Manpreet Kaur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Manpreet Kaur has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Jeewan S Titiyal
Cornea, Cataract and Refractive Surgery Services, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
6 shared publicationsVaibhav Namdev
Cornea, Cataract & Refractive Surgery Services, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
5 shared publicationsJeewan S. Titiyal
Cornea, Cataract & Refractive Surgery Services, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
3 shared publications- Jeewan Singh Titiyal
Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi, India
2 shared publications Manvi Bansal
Cornea, Cataract and Refractive Surgery Services, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
2 shared publicationsRishav Raj
Cornea, Cataract and Refractive Surgery Services, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
2 shared publications
Latest Publications
- 20 October 2026
- Published by Elsevier in Ophthalmology
Corneal Ring of Trauma: Iatrogenic Endothelial Damage during Laser Capsulotomy
- 20 October 2026
- Published by Elsevier in Ophthalmology
Corneal Ring of Trauma: Iatrogenic Endothelial Damage during Laser Capsulotomy
- 14 October 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
Corneal wound hydration-induced gaping of a femtosecond intrastromal toric alignment mark
Was not provided for this article.
- 14 October 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
Corneal wound hydration-induced gaping of a femtosecond intrastromal toric alignment mark
Was not provided for this article.
- 28 September 2026
- Published by Springer Nature in Eye
- p. 1-2
Annular subcapsular opacities with peri-aquaport clear zone after inverse phakic intraocular lens
- 28 September 2026
- Published by Springer Nature in Eye
- p. 1-2
Annular subcapsular opacities with peri-aquaport clear zone after inverse phakic intraocular lens
- 10 August 2026
- Published by Springer Nature in Eye
- p. 1-2
Localised lenticular hydrodissection due to iatrogenic needle injury: OCT to the rescue
- 10 August 2026
- Published by Springer Nature in Eye
- p. 1-2
Localised lenticular hydrodissection due to iatrogenic needle injury: OCT to the rescue
- Open Access
- 20 May 2026
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 74 (Suppl 2) , S203-S208
Anterior segment optical coherence tomography-guided assessment of wound healing after cyanoacrylate glue patch for corneal perforations
Purpose: To evaluate wound healing after cyanoacrylate glue patch (CGP) application in corneal perforations using anterior segment optical coherence tomography (ASOCT). Design: Prospective interventional case series. Methods: Twenty-eight patients with corneal perforations (<4 mm) underwent CGP application. The primary outcome measure was wound healing pattern on ASOCT after CGP application. Secondary outcomes were time to removal of CGP and anatomical success. Follow-up was performed on POD 1 and every 2 weeks till CGP removal. Results: Three distinct wound healing patterns were observed on ASOCT: Type 1 with corrugated hyper-reflective mass corresponding to CGP with underlying shadowing, Type 2 pattern with ongoing stromal regeneration without continuity with surrounding healthy cornea, and Type 3 with complete stromal regeneration beneath the CGP continuous with surrounding cornea. On POD 1, 100% cases had type 1 pattern. At 2 weeks, 85.7% had type 2; 14.3% had type 1 pattern. At 4 weeks, 35.7% cases had type 3 and 64.3% had type 2 pattern. Five cases underwent early glue removal (type 2 pattern) at 31.8 ± 2.5 days because of CGP intolerance; of these, 40% (2/5) developed a leak and required reapplication of CGP. Total 82.1% cases achieved type 3 pattern by 8 weeks. CGP was removed after documentation of type 3 pattern in 82.1% cases at 41.7 ± 9.2 days; no case developed wound leak. Conclusions: ASOCT is a useful adjunct to objectively monitor wound healing after CGP and guide regarding optimal timing for its removal, with type 3 pattern correlating with higher anatomical success.
