Sara Aniki Christner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sara Aniki Christner has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Stephanie Tina Sauer
Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, 97080 Würzburg, Germany
5 shared publications - Andreas Steven Kunz
Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany
4 shared publications - Henner Huflage
Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany
4 shared publications - Jan-Peter Grunz
Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany
4 shared publications - Thorsten Alexander Bley
Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany
4 shared publications - Theresa Sophie Patzer
Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA; Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg 97080, Germany
3 shared publications
Latest Publications
- Open Access
Prognostic Factors in Therapy Regimes of Breast Cancer Patients with Brain Metastases: A Retrospective Monocentric Analysis
Background: Breast cancer patients who develop brain metastases have a high mortality rate and a massive decrease in quality of life. Approximately 10–15% of all patients with breast cancer (BC) and 5–40% of all patients with metastatic BC develop brain metastasis (BM) during the course of the disease. However, there is only limited knowledge about prognostic factors in the treatment of patients with brain metastases in breast cancer (BMBC). Therefore, we retrospectively analyzed data of BMBC patients from the University Hospital of Würzburg for treatment patterns to find characteristics associated with a better or worse prognosis. These findings should help to treat the ever-increasing collective of patients with BMBC better in the future. Methods: The clinical data of 337 patients with cerebral metastatic breast cancer (date of death between 2004 and 2021) treated at the Department of Gynecology and Obstetrics of the University Hospital Würzburg were retrospectively analyzed, with a focus on patients’ survival. Results: The involvement of regional lymph nodes at initial diagnosis, the immunohistochemical subtype of TNBC at the onset of BMBC, and extracranial metastases at the time of BM diagnosis (bone, liver, lung metastases) were associated with a worse prognosis. In contrast, the immunohistochemical subtype of HER2/neu, the sole occurrence of a singular BM, the local surgical removal of BMs, and radiotherapy (especially stereotactic radiotherapy) were associated with prolonged survival. The number of therapies before the diagnosis of BMs also had a prognostic influence. Conclusions: Looking back at data is crucial for pinpointing risk elements affecting survival after a BM diagnosis. In our investigation, along with established factors like immunohistologic subtype, BM count, surgical excision, stereotactic irradiation, and type of extracranial metastasis, we also found that the number of therapies before BM diagnosis and the initial lymph node status were associated with patients’ survival. Potentially, these factors could be included in prospective prognostic scores for evaluating brain metastasis survival rates, thereby aiding in making appropriate treatment suggestions for impacted patients.
Open AccessPrognostic Factors in Therapy Regimes of Breast Cancer Patients with Brain Metastases: A Retrospective Monocentric Analysis
Background: Breast cancer patients who develop brain metastases have a high mortality rate and a massive decrease in quality of life. Approximately 10–15% of all patients with breast cancer (BC) and 5–40% of all patients with metastatic BC develop brain metastasis (BM) during the course of the disease. However, there is only limited knowledge about prognostic factors in the treatment of patients with brain metastases in breast cancer (BMBC). Therefore, we retrospectively analyzed data of BMBC patients from the University Hospital of Würzburg for treatment patterns to find characteristics associated with a better or worse prognosis. These findings should help to treat the ever-increasing collective of patients with BMBC better in the future. Methods: The clinical data of 337 patients with cerebral metastatic breast cancer (date of death between 2004 and 2021) treated at the Department of Gynecology and Obstetrics of the University Hospital Würzburg were retrospectively analyzed, with a focus on patients’ survival. Results: The involvement of regional lymph nodes at initial diagnosis, the immunohistochemical subtype of TNBC at the onset of BMBC, and extracranial metastases at the time of BM diagnosis (bone, liver, lung metastases) were associated with a worse prognosis. In contrast, the immunohistochemical subtype of HER2/neu, the sole occurrence of a singular BM, the local surgical removal of BMs, and radiotherapy (especially stereotactic radiotherapy) were associated with prolonged survival. The number of therapies before the diagnosis of BMs also had a prognostic influence. Conclusions: Looking back at data is crucial for pinpointing risk elements affecting survival after a BM diagnosis. In our investigation, along with established factors like immunohistologic subtype, BM count, surgical excision, stereotactic irradiation, and type of extracranial metastasis, we also found that the number of therapies before BM diagnosis and the initial lymph node status were associated with patients’ survival. Potentially, these factors could be included in prospective prognostic scores for evaluating brain metastasis survival rates, thereby aiding in making appropriate treatment suggestions for impacted patients.
