Zhijun Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhijun Lu has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Xiao Li
Institute of High Energy Physics
6 shared publications Wei Long
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
5 shared publicationsYang Liu
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
5 shared publicationsChunlin Zhang
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
4 shared publicationsJian Wu
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
4 shared publicationsXiang Li
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
4 shared publications
Latest Publications
- 25 February 2025
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 36 (4) , 1-10
Design and verification of a new multiharmonic feedback control system for CSNS-II RCS
- 25 February 2025
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 36 (4) , 1-10
Design and verification of a new multiharmonic feedback control system for CSNS-II RCS
- Open Access
- 1 December 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (12)
A low-frequency normal conducting cavity with higher-order mode damping for fourth-generation synchrotron radiation sources
The utilization of a low-frequency (<200 MHz) RF system in storage facilitates the attainment of ultra-low emittances in synchrotron light sources through on-axis injection. This paper focuses on the development of a low-frequency normal conducting (NC) cavity with higher-order mode (HOM) damping for fourth-generation synchrotron light sources. We propose a novel approach to achieve efficient HOM damping in a NC cavity by optimizing the lowest frequency HOM and implementing a beam-line absorber. Notably, unlike conventional NC cavities, the presence of a large beam tube for the beam-line absorber does not compromise the accelerating performance in a coaxial resonant cavity, enabling effective HOM damping while maintaining a high shunt impedance. Through simulations, the prototype design of a 166.6 MHz HOM-damped cavity demonstrates a fundamental mode impedance of ∼8 MΩ, with longitudinal and transverse HOM impedances below 2.0 and 50 kΩ/m, respectively.
- 1 December 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (12)
Open AccessA low-frequency normal conducting cavity with higher-order mode damping for fourth-generation synchrotron radiation sources
The utilization of a low-frequency (<200 MHz) RF system in storage facilitates the attainment of ultra-low emittances in synchrotron light sources through on-axis injection. This paper focuses on the development of a low-frequency normal conducting (NC) cavity with higher-order mode (HOM) damping for fourth-generation synchrotron light sources. We propose a novel approach to achieve efficient HOM damping in a NC cavity by optimizing the lowest frequency HOM and implementing a beam-line absorber. Notably, unlike conventional NC cavities, the presence of a large beam tube for the beam-line absorber does not compromise the accelerating performance in a coaxial resonant cavity, enabling effective HOM damping while maintaining a high shunt impedance. Through simulations, the prototype design of a 166.6 MHz HOM-damped cavity demonstrates a fundamental mode impedance of ∼8 MΩ, with longitudinal and transverse HOM impedances below 2.0 and 50 kΩ/m, respectively.
- 13 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (11) , 2388-2396
Operation Analysis of High Power Tetrode Tube for the Wideband Cavity in CSNS-II
Two high-power tetrode tubes operated in push-pull mode were employed as the final stage amplifier for the wideband magnetic alloy (MA) loaded cavity in the China Spallation Neutron Source Phase II (CSNS-II). However, the anode voltage of the tetrode tubes exhibits significant waveform distortion due to the wideband load impedance and dynamic tube characteristics. This distortion poses a threat to beam stability and results in additional power dissipation within the cavity. Consequently, it is imperative to address the compensation of higher harmonics. Prior to achieving this, a comprehensive and intricate analysis of tetrode tube operation is required, involving the simultaneous resolution of numerous variables to obtain accurate solutions for anode voltage and anode current. This paper introduces a new method for analyzing tetrode tube operation in the presence of multi-harmonics. The efficacy of this method is verified through high-power tests.
- 13 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (11) , 2388-2396
Operation Analysis of High Power Tetrode Tube for the Wideband Cavity in CSNS-II
Two high-power tetrode tubes operated in push-pull mode were employed as the final stage amplifier for the wideband magnetic alloy (MA) loaded cavity in the China Spallation Neutron Source Phase II (CSNS-II). However, the anode voltage of the tetrode tubes exhibits significant waveform distortion due to the wideband load impedance and dynamic tube characteristics. This distortion poses a threat to beam stability and results in additional power dissipation within the cavity. Consequently, it is imperative to address the compensation of higher harmonics. Prior to achieving this, a comprehensive and intricate analysis of tetrode tube operation is required, involving the simultaneous resolution of numerous variables to obtain accurate solutions for anode voltage and anode current. This paper introduces a new method for analyzing tetrode tube operation in the presence of multi-harmonics. The efficacy of this method is verified through high-power tests.
