Arne Maes
Research Subjects
Arne Maes has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Greet Kerckhofs
Mechatronic, Electrical Energy and Dynamic Systems, Institute of Mechanics, Materials, and Civil Engineering, UCLouvain, 1348 Louvain-la-Neuve, Belgium; Pole of Morphology, Institute of Experimental and Clinical Research, UCLouvain, 1200 Woluwe-Saint-Lambert, Belgium; Department of Materials Engineering, KU Leuven, 3001 Leuven, Belgium; Prometheus, Division of Skeletal Tissue Engineering, KU Leuven, 3000 Leuven, Belgium
6 shared publications - Tim Balcaen
KU Leuven, Department of Chemistry, Celestijnenlaan 200F, P.O. Box 2404, B-3001 Leuven, Belgium
3 shared publications - Camille Pestiaux
UCLouvain
2 shared publications - Delia Hoffmann
UCLouvain
2 shared publications Grzegorz Pyka
Pole of Morphology, Institute of Experimental and Clinical Research, UCLouvain , Avenue E. Mounier 52 - box B1.52.04, 1200 Brussels
2 shared publications- Grzegorz Pyka
UCLouvain
2 shared publications
Latest Publications
- 24 August 2025
- Published by Springer Nature
- p. 141-183
X-Ray-Based 3D Histo(patho)logy of Biological Tissues Using Contrast-Enhanced MicroCT
- 24 August 2025
- Published by Springer Nature
- p. 141-183
X-Ray-Based 3D Histo(patho)logy of Biological Tissues Using Contrast-Enhanced MicroCT
- 8 May 2025
- Published by Springer Nature
- p. 1-43
X-Ray-Based 3D Histo(patho)logy of Biological Tissues Using Contrast-Enhanced MicroCT
- 8 May 2025
- Published by Springer Nature
- p. 1-43
X-Ray-Based 3D Histo(patho)logy of Biological Tissues Using Contrast-Enhanced MicroCT
- 17 March 2025
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 31 (2)
3D Histological Analysis of Soft Tissues by Contrast-Enhanced X-Ray Microfocus Computed Tomography: Screening and Staining Optimization of Contrast-Enhancing Staining Agents
The gold standard for studying biological soft tissues at the microscale (i.e., histology) is tissue sectioning with subsequent colorimetric or fluorescent staining and visual inspection under the microscope. When tissue integrity must be maintained for 3D histological assessment, contrast-enhanced microfocus X-ray computed tomography (CECT) is a promising solution, but there is still a lack of staining protocol optimization of contrast-enhancing staining agents (CESAs). Therefore, in this study, mouse auricles were incubated with Hafnium-substituted Wells–Dawson polyoxometalate, cationic iodinated contrast agent, or Lugol's iodine and were imaged with high-resolution CECT. Alignment with corresponding H&E-stained sections enabled the identification and segmentation of different tissue types. Contrast differences between tissue types were increased by washing the samples after staining or by combining CESAs. Finally, we proved that the latter could be used to quantitatively assess the 3D thickness distribution of the epidermis in the ears of a mouse model of psoriasis-like dermatitis. In conclusion, CECT and bright-field microscopy are complementary and not mutually exclusive techniques for the histological assessment of biological tissues. While bright-field microscopy gives detailed information about the cellular composition of tissues, CECT provides a better insight into the spatial interrelationship of tissues and is a powerful tool for performing 3D structural quantification.
- 17 March 2025
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 31 (2)
3D Histological Analysis of Soft Tissues by Contrast-Enhanced X-Ray Microfocus Computed Tomography: Screening and Staining Optimization of Contrast-Enhancing Staining Agents
The gold standard for studying biological soft tissues at the microscale (i.e., histology) is tissue sectioning with subsequent colorimetric or fluorescent staining and visual inspection under the microscope. When tissue integrity must be maintained for 3D histological assessment, contrast-enhanced microfocus X-ray computed tomography (CECT) is a promising solution, but there is still a lack of staining protocol optimization of contrast-enhancing staining agents (CESAs). Therefore, in this study, mouse auricles were incubated with Hafnium-substituted Wells–Dawson polyoxometalate, cationic iodinated contrast agent, or Lugol's iodine and were imaged with high-resolution CECT. Alignment with corresponding H&E-stained sections enabled the identification and segmentation of different tissue types. Contrast differences between tissue types were increased by washing the samples after staining or by combining CESAs. Finally, we proved that the latter could be used to quantitatively assess the 3D thickness distribution of the epidermis in the ears of a mouse model of psoriasis-like dermatitis. In conclusion, CECT and bright-field microscopy are complementary and not mutually exclusive techniques for the histological assessment of biological tissues. While bright-field microscopy gives detailed information about the cellular composition of tissues, CECT provides a better insight into the spatial interrelationship of tissues and is a powerful tool for performing 3D structural quantification.
