TSTianming Song

Tianming Song

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tianming Song has a total of 80 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design of steady shock loading with high-power laser based on Bayesian optimization

    by Yaoxiang Song, Hansheng Ye, Yuncan Ma, Tianming Song, Dongxiao Liu, Tao Xi, Zanyang Guan, Yulong Li, Xiayu Zhan, Yuqiu Gu

    High-pressure loading driven by intense lasers is a critical tool for studying material properties under extreme conditions, with wide applications in high-energy-density physics. Due to the complexity of laser–matter interactions, experimental designs typically rely on numerical simulations. The laser pulse shape in these simulations directly determines the loading characteristics, making its optimization for achieving the desired loading state a critical step. This study presents a Bayesian optimization method that is combined with hydrodynamic simulation to achieve a steady shock loading in the opaque explosive 1,3,5-triamino-2,4,6-trinitrobenzene. Numerical simulations demonstrate that the optimized laser pulse shape achieves shock front pressure fluctuations below 1%. The experimentally inferred shock velocity fluctuations remain below 3%, confirming the effectiveness of the proposed optimization approach. The main advantage of this method is its ability to achieve rapid and efficient optimization by focusing solely on input parameters and the optimization target. Its versatility can be extended to other loading forms, such as quasi-isentropic compression or double-shock loading. This machine learning optimization method offers a novel approach to laser-driven high-pressure loading experiments, with significant potential for applications in inertial confinement fusion and planetary science research.

  • Open Access

    A comparative benchmarking of optical Thomson scattering and various X-ray emission spectroscopies in nanosecond laser-produced plasmas

    by Yuxue Zhang, Chengwu Huang, Chaoxin Chen, Tianming Song, Wenqiang Yuan, LongYu Kuang, Zhu Lei, Tao Gong, Tuo Zhu, Zhiyu Zhang, et al.

    X-ray emission spectroscopy (XES) and optical Thomson scattering (OTS) are two of the most indispensable diagnostics for characterization of plasma parameters such as Te and ne in intense laser-produced plasmas (LPPs), but both can also provide weighted-average values owing to the line-of-sight, space, and time-integrated effects of optical/X-ray diagnostic techniques, which has not been thoroughly investigated. In this work, for the first time, the consistency and discrepancy between Te from XES and OTS are examined using intense lasers with a large focal spot to irradiate the smaller tip of a cylindrically symmetric titanium wire. Experimental results reveal that Te profiles derived from the two methods are approximately consistent in the earlier period of 1 ns, but exhibit different trends with increasing time. In addition, the impacts of the three integration effects on the interpretation of Te are assessed through an analysis of three types of XES methods, namely, time- and space-resolved, time-resolved but space-integrated, and time-integrated but space-resolved. Our findings indicate that the line-of-sight integration effect causes uncertainties of less than 5% in the electron temperature of corona LPPs, time-integrated XES can replace time-resolved measurements with an uncertainty of 10% for 1–2 ns laser duration, and space-integrated XES reflects the high-temperature region within 200 μm in front of the target surface, ∼10% lower than the maximum. These insights establish a foundation for the applications of experimental data in LPPs, particularly in the fields of laser-driven inertial confinement fusion and high-energy-density physics.

  • Open Access

    Effect of intense radiation on the X-ray emission spectrum of non-LTE plasmas

    by Chengwu Huang, Tuo Zhu, Yuxue Zhang, Tianming Song, Yang Zhao, Jiyan Zhang, Zhiyu Zhang, Gang Xiong, Bo Qing, Liling Li, et al.

    Low-density non–local-thermodynamic-equilibrium plasmas in intense radiation fields occur widely in inertial confinement fusion and astrophysics. Understanding the X-ray spectrum and the atomic kinetics of such plasmas is therefore of great importance. However, the creation of uniform-density nonequilibrium plasmas in intense radiation fields in the laboratory and the measurement of their spectra with high resolution are challenging tasks. Here, we present a new method to produce such a uniform aluminum plasma and explore photon-induced kinetics and relevant atomic physics by measuring its spectrum. It is observed that in the presence of an external radiation field, the satellites q, r and a–d of the He-α resonance line are greatly enhanced compared with the satellites j, k, l. Analysis of atomic kinetics reveals that this effect of intense radiation is due to competition between the photoexcitation and autoionization processes. With this effect taken into account, simulated spectra are able to reproduce the measured spectra quite well.


  • A large-dynamic-range high-time-resolved transmission grating spectrometer for the measurement of broadband x-ray spectrum

    by Tuo Zhu, Tianmin Song, Chengwu Huang, Xiaoan He, Longyu Kuang, Jin Li, Yunsong Dong, Yuxue Zhang, Yang Zhao, Jiyan Zhang, et al.

