Joyce E. Coppock
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Joyce E. Coppock has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
B. E. Kane
Laboratory for Physical Sciences , 8050 Greenmead Dr.
2 shared publications- B. E. Kane
Laboratory for Physical Sciences 1 , 8050 Greenmead Dr., College Park, Maryland 20740
2 shared publications - James R. Anderson
Department of Biostatistics College of Public Health University of Nebraska Medical Center Omaha Nebraska USA
1 shared publication Quinn Waxter
Laboratory for Physical Sciences, 8050 Greenmead Dr., College Park, Maryland20740, United States
1 shared publicationRobert Wolle
Laboratory for Physical Sciences, 8050 Greenmead Dr., College Park, Maryland20740, United States
1 shared publication- Sarah Westgate
University of Maryland 3 , College Park, Maryland 20742
1 shared publication
Latest Publications
- Open Access
- 19 November 2026
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 130 (48) , 16800-16809
Carbon Encapsulation of Levitated Au Nanoparticles
We investigate the formation of a barrier to evaporation that develops when levitated nanoscale Au nanoparticles are exposed to pulses of 532 nm laser radiation in a high vacuum (pressure p = 10–8–10–7 Torr) environment. Our data are derived from precision measurements of the charge-to-mass ratio (Q/M) of ∼200 nm-diameter Au particles confined in a quadrupole ion trap. We characterize the development of the barrier over time as the particle is repeatedly heated with laser pulses. We determine the impact of variation of the length of the interval between pulses and the impact of exposure to several gases added to the vacuum chamber. We observe a slow increase in the mass of the particles upon prolonged exposure to the vacuum, which we attribute to the growth of a barrier layer. For particles that have acquired a barrier during exposure to CO, we observe a rapid decrease in their mass upon subsequent exposure to O2. These findings are consistent with the growth and subsequent oxidation of a graphene layer on the Au that forms the barrier to evaporation. However, we have not found that the rate of formation of the barrier depends on the pressure of carbon-containing gases (CO, C2H4, CO2) that we have added to the chamber. We hypothesize that a rare surface state on the solid Au particle catalyzes the reaction that introduces C to the particle. Repeated laser-pulse heating is necessary─either to enable diffusion away from this state or to create fresh states that allow continued C uptake─to facilitate the growth of the surface graphene layer.
- 19 November 2026
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 130 (48) , 16800-16809
Open AccessCarbon Encapsulation of Levitated Au Nanoparticles
We investigate the formation of a barrier to evaporation that develops when levitated nanoscale Au nanoparticles are exposed to pulses of 532 nm laser radiation in a high vacuum (pressure p = 10–8–10–7 Torr) environment. Our data are derived from precision measurements of the charge-to-mass ratio (Q/M) of ∼200 nm-diameter Au particles confined in a quadrupole ion trap. We characterize the development of the barrier over time as the particle is repeatedly heated with laser pulses. We determine the impact of variation of the length of the interval between pulses and the impact of exposure to several gases added to the vacuum chamber. We observe a slow increase in the mass of the particles upon prolonged exposure to the vacuum, which we attribute to the growth of a barrier layer. For particles that have acquired a barrier during exposure to CO, we observe a rapid decrease in their mass upon subsequent exposure to O2. These findings are consistent with the growth and subsequent oxidation of a graphene layer on the Au that forms the barrier to evaporation. However, we have not found that the rate of formation of the barrier depends on the pressure of carbon-containing gases (CO, C2H4, CO2) that we have added to the chamber. We hypothesize that a rare surface state on the solid Au particle catalyzes the reaction that introduces C to the particle. Repeated laser-pulse heating is necessary─either to enable diffusion away from this state or to create fresh states that allow continued C uptake─to facilitate the growth of the surface graphene layer.
- Open Access
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Collection, characterization, and precision measurement of levitated charged nanoparticles
We describe apparatus and experimental procedures for high stability precision measurements of levitated nanoscale particles confined in an ion trap in high vacuum. We discuss methods for particle generation and collection using electrospray emission, rapid characterization by direct imaging of thermal motion, and transfer of the particle from the trap where it is collected to a separate analysis trap in order to achieve better vacuum and lower noise. In the analysis trap at high vacuum (pressure p ≃ 10−8 Torr), we employ thermostatic control of the trapped particle oscillation amplitudes, allowing long-term, precision measurements of oscillation frequencies, from which the charge to mass ratio (Q/M) can be deduced. Under these conditions, we achieve Q/M measurement precision approaching 10−5. This sensitivity will enable, for example, investigations of the surface chemistry of μm-scale levitated materials in ultra-high vacuum environments.