- 20 May 2026
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 74 (Suppl 2) , S203-S208
Open AccessAnterior segment optical coherence tomography-guided assessment of wound healing after cyanoacrylate glue patch for corneal perforations
Purpose: To evaluate wound healing after cyanoacrylate glue patch (CGP) application in corneal perforations using anterior segment optical coherence tomography (ASOCT). Design: Prospective interventional case series. Methods: Twenty-eight patients with corneal perforations (<4 mm) underwent CGP application. The primary outcome measure was wound healing pattern on ASOCT after CGP application. Secondary outcomes were time to removal of CGP and anatomical success. Follow-up was performed on POD 1 and every 2 weeks till CGP removal. Results: Three distinct wound healing patterns were observed on ASOCT: Type 1 with corrugated hyper-reflective mass corresponding to CGP with underlying shadowing, Type 2 pattern with ongoing stromal regeneration without continuity with surrounding healthy cornea, and Type 3 with complete stromal regeneration beneath the CGP continuous with surrounding cornea. On POD 1, 100% cases had type 1 pattern. At 2 weeks, 85.7% had type 2; 14.3% had type 1 pattern. At 4 weeks, 35.7% cases had type 3 and 64.3% had type 2 pattern. Five cases underwent early glue removal (type 2 pattern) at 31.8 ± 2.5 days because of CGP intolerance; of these, 40% (2/5) developed a leak and required reapplication of CGP. Total 82.1% cases achieved type 3 pattern by 8 weeks. CGP was removed after documentation of type 3 pattern in 82.1% cases at 41.7 ± 9.2 days; no case developed wound leak. Conclusions: ASOCT is a useful adjunct to objectively monitor wound healing after CGP and guide regarding optimal timing for its removal, with type 3 pattern correlating with higher anatomical success.
- Open Access
- 19 September 2025
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 73 (12) , 1779-1785
Intraoperative optical coherence tomography-guided compression sutures in acute corneal hydrops – Surgical technique and review of literature
Purpose: To describe outcomes of the intraoperative optical coherence tomography (iOCT)-guided technique of partial-thickness compression sutures (PTS) in acute corneal hydrops. We also provide a comprehensive review of literature of the outcomes of compression sutures in acute hydrops. Methods: This study involves prospective interventional case series of patients with keratoconus and acute corneal hydrops. iOCT was used to assess the morphological features of the hydrops, observe surgical dynamics during PTS, titrate the magnitude of suture tightness by observing the stromal compaction and minimisation of intrastromal fluid clefts, and confirm the depth of suture placement (intended at 50–60%). The primary outcome measure was time to resolution of hydrops. Suture removal was planned after documenting stability of corneal thickness. Results: Seven patients (4 males, 3 females; median age 16 years) underwent iOCT-guided PTS with intracameral air. The time interval between onset of hydrops and PTS ranged from 1 to 12 weeks. The preoperative corneal thickness ranged from 1120 to 2363 µm. The initial depth of suture placement on iOCT was observed to be <50%; progressive stromal compaction and collapse of intrastromal fluid pockets allowed deeper penetration with needle during subsequent suture placement. A decrease in separation of DM from stroma was noted; however, no case had on-table complete DM-stromal reattachment. Complete resolution of hydrops was observed by 2 weeks in all cases. Suture removal was performed in 5 cases at 8–12 weeks. Conclusion: iOCT helps titrate depth and tightness of compression sutures in real time to achieve on-table stromal compaction and minimization of intrastromal clefts, with fast resolution of acute hydrops.