    The temporal measurement of broadband x-ray spectrum is important for the study of x-ray sources and their applications in high-energy-density plasmas. A spectrometer with a large dynamic range is required for these measurements. In this paper, a large-dynamic-range x-ray spectrometer has been designed, in which transmission grating is coupled to an x-ray streak camera with a novel varying-width slit photocathode. Compared to a traditional fixed-width slit photocathode, the dynamic range of the spectrometer has been increased by a factor of 23. The spectral range of the spectrometer is 0.12–6.2 keV, and the temporal resolution is 40 ps. This spectrometer would be a powerful diagnostic tool for hohlraum radiation characterization and radiative ablation in inertial confinement fusion.

  • Open Access

    Laser energy asymmetry-driven deflection of Au plasma jets in half-cylinder target and its interaction with CH corona plasma

    by Zhu Lei, Yuxue Zhang, Tianming Song, Qing Wang, Wenqiang Yuan, Kuan Ren, Chengwu Huang, Yang Zhao, Bo Qing, Zhiyu Zhang, et al.

    We investigate the formation of deflected gold ( Au ) jets and their interaction with plastic ( CH ) corona plasma, relevant to energy imbalances in the hohlraum for indirect drive inertial confinement fusion (ICF). Experiments and hydrodynamic simulations were performed using two laser pulses (1 ns pulse, 0.6 and 0.8 TW, respectively) with a 25 % energy and power difference on the interior of an Au cylinder shell target. X-ray and optical imaging revealed distinct deflection structures and about 15-degree deflection of the Au plasma jets. When a deflected Au jet interacted with a CH planar target representing the ICF capsule ablator, significant compression of the CH corona was observed. Radiation magnetohydrodynamic simulations closely matched the experimental results. A temperature difference of 800 eV from the laser energy imbalance caused differential expansion of the Au bubbles, driving the jet deflection. During the Au-CH interaction, self-generated magnetic fields in the Au jets were significantly enhanced at the impact point, potentially generating super-hot electrons. These findings help in understanding the impact of deflected Au jets on the CH ablator corona plasma within ICF hohlraums. Such interactions may become a key issue to address in future applications of near-vacuum hohlraums.


  • Open Access

    Measurement of 2p-3d absorption in a hot molybdenum plasma

    by Gang Xiong, Bo Qing, Zhiyu Zhang, Longfei Jing, Yang Zhao, Minxi Wei, Yimeng Yang, Lifei Hou, Chengwu Huang, Tuo Zhu, et al.

    We present measurements of the 2p-3d transition opacity of a hot molybdenum–scandium sample with nearly half-vacant molybdenum M-shell configurations. A plastic-tamped molybdenum–scandium foil sample is radiatively heated to high temperature in a compact D-shaped gold Hohlraum driven by ∼30 kJ laser energy at the SG-100 kJ laser facility. X rays transmitted through the molybdenum and scandium plasmas are diffracted by crystals and finally recorded by image plates. The electron temperatures in the sample in particular spatial and temporal zones are determined by the K-shell absorption of the scandium plasma. A combination of the IRAD3D view factor code and the MULTI hydrodynamic code is used to simulate the spatial distribution and temporal behavior of the sample temperature and density. The inferred temperature in the molybdenum plasma reaches a average of 138 ± 11 eV. A detailed configuration-accounting calculation of the n = 2–3 transition absorption of the molybdenum plasma is compared with experimental measurements and quite good agreement is found. The present measurements provide an opportunity to test opacity models for complicated M-shell configurations.


  • Open Access

    Self-consistent and precise measurement of time-dependent radiative albedo of gold based on specially symmetrical triple-cavity Hohlraum

    by Zhiyu Zhang, Yang Zhao, Xiaoying Han, Liling Li, Bo Qing, Lifei Hou, Yulong Li, YuXue Zhang, Huan Zhang, Xiangming Liu, et al.

    A self-consistent and precise method to determine the time-dependent radiative albedo, i.e., the ratio of the reemission flux to the incident flux, for an indirect-drive inertial confinement fusion Hohlraum wall material is proposed. A specially designed symmetrical triple-cavity gold Hohlraum is used to create approximately constant and near-equilibrium uniform radiation with a peak temperature of 160 eV. The incident flux at the secondary cavity waist is obtained from flux balance analysis and from the shock velocity of a standard sample. The results agree well owing to the symmetrical radiation in the secondary cavity. A self-consistent and precise time-dependent radiative albedo is deduced from the reliable reemission flux and the incident flux, and the result from the shock velocity is found to have a smaller uncertainty than that from the multi-angle flux balance analysis, and also to agree well with the result of a simulation using the HYADES opacity.