- 21 September 2023
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 34 (9) , 1-11
Development of RF windows for 650 MHz multibeam klystron
- 21 September 2023
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 34 (9) , 1-11
Development of RF windows for 650 MHz multibeam klystron
- 1 April 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (4) , 043301
Design and verification of a high-gradient and high-power 2nd harmonic cavity for the China Spallation Neutron Source upgrade project
Here, we report our recent progress in the design, fluid thermodynamics simulation, and high-power test of the2nd harmonic cavity for the China Spallation Neutron Source Phase II. A high-performance and large-size magnetic alloy (MA) core was developed as the load material for the radiofrequency cavity to achieve a high gradient of 40 kV/m. The water-cooling structure and cooling efficiency were studied and improved through numerical analysis and thermal experiments. The long-term stability of the cavity, especially the waterproofness of the MA cores with high heat load, was verified by high power tests.
- 1 April 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (4) , 043301
Design and verification of a high-gradient and high-power 2nd harmonic cavity for the China Spallation Neutron Source upgrade project
Here, we report our recent progress in the design, fluid thermodynamics simulation, and high-power test of the2nd harmonic cavity for the China Spallation Neutron Source Phase II. A high-performance and large-size magnetic alloy (MA) core was developed as the load material for the radiofrequency cavity to achieve a high gradient of 40 kV/m. The water-cooling structure and cooling efficiency were studied and improved through numerical analysis and thermal experiments. The long-term stability of the cavity, especially the waterproofness of the MA cores with high heat load, was verified by high power tests.
- 1 March 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (3) , 034708
Reflection power suppression for solid state amplifiers with combiner optimization
The application of high-power solid state amplifiers (SSAs) in accelerator facilities is increasing, and equipment failure caused by reflected power is the main risk to their long-term operation. High-power SSAs often comprise multiple power amplifier modules. Full power reflection is more likely to damage the modules in SSAs if the amplitudes of the modules are unequal. Optimization of the power combiners is an effective means for improving the stability of SSAs under high power reflection. This study analyzes the mechanisms and conditions of reflected power generation using the scattering parameters of the combiner and proposes an optimization scheme for the combiner. The simulation and experimental results show that some modules may receive reflected power as high as nearly four times the rated power of one module when the SSA meets certain conditions, which could damage the modules. The maximum reflected power can be effectively reduced and the anti-reflection ability of SSAs can be improved by optimizing the combiner parameters to suppress the maximum reflected power.
- 1 March 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (3) , 034708
Reflection power suppression for solid state amplifiers with combiner optimization
The application of high-power solid state amplifiers (SSAs) in accelerator facilities is increasing, and equipment failure caused by reflected power is the main risk to their long-term operation. High-power SSAs often comprise multiple power amplifier modules. Full power reflection is more likely to damage the modules in SSAs if the amplitudes of the modules are unequal. Optimization of the power combiners is an effective means for improving the stability of SSAs under high power reflection. This study analyzes the mechanisms and conditions of reflected power generation using the scattering parameters of the combiner and proposes an optimization scheme for the combiner. The simulation and experimental results show that some modules may receive reflected power as high as nearly four times the rated power of one module when the SSA meets certain conditions, which could damage the modules. The maximum reflected power can be effectively reduced and the anti-reflection ability of SSAs can be improved by optimizing the combiner parameters to suppress the maximum reflected power.
- Open Access
- 1 June 2022
- Published by AIP Publishing in AIP Advances
- Vol. 12 (6) , 065229
Design study and test of input coupler for 500 MHz five-cell cavity
This paper presents an optimized design and preliminary test result of a high-power input coupler. The design is motivated by five-cell Petra-type cavities operating in the Southern Advanced Photon Sources booster. We optimize the design of the high-power input coupler from the prototype, including the window geometry redesign and multipacting analysis to meet a 250 kW operation power upgrade plan. The cooling system of the coupler is redesigned to achieve a low temperature in high-power operation. Design results fulfill the five-cell cavity operation requirement. The corresponding waveguide and coaxial transition structures are developed and tested. We also describe the coupler's coupling coefficient tests and high-power test plans.
- 1 June 2022
- Published by AIP Publishing in AIP Advances
- Vol. 12 (6) , 065229
Open AccessDesign study and test of input coupler for 500 MHz five-cell cavity
This paper presents an optimized design and preliminary test result of a high-power input coupler. The design is motivated by five-cell Petra-type cavities operating in the Southern Advanced Photon Sources booster. We optimize the design of the high-power input coupler from the prototype, including the window geometry redesign and multipacting analysis to meet a 250 kW operation power upgrade plan. The cooling system of the coupler is redesigned to achieve a low temperature in high-power operation. Design results fulfill the five-cell cavity operation requirement. The corresponding waveguide and coaxial transition structures are developed and tested. We also describe the coupler's coupling coefficient tests and high-power test plans.