Daniel Tordjman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Daniel Tordjman has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Shai Factor
Division of Orthopaedic Surgery, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
5 shared publications - Franck Atlan
Tel Aviv Medical Center, Department of Orthopedic Surgery, Faculty of Medicine, Tel Aviv University, Weizmann St 6, Tel Aviv-Yafo 6423906, Israel
4 shared publications - Gilad Eisenberg
Hand Surgery Unit, Division of Orthopedics, Tel Aviv Sourasky Medical Center, Affiliated to the Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
3 shared publications - Tamir Pritsch
Tel Aviv Medical Center, Department of Orthopedic Surgery, Faculty of Medicine, Tel Aviv University, Weizmann St 6, Tel Aviv-Yafo 6423906, Israel
3 shared publications - Yishai Rosenblatt
Tel Aviv Medical Center, Department of Orthopedic Surgery, Faculty of Medicine, Tel Aviv University, Weizmann St 6, Tel Aviv-Yafo 6423906, Israel
3 shared publications E. Masmejean
University of Paris, 15, rue de l'Ecole de Médecine, 75006 Paris, France; Hand, Upper Limb & Peripheral Nerve Surgery Service, Georges-Pompidou European Hospital (HEGP), 20, rue Leblanc, 75015 Paris, France; Research Unit - Clinique Blomet, 136 bis, rue Blomet 75015 Paris, France
2 shared publications
Latest Publications
- Open Access
- 21 September 2024
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 14 (9) , 1006
Monobloc vs. Modular Radial-Head Arthroplasty for Complex Elbow Trauma: Long-Term Follow-Up and Comparative Evaluation
Introduction: Mason Type 3 radial-head fractures are typically treated with open reduction and internal fixation (ORIF) or radial-head arthroplasty (RHA). Prosthetic options include traditional monobloc implants and newer modular implants designed to match patient anatomy. While short- and medium-term outcomes of metallic RHA are generally favorable, this study aims to compare the long-term outcomes of patients treated with monobloc versus modular implants. Methods: The medical records of all the patients who underwent RHA at a level I trauma center between 2000 and 2011 were retrospectively reviewed. Patients who were available for follow-up were invited for reassessment, which included physical examination, questionnaires for the assessment of elbow pain and function, and follow-up radiographs. Results: Out of 35 patients who had RHA, 13 (37%) had a monobloc prosthesis and 22 (63%) had a modular prosthesis. Out of the patients that could be traced, 4 patients from the monobloc group and 10 patients from the modular group agreed to participate in the study. The mean follow-up time was 15 years in the monobloc group and 12.4 years in the modular group. Patients in the modular group demonstrated superior functional outcomes compared to the monobloc group, with statistically significant improvements in MEPS and DASH scores and a non-significant trend towards better ASES scores and VAS scores. Physical examination revealed a decline in function in the operated arm for both groups, with statistically significant differences favoring the modular group in elbow flexion and extension. Radiographic analysis showed varying degrees of implant loosening, with the modular group exhibiting less loosening compared to the monobloc group. Mild degenerative changes and heterotopic ossification were also observed, predominantly in the modular group. Conclusions: The results suggest that modular implants offer superior functional outcomes compared to monobloc implants. The modular group showed statistically significant improvements in elbow flexion and extension. These findings indicate that modular implants may be a more favorable option for enhancing patient outcomes. Further research with larger sample sizes is recommended to confirm these trends and to better understand the long-term benefits of modular implants.