- 19 September 2025
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 73 (12) , 1779-1785
Open AccessIntraoperative optical coherence tomography-guided compression sutures in acute corneal hydrops – Surgical technique and review of literature
Purpose: To describe outcomes of the intraoperative optical coherence tomography (iOCT)-guided technique of partial-thickness compression sutures (PTS) in acute corneal hydrops. We also provide a comprehensive review of literature of the outcomes of compression sutures in acute hydrops. Methods: This study involves prospective interventional case series of patients with keratoconus and acute corneal hydrops. iOCT was used to assess the morphological features of the hydrops, observe surgical dynamics during PTS, titrate the magnitude of suture tightness by observing the stromal compaction and minimisation of intrastromal fluid clefts, and confirm the depth of suture placement (intended at 50–60%). The primary outcome measure was time to resolution of hydrops. Suture removal was planned after documenting stability of corneal thickness. Results: Seven patients (4 males, 3 females; median age 16 years) underwent iOCT-guided PTS with intracameral air. The time interval between onset of hydrops and PTS ranged from 1 to 12 weeks. The preoperative corneal thickness ranged from 1120 to 2363 µm. The initial depth of suture placement on iOCT was observed to be <50%; progressive stromal compaction and collapse of intrastromal fluid pockets allowed deeper penetration with needle during subsequent suture placement. A decrease in separation of DM from stroma was noted; however, no case had on-table complete DM-stromal reattachment. Complete resolution of hydrops was observed by 2 weeks in all cases. Suture removal was performed in 5 cases at 8–12 weeks. Conclusion: iOCT helps titrate depth and tightness of compression sutures in real time to achieve on-table stromal compaction and minimization of intrastromal clefts, with fast resolution of acute hydrops.
- 9 June 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (10) , 876-881
Outcomes of Intralenticular lens aspiration with glued Scleral fixated intraocular lens for Ectopia lentis in Marfan’s Syndrome
Purpose: To evaluate visual and anatomical outcomes of intralenticular lens aspiration (ILLA) with fibrin-glue assisted intrascleral haptic fixation of intraocular lens (glued-SFIOL) in Marfan syndrome patients with Ectopia lentis Setting: Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi Design: Ambispective observational case series Methods: Patients with Marfan syndrome and ectopia lentis who underwent ILLA with glued SFIOL from August 2021 to September 2022 were retrospectively enrolled in the study. Intraoperative surgical details were recorded and patients were prospectively followed up. Primary outcome measure was post-operative corrected distance visual acuity (CDVA) at 12 months. Secondary outcome measures were postoperative complications and residual refractive error at 12 months. Results: Forty-four eyes of 25 patients were enrolled. Mean age of patients was 12.52±6.6 years (14 males, 11 females). CDVA improved from 1.08±0.53 LogMAR pre-operatively to 0.68±0.49 LogMAR on POD-1 (p=0.012), 0.3±0.2 at 3 months (p=0.004) and 0.14±0.18 at 12 months (p=0.001). Moderate negative correlation was observed between age of presentation and post-operative CDVA at 12 months (r=-0.36, p=0.017). Group 2 (Age >10 years) had better CDVA at 3 (p=0.016) and 12 months (p=0.033) than Group 1 (Age ≤10 years). Post-operative complications included vitreous hemorrhage (11.36%), hypotony (4.34%), pupillary capture of IOL (6.5%), haptic extrusion through sclera (2.27%) and posterior dislocation of IOL (2.27%). No eye had clinically apparent pseudophakodonesis. Conclusion: ILLA with glued-SFIOL is a promising surgical technique for managing ectopia lentis with Marfan's syndrome. Younger age of presentation is associated with poorer postoperative visual outcomes.
