group compared to the 27G group for both QS18 (25G: 67.9% vs. 27G: 35.7%, p = 0.002) and FS18 (25G: 63.6% vs. 27G: 29.2%, p = 0.007). Conclusions: The PreserFlo microshunt is an effective and safe glaucoma surgery with a low rate of bleb revisions or needlings. We show that the 25G needle tract might be more efficient for IOP control at the cost of increased IOP-related complications compared to 27G.
- 11 August 2022
- Published by Taylor & Francis in Quality Engineering
- Vol. 34 (4) , 426-445
Statistical engineering – Part 1: Past and present
After more than a decade since the introduction of Statistical Engineering by Roger Hoerl and Ronald Snee, a group of leading applied statisticians from academia, industry, and government were invited to discuss their perspectives on progress made, the current status of this important movement, and what future Statistical Engineering holds on the path forward in a series of two panel discussion papers. In this first article, the invited panelists focus their discussion on the past and present of Statistical Engineering. They discuss notable advances and current obstacles to progress. They also consider the unique value added by Statistical Engineering, and the possible addition of decision making to the body of knowledge. The format of the article consists of the posed questions from the moderators, a summary of key ideas from all the panelists, and then the individual detailed answers. The goal of this series of articles is to inspire statisticians to consider their possible role to advance the adoption of Statistical Engineering to solve important problems.
- 11 August 2022
- Published by Taylor & Francis in Quality Engineering
- Vol. 34 (4) , 426-445
Statistical engineering – Part 1: Past and present
After more than a decade since the introduction of Statistical Engineering by Roger Hoerl and Ronald Snee, a group of leading applied statisticians from academia, industry, and government were invited to discuss their perspectives on progress made, the current status of this important movement, and what future Statistical Engineering holds on the path forward in a series of two panel discussion papers. In this first article, the invited panelists focus their discussion on the past and present of Statistical Engineering. They discuss notable advances and current obstacles to progress. They also consider the unique value added by Statistical Engineering, and the possible addition of decision making to the body of knowledge. The format of the article consists of the posed questions from the moderators, a summary of key ideas from all the panelists, and then the individual detailed answers. The goal of this series of articles is to inspire statisticians to consider their possible role to advance the adoption of Statistical Engineering to solve important problems.
- 7 March 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC11948, PC119480H
Analysis of retinal nerve fiber tissue deformation in-vivo using temporal phase contrast OCT
We introduce a new method, temporal phase contrast (TPC) OCT, to measure sub-micron tissue motion in-vivo in the retina over an extended timeframe, i.e. over several seconds. The analysis is based on the calculation of the phase differences between an initial reference B-scan and each of the subsequent B-scans. In this study, retinal nerve fiber (RNF) tissue deformations induced by retinal vessels pulsating with the heartbeat were investigated in healthy volunteers. We show reproducible results of tissue expansion enabling to quantify the extent of the deformation and access the delay between expansion near the arteries and the veins.
- 7 March 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC11948, PC119480H
Analysis of retinal nerve fiber tissue deformation in-vivo using temporal phase contrast OCT
We introduce a new method, temporal phase contrast (TPC) OCT, to measure sub-micron tissue motion in-vivo in the retina over an extended timeframe, i.e. over several seconds. The analysis is based on the calculation of the phase differences between an initial reference B-scan and each of the subsequent B-scans. In this study, retinal nerve fiber (RNF) tissue deformations induced by retinal vessels pulsating with the heartbeat were investigated in healthy volunteers. We show reproducible results of tissue expansion enabling to quantify the extent of the deformation and access the delay between expansion near the arteries and the veins.
- 1 July 2016
- Published by Taylor & Francis in Journal of Quality Technology
- Vol. 48 (3) , 284-296
A Study of Missing Data Imputation in Predictive Modeling of a Wood-Composite Manufacturing Process
Problem: Real-time process data and destructive test data were collected and merged from a wood-composite manufacturer in the southeastern US for the purpose of developing real-time predictive models for strength properties of manufactured particleboard. Sensor malfunction and other real-time data problems lead to null fields in the company's data warehouse, resulting in information loss. Many manufacturers attempt to build accurate predictive models excluding entire records with null fields or use summary statistics such as the average or median in place of the null field. However, predictive-model errors in validation may be higher in the presence of information loss and may misguide the production process. Approach: This paper summarizes an application of missing-data imputation methods in predictive modeling of a wood-composite manufacturing process. Variable selection was applied prior to imputing missing data. Two missing data-imputation methods were selected after comparing six possible methods. Predictive models of imputed data were developed using partial least squares regression (PLSR) and were compared with models developed from nonimputed data. Results: Maximum–likelihood-based imputation using the expectation-maximization (EM) algorithm and multiple imputation (MI) using Markov Chain Monte Carlo (MCMC) simulation achieved lower root mean-square error of prediction results than imputation based on the mean/median substitution, last-observation-carried-forward (LOCF), or a “hot-deck” method using single imputation. Predictive models based on the imputed dataset generated more precise prediction results than models based on nonimputed datasets. Outcomes of the study included avoiding rework and scrap when model predictions alerted of an imminent strength failure and minor reductions were made in resin input set points. Senior management of the company indicated that a savings occurred as a result of the study from lower resin usage (the second highest cost component of manufactured product).