- 21 September 2024
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 14 (9) , 1006
Open AccessMonobloc vs. Modular Radial-Head Arthroplasty for Complex Elbow Trauma: Long-Term Follow-Up and Comparative Evaluation
Introduction: Mason Type 3 radial-head fractures are typically treated with open reduction and internal fixation (ORIF) or radial-head arthroplasty (RHA). Prosthetic options include traditional monobloc implants and newer modular implants designed to match patient anatomy. While short- and medium-term outcomes of metallic RHA are generally favorable, this study aims to compare the long-term outcomes of patients treated with monobloc versus modular implants. Methods: The medical records of all the patients who underwent RHA at a level I trauma center between 2000 and 2011 were retrospectively reviewed. Patients who were available for follow-up were invited for reassessment, which included physical examination, questionnaires for the assessment of elbow pain and function, and follow-up radiographs. Results: Out of 35 patients who had RHA, 13 (37%) had a monobloc prosthesis and 22 (63%) had a modular prosthesis. Out of the patients that could be traced, 4 patients from the monobloc group and 10 patients from the modular group agreed to participate in the study. The mean follow-up time was 15 years in the monobloc group and 12.4 years in the modular group. Patients in the modular group demonstrated superior functional outcomes compared to the monobloc group, with statistically significant improvements in MEPS and DASH scores and a non-significant trend towards better ASES scores and VAS scores. Physical examination revealed a decline in function in the operated arm for both groups, with statistically significant differences favoring the modular group in elbow flexion and extension. Radiographic analysis showed varying degrees of implant loosening, with the modular group exhibiting less loosening compared to the monobloc group. Mild degenerative changes and heterotopic ossification were also observed, predominantly in the modular group. Conclusions: The results suggest that modular implants offer superior functional outcomes compared to monobloc implants. The modular group showed statistically significant improvements in elbow flexion and extension. These findings indicate that modular implants may be a more favorable option for enhancing patient outcomes. Further research with larger sample sizes is recommended to confirm these trends and to better understand the long-term benefits of modular implants.
- Open Access
- 25 December 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (1) , 121
Failure Rate and Early Complications of Thumb Carpometacarpal Joint Replacement—A Multicenter Retrospective Study of Two Modern Implant Designs
Joint replacement arthroplasty for the treatment of thumb osteoarthritis is gaining popularity as recent studies have demonstrated better pinch and grip strength and faster rehabilitation. Our aim was to identify early complications in modern implant designs using a multicenter study. A total of 381 patients who underwent thumb carpometacarpal replacement surgery in six participating hospitals were enrolled. The complications included were fractures, dislocations, infections, tendon and nerve injuries, and complex regional pain syndrome. Major complications were defined as a failure to implant the prosthesis, revision surgery to remove the implant, and any other need for further surgical intervention. The secondary outcomes were any other complications treated non-surgically and the timing of the complications. Eleven procedures failed, and these patients were treated with trapeziectomies. Twelve other patients required repeat surgical interventions. Minor adverse events occurred in 25.4% of the cases, and transient irritation of the superficial radial nerve and De Quervain tendinopathy were the most prevalent complications. Although this cohort depicted the learning curves of multiple surgeons, our study demonstrated low short-term failure rates. An inability to achieve primary stability of the cup in the trapezium was the leading cause of failure. Dislocations and other major complications with modern implants were very few.
- 25 December 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (1) , 121
Open AccessFailure Rate and Early Complications of Thumb Carpometacarpal Joint Replacement—A Multicenter Retrospective Study of Two Modern Implant Designs
Joint replacement arthroplasty for the treatment of thumb osteoarthritis is gaining popularity as recent studies have demonstrated better pinch and grip strength and faster rehabilitation. Our aim was to identify early complications in modern implant designs using a multicenter study. A total of 381 patients who underwent thumb carpometacarpal replacement surgery in six participating hospitals were enrolled. The complications included were fractures, dislocations, infections, tendon and nerve injuries, and complex regional pain syndrome. Major complications were defined as a failure to implant the prosthesis, revision surgery to remove the implant, and any other need for further surgical intervention. The secondary outcomes were any other complications treated non-surgically and the timing of the complications. Eleven procedures failed, and these patients were treated with trapeziectomies. Twelve other patients required repeat surgical interventions. Minor adverse events occurred in 25.4% of the cases, and transient irritation of the superficial radial nerve and De Quervain tendinopathy were the most prevalent complications. Although this cohort depicted the learning curves of multiple surgeons, our study demonstrated low short-term failure rates. An inability to achieve primary stability of the cup in the trapezium was the leading cause of failure. Dislocations and other major complications with modern implants were very few.
