Xiaojie Ai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Xiaojie Ai has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Anzhu Gao
Shanghai Jiao Tong University
7 shared publications - Weidong Chen
Qiushi Academy for Advanced Studies, Zhejiang University, Hangzhou 310027, China
7 shared publications - Guang-Zhong Yang
Shanghai Key Laboratory of Flexible Medical Robotics, Tongren Hospital, Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China
3 shared publications - Zecai Lin
School of Automation and Intelligent Sensing, Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China
3 shared publications - Ben Q. Li
Washington State University
1 shared publication - Bidan Huang
Tencent Robotics X, Shenzhen, China
1 shared publication
Latest Publications
- Open Access
- 22 November 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (47) , eadr6428
Submillimeter fiber robots capable of decoupled macro-micro motion for endoluminal manipulation
Endoluminal and endocavitary intervention via natural orifices of the body is an emerging trend in medicine, further underpinning the future of early intervention and precision surgery. This motivates the development of small continuum robots to navigate freely in confined and tortuous environment. The trade-off between a large range of motion and high precision with concomitant actuation cross-talk poses a major challenge. Here, we present a submillimeter-scale fiber robot (~1 mm) capable of decoupled macro and micro manipulations for intervention and operation. The thin optical fibers, working both as mechanical tendons and light waveguides, can be pulled/pushed to actuate the macro tendon-driven continuum robot and transmit light to actuate the liquid crystal elastomer–based micro built-in light-driven parallel robot. The combination of the decoupled macro and micro motions can accomplish accurate cross-scale motion from several millimeters down to tens of micrometers. In vivo animal studies are performed to demonstrate its positioning accuracy of precise micro operations in endoluminal or endocavitary intervention.
- 22 November 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (47) , eadr6428
Open AccessSubmillimeter fiber robots capable of decoupled macro-micro motion for endoluminal manipulation
Endoluminal and endocavitary intervention via natural orifices of the body is an emerging trend in medicine, further underpinning the future of early intervention and precision surgery. This motivates the development of small continuum robots to navigate freely in confined and tortuous environment. The trade-off between a large range of motion and high precision with concomitant actuation cross-talk poses a major challenge. Here, we present a submillimeter-scale fiber robot (~1 mm) capable of decoupled macro and micro manipulations for intervention and operation. The thin optical fibers, working both as mechanical tendons and light waveguides, can be pulled/pushed to actuate the macro tendon-driven continuum robot and transmit light to actuate the liquid crystal elastomer–based micro built-in light-driven parallel robot. The combination of the decoupled macro and micro motions can accomplish accurate cross-scale motion from several millimeters down to tens of micrometers. In vivo animal studies are performed to demonstrate its positioning accuracy of precise micro operations in endoluminal or endocavitary intervention.
- 1 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (6) , 5679-5686
Dexterity Comparison and Analysis of Multi-Contact-Aided Continuum Manipulators
Continuum robots are being increasingly used in minimally invasive surgery because of their high dexterity. Most studies have adopted the redundancy approach–increase the number of actuation Degrees of Freedom (DOFs)–to improve the performance of robots. However, a continuum robot with a large number of actuation DOFs will feature a complex structure and necessitate sophisticated motion control. This letter uses the multi-contact-aided (MCA) concept to increase the dexterity of continuum robots. Based on the structure and kinematic model of the MCA robot (MCAR), the dexterity of MCARs with different height profiles and DOFs is analyzed and compared. By means of contact blocks arrangement and increased DOFs, we achieve the dexterity enhancement of the MCAR compared to the constant curvature robot (CCR) under the same workspace. Then, we investigate the rationale of dexterity improvement of MCAR with different height profiles. The design optimization of MCRA with nondecreasing workspace is also conducted to achieve the maximal total dexterity over the workspace. Simulation results reveal that the total dexterity of the optimized MCAR is 3.82 times than that of the CCR, the maximum single-point dexterity of the optimized MCAR is 3.57 times than that of the CCR. Finally, experiments are conducted to validate the dexterity of the optimized MCAR, and a phantom study is performed to highlight the clinical superiority of the MCRA.
