Martin Skeppholm
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Martin Skeppholm has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Claes Olerud
Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
7 shared publications- Anna MacDowall
Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
3 shared publications - Catarina Marques
Department of Surgical Sciences, Uppsala University Hospital, Uppsala, Sweden
2 shared publications - Nuno Canto Moreira
Pediatric Radiology Section, Department of Clinical Neuroscience (CNS), K8, Karolinska Universitetssjukhuset Solna, Stockholm, Sweden
2 shared publications Catarina Ingebro
1 shared publication- Claes Olerud
Department of Surgical Sciences, Uppsala University Hospital, 751 85 Uppsala, Sweden
1 shared publication
Latest Publications
- Open Access
- 20 January 2021
- Published by Springer Nature in European Spine Journal
- Vol. 30 (6) , 1662-1669
Unintended fusion in cervical artificial disk replacement: a prospective study on heterotopic ossification, progression, and clinical outcome, with 5-year follow-up
Purpose: Heterotopic ossification (HO) may cause unintended fusion in artificial disk replacement (ADR), failing to preserve motion. The reported incidence of HO varies hugely. This study aimed to determine prevalence of HO, progression, predisposing factors to occurrence and to progression, and potential effect on clinical outcomes. Methods: Eighty-three patients treated with ADRs for cervical radiculopathy at one or two segments were extracted from a previously published RCT. Of the 83 patients, 59 had remaining ADR (79 implants) and sufficiently high-quality X-rays at 5 years of follow-up to allow analysis. HO was graded on plain films according to Mehren/Suchomel. Prevalence, progression, predisposing factors and effect on clinical outcome (Neck Disability Index—NDI) were analyzed. Results: At 2 years, HO was seen in 46/55 ADR implants (84%), severe enough to affect mobility in 27/55 (49%). At 5 years, HO was seen in 92% of 79 implants, severe in 71%. Male sex was a predisposing factor to HO. No predisposing factors to progression were identified. NDI was not affected by the severity of HO. Conclusion: Almost all ADR implants in our study have HO at 5 years of follow-up. Male sex is a risk factor. Severe HO did not affect clinical outcome. Trial registration: Study registered at ISRCTN (registration number: 44347115).
- 20 January 2021
- Published by Springer Nature in European Spine Journal
- Vol. 30 (6) , 1662-1669
Open AccessUnintended fusion in cervical artificial disk replacement: a prospective study on heterotopic ossification, progression, and clinical outcome, with 5-year follow-up
Purpose: Heterotopic ossification (HO) may cause unintended fusion in artificial disk replacement (ADR), failing to preserve motion. The reported incidence of HO varies hugely. This study aimed to determine prevalence of HO, progression, predisposing factors to occurrence and to progression, and potential effect on clinical outcomes. Methods: Eighty-three patients treated with ADRs for cervical radiculopathy at one or two segments were extracted from a previously published RCT. Of the 83 patients, 59 had remaining ADR (79 implants) and sufficiently high-quality X-rays at 5 years of follow-up to allow analysis. HO was graded on plain films according to Mehren/Suchomel. Prevalence, progression, predisposing factors and effect on clinical outcome (Neck Disability Index—NDI) were analyzed. Results: At 2 years, HO was seen in 46/55 ADR implants (84%), severe enough to affect mobility in 27/55 (49%). At 5 years, HO was seen in 92% of 79 implants, severe in 71%. Male sex was a predisposing factor to HO. No predisposing factors to progression were identified. NDI was not affected by the severity of HO. Conclusion: Almost all ADR implants in our study have HO at 5 years of follow-up. Male sex is a risk factor. Severe HO did not affect clinical outcome. Trial registration: Study registered at ISRCTN (registration number: 44347115).