- Open Access
- 15 May 2024
- Published by Wolters Kluwer Health in Transplantation Direct
- Vol. 10 (6) , e1624
Multilevel Analysis of the Neovascularization and Integration Process of a Nonvascularized Rectus Fascia Transplantation
Background.: Failure to close the abdominal wall after intestinal transplantation (ITx) or multivisceral Tx remains a surgical challenge. An attractive method is the use of nonvascularized rectus fascia (NVRF) in which both layers of the donor abdominal rectus fascia are used as an inlay patch without vascular anastomosis. How this graft integrates over time remains unknown. The study aims to provide a multilevel analysis of the neovascularization and integration process of the NVRF. Methods.: Three NVRF-Tx were performed after ITx. Clinical, radiological, histological, and immunological data were analyzed to get insights into the neovascularization and integration process of the NVRF. Moreover, cryogenic contrast-enhanced microfocus computed tomography (microCT) analysis was used for detailed reconstruction of the vasculature in and around the NVRF (3-dimensional histology). Results.: Two men (31- and 51-y-old) and 1 woman (49-y-old) underwent 2 multivisceral Tx and 1 combined liver-ITx, respectively. A CT scan showed contrast enhancement around the fascia graft at 5 days post-Tx. At 6 weeks, newly formed blood vessels were visualized around the graft with Doppler ultrasound. Biopsies at 2 weeks post-Tx revealed inflammation around the NVRF and early fibrosis. At 6 months, classical 2-dimensional histological analysis of a biopsy confirmed integration of the fascia graft with strong fibrotic reaction without signs of rejection. A cryogenic contrast-enhanced microCT scan of the same biopsy revealed the presence of microvasculature, enveloping and penetrating the donor fascia. Conclusions.: We showed clinical, histological, and microCT evidence of the neovascularization and integration process of the NVRF after Tx.
- 15 May 2024
- Published by Wolters Kluwer Health in Transplantation Direct
- Vol. 10 (6) , e1624
Open AccessMultilevel Analysis of the Neovascularization and Integration Process of a Nonvascularized Rectus Fascia Transplantation
Background.: Failure to close the abdominal wall after intestinal transplantation (ITx) or multivisceral Tx remains a surgical challenge. An attractive method is the use of nonvascularized rectus fascia (NVRF) in which both layers of the donor abdominal rectus fascia are used as an inlay patch without vascular anastomosis. How this graft integrates over time remains unknown. The study aims to provide a multilevel analysis of the neovascularization and integration process of the NVRF. Methods.: Three NVRF-Tx were performed after ITx. Clinical, radiological, histological, and immunological data were analyzed to get insights into the neovascularization and integration process of the NVRF. Moreover, cryogenic contrast-enhanced microfocus computed tomography (microCT) analysis was used for detailed reconstruction of the vasculature in and around the NVRF (3-dimensional histology). Results.: Two men (31- and 51-y-old) and 1 woman (49-y-old) underwent 2 multivisceral Tx and 1 combined liver-ITx, respectively. A CT scan showed contrast enhancement around the fascia graft at 5 days post-Tx. At 6 weeks, newly formed blood vessels were visualized around the graft with Doppler ultrasound. Biopsies at 2 weeks post-Tx revealed inflammation around the NVRF and early fibrosis. At 6 months, classical 2-dimensional histological analysis of a biopsy confirmed integration of the fascia graft with strong fibrotic reaction without signs of rejection. A cryogenic contrast-enhanced microCT scan of the same biopsy revealed the presence of microvasculature, enveloping and penetrating the donor fascia. Conclusions.: We showed clinical, histological, and microCT evidence of the neovascularization and integration process of the NVRF after Tx.
- Open Access
- 9 April 2024
- Published by Wiley in International Journal of Biomedical Imaging
- Vol. 2024, 1-15
X-Ray-Based 3D Histopathology of the Kidney Using Cryogenic Contrast-Enhanced MicroCT
The kidney’s microstructure, which comprises a highly convoluted tubular and vascular network, can only be partially revealed using classical 2D histology. Considering that the kidney’s microstructure is closely related to its function and is often affected by pathologies, there is a need for powerful and high-resolution 3D imaging techniques to visualize the microstructure. Here, we present how cryogenic contrast-enhanced microCT (cryo-CECT) allowed 3D visualization of glomeruli, tubuli, and vasculature. By comparing different contrast-enhancing staining agents and freezing protocols, we found that the preferred sample preparation protocol was the combination of staining with 1:2 hafnium(IV)-substituted Wells-Dawson polyoxometalate and freezing by submersion in isopentane at −78°C. This optimized protocol showed to be highly sensitive, allowing to detect small pathology-induced microstructural changes in a mouse model of mild trauma-related acute kidney injury after thorax trauma and hemorrhagic shock. In summary, we demonstrated that cryo-CECT is an effective 3D histopathological tool that allows to enhance our understanding of kidney tissue microstructure and their related function.