- 1 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (6) , 5679-5686
Dexterity Comparison and Analysis of Multi-Contact-Aided Continuum Manipulators
Continuum robots are being increasingly used in minimally invasive surgery because of their high dexterity. Most studies have adopted the redundancy approach–increase the number of actuation Degrees of Freedom (DOFs)–to improve the performance of robots. However, a continuum robot with a large number of actuation DOFs will feature a complex structure and necessitate sophisticated motion control. This letter uses the multi-contact-aided (MCA) concept to increase the dexterity of continuum robots. Based on the structure and kinematic model of the MCA robot (MCAR), the dexterity of MCARs with different height profiles and DOFs is analyzed and compared. By means of contact blocks arrangement and increased DOFs, we achieve the dexterity enhancement of the MCAR compared to the constant curvature robot (CCR) under the same workspace. Then, we investigate the rationale of dexterity improvement of MCAR with different height profiles. The design optimization of MCRA with nondecreasing workspace is also conducted to achieve the maximal total dexterity over the workspace. Simulation results reveal that the total dexterity of the optimized MCAR is 3.82 times than that of the CCR, the maximum single-point dexterity of the optimized MCAR is 3.57 times than that of the CCR. Finally, experiments are conducted to validate the dexterity of the optimized MCAR, and a phantom study is performed to highlight the clinical superiority of the MCRA.
- 14 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (2) , 498-511
A Steerable Cross-Axis Notched Continuum Manipulator for Endobronchial Intervention
Achieving the balance between stiffness and range of motion (ROM) in continuum manipulators is a primary design challenge. To tackle this design trade-off, this paper introduces a novel notched-tube continuum manipulator (NTCM) called the Steerable Cross-axis Notched (SCAN) manipulator. It achieves this by integrating asymmetric cross-axis notches into a pair of concentric nitinol tubes. Two pairs of cross-tilted beams are positioned within each segment, thereby extending the length of the flexural members. When compared to traditional NTCM with vertically configured beams (termed as v-NTCM), the SCAN manipulator (SCANM) exhibits a greater maximum bending angle for the same level of bending stiffness. Furthermore, the SCANM exhibits greater bending stiffness in comparison to the v-NTCM with the same maximum bending angle. Subsequently, a mechanical model for the SCANM, accounting for external tip load and tendon friction, is developed. Additionally, a multi-objective optimization is carried out to identify the optimal structural performance. Through model analysis and comparisons, this paper also elucidates the distinct advantages offered by the SCANM. Model verification experiments and stiffness testing experiments are conducted to quantify both the model’s accuracy and stiffness of the SCANM. Finally, an endobronchial grasping and a laser ablation experiment are conducted to demonstrate the practical feasibility of the SCANM for clinical applications.
- 14 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (2) , 498-511
A Steerable Cross-Axis Notched Continuum Manipulator for Endobronchial Intervention
Achieving the balance between stiffness and range of motion (ROM) in continuum manipulators is a primary design challenge. To tackle this design trade-off, this paper introduces a novel notched-tube continuum manipulator (NTCM) called the Steerable Cross-axis Notched (SCAN) manipulator. It achieves this by integrating asymmetric cross-axis notches into a pair of concentric nitinol tubes. Two pairs of cross-tilted beams are positioned within each segment, thereby extending the length of the flexural members. When compared to traditional NTCM with vertically configured beams (termed as v-NTCM), the SCAN manipulator (SCANM) exhibits a greater maximum bending angle for the same level of bending stiffness. Furthermore, the SCANM exhibits greater bending stiffness in comparison to the v-NTCM with the same maximum bending angle. Subsequently, a mechanical model for the SCANM, accounting for external tip load and tendon friction, is developed. Additionally, a multi-objective optimization is carried out to identify the optimal structural performance. Through model analysis and comparisons, this paper also elucidates the distinct advantages offered by the SCANM. Model verification experiments and stiffness testing experiments are conducted to quantify both the model’s accuracy and stiffness of the SCANM. Finally, an endobronchial grasping and a laser ablation experiment are conducted to demonstrate the practical feasibility of the SCANM for clinical applications.