  • Open Access

    Influence of laser-induced Au-plasma plume collision on the efficiency of x-ray radiations and the energy-transport process relevant to ICF

    by Yuxue Zhang, Wenqiang Yuan, Tianming Song, Zhu Lei, Zhiyu Zhang, Bo Qing, Yang Zhao, Guohong Yang, Yukun Li, Tao Chen, et al.

    Experiments and simulations have been carried out to study the colliding process by two lasers irradiating a gold half-hohlraum. Via analyzing the evolutionary x-ray images, radiation fluxes and self-emission spectrum of tracers, influence on the x-ray conversion efficiency and the local plasma temperature T e , i from two gold-plasma plumes have been investigated deeply, which is similar as the configuration in Inertial Confinement Fusion (ICF). Experimental results confirm a region with high electron and ion temperatures T e , i are induced, satisfying the strong collision condition of λ i < Δ L , where λ i and Δ L are respectively the ion mean-free path and the gradient length of Te . It leads to almost 30 % increasing of M-band component compared to that from a single laser-irradiation case. Meanwhile ion temperature in this region increases more rapidly than electrons, reaching about T i ≈ ( 16 ± 4 ) keV ( T e ≈ ( 2 ± 0.2 ) keV). Thus, our studies provide the experimental evidence of quantitative x-ray enhancement and a non-equilibrium evolution simultaneously due to the plasma collision for the first time. Besides, two-dimensional simulation results reveal that this process can not be precisely described by the traditional shock-heating model by dissipating the shock energy only to ions. But by distributing the viscous heating between both electrons and ions as theoretically discussed by Miller (2020 Comput. Fluids 210 104672), numerical results can match experiments better. This discovery will be of great importance to improve the precision of prediction for ICF.


  • Open Access

    The effect of the shroud window membrane on the x-ray drive characterization of cryogenic hohlraums

    by Dong Yang, Zhichao Li, Sanwei Li, Lifei Hou, Liang Guo, Tuo Zhu, Rongqing Yi, Huabing Du, Tianming Song, Xiaohua Jiang, et al.

    Both direct and indirect drive concepts of inertial confinement fusion rely on targets with cryogenic thermonuclear fuel shells for ignition. Experiments on the Shenguang-III prototype laser facility using laser-driven gas-filled hohlraums show distinct differences between cryogenic (20 K) and warm hohlraums. Although the measured x-ray flux in the photon range from 1.6 to 4.4 keV (Au M-band) is identical between cryogenic and warm hohlraums, the cryogenic hohlraum has a much slower rate of rise and is 20% lower in peak intensity of x-ray flux in the photon range from 0.1 to 4 keV. The reasons for this drive deficit between cryogenic and warm hohlraums are investigated using a similar series of hohlraum experiments. The experiments employ three types of hohlraums to distinguish the effect of a shroud window membrane and condensates. Warm hohlraums with a shroud window membrane replicate the slower rate of rise of radiation flux of cryogenic targets. When the shroud window is present, the measured x-ray flux in the hohlraum shows a drive deficit that decreases with time. However, the measured deficit increases as the viewing angle increases. All of these results indicate that the portion of the shroud not illuminated by the lasers absorbs the outgoing x-ray flux from the hohlraum.


  • Open Access

    Experimental and simulation studies of thermal transport based on plasma flow motion in laser-ablated dense regions of Au and CH

    by Yuxue Zhang, Bo Qing, Yang Zhao, Tianming Song, Zhiyu Zhang, Gang Xiong, Chengwu Huang, Tuo Zhu, Min Lv, Jiyan Zhang, et al.

    A practical experimental method is proposed to investigate thermal transport by characterizing the motion of plasma flows through a x-ray spectroscopic technique using tracers. By simultaneously measuring multiple parameters, namely, the mass-ablation rate, the temporal evolution of plasma flow velocities and trajectories and the temperature, it is possible to observe a variety of physical processes, such as shock wave compression, heating by thermal waves, and plasma thermal expansion, and to determine their relative importance in different phases during the irradiation of CH and Au targets. From a comparison with hydrodynamic simulations, we find significant differences in the motion of the plasma flows between CH and Au, which can be attributed to different sensitivities to the thermal transport process. There are also differences in the ablation and electron temperature histories of the two materials. These results confirm that velocities and trajectories of plasma motion can provide useful evidence in the investigation of thermal conduction, and the approach presented here deserves more attention in the context of inertial confinement fusion and high-energy-density physics.