- Open Access
- 9 August 2023
- Published by MDPI AG in Surgical Techniques Development
- Vol. 12 (3) , 135-144
Predictive Factors for Union Time in Adult Diaphyseal Forearm Fractures
Purpose: Although open reduction and internal fixation (ORIF) by plating are the treatment of choice for diaphyseal fractures of the forearm, delayed union and non-union remain as existing complications. This study aimed to analyze predictive factors for the union time in diaphyseal fractures of the forearm. Methods: A retrospective study was conducted on all adult patients with diaphyseal forearm fractures who underwent surgical treatment with plate fixation between 2007 and 2016 at a tertiary care referral center. The patients were divided into two groups based on their union times: ≤3 months or >3 months. They were then compared for demographics, fracture pattern and characteristics, associated injuries, type of fixation, and quality of postoperative reduction. Results: Eighty-six diaphyseal forearm bone fractures (radius, ulna, or both) were observed in 55 adults. Out of these fractures, 55 (65.1%) achieved union within ≤3 months, 26 (30.3%) took more than 3 months to achieve union, and 4 (4.6%) resulted in nonunion. The use of a locking plate in open reduction and internal fixation of diaphyseal forearm fractures significantly increased the likelihood of union within ≤3 months (p = 0.043). The parameter of gap width at the fracture site, as observed on postoperative X-rays, showed a qualitative and quantitative correlation with union time (p = 0.028). Conclusion: The use of a locking plate, combined with reducing the gap width at the fracture site after reduction during open reduction and internal fixation (ORIF) of diaphyseal forearm fractures, is significantly correlated with an increased likelihood of achieving bone union within 3 months.
- 9 August 2023
- Published by MDPI AG in Surgical Techniques Development
- Vol. 12 (3) , 135-144
Open AccessPredictive Factors for Union Time in Adult Diaphyseal Forearm Fractures
Purpose: Although open reduction and internal fixation (ORIF) by plating are the treatment of choice for diaphyseal fractures of the forearm, delayed union and non-union remain as existing complications. This study aimed to analyze predictive factors for the union time in diaphyseal fractures of the forearm. Methods: A retrospective study was conducted on all adult patients with diaphyseal forearm fractures who underwent surgical treatment with plate fixation between 2007 and 2016 at a tertiary care referral center. The patients were divided into two groups based on their union times: ≤3 months or >3 months. They were then compared for demographics, fracture pattern and characteristics, associated injuries, type of fixation, and quality of postoperative reduction. Results: Eighty-six diaphyseal forearm bone fractures (radius, ulna, or both) were observed in 55 adults. Out of these fractures, 55 (65.1%) achieved union within ≤3 months, 26 (30.3%) took more than 3 months to achieve union, and 4 (4.6%) resulted in nonunion. The use of a locking plate in open reduction and internal fixation of diaphyseal forearm fractures significantly increased the likelihood of union within ≤3 months (p = 0.043). The parameter of gap width at the fracture site, as observed on postoperative X-rays, showed a qualitative and quantitative correlation with union time (p = 0.028). Conclusion: The use of a locking plate, combined with reducing the gap width at the fracture site after reduction during open reduction and internal fixation (ORIF) of diaphyseal forearm fractures, is significantly correlated with an increased likelihood of achieving bone union within 3 months.
- 28 July 2023
- Published by Georg Thieme Verlag KG in Journal of Wrist Surgery
- Vol. 13 (02) , 151-157
Volar Locking Plating of Extra-articular Distal Radius Fracture: A Retrospective Clinical Study Comparing Locking Screws versus Smooth Locking Pegs
Background Open reduction and internal fixation of distal radius fractures is one of the most common procedures performed in wrist surgery. The use of volar locking plate has gained increasing interest in the past decade. Epiphyseal fixation can be done either with locking screws or smooth locking pegs, with no evidence supporting the use of one rather than the other. Purpose The aim of this study is to compare the stability of distal radius fixation by volar locking plate using locking screws or smooth locking pegs. Methods Adult patients with A2–A3 AO fractures treated with a volar plate with locking screws only or smooth locking pegs only were retrospectively included. Radiographic assessment was performed to evaluate extra-articular parameters in the intraoperative postreduction and fixation period and after bony healing. Forty-seven distal radius fractures were included. Results Twenty-four fractures had fixation with locking screws and 23 had fixation with smooth locking pegs. For both groups, all radiographic parameters measured showed a statistically significant difference between the intraoperative postreduction and fixation period and the remote postoperative period after union of the fracture (p < 0.05) attesting a slight loss of reduction. Nevertheless, there were no significant differences between the groups in radiographic extra-articular parameters. Conclusion This clinical study shows that there is no difference in stability fixation between locking screws or smooth locking pegs in A2–A3 distal radius fractures. Clinical Relevance The use of smooth locking pegs only for epiphyseal fixation appears to be safe in volar plating of A2–A3 distal radius fractures in adult patients and could be an alternative to locking screws. More clinical data are needed to confirm these results. Level of Evidence Level III; retrospective comparative study.