- Open Access
Preliminary Experience with Virtual Monoenergetic Imaging and Iodine Mapping in the Primary Staging of Endometrial Cancer
This study investigated whether virtual monoenergetic images (VMIs) and iodine mapping based on dual-energy CT (DECT) provide advantages in the assessment of endometrial cancer. A dual-source DECT was performed for primary staging of histologically proven endometrioid adenocarcinoma in 21 women (66.8 ± 12.0 years). In addition to iodine maps, VMIs at 40, 50, 60, 70, and 80 keV were reconstructed from polyenergetic images (PEIs). Objective analysis comprised the measurement of tumor contrast, contrast-to-noise ratio, and normalized iodine concentration (NIC). In addition, three radiologists independently rated tumor conspicuity. The highest tumor contrast (106.6 ± 45.0 HU) and contrast-to-noise ratio (4.4 ± 2.0) was established for VMIs at 40 keV. Tumor contrast in all VMIs ≤ 60 keV was higher than in PEIs (p < 0.001). The NIC of malignant tissue measured in iodine maps was substantially lower compared with a healthy myometrium (0.3 ± 0.1 versus 0.6 ± 0.1 mg/mL; p < 0.001). Tumor conspicuity was highest in 40 keV datasets, whereas no difference was found among PEIs and VMIs at 60 and 70 keV (p ≥ 0.334). Interobserver agreement was good, indicated by an intraclass correlation coefficient of 0.824 (0.772–0.876; p < 0.001). In conclusion, computation of VMIs at 40 keV and color-coded iodine maps aids the assessment of endometroid adenocarcinoma in primary staging.
Open AccessPreliminary Experience with Virtual Monoenergetic Imaging and Iodine Mapping in the Primary Staging of Endometrial Cancer
This study investigated whether virtual monoenergetic images (VMIs) and iodine mapping based on dual-energy CT (DECT) provide advantages in the assessment of endometrial cancer. A dual-source DECT was performed for primary staging of histologically proven endometrioid adenocarcinoma in 21 women (66.8 ± 12.0 years). In addition to iodine maps, VMIs at 40, 50, 60, 70, and 80 keV were reconstructed from polyenergetic images (PEIs). Objective analysis comprised the measurement of tumor contrast, contrast-to-noise ratio, and normalized iodine concentration (NIC). In addition, three radiologists independently rated tumor conspicuity. The highest tumor contrast (106.6 ± 45.0 HU) and contrast-to-noise ratio (4.4 ± 2.0) was established for VMIs at 40 keV. Tumor contrast in all VMIs ≤ 60 keV was higher than in PEIs (p < 0.001). The NIC of malignant tissue measured in iodine maps was substantially lower compared with a healthy myometrium (0.3 ± 0.1 versus 0.6 ± 0.1 mg/mL; p < 0.001). Tumor conspicuity was highest in 40 keV datasets, whereas no difference was found among PEIs and VMIs at 60 and 70 keV (p ≥ 0.334). Interobserver agreement was good, indicated by an intraclass correlation coefficient of 0.824 (0.772–0.876; p < 0.001). In conclusion, computation of VMIs at 40 keV and color-coded iodine maps aids the assessment of endometroid adenocarcinoma in primary staging.