- 1 July 2016
- Published by Taylor & Francis in Journal of Quality Technology
- Vol. 48 (3) , 284-296
A Study of Missing Data Imputation in Predictive Modeling of a Wood-Composite Manufacturing Process
Problem: Real-time process data and destructive test data were collected and merged from a wood-composite manufacturer in the southeastern US for the purpose of developing real-time predictive models for strength properties of manufactured particleboard. Sensor malfunction and other real-time data problems lead to null fields in the company's data warehouse, resulting in information loss. Many manufacturers attempt to build accurate predictive models excluding entire records with null fields or use summary statistics such as the average or median in place of the null field. However, predictive-model errors in validation may be higher in the presence of information loss and may misguide the production process. Approach: This paper summarizes an application of missing-data imputation methods in predictive modeling of a wood-composite manufacturing process. Variable selection was applied prior to imputing missing data. Two missing data-imputation methods were selected after comparing six possible methods. Predictive models of imputed data were developed using partial least squares regression (PLSR) and were compared with models developed from nonimputed data. Results: Maximum–likelihood-based imputation using the expectation-maximization (EM) algorithm and multiple imputation (MI) using Markov Chain Monte Carlo (MCMC) simulation achieved lower root mean-square error of prediction results than imputation based on the mean/median substitution, last-observation-carried-forward (LOCF), or a “hot-deck” method using single imputation. Predictive models based on the imputed dataset generated more precise prediction results than models based on nonimputed datasets. Outcomes of the study included avoiding rework and scrap when model predictions alerted of an imminent strength failure and minor reductions were made in resin input set points. Senior management of the company indicated that a savings occurred as a result of the study from lower resin usage (the second highest cost component of manufactured product).
- 19 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 62 (12) , 2850-2859
Dual-Energy X-Ray Absorptiometry for Measurement of Phalangeal Bone Mineral Density on a Slot-Scanning Digital Radiography System
Objective: In this paper, we assess the feasibility of using two detectors in a slot-scanning digital radiography system to acquire images for measuring bone mineral density (BMD) of the middle phalanx of the middle finger using dual-energy X-ray absorptiometry (DXA). Methods: Simulations were used to evaluate the spectral separation of the low- and high-energy spectra and detective quantum efficiency was used for assessing image quality. Scan parameters were chosen to optimize spectral separation, image quality, and radiation dose. We introduce the measurement of volumetric BMD (vBMD) using basis material decomposition. We assess the accuracy of our methods by comparing measurements taken using bone images against reference data derived from subsequent incineration of the bones. In vivo scans were conducted to evaluate the system precision (repeatability) and agreement with a clinical densitometer. Results: Average errors for bone mineral content (BMC), areal BMD (aBMD), and vBMD were 4.85%, 5.49%, and 12.77%, respectively. Our system had good agreement with a clinical densitometer based on concordance correlation coefficient values of 0.92 and 0.98 for aBMD and BMC, respectively. Precision studies yielded coefficient of variation (CV) values of 1.35% for aBMD, 1.48% for BMC, and 1.80% for vBMD. The CV values of all measurements were within 2%, indicating that the methods have clinically acceptable precision. Conclusion: We conclude that our techniques yield bone measurements with high accuracy, clinically acceptable precision, and good agreement with a clinical densitometer. Significance: We have shown the clinical potential of phalangeal DXA measurements of aBMD and vBMD on a slot-scanning digital radiography system.
- 19 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 62 (12) , 2850-2859
Dual-Energy X-Ray Absorptiometry for Measurement of Phalangeal Bone Mineral Density on a Slot-Scanning Digital Radiography System
Objective: In this paper, we assess the feasibility of using two detectors in a slot-scanning digital radiography system to acquire images for measuring bone mineral density (BMD) of the middle phalanx of the middle finger using dual-energy X-ray absorptiometry (DXA). Methods: Simulations were used to evaluate the spectral separation of the low- and high-energy spectra and detective quantum efficiency was used for assessing image quality. Scan parameters were chosen to optimize spectral separation, image quality, and radiation dose. We introduce the measurement of volumetric BMD (vBMD) using basis material decomposition. We assess the accuracy of our methods by comparing measurements taken using bone images against reference data derived from subsequent incineration of the bones. In vivo scans were conducted to evaluate the system precision (repeatability) and agreement with a clinical densitometer. Results: Average errors for bone mineral content (BMC), areal BMD (aBMD), and vBMD were 4.85%, 5.49%, and 12.77%, respectively. Our system had good agreement with a clinical densitometer based on concordance correlation coefficient values of 0.92 and 0.98 for aBMD and BMC, respectively. Precision studies yielded coefficient of variation (CV) values of 1.35% for aBMD, 1.48% for BMC, and 1.80% for vBMD. The CV values of all measurements were within 2%, indicating that the methods have clinically acceptable precision. Conclusion: We conclude that our techniques yield bone measurements with high accuracy, clinically acceptable precision, and good agreement with a clinical densitometer. Significance: We have shown the clinical potential of phalangeal DXA measurements of aBMD and vBMD on a slot-scanning digital radiography system.