Andrea Moggi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Andrea Moggi has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- Maurizio Massa
INFN Sezione di Pisa, Largo Bruno Pontecorvo 3, Pisa, Italy
5 shared publications F. Bosi
3 shared publications- Fabrizio Palla
INFN Sezione di Pisa
3 shared publications S. Mondal
3 shared publications- Thomas Bergauer
Institut für Hochenergiephysik
3 shared publications - Valerio Re
INFN Sezione di Pavia
3 shared publications
Latest Publications
- Open Access
- 21 July 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1092
Impact of radiation damage to the performance of depleted monolithic active pixel sensors for Belle II vertex detector upgrade
- 21 July 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1092
Open AccessImpact of radiation damage to the performance of depleted monolithic active pixel sensors for Belle II vertex detector upgrade
- 7 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. PP (10518223) , 1-6
Compatibility Study of the LiteBIRD SQUID Controller Unit With a Dual-Stage SQUID Amplification Chain
The LiteBIRD satellite will map the polarisation of the Cosmic Microwave Background (CMB) with unprecedented sensitivity by means of antenna-coupled transition edge sensors (TESs). Its current design features single SQUID-Array Amplifiers (SAA) at a temperature of about 400 mK in order to read out up to 64 TESs in a frequency division multiplexing scheme. The front-end part of the electronics (the SQUID Controller Assembly -SCA) was designed to handle this configuration. Nevertheless, alternative configurations of the experiment are being studied that might require a dual-stage SQUID (DSS) amplification chain in order to meet thermal and noise requirements. In light of this possibility, we have successfully investigated the feasibility of controlling two individual SAAs in a DSS Amplifier (DSSA) configuration with two independent channels of the present SCA. The SQUID directly connected to the sensor, commonly referred to as ‘front-end’, behaves as an emitter-follower, or buffer, circuit and it decouples the impedance of the TES(s) from the rest of the readout chain whilst producing a moderate amplification. The second SQUID, ‘booster’, is responsible for a high-gain amplification of the signal and can be thermally decoupled from the front-end allowing it to dissipate a lot more power and thus exhibiting a higher gain. We characterised a breadboard model in which two SQUID amplifiers are cascaded but hosted on the same circuit board and thus not thermally decoupled. This was intended to perform functional tests and to assess the feasibility of controlling a DSSA without introducing major changes in the already developed LiteBIRD SCA. We present the typical I-V and I-$\Phi$ curves of the two SQUIDs along with the characterisation of the DSSA in terms of bandwidth, linearity and total harmonic distortion (THD).
- 7 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. PP (10518223) , 1-6
Compatibility Study of the LiteBIRD SQUID Controller Unit With a Dual-Stage SQUID Amplification Chain
The LiteBIRD satellite will map the polarisation of the Cosmic Microwave Background (CMB) with unprecedented sensitivity by means of antenna-coupled transition edge sensors (TESs). Its current design features single SQUID-Array Amplifiers (SAA) at a temperature of about 400 mK in order to read out up to 64 TESs in a frequency division multiplexing scheme. The front-end part of the electronics (the SQUID Controller Assembly -SCA) was designed to handle this configuration. Nevertheless, alternative configurations of the experiment are being studied that might require a dual-stage SQUID (DSS) amplification chain in order to meet thermal and noise requirements. In light of this possibility, we have successfully investigated the feasibility of controlling two individual SAAs in a DSS Amplifier (DSSA) configuration with two independent channels of the present SCA. The SQUID directly connected to the sensor, commonly referred to as ‘front-end’, behaves as an emitter-follower, or buffer, circuit and it decouples the impedance of the TES(s) from the rest of the readout chain whilst producing a moderate amplification. The second SQUID, ‘booster’, is responsible for a high-gain amplification of the signal and can be thermally decoupled from the front-end allowing it to dissipate a lot more power and thus exhibiting a higher gain. We characterised a breadboard model in which two SQUID amplifiers are cascaded but hosted on the same circuit board and thus not thermally decoupled. This was intended to perform functional tests and to assess the feasibility of controlling a DSSA without introducing major changes in the already developed LiteBIRD SCA. We present the typical I-V and I-$\Phi$ curves of the two SQUIDs along with the characterisation of the DSSA in terms of bandwidth, linearity and total harmonic distortion (THD).
- Open Access
- 1 August 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (08) , P08027
Operation and performance of the CMS silicon strip tracker with proton-proton collisions at the CERN LHC
Salient aspects of the commissioning, calibration, and performance of the CMS silicon strip tracker are discussed, drawing on experience during operation with proton-proton collisions delivered by the CERN LHC. The data were obtained with a variety of luminosities. The operating temperature of the strip tracker was changed several times during this period and results are shown as a function of temperature in several cases. Details of the system performance are presented, including occupancy, signal-to-noise ratio, Lorentz angle, and single-hit spatial resolution. Saturation effects in the APV25 readout chip preamplifier observed during early Run 2 are presented, showing the effect on various observables and the subsequent remedy. Studies of radiation effects on the strip tracker are presented both for the optical readout links and the silicon sensors. The observed effects are compared to simulation, where available, and they generally agree well with expectations.