- 15 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 40 (15523098) , 1492-1508
Body Contact Estimation of Continuum Robots With Tension-Profile Sensing of Actuation Fibers
Cable-driven continuum robots are widely used for endoluminal intervention because of their dexterity and shape conforming steerability. However, body contact between the continuum robot and its surrounding anatomy is unavoidable, which imposes a potential safety risk, including vessel wall damage or even perforation. This article presents an approach for body contact estimation of continuum robots with tension-profile sensing of actuation fibers. First, tension-sensing optical fibers with multiple inscribed fiber Bragg grating sensors are used for both actuation and in-situ sensing of the continuum robot. Second, a beam theory-based mechanical model considering segmental differences, multiple fiber interactions, and external force interactions is established, followed by robust estimation of contact positions and forces. Finally, detailed simulations are conducted to validate the accuracy and effectiveness of the proposed method. Experiments on a notched continuum robot are carried out, and the results show that the proposed approach can effectively recover in-situ segmental actuation forces without the need of explicit modeling of the friction between the fibers and guiding channels. The method enables the estimation of the number of contact points, as well as contact positions and contact forces along the body of the continuum robot.
- 15 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 40 (15523098) , 1492-1508
Body Contact Estimation of Continuum Robots With Tension-Profile Sensing of Actuation Fibers
Cable-driven continuum robots are widely used for endoluminal intervention because of their dexterity and shape conforming steerability. However, body contact between the continuum robot and its surrounding anatomy is unavoidable, which imposes a potential safety risk, including vessel wall damage or even perforation. This article presents an approach for body contact estimation of continuum robots with tension-profile sensing of actuation fibers. First, tension-sensing optical fibers with multiple inscribed fiber Bragg grating sensors are used for both actuation and in-situ sensing of the continuum robot. Second, a beam theory-based mechanical model considering segmental differences, multiple fiber interactions, and external force interactions is established, followed by robust estimation of contact positions and forces. Finally, detailed simulations are conducted to validate the accuracy and effectiveness of the proposed method. Experiments on a notched continuum robot are carried out, and the results show that the proposed approach can effectively recover in-situ segmental actuation forces without the need of explicit modeling of the friction between the fibers and guiding channels. The method enables the estimation of the number of contact points, as well as contact positions and contact forces along the body of the continuum robot.
- 31 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (1) , 84-95
Anatomy-Specific Optimization of a Multi-Contact-Aided Continuum Manipulator
Surgical endoscopes deployable through natural orifices are necessary to facilitate further reduction in invasiveness. However, the constant curvature deflection shapes of conventional instruments may result in tissue damage while navigating narrow tortuous variable curvature anatomy. A multi-contact-aided (MCA) continuum manipulator comprising spatial anisotropic bending shapes was developed previously. In this paper, an efficient numerical solution of the inverse kinematics considering variable joint limitations for real-time motion planning is proposed. Then, an anatomy-specific design optimization framework of the MCA continuum manipulator is also proposed to lower intraoperative injury further. Structure parameters optimization is implemented to obtain the most similar shape to the anatomical airways. The optimized single-section MCA continuum manipulator is capable of executing "path-following" motion in three dimensional airways with minimal path deviation. Simulated and experimental deployments toward targeted bronchus are conducted to validate the feasibility of the optimization framework of the MCA continuum manipulator. Consequently, the endobronchial intervention experiments over the targeted airway indicate a mean tip deviation error of 6.2% with respect to manipulator length.
