Marwa H. Hassan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Marwa H. Hassan has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Mohamed E. El-Sadek
Department of Medicinal Chemistry, Faculty of Pharmacy, Zagazig University, Zagazig, Egypt
4 shared publications- Sobhy Mohamed El.Adl
Department of Medicinal Chemistry, Faculty of Pharmacy, Zagazig University, Zagazig, Egypt
4 shared publications - Abdalla E. A. Hassan
Applied Nucleic Acids Research Center, Zagazig University, Zagazig, Egypt
1 shared publication Ayman A. Gouda
1 shared publication- Heba Salah Mousa
Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, South Valley University, Qena 83523, Egypt
1 shared publication Magdi Mohamed Ibrahim ElHosary
1 shared publication
Latest Publications
- 20 October 2022
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 106 (1) , 34-39
Quantitative 1HNMR Spectroscopy: Analysis of Zinc Gluconate in Utozinc® Tablets, a Mixture of Zinc Gluconate and Vitamin C
Zinc is an essential metal for humans and plays key roles in several biological events such as immunity, allergy, growth, and inflammation. The deficiency in zinc causes an increased infection rate with pathogens. Organo-zincates such as zinc gluconate are known for better absorption compared with their inorganic zinc salts. Its role in enhancing the immune system has driven a huge demand for organo-zinc supplements and in the treatment protocol of coronavirus disease, the causative agent of the COVID-19 pandemic. Herein, we report on a quantitative analysis of zinc gluconate in the authentic form in presence of vitamin C, and the method was applied to their dosage form (Utozinc® tablets). The method is simple, accurate, and validated according to ICH guidelines. Quantification of zinc gluconate formulated with vitamin C (Utozinc tablets) using Q-1HNMR. Maleic acid and deuterium oxide were used as internal standards and solvents, respectively. The linearity range, the limit of detection and quantification, stability, precision, and accuracy, were validated. The validation of the method within five concentration levels (from 10 to 50 mg/0.5 mL D2O) afforded a limit of detection of 4.58 mg/mL, a quantification limit of 15.27 mg/mL, and excellent linearity. The method proposed in the present study is simple, fast, nondestructive, and accurate. Zinc gluconate quantification values obtained by the Q-1HNMR method were found to show an acceptable correlation with those obtained by the thin-layer chromatographic technique. The method was successfully applied to Utozinc tablets, and the results were compared with the reported reference pharmacopeial method. The salt exchange between maleic acid (IS) and zinc gluconate was tested by noticing the change in the chemical shift of IS and zinc gluconate.
- 20 October 2022
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 106 (1) , 34-39
Quantitative 1HNMR Spectroscopy: Analysis of Zinc Gluconate in Utozinc® Tablets, a Mixture of Zinc Gluconate and Vitamin C
Zinc is an essential metal for humans and plays key roles in several biological events such as immunity, allergy, growth, and inflammation. The deficiency in zinc causes an increased infection rate with pathogens. Organo-zincates such as zinc gluconate are known for better absorption compared with their inorganic zinc salts. Its role in enhancing the immune system has driven a huge demand for organo-zinc supplements and in the treatment protocol of coronavirus disease, the causative agent of the COVID-19 pandemic. Herein, we report on a quantitative analysis of zinc gluconate in the authentic form in presence of vitamin C, and the method was applied to their dosage form (Utozinc® tablets). The method is simple, accurate, and validated according to ICH guidelines. Quantification of zinc gluconate formulated with vitamin C (Utozinc tablets) using Q-1HNMR. Maleic acid and deuterium oxide were used as internal standards and solvents, respectively. The linearity range, the limit of detection and quantification, stability, precision, and accuracy, were validated. The validation of the method within five concentration levels (from 10 to 50 mg/0.5 mL D2O) afforded a limit of detection of 4.58 mg/mL, a quantification limit of 15.27 mg/mL, and excellent linearity. The method proposed in the present study is simple, fast, nondestructive, and accurate. Zinc gluconate quantification values obtained by the Q-1HNMR method were found to show an acceptable correlation with those obtained by the thin-layer chromatographic technique. The method was successfully applied to Utozinc tablets, and the results were compared with the reported reference pharmacopeial method. The salt exchange between maleic acid (IS) and zinc gluconate was tested by noticing the change in the chemical shift of IS and zinc gluconate.
- 4 May 2019
- Published by Taylor & Francis in Analytical Chemistry Letters
- Vol. 9 (3) , 362-372
Spectrophotometric Analysis of Azithromycin and Clarithromycin in Tablets and Human Plasma Using p-Chloranilic Acid
A novel spectrophotometric method for rapid estimation of clarithromycin and azithromycin in authentic sample, pharmaceutical dosage forms and in human plasma was developed using p-chloranilic acid. The method depends on charge transfer reaction between p-chloranilic acid and the mentioned drugs. Linearity was observed over a concentration range of 5 to 50 μg/mL-1 clarithromycin and azithromycin. The results indicate that the proposed method is very sensitive, rapid, accurate, selective, and reproducible. The method was validated according to ICH guidelines. The method has been successfully applied for the analysis of marketed formulations and spiked human plasma.
