FHFelix Hagemann

Felix Hagemann

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Felix Hagemann has a total of 301 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Pulse shape simulation for the reduced charge collection layer in p-type high-purity germanium detectors

    by P. Zhang, W. Dai, Q. Zhang, F. Hagemann, O. Schulz, C. Alvarez-Garcia, L. Yang, Q. Yue, Z. Zeng, J. Cheng, et al.

    P -type high-purity germanium (HPGe) detectors are widely used across many scientific domains, and current data analysis methods have served well in many use cases. However, applications like low-background experiments that search for rare physics, such as dark matter, neutrinoless double-beta decay, and coherent elastic neutrino-nucleus scattering, could profit a lot from a more detailed understanding of the detector response close to the surface. The outer $$n^+$$ n + electrode of the p -type HPGe detector forms a layer with reduced charge collection, and events originating here can be a critical background source in such experiments. If the difference in detector pulse shape between detector surface and bulk events is known, it can be used to identify and veto these background events. However, a faithful simulation of the detector response in this surface region is difficult and has not been available as a standard method so far. We present a novel three-dimensional pulse shape simulation method for this reduced charge collection (RCC) layer. We have implemented this method as a new feature in the open-source simulation package SolidStateDetectors.jl and show a validation of the numerical simulation results with analytical calculations. An experimental study using a p -type HPGe detector also validates our approach. The current implementation supports p -type HPGe detectors of fairly arbitrary geometry, but is easily adaptable to n -type detectors by adjusting the impurity density profile of the layer. It should also be adaptable to other semiconductor materials in a straightforward fashion.


  • Depth calibration of double-sided strip germanium detectors for the compton spectrometer and imager satellite

    by Field R. Rogers, Sean N. Pike, Samer Alnussirat, Robin Anthony-Petersen, Steven E. Boggs, Felix Hagemann, Sophia E. Haight, Alyson Joens, Carolyn Kierans, Alexander Lowell, et al.


  • Top Cited Papers
    Open Access

    First Results on the Search for Lepton Number Violating Neutrinoless Double- β Decay with the LEGEND-200 Experiment

    by H Acharya, N Ackermann, M Agostini, A Alexander, C Andreoiu, G R Araujo, F T Avignone, M Babicz, W Bae, A M Bakalyarov, et al.

    The LEGEND Collaboration is searching for neutrinoless double-beta ( 0 ν β β ) decay by operating high-purity germanium detectors enriched in Ge 76 in a low-background liquid argon environment. Building on key technological innovations from the GERmanium Detector Array (GERDA) experiment and the MAJORANA DEMONSTRATOR experiment, LEGEND-200 has performed a first 0 ν β β decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of 0.5 − 0.2 + 0.3 cts / ( keV ton yr ) in the 0 ν β β decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of 2.8 × 10 26 yr on the half-life of 0 ν β β decay, reveals no evidence for a signal and sets a new observed lower limit at T 1 / 2 0 ν > 1.9 × 10 26 yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range m β β < 75 – 200 meV , depending on the adopted nuclear matrix element.


  • Open Access

    Publisher Erratum: A novel wide-angle Compton Scanner setup to study bulk events in germanium detectors

    by Iris Abt, Chris Gooch, Felix Hagemann, Lukas Hauertmann, David Hervas Aguilar, Xiang Liu, Oliver Schulz, Martin Schuster, Anna Julia Zsigmond


  • Open Access

    A novel wide-angle Compton Scanner setup to study bulk events in germanium detectors

    by Iris Abt, Chris Gooch, Felix Hagemann, Lukas Hauertmann, David Hervas Aguilar, Xiang Liu, Oliver Schulz, Martin Schuster, Anna Julia J. Zsigmond

    A novel Compton Scanner setup has been built, commissioned and operated at the Max-Planck-Institute for Physics in Munich to collect pulses from bulk events in high-purity germanium detectors for pulse shape studies. In this fully automated setup, the detector under test is irradiated from the top with 661.660 keV gammas, some of which Compton scatter inside the detector. The interaction points in the detector can be reconstructed when the scattered gammas are detected with a pixelated camera placed at the side of the detector. The wide range of accepted Compton angles results in shorter measurement times in comparison to similar setups where only perpendicularly scattered gammas are selected by slit collimators. In this paper, the construction of the Compton Scanner, its alignment and the procedure to reconstruct interaction points in the germanium detector are described in detail. The creation of a first pulse shape library for an n-type segmented point-contact germanium detector is described. The spatial reconstruction along the beam axis is validated by a comparison to measured surface pulses. A first comparison of Compton Scanner pulses to simulated pulses is presented to demonstrate the power of the Compton Scanner to test simulation inputs and models.


  • Open Access

    A novel wide-angle Compton Scanner setup to study bulk events in germanium detectors

    by I. Abt, C. Gooch, F. Hagemann, L. Hauertmann, D. Hervas Aguilar, X. Liu, O. Schulz, M. Schuster, A. J. Zsigmond

    A novel Compton Scanner setup has been built, commissioned and operated at the Max-Planck-Institute for Physics in Munich to collect pulses from bulk events in high-purity germanium detectors for pulse shape studies. In this fully automated setup, the detector under test is irradiated from the top with 661.660 keV gammas, some of which Compton scatter inside the detector. The interaction points in the detector can be reconstructed when the scattered gammas are detected with a pixelated camera placed at the side of the detector. The wide range of accepted Compton angles results in shorter measurement times in comparison to similar setups where only perpendicularly scattered gammas are selected by slit collimators. In this paper, the construction of the Compton Scanner, its alignment and the procedure to reconstruct interaction points in the germanium detector are described in detail. The creation of a first pulse shape library for an n-type segmented point-contact germanium detector is described. The spatial reconstruction along the beam axis is validated by a comparison to measured surface pulses. A first comparison of Compton Scanner pulses to simulated pulses is presented to demonstrate the power of the Compton Scanner to test simulation inputs and models.