- 28 July 2023
- Published by Georg Thieme Verlag KG in Journal of Wrist Surgery
- Vol. 13 (02) , 151-157
Volar Locking Plating of Extra-articular Distal Radius Fracture: A Retrospective Clinical Study Comparing Locking Screws versus Smooth Locking Pegs
Background Open reduction and internal fixation of distal radius fractures is one of the most common procedures performed in wrist surgery. The use of volar locking plate has gained increasing interest in the past decade. Epiphyseal fixation can be done either with locking screws or smooth locking pegs, with no evidence supporting the use of one rather than the other. Purpose The aim of this study is to compare the stability of distal radius fixation by volar locking plate using locking screws or smooth locking pegs. Methods Adult patients with A2–A3 AO fractures treated with a volar plate with locking screws only or smooth locking pegs only were retrospectively included. Radiographic assessment was performed to evaluate extra-articular parameters in the intraoperative postreduction and fixation period and after bony healing. Forty-seven distal radius fractures were included. Results Twenty-four fractures had fixation with locking screws and 23 had fixation with smooth locking pegs. For both groups, all radiographic parameters measured showed a statistically significant difference between the intraoperative postreduction and fixation period and the remote postoperative period after union of the fracture (p < 0.05) attesting a slight loss of reduction. Nevertheless, there were no significant differences between the groups in radiographic extra-articular parameters. Conclusion This clinical study shows that there is no difference in stability fixation between locking screws or smooth locking pegs in A2–A3 distal radius fractures. Clinical Relevance The use of smooth locking pegs only for epiphyseal fixation appears to be safe in volar plating of A2–A3 distal radius fractures in adult patients and could be an alternative to locking screws. More clinical data are needed to confirm these results. Level of Evidence Level III; retrospective comparative study.
- Open Access
- 27 February 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (5) , 1866
The Effects of Novel Pulsed Electromagnetic Field Therapy Device on Acute Distal Radius Fractures: A Prospective, Double-Blind, Sham-Controlled, Randomized Pilot Study
Background: this pilot study aimed at determining whether the application of a novel new method of generating pulsed electromagnetic field (PEMF), the Fracture Healing Patch (FHP), accelerates the healing of acute distal radius fractures (DRF) when compared to a sham treatment. Methods: 41 patients with DRFs treated with cast immobilization were included. Patients were allocated to a PEMF group (n = 20) or a control (sham) group (n = 21). All patients were assessed with regard to functional and radiological outcomes (X-rays and CT scans) at 2, 4, 6 and 12 weeks. Results: fractures treated with active PEMF demonstrated significantly higher extent of union at 4 weeks as assessed by CT (76% vs. 58%, p = 0.02). SF12 mean physical score was significantly higher in PEMF treated group (47 vs. 36, p = 0.005). Time to cast removal was significantly shorter in PEMF treated patients, 33 ± 5.9 days in PEMF vs. 39.8 ± 7.4 days in sham group (p = 0.002). Conclusion: early addition of PEMF treatment may accelerate bone healing which could lead to a shorter cast immobilization, thus allowing an earlier return to daily life activities and work. There were no complications related to the PEMF device (FHP).
- 27 February 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (5) , 1866
Open AccessThe Effects of Novel Pulsed Electromagnetic Field Therapy Device on Acute Distal Radius Fractures: A Prospective, Double-Blind, Sham-Controlled, Randomized Pilot Study
Background: this pilot study aimed at determining whether the application of a novel new method of generating pulsed electromagnetic field (PEMF), the Fracture Healing Patch (FHP), accelerates the healing of acute distal radius fractures (DRF) when compared to a sham treatment. Methods: 41 patients with DRFs treated with cast immobilization were included. Patients were allocated to a PEMF group (n = 20) or a control (sham) group (n = 21). All patients were assessed with regard to functional and radiological outcomes (X-rays and CT scans) at 2, 4, 6 and 12 weeks. Results: fractures treated with active PEMF demonstrated significantly higher extent of union at 4 weeks as assessed by CT (76% vs. 58%, p = 0.02). SF12 mean physical score was significantly higher in PEMF treated group (47 vs. 36, p = 0.005). Time to cast removal was significantly shorter in PEMF treated patients, 33 ± 5.9 days in PEMF vs. 39.8 ± 7.4 days in sham group (p = 0.002). Conclusion: early addition of PEMF treatment may accelerate bone healing which could lead to a shorter cast immobilization, thus allowing an earlier return to daily life activities and work. There were no complications related to the PEMF device (FHP).