- 1 August 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (08) , P08027
Open AccessOperation and performance of the CMS silicon strip tracker with proton-proton collisions at the CERN LHC
Salient aspects of the commissioning, calibration, and performance of the CMS silicon strip tracker are discussed, drawing on experience during operation with proton-proton collisions delivered by the CERN LHC. The data were obtained with a variety of luminosities. The operating temperature of the strip tracker was changed several times during this period and results are shown as a function of temperature in several cases. Details of the system performance are presented, including occupancy, signal-to-noise ratio, Lorentz angle, and single-hit spatial resolution. Saturation effects in the APV25 readout chip preamplifier observed during early Run 2 are presented, showing the effect on various observables and the subsequent remedy. Studies of radiation effects on the strip tracker are presented both for the optical readout links and the silicon sensors. The observed effects are compared to simulation, where available, and they generally agree well with expectations.
- 11 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Radio Frequency Identification
- Vol. 8, 601-608
High-Speed Optical Wireless System for Extreme Space Conditions
In this paper, we present and deeply characterize a high-speed Optical Wireless Communication (OWC) system designed for use in space applications that operates at 1 Gbit/s over a directed optical link for a point-to-point link inside a 3U CubeSat. The OWC transmitter is equipped with a Vertical Cavity Surface Emitting Laser (VCSEL) that emits at 850 nm, whilst the receiver uses a PIN Photo-Diode (PD) to detect the modulated signal. We tested the system under extreme conditions including mechanical stresses similar to those experienced during a launch on SpaceX Falcon-9 vehicle, with a realistic spectrum of mechanical vibrations (up to 10 G), the temperature variation (between –40 and 80 °C), and X-ray irradiation ranges (up to 1 Mrad). All of these values were within the expected values (or even much higher) for a Low Earth Orbit (LEO) mission. The results demonstrate that the OWC system can be suitable for use in space applications.
- 11 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Radio Frequency Identification
- Vol. 8, 601-608
High-Speed Optical Wireless System for Extreme Space Conditions
In this paper, we present and deeply characterize a high-speed Optical Wireless Communication (OWC) system designed for use in space applications that operates at 1 Gbit/s over a directed optical link for a point-to-point link inside a 3U CubeSat. The OWC transmitter is equipped with a Vertical Cavity Surface Emitting Laser (VCSEL) that emits at 850 nm, whilst the receiver uses a PIN Photo-Diode (PD) to detect the modulated signal. We tested the system under extreme conditions including mechanical stresses similar to those experienced during a launch on SpaceX Falcon-9 vehicle, with a realistic spectrum of mechanical vibrations (up to 10 G), the temperature variation (between –40 and 80 °C), and X-ray irradiation ranges (up to 1 Mrad). All of these values were within the expected values (or even much higher) for a Low Earth Orbit (LEO) mission. The results demonstrate that the OWC system can be suitable for use in space applications.
- Top Cited PapersOpen Access
- 1 May 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (05) , P05064
Development of the CMS detector for the CERN LHC Run 3
Since the initial data taking of the CERN LHC, the CMS experiment has undergone substantial upgrades and improvements. This paper discusses the CMS detector as it is configured for the third data-taking period of the CERN LHC, Run 3, which started in 2022. The entire silicon pixel tracking detector was replaced. A new powering system for the superconducting solenoid was installed. The electronics of the hadron calorimeter was upgraded. All the muon electronic systems were upgraded, and new muon detector stations were added, including a gas electron multiplier detector. The precision proton spectrometer was upgraded. The dedicated luminosity detectors and the beam loss monitor were refurbished. Substantial improvements to the trigger, data acquisition, software, and computing systems were also implemented, including a new hybrid CPU/GPU farm for the high-level trigger.
- 1 May 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (05) , P05064
Top Cited PapersOpen AccessDevelopment of the CMS detector for the CERN LHC Run 3
Since the initial data taking of the CERN LHC, the CMS experiment has undergone substantial upgrades and improvements. This paper discusses the CMS detector as it is configured for the third data-taking period of the CERN LHC, Run 3, which started in 2022. The entire silicon pixel tracking detector was replaced. A new powering system for the superconducting solenoid was installed. The electronics of the hadron calorimeter was upgraded. All the muon electronic systems were upgraded, and new muon detector stations were added, including a gas electron multiplier detector. The precision proton spectrometer was upgraded. The dedicated luminosity detectors and the beam loss monitor were refurbished. Substantial improvements to the trigger, data acquisition, software, and computing systems were also implemented, including a new hybrid CPU/GPU farm for the high-level trigger.