- 9 April 2024
- Published by Wiley in International Journal of Biomedical Imaging
- Vol. 2024, 1-15
Open AccessX-Ray-Based 3D Histopathology of the Kidney Using Cryogenic Contrast-Enhanced MicroCT
The kidney’s microstructure, which comprises a highly convoluted tubular and vascular network, can only be partially revealed using classical 2D histology. Considering that the kidney’s microstructure is closely related to its function and is often affected by pathologies, there is a need for powerful and high-resolution 3D imaging techniques to visualize the microstructure. Here, we present how cryogenic contrast-enhanced microCT (cryo-CECT) allowed 3D visualization of glomeruli, tubuli, and vasculature. By comparing different contrast-enhancing staining agents and freezing protocols, we found that the preferred sample preparation protocol was the combination of staining with 1:2 hafnium(IV)-substituted Wells-Dawson polyoxometalate and freezing by submersion in isopentane at −78°C. This optimized protocol showed to be highly sensitive, allowing to detect small pathology-induced microstructural changes in a mouse model of mild trauma-related acute kidney injury after thorax trauma and hemorrhagic shock. In summary, we demonstrated that cryo-CECT is an effective 3D histopathological tool that allows to enhance our understanding of kidney tissue microstructure and their related function.
- 21 January 2023
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 637, 500-512
Internal and interfacial microstructure characterization of ice droplets on surfaces by X-ray computed tomography
- 21 January 2023
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 637, 500-512
Internal and interfacial microstructure characterization of ice droplets on surfaces by X-ray computed tomography
- Open Access
- 20 October 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-14
Cryogenic contrast-enhanced microCT enables nondestructive 3D quantitative histopathology of soft biological tissues
Biological tissues comprise a spatially complex structure, composition and organization at the microscale, named the microstructure. Given the close structure-function relationships in tissues, structural characterization is essential to fully understand the functioning of healthy and pathological tissues, as well as the impact of possible treatments. Here, we present a nondestructive imaging approach to perform quantitative 3D histo(patho)logy of biological tissues, termed Cryogenic Contrast-Enhanced MicroCT (cryo-CECT). By combining sample staining, using an X-ray contrast-enhancing staining agent, with freezing the sample at the optimal freezing rate, cryo-CECT enables 3D visualization and structural analysis of individual tissue constituents, such as muscle and collagen fibers. We applied cryo-CECT on murine hearts subjected to pressure overload following transverse aortic constriction surgery. Cryo-CECT allowed to analyze, in an unprecedented manner, the orientation and diameter of the individual muscle fibers in the entire heart, as well as the 3D localization of fibrotic regions within the myocardial layers. We foresee further applications of cryo-CECT in the optimization of tissue/food preservation and donor banking, showing that cryo-CECT also has clinical and industrial potential.
- 20 October 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-14
Open AccessCryogenic contrast-enhanced microCT enables nondestructive 3D quantitative histopathology of soft biological tissues
Biological tissues comprise a spatially complex structure, composition and organization at the microscale, named the microstructure. Given the close structure-function relationships in tissues, structural characterization is essential to fully understand the functioning of healthy and pathological tissues, as well as the impact of possible treatments. Here, we present a nondestructive imaging approach to perform quantitative 3D histo(patho)logy of biological tissues, termed Cryogenic Contrast-Enhanced MicroCT (cryo-CECT). By combining sample staining, using an X-ray contrast-enhancing staining agent, with freezing the sample at the optimal freezing rate, cryo-CECT enables 3D visualization and structural analysis of individual tissue constituents, such as muscle and collagen fibers. We applied cryo-CECT on murine hearts subjected to pressure overload following transverse aortic constriction surgery. Cryo-CECT allowed to analyze, in an unprecedented manner, the orientation and diameter of the individual muscle fibers in the entire heart, as well as the 3D localization of fibrotic regions within the myocardial layers. We foresee further applications of cryo-CECT in the optimization of tissue/food preservation and donor banking, showing that cryo-CECT also has clinical and industrial potential.