- 7 February 2023
- Published by Elsevier in Hand Surgery and Rehabilitation
- Vol. 42 (2) , 103-108
Neuroma-in-continuity: a review of pathophysiology and approach to the affected patient
- 7 February 2023
- Published by Elsevier in Hand Surgery and Rehabilitation
- Vol. 42 (2) , 103-108
Neuroma-in-continuity: a review of pathophysiology and approach to the affected patient
- Open Access
- 19 May 2022
- Published by EDP Sciences in SICOT-J
- Vol. 8, 17
Wrist arthroscopy for diagnosis and treatment of acute and chronic conditions
Wrist arthroscopy is a constantly evolving procedure. Allowing direct visualization and dynamic testing of intra-articular structures led to a novel approach toward traumatic and degenerative lesions based on most of the classifications routinely used in wrist surgery. The development of specific instrumentation, combined with a novel understanding of the local anatomy, progressively allowed wrist surgeons to describe more ambitious and complex surgeries. Wrist arthroscopy has become an increasingly useful tool in hand and wrist surgeons’ panoply and seems promised to have further development in the future. This paper discusses the surgical technique and the various pathologies that can be treated by arthroscopy of the wrist.
- 19 May 2022
- Published by EDP Sciences in SICOT-J
- Vol. 8, 17
Open AccessWrist arthroscopy for diagnosis and treatment of acute and chronic conditions
Wrist arthroscopy is a constantly evolving procedure. Allowing direct visualization and dynamic testing of intra-articular structures led to a novel approach toward traumatic and degenerative lesions based on most of the classifications routinely used in wrist surgery. The development of specific instrumentation, combined with a novel understanding of the local anatomy, progressively allowed wrist surgeons to describe more ambitious and complex surgeries. Wrist arthroscopy has become an increasingly useful tool in hand and wrist surgeons’ panoply and seems promised to have further development in the future. This paper discusses the surgical technique and the various pathologies that can be treated by arthroscopy of the wrist.
- 1 February 2022
- Published by Elsevier in Hand Surgery and Rehabilitation
- Vol. 41, S90-S97
Tendon transfer surgery for radial nerve palsy
- 1 February 2022
- Published by Elsevier in Hand Surgery and Rehabilitation
- Vol. 41, S90-S97
Tendon transfer surgery for radial nerve palsy
- 1 March 2018
- Published by Wolters Kluwer Health in Techniques in Hand & Upper Extremity Surgery
- Vol. 22 (1) , 19-25
Radial Shaft Convergence in Distal Radius Fractures: Diagnosis and Treatment
Radial shaft convergence in distal radius fractures is often misdiagnosed. This common deformation is often associated with a radial translation of the distal fragment. This parameter has to be corrected because of the increased risk of distal radioulnar joint instability due to detensioning of the distal interosseous membrane if there is an associated triangular fibrocartilage complex lesion. A new radiologic sign for diagnosis of proximal radius convergence during distal radius fracture is presented as well as technical tips for correction of this deformity.
- 1 March 2018
- Published by Wolters Kluwer Health in Techniques in Hand & Upper Extremity Surgery
- Vol. 22 (1) , 19-25
Radial Shaft Convergence in Distal Radius Fractures: Diagnosis and Treatment
Radial shaft convergence in distal radius fractures is often misdiagnosed. This common deformation is often associated with a radial translation of the distal fragment. This parameter has to be corrected because of the increased risk of distal radioulnar joint instability due to detensioning of the distal interosseous membrane if there is an associated triangular fibrocartilage complex lesion. A new radiologic sign for diagnosis of proximal radius convergence during distal radius fracture is presented as well as technical tips for correction of this deformity.
- 1 February 2018
- Published by Elsevier in Hand Surgery and Rehabilitation
- Vol. 37 (1) , 60-63
Accessory extensor pollicis longus: A rare tendon anomaly
- 1 February 2018
- Published by Elsevier in Hand Surgery and Rehabilitation
- Vol. 37 (1) , 60-63
Accessory extensor pollicis longus: A rare tendon anomaly