- Open Access
- 30 April 2020
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 14 (2) , 169-176
Accuracy and Reliability of X-ray Measurements in the Cervical Spine
Study Design: This study is a post hoc analysis of a multicenter prospective randomized controlled trial which compared artificial disc replacement and anterior cervical discectomy and fusion.Purpose: Useful radiographic parameters for assessing cervical alignment include the Cobb angles, T1 slope (T1S), occipitocervical inclination (OCI), K-line tilt (KLT), and cervical sagittal vertical axis (cSVA). This study aimed to determine measurement accuracy and reliability for these parameters.Overview of Literature: Various authors have assessed repeatability by comparing different methods of measurement, but knowledge of measurement error and minimal detectable change is scarce.Methods: We evaluated 758 lateral cervical radiographs. One medical student and one spine surgeon (i.e., measured ×2 within 4 weeks) independently measured the parameters obtaining 5,850 values. Standard error of measurement (SEm) and minimum detectable change (MDC) were calculated for each parameter. The accuracy and reliability of the Cobb angle measurements were calculated for the different types of angles: cervical lordosis, prosthesis angle, segmental angle with two bone surfaces (SABB), and segmental angle with one bone and one metal surface. Reliability was determined with intraclass correlation coefficient (ICC).Results: SEm was 1.8° and MDC was 5.0° for the Cobb angle, with an intraobserver/interobserver ICC of 0.958/0.886. All the different subtypes of Cobb angles had an ICC higher than 0.950, except SABB (intraobserver/interobserver ICC of 0.922/0.716). The most accurate and reliable measurement was for KLT.Conclusions: This study provides normative data on SEm and MDC for Cobb angles, T1S, KLT, OCI, and cSVA in cervical lateral radiographs. Reliability was excellent for all parameters except SABB (e.g., good).
- 30 April 2020
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 14 (2) , 169-176
Open AccessAccuracy and Reliability of X-ray Measurements in the Cervical Spine
Study Design: This study is a post hoc analysis of a multicenter prospective randomized controlled trial which compared artificial disc replacement and anterior cervical discectomy and fusion.Purpose: Useful radiographic parameters for assessing cervical alignment include the Cobb angles, T1 slope (T1S), occipitocervical inclination (OCI), K-line tilt (KLT), and cervical sagittal vertical axis (cSVA). This study aimed to determine measurement accuracy and reliability for these parameters.Overview of Literature: Various authors have assessed repeatability by comparing different methods of measurement, but knowledge of measurement error and minimal detectable change is scarce.Methods: We evaluated 758 lateral cervical radiographs. One medical student and one spine surgeon (i.e., measured ×2 within 4 weeks) independently measured the parameters obtaining 5,850 values. Standard error of measurement (SEm) and minimum detectable change (MDC) were calculated for each parameter. The accuracy and reliability of the Cobb angle measurements were calculated for the different types of angles: cervical lordosis, prosthesis angle, segmental angle with two bone surfaces (SABB), and segmental angle with one bone and one metal surface. Reliability was determined with intraclass correlation coefficient (ICC).Results: SEm was 1.8° and MDC was 5.0° for the Cobb angle, with an intraobserver/interobserver ICC of 0.958/0.886. All the different subtypes of Cobb angles had an ICC higher than 0.950, except SABB (intraobserver/interobserver ICC of 0.922/0.716). The most accurate and reliable measurement was for KLT.Conclusions: This study provides normative data on SEm and MDC for Cobb angles, T1S, KLT, OCI, and cSVA in cervical lateral radiographs. Reliability was excellent for all parameters except SABB (e.g., good).