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Open AccessCollection, characterization, and precision measurement of levitated charged nanoparticles
We describe apparatus and experimental procedures for high stability precision measurements of levitated nanoscale particles confined in an ion trap in high vacuum. We discuss methods for particle generation and collection using electrospray emission, rapid characterization by direct imaging of thermal motion, and transfer of the particle from the trap where it is collected to a separate analysis trap in order to achieve better vacuum and lower noise. In the analysis trap at high vacuum (pressure p ≃ 10−8 Torr), we employ thermostatic control of the trapped particle oscillation amplitudes, allowing long-term, precision measurements of oscillation frequencies, from which the charge to mass ratio (Q/M) can be deduced. Under these conditions, we achieve Q/M measurement precision approaching 10−5. This sensitivity will enable, for example, investigations of the surface chemistry of μm-scale levitated materials in ultra-high vacuum environments.
- Open Access
- 2 December 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (23)
Focused deposition of levitated nanoscale Au droplets
We describe a method for depositing nanoscale liquid Au droplets, initially levitated in an ion trap in high vacuum, onto a remote substrate. A levitated Au nanosphere is melted, expelled from the trap, and maintained in the molten state, with a laser directed along the droplet trajectory, until it reaches the substrate and rapidly solidifies. During transit, the charged droplets are focused to a small region of the substrate with an electrostatic lens. After deposition, the substrate is removed from the vacuum chamber and imaged and analyzed by techniques such as electron microscopy and energy dispersive spectroscopy. Over 90% of launched particles are deposited on the substrate, and when the lens is focused, particles land in a region of diameter 120 μm after traversing a distance of 236 mm. Our technique is of value for analysis of materials prepared or processed while levitated that can be melted. Also, Au droplets may be useful as tracers for future experiments involving smaller projectiles or oriented solids.
- 2 December 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (23)
Open AccessFocused deposition of levitated nanoscale Au droplets
We describe a method for depositing nanoscale liquid Au droplets, initially levitated in an ion trap in high vacuum, onto a remote substrate. A levitated Au nanosphere is melted, expelled from the trap, and maintained in the molten state, with a laser directed along the droplet trajectory, until it reaches the substrate and rapidly solidifies. During transit, the charged droplets are focused to a small region of the substrate with an electrostatic lens. After deposition, the substrate is removed from the vacuum chamber and imaged and analyzed by techniques such as electron microscopy and energy dispersive spectroscopy. Over 90% of launched particles are deposited on the substrate, and when the lens is focused, particles land in a region of diameter 120 μm after traversing a distance of 236 mm. Our technique is of value for analysis of materials prepared or processed while levitated that can be melted. Also, Au droplets may be useful as tracers for future experiments involving smaller projectiles or oriented solids.
- Open Access
- 14 October 2022
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 126 (42) , 17990-17996
Observation of Undercooling in a Levitated Nanoscale Liquid Au Droplet
- 14 October 2022
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 126 (42) , 17990-17996
Open AccessObservation of Undercooling in a Levitated Nanoscale Liquid Au Droplet
- 10 March 2016
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 119 (10) , 105102
The microwave Hall effect measured using a waveguide tee
This paper describes a simple microwave apparatus to measure the Hall effect in semiconductor wafers. The advantage of this technique is that it does not require contacts on the sample or the use of a resonant cavity. Our method consists of placing the semiconductor wafer into a slot cut in an X-band (8–12 GHz) waveguide series tee, injecting microwave power into the two opposite arms of the tee, and measuring the microwave output at the third arm. A magnetic field applied perpendicular to the wafer gives a microwave Hall signal that is linear in the magnetic field and which reverses phase when the magnetic field is reversed. The microwave Hall signal is proportional to the semiconductor mobility, which we compare for calibration purposes with d.c. mobility measurements obtained using the van der Pauw method. We obtain the resistivity by measuring the microwave reflection coefficient of the sample. This paper presents data for silicon and germanium samples doped with boron or phosphorus. The measured mobilities ranged from 270 to 3000 cm2/(V s).
- 10 March 2016
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 119 (10) , 105102
The microwave Hall effect measured using a waveguide tee
This paper describes a simple microwave apparatus to measure the Hall effect in semiconductor wafers. The advantage of this technique is that it does not require contacts on the sample or the use of a resonant cavity. Our method consists of placing the semiconductor wafer into a slot cut in an X-band (8–12 GHz) waveguide series tee, injecting microwave power into the two opposite arms of the tee, and measuring the microwave output at the third arm. A magnetic field applied perpendicular to the wafer gives a microwave Hall signal that is linear in the magnetic field and which reverses phase when the magnetic field is reversed. The microwave Hall signal is proportional to the semiconductor mobility, which we compare for calibration purposes with d.c. mobility measurements obtained using the van der Pauw method. We obtain the resistivity by measuring the microwave reflection coefficient of the sample. This paper presents data for silicon and germanium samples doped with boron or phosphorus. The measured mobilities ranged from 270 to 3000 cm2/(V s).