- 4 May 2019
- Published by Taylor & Francis in Analytical Chemistry Letters
- Vol. 9 (3) , 362-372
Spectrophotometric Analysis of Azithromycin and Clarithromycin in Tablets and Human Plasma Using p-Chloranilic Acid
A novel spectrophotometric method for rapid estimation of clarithromycin and azithromycin in authentic sample, pharmaceutical dosage forms and in human plasma was developed using p-chloranilic acid. The method depends on charge transfer reaction between p-chloranilic acid and the mentioned drugs. Linearity was observed over a concentration range of 5 to 50 μg/mL-1 clarithromycin and azithromycin. The results indicate that the proposed method is very sensitive, rapid, accurate, selective, and reproducible. The method was validated according to ICH guidelines. The method has been successfully applied for the analysis of marketed formulations and spiked human plasma.
- 4 March 2017
- Published by Taylor & Francis in Analytical Chemistry Letters
- Vol. 7 (2) , 271-279
Determination and Validation of Piracetam in Pharmaceuticals Using Quantitative Nuclear Magnetic Resonance Spectroscopy
A novel, simple and accurate proton nuclear magnetic resonance spectroscopy (1H-NMR) method was proposed and validated for piracetam determination. Maleic acid was used as the internal standard and deuterium oxide (D2O) as the diluent. NMR signals at 3.94 ppm and 6.25 ppm for the proton of piracetam and maleic acid respectively were used for the quantification of piracetam. The different validation parameters of performance of the method, such as linearity, precision and accuracy, satisfied our requirements well. The linearity range was (10–50 mg/o.6 ml of (D2O) with correlation coefficient (r=0.999). The method was the first method that determine piracetam in bulk and in pharmaceutical dosage form using quantitative NMR spectroscopy.
- 4 March 2017
- Published by Taylor & Francis in Analytical Chemistry Letters
- Vol. 7 (2) , 271-279
Determination and Validation of Piracetam in Pharmaceuticals Using Quantitative Nuclear Magnetic Resonance Spectroscopy
A novel, simple and accurate proton nuclear magnetic resonance spectroscopy (1H-NMR) method was proposed and validated for piracetam determination. Maleic acid was used as the internal standard and deuterium oxide (D2O) as the diluent. NMR signals at 3.94 ppm and 6.25 ppm for the proton of piracetam and maleic acid respectively were used for the quantification of piracetam. The different validation parameters of performance of the method, such as linearity, precision and accuracy, satisfied our requirements well. The linearity range was (10–50 mg/o.6 ml of (D2O) with correlation coefficient (r=0.999). The method was the first method that determine piracetam in bulk and in pharmaceutical dosage form using quantitative NMR spectroscopy.
- 2 September 2016
- Published by Taylor & Francis in Analytical Chemistry Letters
- Vol. 6 (5) , 622-630
HPLC Method for Determination of Methocarbamol and Paracetamol in Their Pharmaceutical Formulation
A validated RP-HPC method was developed for the simultaneous assay of methocarbamol (MTC) and paracetamol (PAR) in their combined tablets. A validated HPLC method was developed for the assay of them. The method was performed on BDS HYPERSIL C18 column (250 x 4.6 mm, 5 μ) and the mobile phase was consisted of a mixture of methanol : water (60:40, v/v) at 278 nm and a flow rate of 1.4 ml/min at ambient temperature. Under these conditions, Paracetamol and Methocarbamol eluted at 2.8, 6.1 minutes respectively. Calibration curve was obeyed in the range of (20–160) μg/ ml for Methocarbamol or (16.25–130) μg/ ml for Paracetamol. The proposed method was validated in terms of linearity, accuracy, precision and limits of detection and quantitation according to ICH.
- 2 September 2016
- Published by Taylor & Francis in Analytical Chemistry Letters
- Vol. 6 (5) , 622-630
HPLC Method for Determination of Methocarbamol and Paracetamol in Their Pharmaceutical Formulation
A validated RP-HPC method was developed for the simultaneous assay of methocarbamol (MTC) and paracetamol (PAR) in their combined tablets. A validated HPLC method was developed for the assay of them. The method was performed on BDS HYPERSIL C18 column (250 x 4.6 mm, 5 μ) and the mobile phase was consisted of a mixture of methanol : water (60:40, v/v) at 278 nm and a flow rate of 1.4 ml/min at ambient temperature. Under these conditions, Paracetamol and Methocarbamol eluted at 2.8, 6.1 minutes respectively. Calibration curve was obeyed in the range of (20–160) μg/ ml for Methocarbamol or (16.25–130) μg/ ml for Paracetamol. The proposed method was validated in terms of linearity, accuracy, precision and limits of detection and quantitation according to ICH.