- 1 June 2017
- Published by Elsevier in The Spine Journal
- Vol. 17 (6) , 790-798
The association between preoperative mental distress and patient-reported outcome measures in patients treated surgically for cervical radiculopathy
- 1 June 2017
- Published by Elsevier in The Spine Journal
- Vol. 17 (6) , 790-798
The association between preoperative mental distress and patient-reported outcome measures in patients treated surgically for cervical radiculopathy
- Open Access
- 3 April 2017
- Published by Uppsala Medical Society in Upsala Journal of Medical Sciences
- Vol. 122 (2) , 99-107
Anxiety and depression affect pain drawings in cervical degenerative disc disease
Pain drawings have been frequently used in the preoperative evaluation of spine patients. Until now most investigations have focused on low back pain patients, even though pain drawings are used in neck pain patients as well. The aims of this study were to investigate the pain drawing and its association to preoperative demographics, psychological impairment, and pain intensity. We carried out a post hoc analysis of a randomized controlled trial, comparing cervical disc replacement to fusion for radiculopathy related to degenerative disc disease. Preoperatively the patients completed a pain drawing, the Hospital Anxiety and Depression Scale (HADS), and a visual analogue scale (VAS). The pain drawing was evaluated according to four established methods, now modified for cervical conditions. Comparisons were made between the pain drawing and age, sex, smoking, and employment status as well as HADS and VAS. Included were 151 patients, mean age of 47 years, female/male: 78/73. Pain drawing results were not affected by age, sex, smoking, and employment status. Patients with non-neurogenic pain drawings according to the modified method by Ransford had higher points on HADS-anxiety, HADS-depression, and HADS-total. Patients with markings in the head region had higher score on HADS-depression. Markings in the neck and lower arm region were associated with high values of VAS-neck and VAS-arm. Pain drawings were affected by both pain intensity and anxiety/depression in cervical spine patients. Therefore, the pain drawing can be a useful tool when interpreting the patients' pain in correlation to psychological impairment and pain location.
- 3 April 2017
- Published by Uppsala Medical Society in Upsala Journal of Medical Sciences
- Vol. 122 (2) , 99-107
Open AccessAnxiety and depression affect pain drawings in cervical degenerative disc disease
Pain drawings have been frequently used in the preoperative evaluation of spine patients. Until now most investigations have focused on low back pain patients, even though pain drawings are used in neck pain patients as well. The aims of this study were to investigate the pain drawing and its association to preoperative demographics, psychological impairment, and pain intensity. We carried out a post hoc analysis of a randomized controlled trial, comparing cervical disc replacement to fusion for radiculopathy related to degenerative disc disease. Preoperatively the patients completed a pain drawing, the Hospital Anxiety and Depression Scale (HADS), and a visual analogue scale (VAS). The pain drawing was evaluated according to four established methods, now modified for cervical conditions. Comparisons were made between the pain drawing and age, sex, smoking, and employment status as well as HADS and VAS. Included were 151 patients, mean age of 47 years, female/male: 78/73. Pain drawing results were not affected by age, sex, smoking, and employment status. Patients with non-neurogenic pain drawings according to the modified method by Ransford had higher points on HADS-anxiety, HADS-depression, and HADS-total. Patients with markings in the head region had higher score on HADS-depression. Markings in the neck and lower arm region were associated with high values of VAS-neck and VAS-arm. Pain drawings were affected by both pain intensity and anxiety/depression in cervical spine patients. Therefore, the pain drawing can be a useful tool when interpreting the patients' pain in correlation to psychological impairment and pain location.
- 1 September 2015
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 23 (3) , 383-389
Evaluation of mobility and stability in the Discover artificial disc: an in vivo motion study using high-accuracy 3D CT data
OBJECT: Artificial disc replacement (ADR) devices are unlike implants used in cervical fusion in that they are continuously exposed to stress not only within the implant site but also at their site of attachment to the adjacent vertebra. An imaging technique with higher accuracy than plain radiography and with the possibility of 3D visualization would provide more detailed information about the motion quality and stability of the implant in relation to the vertebrae. Such high-accuracy studies have previously been conducted with radiostereometric analysis (RSA), which requires implantation of tantalum markers in the adjacent vertebrae. The aim of this study was to evaluate in vivo motion and stability of implanted artificial discs. A noninvasive analysis was performed with CT, with an accuracy higher than that of plain radiographs and almost as high as RSA in cervical spine. METHODS: Twenty-eight patients with ADR were included from a larger cohort of a