- Open Access
- 20 January 2024
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 107, 100-110
Breast lesion morphology assessment with high and standard b values in diffusion-weighted imaging at 3 Tesla
- 20 January 2024
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 107, 100-110
Open AccessBreast lesion morphology assessment with high and standard b values in diffusion-weighted imaging at 3 Tesla
- Open Access
- 17 April 2023
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 96 (1145) , 20220967
Artificial-intelligence-enhanced synthetic thick slabs versus standard slices in digital breast tomosynthesis
Objectives: Digital breast tomosynthesis (DBT) can provide additional information over mammography, albeit at the cost of prolonged reading time. This study retrospectively investigated the impact of reading enhanced synthetic 6 mm slabs instead of standard 1 mm slices on interpretation time and readers performance in a diagnostic assessment centre. Methods: Three radiologists (R1-3; 6/4/2 years of breast imaging experience) reviewed 111 diagnostic DBT examinations. Two datasets were interpreted independently for each patient, with one set containing artificial-intelligence-enhanced synthetic 6 mm slabs with 3 mm overlap, while the other set comprised standard 1 mm slices. Blinded to histology and follow-up, readers noted individual BIRADS categories and diagnostic confidence while reading time was recorded. Among the 111 examinations, 70 findings were histopathologically correlated including 56 malignancies. Results: No significant difference was found between BIRADS categories assigned based on 6 mm vs 1 mm datasets (p ≥ 0.317). Diagnostic accuracy was comparable for 6 mm and 1 mm readings (R1: 87.0% vs 87.0%; R2: 86.1% vs 87.0%; R3: 80.0% vs 84.4%; p ≥ 0.125) with high interrater agreement (intraclass correlation coefficient 0.848 vs 0.865). One reader reported higher confidence with 1 mm slices (R1: p = 0.033). Reading time was substantially shorter when interpreting 6 mm slabs compared to 1 mm slices (R1: 33.5 vs 46.2; R2: 49.1 vs 64.8; R3: 39.5 vs 67.2 sec; all p < 0.001). Conclusions: Artificial-intelligence-enhanced synthetic 6 mm slabs allow for substantial interpretation time reduction in diagnostic DBT without a decrease in reader accuracy. Advances in knowledge: A simplified slab-only protocol instead of 1 mm slices may offset the higher reading time without a loss of diagnosis-relevant image information in first and second readings. Further evaluations are required regarding workflow implications, particularly in screening settings.
- 17 April 2023
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 96 (1145) , 20220967
Open AccessArtificial-intelligence-enhanced synthetic thick slabs versus standard slices in digital breast tomosynthesis
Objectives: Digital breast tomosynthesis (DBT) can provide additional information over mammography, albeit at the cost of prolonged reading time. This study retrospectively investigated the impact of reading enhanced synthetic 6 mm slabs instead of standard 1 mm slices on interpretation time and readers performance in a diagnostic assessment centre. Methods: Three radiologists (R1-3; 6/4/2 years of breast imaging experience) reviewed 111 diagnostic DBT examinations. Two datasets were interpreted independently for each patient, with one set containing artificial-intelligence-enhanced synthetic 6 mm slabs with 3 mm overlap, while the other set comprised standard 1 mm slices. Blinded to histology and follow-up, readers noted individual BIRADS categories and diagnostic confidence while reading time was recorded. Among the 111 examinations, 70 findings were histopathologically correlated including 56 malignancies. Results: No significant difference was found between BIRADS categories assigned based on 6 mm vs 1 mm datasets (p ≥ 0.317). Diagnostic accuracy was comparable for 6 mm and 1 mm readings (R1: 87.0% vs 87.0%; R2: 86.1% vs 87.0%; R3: 80.0% vs 84.4%; p ≥ 0.125) with high interrater agreement (intraclass correlation coefficient 0.848 vs 0.865). One reader reported higher confidence with 1 mm slices (R1: p = 0.033). Reading time was substantially shorter when interpreting 6 mm slabs compared to 1 mm slices (R1: 33.5 vs 46.2; R2: 49.1 vs 64.8; R3: 39.5 vs 67.2 sec; all p < 0.001). Conclusions: Artificial-intelligence-enhanced synthetic 6 mm slabs allow for substantial interpretation time reduction in diagnostic DBT without a decrease in reader accuracy. Advances in knowledge: A simplified slab-only protocol instead of 1 mm slices may offset the higher reading time without a loss of diagnosis-relevant image information in first and second readings. Further evaluations are required regarding workflow implications, particularly in screening settings.
- 20 October 2022
- Published by Elsevier in Radiography
- Vol. 29 (1) , 44-49
Potential of employing a quantum iterative reconstruction algorithm for ultra-high-resolution photon-counting detector CT of the hip
- 20 October 2022
- Published by Elsevier in Radiography
- Vol. 29 (1) , 44-49
Potential of employing a quantum iterative reconstruction algorithm for ultra-high-resolution photon-counting detector CT of the hip