- 9 June 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (10) , 876-881
Outcomes of Intralenticular lens aspiration with glued Scleral fixated intraocular lens for Ectopia lentis in Marfan’s Syndrome
Purpose: To evaluate visual and anatomical outcomes of intralenticular lens aspiration (ILLA) with fibrin-glue assisted intrascleral haptic fixation of intraocular lens (glued-SFIOL) in Marfan syndrome patients with Ectopia lentis Setting: Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi Design: Ambispective observational case series Methods: Patients with Marfan syndrome and ectopia lentis who underwent ILLA with glued SFIOL from August 2021 to September 2022 were retrospectively enrolled in the study. Intraoperative surgical details were recorded and patients were prospectively followed up. Primary outcome measure was post-operative corrected distance visual acuity (CDVA) at 12 months. Secondary outcome measures were postoperative complications and residual refractive error at 12 months. Results: Forty-four eyes of 25 patients were enrolled. Mean age of patients was 12.52±6.6 years (14 males, 11 females). CDVA improved from 1.08±0.53 LogMAR pre-operatively to 0.68±0.49 LogMAR on POD-1 (p=0.012), 0.3±0.2 at 3 months (p=0.004) and 0.14±0.18 at 12 months (p=0.001). Moderate negative correlation was observed between age of presentation and post-operative CDVA at 12 months (r=-0.36, p=0.017). Group 2 (Age >10 years) had better CDVA at 3 (p=0.016) and 12 months (p=0.033) than Group 1 (Age ≤10 years). Post-operative complications included vitreous hemorrhage (11.36%), hypotony (4.34%), pupillary capture of IOL (6.5%), haptic extrusion through sclera (2.27%) and posterior dislocation of IOL (2.27%). No eye had clinically apparent pseudophakodonesis. Conclusion: ILLA with glued-SFIOL is a promising surgical technique for managing ectopia lentis with Marfan's syndrome. Younger age of presentation is associated with poorer postoperative visual outcomes.
- Open Access
- 26 February 2025
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 73 (3) , 345-346
Commentary on: IOL dynamics after capsular tension ring implantation
- 26 February 2025
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 73 (3) , 345-346
Open AccessCommentary on: IOL dynamics after capsular tension ring implantation
- Open Access
- 26 February 2025
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 73 (3) , 402-403
Commentary on: Understanding IOL optic-posterior capsule dynamics
- 26 February 2025
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 73 (3) , 402-403
Open AccessCommentary on: Understanding IOL optic-posterior capsule dynamics
- Open Access
- 30 January 2025
- Published by Wolters Kluwer Health in Indian Journal of Ophthalmology - Case Reports
- Vol. 5 (1) , 3-5
Successful management of bilateral spontaneous delayed rotation of toric phakic intraocular lens
A young male in 20s underwent bilateral toric implantable collamer lens (ICL) implantation. The patient presented with diminution of vision in the right eye on postoperative day (POD) 7. On examination, a spontaneous ICL rotation of 90 degrees was observed, with vault of 677 microns. Re-alignment of ICL was performed; however, the ICL again spontaneously rotated 20 degrees clockwise after re-alignment. Right eye ICL exchange with one size larger lens was planned. On POD 1 after ICL exchange, the uncorrected distance visual acuity (UDVA) was 20/20, with the toric ICL precisely aligned along the target axis and vault of 744 microns. At 6 weeks, the patient presented with similar complaints in the fellow eye with spontaneous ICL rotation of 90 degrees, which also required an ICL exchange with one size larger lens. At 3 months after exchange, bilateral ICL were stable, well aligned along the target axis with UDVA of 20/20 OU and optimal vault.
- 30 January 2025
- Published by Wolters Kluwer Health in Indian Journal of Ophthalmology - Case Reports
- Vol. 5 (1) , 3-5
Open AccessSuccessful management of bilateral spontaneous delayed rotation of toric phakic intraocular lens
A young male in 20s underwent bilateral toric implantable collamer lens (ICL) implantation. The patient presented with diminution of vision in the right eye on postoperative day (POD) 7. On examination, a spontaneous ICL rotation of 90 degrees was observed, with vault of 677 microns. Re-alignment of ICL was performed; however, the ICL again spontaneously rotated 20 degrees clockwise after re-alignment. Right eye ICL exchange with one size larger lens was planned. On POD 1 after ICL exchange, the uncorrected distance visual acuity (UDVA) was 20/20, with the toric ICL precisely aligned along the target axis and vault of 744 microns. At 6 weeks, the patient presented with similar complaints in the fellow eye with spontaneous ICL rotation of 90 degrees, which also required an ICL exchange with one size larger lens. At 3 months after exchange, bilateral ICL were stable, well aligned along the target axis with UDVA of 20/20 OU and optimal vault.