randomized controlled trial comparing treatment of cervical radiculopathy with ADR or anterior cervical decompression and fusion. Surgical levels included C4–7; 18 patients had 1-level surgery and 10 patients had 2-level surgery. Follow-up time ranged from 19 to 50 months, with an average of 40 months. Two CT volumes of the cervical spine, 1 in flexion and 1 in extension, were obtained in each patient and then spatially registered using a customized imaging tool, previously used and validated for the cervical spine. Motion between the components in the artificial disc, as well as motion between the components and adjacent vertebrae, were calculated in 3 planes. Intraclass correlation (ICC) between independent observers and repeatability of the method were also calculated. RESULTS: Intrinsic motion, expressed as degrees in rotation and millimeters in translation, was detectable in a majority of the ADRs. In the sagittal plane, in which the flexion/extension was performed, sagittal rotation ranged between 0.2° and 15.8° and translation between 0.0 and 5.5 mm. Eight percent of the ADRs were classified as unstable, as motion between at least 1 of the components and the adjacent vertebra was detected. Five percent were classified as ankylotic, with no detectable motion, and another 8% showed very limited motion due to heterotopic ossification. Repeatability for the motion in the sagittal plane was calculated to be 1.30° for rotation and 1.29 mm for translation (95% confidence level), ICC 0.99 and 0.84, respectively. All 3 patients with unstable devices had undergone 1-level ADRs at C5–6. They all underwent revision surgery due to increased neck pain, and instability was established during the surgery. CONCLUSIONS: The majority of the artificial discs in this study showed intrinsic mobility several years after implantation and were also shown to be properly attached. Implant instability was detected in 8% of patients and, as all of these patients underwent revision surgery due to increasing neck pain, this might be a more serious problem than heterotopic bone formation.
- 1 September 2015
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 23 (3) , 383-389
Evaluation of mobility and stability in the Discover artificial disc: an in vivo motion study using high-accuracy 3D CT data
OBJECT: Artificial disc replacement (ADR) devices are unlike implants used in cervical fusion in that they are continuously exposed to stress not only within the implant site but also at their site of attachment to the adjacent vertebra. An imaging technique with higher accuracy than plain radiography and with the possibility of 3D visualization would provide more detailed information about the motion quality and stability of the implant in relation to the vertebrae. Such high-accuracy studies have previously been conducted with radiostereometric analysis (RSA), which requires implantation of tantalum markers in the adjacent vertebrae. The aim of this study was to evaluate in vivo motion and stability of implanted artificial discs. A noninvasive analysis was performed with CT, with an accuracy higher than that of plain radiographs and almost as high as RSA in cervical spine. METHODS: Twenty-eight patients with ADR were included from a larger cohort of a randomized controlled trial comparing treatment of cervical radiculopathy with ADR or anterior cervical decompression and fusion. Surgical levels included C4–7; 18 patients had 1-level surgery and 10 patients had 2-level surgery. Follow-up time ranged from 19 to 50 months, with an average of 40 months. Two CT volumes of the cervical spine, 1 in flexion and 1 in extension, were obtained in each patient and then spatially registered using a customized imaging tool, previously used and validated for the cervical spine. Motion between the components in the artificial disc, as well as motion between the components and adjacent vertebrae, were calculated in 3 planes. Intraclass correlation (ICC) between independent observers and repeatability of the method were also calculated. RESULTS: Intrinsic motion, expressed as degrees in rotation and millimeters in translation, was detectable in a majority of the ADRs. In the sagittal plane, in which the flexion/extension was performed, sagittal rotation ranged between 0.2° and 15.8° and translation between 0.0 and 5.5 mm. Eight percent of the ADRs were classified as unstable, as motion between at least 1 of the components and the adjacent vertebra was detected. Five percent were classified as ankylotic, with no detectable motion, and another 8% showed very limited motion due to heterotopic ossification. Repeatability for the motion in the sagittal plane was calculated to be 1.30° for rotation and 1.29 mm for translation (95% confidence level), ICC 0.99 and 0.84, respectively. All 3 patients with unstable devices had undergone 1-level ADRs at C5–6. They all underwent revision surgery due to increased neck pain, and instability was established during the surgery. CONCLUSIONS: The majority of the artificial discs in this study showed intrinsic mobility several years after implantation and were also shown to be properly attached. Implant instability was detected in 8% of patients and, as all of these patients underwent revision surgery due to increasing neck pain, this might be a more serious problem than heterotopic bone formation.
