Rachel Rubino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rachel Rubino has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Alberto Corona
Nash Family Department of Neuroscience, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA
1 shared publication - Alessandro Furlan
Department of Neuroscience, Karolinska Institutet, Stockholm, Sweden
1 shared publication - Amoon Jamzad
Queen's Univ. (Canada)
1 shared publication - Andras Lasso
Laboratory for Percutaneous Surgery, Queen's University, Kingston, Ontario, Canada
1 shared publication - Bo Li
Cold spring harbor laboratory, cold spring harbor, USA
1 shared publication - Christopher J. B. Nicol
Departments of Pathology & Molecular Medicine and Biomedical & Molecular Sciences, and Cancer Biology and Genetics Division, Sinclair Cancer Research Institute, Queen’s University, Kingston, ON K7L 3N6, Canada
1 shared publication
Latest Publications
- 20 October 2022
- Published by Springer Nature in Nature Neuroscience
- Vol. 25 (11) , 1470-1480
Neurotensin neurons in the extended amygdala control dietary choice and energy homeostasis
Obesity is a global pandemic that is causally linked to many life-threatening diseases. Apart from some rare genetic conditions, the biological drivers of overeating and reduced activity are unclear. Here, we show that neurotensin-expressing neurons in the mouse interstitial nucleus of the posterior limb of the anterior commissure (IPAC), a nucleus of the central extended amygdala, encode dietary preference for unhealthy energy-dense foods. Optogenetic activation of IPACNts neurons promotes obesogenic behaviors, such as hedonic eating, and modulates food preference. Conversely, acute inhibition of IPACNts neurons reduces feeding and decreases hedonic eating. Chronic inactivation of IPACNts neurons recapitulates these effects, reduces preference for sweet, non-caloric tastants and, furthermore, enhances locomotion and energy expenditure; as a result, mice display long-term weight loss and improved metabolic health and are protected from obesity. Thus, the activity of a single neuronal population bidirectionally regulates energy homeostasis. Our findings could lead to new therapeutic strategies to prevent and treat obesity.
- 20 October 2022
- Published by Springer Nature in Nature Neuroscience
- Vol. 25 (11) , 1470-1480
Neurotensin neurons in the extended amygdala control dietary choice and energy homeostasis
Obesity is a global pandemic that is causally linked to many life-threatening diseases. Apart from some rare genetic conditions, the biological drivers of overeating and reduced activity are unclear. Here, we show that neurotensin-expressing neurons in the mouse interstitial nucleus of the posterior limb of the anterior commissure (IPAC), a nucleus of the central extended amygdala, encode dietary preference for unhealthy energy-dense foods. Optogenetic activation of IPACNts neurons promotes obesogenic behaviors, such as hedonic eating, and modulates food preference. Conversely, acute inhibition of IPACNts neurons reduces feeding and decreases hedonic eating. Chronic inactivation of IPACNts neurons recapitulates these effects, reduces preference for sweet, non-caloric tastants and, furthermore, enhances locomotion and energy expenditure; as a result, mice display long-term weight loss and improved metabolic health and are protected from obesity. Thus, the activity of a single neuronal population bidirectionally regulates energy homeostasis. Our findings could lead to new therapeutic strategies to prevent and treat obesity.
- 16 March 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11315, 44
Robotic tissue scanning with biophotonic probe
PURPOSE: Raman spectroscopy is an optical imaging technique used to characterize tissue via molecular analysis. The use of Raman spectroscopy for real-time intraoperative tissue classification requires fast analysis with minimal human intervention. In order to have accurate predictions and classifications, a large and reliable database of tissue classifications with spectra results is required. We have developed a system that can be used to generate an efficient scanning path for robotic scanning of tissues using Raman spectroscopy. METHODS: A camera mounted to a robotic controller is used to take an image of a tissue slide. The corners of the tissue slides within the sample image are identified, and the size of the slide is calculated. The image is cropped to fit the size of the slide and the image is manipulated to identify the tissue contour. A grid set to fit around the size of the tissue is calculated and a grid scanning pattern is generated. A masked image of the tissue contour is used to create a scanning pattern containing only the tissue. The tissue scanning pattern points are transformed to the robot controller coordinate system and used for robotic tissue scanning. The pattern is validated using spectroscopic scans of the tissue sample. The run time of the tissue scan pattern is compared to a region of interest scanning pattern encapsulating the tissue using the robotic controller. RESULTS: The average scanning time for the tissue scanning pattern compared to region of interest scanning reduced by 4 minutes and 58 seconds. CONCLUSION: This method reduced the number of points used for automated robotic scanning, and can be used to reduce scanning time and unusable data points to improve data collection efficiency.
- 16 March 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11315, 44
Robotic tissue scanning with biophotonic probe
PURPOSE: Raman spectroscopy is an optical imaging technique used to characterize tissue via molecular analysis. The use of Raman spectroscopy for real-time intraoperative tissue classification requires fast analysis with minimal human intervention. In order to have accurate predictions and classifications, a large and reliable database of tissue classifications with spectra results is required. We have developed a system that can be used to generate an efficient scanning path for robotic scanning of tissues using Raman spectroscopy. METHODS: A camera mounted to a robotic controller is used to take an image of a tissue slide. The corners of the tissue slides within the sample image are identified, and the size of the slide is calculated. The image is cropped to fit the size of the slide and the image is manipulated to identify the tissue contour. A grid set to fit around the size of the tissue is calculated and a grid scanning pattern is generated. A masked image of the tissue contour is used to create a scanning pattern containing only the tissue. The tissue scanning pattern points are transformed to the robot controller coordinate system and used for robotic tissue scanning. The pattern is validated using spectroscopic scans of the tissue sample. The run time of the tissue scan pattern is compared to a region of interest scanning pattern encapsulating the tissue using the robotic controller. RESULTS: The average scanning time for the tissue scanning pattern compared to region of interest scanning reduced by 4 minutes and 58 seconds. CONCLUSION: This method reduced the number of points used for automated robotic scanning, and can be used to reduce scanning time and unusable data points to improve data collection efficiency.