- 1 June 2015
- Published by Elsevier in The Spine Journal
- Vol. 15 (6) , 1284-1294
The Discover artificial disc replacement versus fusion in cervical radiculopathy—a randomized controlled outcome trial with 2-year follow-up
- 1 June 2015
- Published by Elsevier in The Spine Journal
- Vol. 15 (6) , 1284-1294
The Discover artificial disc replacement versus fusion in cervical radiculopathy—a randomized controlled outcome trial with 2-year follow-up
- 1 November 2013
- Published by Wolters Kluwer Health in Spine
- Vol. 38 (24) , E1507-E1510
Comparison of Dysphagia Between Cervical Artificial Disc Replacement and Fusion
Prospective randomized controlled trial. To determine and explain any differences in self-reported dysphagia between patients treated with artificial disc replacement and anterior cervical decompression and fusion (ACDF). Dysphagia after anterior cervical spine surgery has in previous studies been evaluated regarding different influencing factors. Surgical technique, number of treated levels, and type of implant has been shown to be of possible importance. One hundred thirty-six patients from a randomized controlled trial between artificial disc replacement and ACDF in 1 or 2 surgical levels were evaluated regarding dysphagia. Evaluation was done with the dysphagia short questionnaire preoperatively, at 4 weeks, 3 months, and 1 and 2 years postoperatively. Reconstruction in the artificial disc replacement group was performed with the Discover artificial disc. Bone graft and anterior plating was used in the ACDF group. Type of implant was blinded to the patients and the surgeon until time of implantation. Demographics and dysphagia short questionnaire levels were similar in both groups preoperative. At 4 weeks of follow-up postoperatively, dysphagia was significantly higher in both groups than baseline levels, P < 0.01. No significant differences were seen between the groups until follow-up at 2 years, which showed significantly higher dysphagia short questionnaire levels in the ACDF group, P = 0.04. The difference was statistically significant in both patients treated with 1- and 2-level surgery, P = 0.029 and P = 0.032, respectively. A logistic regression model showed a stronger association to type of implant than to number of surgical levels. Duration of surgery was highly associated to number of surgical levels but did not differ significantly between types of implant. Long-term postoperative dysphagia could be explained by bulk of implant or decreased motion in the cervical spine. However, it is doubtful if differences between the groups in this study can be interpreted as a clinically important difference. 2.
- 1 November 2013
- Published by Wolters Kluwer Health in Spine
- Vol. 38 (24) , E1507-E1510
Comparison of Dysphagia Between Cervical Artificial Disc Replacement and Fusion
Prospective randomized controlled trial. To determine and explain any differences in self-reported dysphagia between patients treated with artificial disc replacement and anterior cervical decompression and fusion (ACDF). Dysphagia after anterior cervical spine surgery has in previous studies been evaluated regarding different influencing factors. Surgical technique, number of treated levels, and type of implant has been shown to be of possible importance. One hundred thirty-six patients from a randomized controlled trial between artificial disc replacement and ACDF in 1 or 2 surgical levels were evaluated regarding dysphagia. Evaluation was done with the dysphagia short questionnaire preoperatively, at 4 weeks, 3 months, and 1 and 2 years postoperatively. Reconstruction in the artificial disc replacement group was performed with the Discover artificial disc. Bone graft and anterior plating was used in the ACDF group. Type of implant was blinded to the patients and the surgeon until time of implantation. Demographics and dysphagia short questionnaire levels were similar in both groups preoperative. At 4 weeks of follow-up postoperatively, dysphagia was significantly higher in both groups than baseline levels, P < 0.01. No significant differences were seen between the groups until follow-up at 2 years, which showed significantly higher dysphagia short questionnaire levels in the ACDF group, P = 0.04. The difference was statistically significant in both patients treated with 1- and 2-level surgery, P = 0.029 and P = 0.032, respectively. A logistic regression model showed a stronger association to type of implant than to number of surgical levels. Duration of surgery was highly associated to number of surgical levels but did not differ significantly between types of implant. Long-term postoperative dysphagia could be explained by bulk of implant or decreased motion in the cervical spine. However, it is doubtful if differences between the groups in this study can be interpreted as a clinically important difference. 2.
- 1 May 2012
- Published by Wolters Kluwer Health in Spine
- Vol. 37 (11) , 996-1002
The Dysphagia Short Questionnaire
Prospective clinical validation study of questionnaire to assess dysphagia. To test validity and reliability of Dysphagia Short Questionnaire (DSQ), and also to determine levels of dysphagia over time after anterior cervical spine surgery (ACSS). Dysphagia is common after ACSS but reports on the incidence vary widely between 1% and 79%, indicating an evaluation problem. Several tools for evaluation of dysphagia exist but common features are that they are cumbersome to use and usually are designed for patients with neurological or malignant diseases in the neck region. Others are not validated, for example, the Bazaz score. There is, thus, a need for a more adapted tool to evaluate dysphagia in patients undergoing ACSS. The DSQ was constructed in collaboration with a group of ear-nose-and-throat specialists. In a first validation study, 45 patients with stationary dysphagia for various reasons completed the DSQ twice 2 weeks apart, the M.D. Anderson Dysphagia Inventory (MDADI), the Bazaz score, and a quality-of-life score, the EQ-5D. To evaluate the utility of the DSQ, a second validation study was performed, where 111 subjects undergoing ACSS for degenerative disk disease completed the form preoperatively and at 4 weeks, 3 months, and 1 year after surgery. In the first study, the DSQ correlated to MDADI (r = 0.59) and showed good reproducibility. The Bazaz score did not correlate to the DSQ, the MDADI, or the EQ-5 D. In the second study, dysphagia was present in a few patients already preoperatively. At 4 weeks, 85% of the patients reported dysphagia. The level had dropped significantly at 3 months and had returned to baseline levels at 1 year. We consider the DSQ to be a validated tool for the assessment of dysphagia in ACSS patients. Dysphagia after ACSS for cervical spondylosis is common but the symptoms on a group level are not very severe and are also temporary.
- 1 May 2012
- Published by Wolters Kluwer Health in Spine
- Vol. 37 (11) , 996-1002
The Dysphagia Short Questionnaire
Prospective clinical validation study of questionnaire to assess dysphagia. To test validity and reliability of Dysphagia Short Questionnaire (DSQ), and also to determine levels of dysphagia over time after anterior cervical spine surgery (ACSS). Dysphagia is common after ACSS but reports on the incidence vary widely between 1% and 79%, indicating an evaluation problem. Several tools for evaluation of dysphagia exist but common features are that they are cumbersome to use and usually are designed for patients with neurological or malignant diseases in the neck region. Others are not validated, for example, the Bazaz score. There is, thus, a need for a more adapted tool to evaluate dysphagia in patients undergoing ACSS. The DSQ was constructed in collaboration with a group of ear-nose-and-throat specialists. In a first validation study, 45 patients with stationary dysphagia for various reasons completed the DSQ twice 2 weeks apart, the M.D. Anderson Dysphagia Inventory (MDADI), the Bazaz score, and a quality-of-life score, the EQ-5D. To evaluate the utility of the DSQ, a second validation study was performed, where 111 subjects undergoing ACSS for degenerative disk disease completed the form preoperatively and at 4 weeks, 3 months, and 1 year after surgery. In the first study, the DSQ correlated to MDADI (r = 0.59) and showed good reproducibility. The Bazaz score did not correlate to the DSQ, the MDADI, or the EQ-5 D. In the second study, dysphagia was present in a few patients already preoperatively. At 4 weeks, 85% of the patients reported dysphagia. The level had dropped significantly at 3 months and had returned to baseline levels at 1 year. We consider the DSQ to be a validated tool for the assessment of dysphagia in ACSS patients. Dysphagia after ACSS for cervical spondylosis is common but the symptoms on a group level are not very severe and are also temporary.