- 31 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (1) , 84-95
Anatomy-Specific Optimization of a Multi-Contact-Aided Continuum Manipulator
Surgical endoscopes deployable through natural orifices are necessary to facilitate further reduction in invasiveness. However, the constant curvature deflection shapes of conventional instruments may result in tissue damage while navigating narrow tortuous variable curvature anatomy. A multi-contact-aided (MCA) continuum manipulator comprising spatial anisotropic bending shapes was developed previously. In this paper, an efficient numerical solution of the inverse kinematics considering variable joint limitations for real-time motion planning is proposed. Then, an anatomy-specific design optimization framework of the MCA continuum manipulator is also proposed to lower intraoperative injury further. Structure parameters optimization is implemented to obtain the most similar shape to the anatomical airways. The optimized single-section MCA continuum manipulator is capable of executing "path-following" motion in three dimensional airways with minimal path deviation. Simulated and experimental deployments toward targeted bronchus are conducted to validate the feasibility of the optimization framework of the MCA continuum manipulator. Consequently, the endobronchial intervention experiments over the targeted airway indicate a mean tip deviation error of 6.2% with respect to manipulator length.
- 21 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 27 (5) , 3144-3154
ARei: Augmented-Reality-Assisted Touchless Teleoperated Robot for Endoluminal Intervention
Current robotic endoluminal interventions require surgeons to hold a proximal joystick to control the distal flexible robot under 2-D X-ray guidance. However, the 2-D X-ray image is not intuitive, which not only increases the risk of surgical misoperation but also the workload of surgeons. Moreover, contact teleoperation exposes surgeons to the potentially infectious environment. To address it, this article proposes an augmented-reality-assisted touchless teleoperated robot for endoluminal intervention, called ARei. It aims to provide immersive experiences with augmented information. The robot integrates perceptual information obtained from an electromagnetic (EM) sensor, a shape sensor, and the virtual anatomy into a head-mounted display (HMD). The touchless teleoperation is used to control the robot, with the assistance of gesture recognition technology. Results show that the mean error of the calibration between the HMD and the EM tracking system is 4.67 mm, and the mean distance error between the points measured by the EM sensor and the points obtained by shape reconstruction with calibration is 5.19 mm (3.05%).
- 21 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 27 (5) , 3144-3154
ARei: Augmented-Reality-Assisted Touchless Teleoperated Robot for Endoluminal Intervention
Current robotic endoluminal interventions require surgeons to hold a proximal joystick to control the distal flexible robot under 2-D X-ray guidance. However, the 2-D X-ray image is not intuitive, which not only increases the risk of surgical misoperation but also the workload of surgeons. Moreover, contact teleoperation exposes surgeons to the potentially infectious environment. To address it, this article proposes an augmented-reality-assisted touchless teleoperated robot for endoluminal intervention, called ARei. It aims to provide immersive experiences with augmented information. The robot integrates perceptual information obtained from an electromagnetic (EM) sensor, a shape sensor, and the virtual anatomy into a head-mounted display (HMD). The touchless teleoperation is used to control the robot, with the assistance of gesture recognition technology. Results show that the mean error of the calibration between the HMD and the EM tracking system is 4.67 mm, and the mean distance error between the points measured by the EM sensor and the points obtained by shape reconstruction with calibration is 5.19 mm (3.05%).
- 24 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (3) , 4560-4567
A Multi-Contact-Aided Continuum Manipulator With Anisotropic Shapes
Cable-driven continuum manipulators have shown excellent benefits to work for endoluminal intervention. Demand of small diameter for confined anatomy limits the usage of multiple actuations, leading to limited DOFs and bending shapes. To address this problem, this letter proposes a multi-contact-aided continuum manipulator with anisotropic bending shapes. First, contact-aided compliant mechanisms (CCMs) are configured at different locations to introduce the specific constraints to enable the anisotropy. Then, the forward and inverse kinematic models considering contact blocks are built. The reachable workspace of the continuum manipulator is given, and simulation cases are studied to demonstrate the superiority of the proposed manipulator. Finally, a 3D-printed physical prototype is fabricated, and preliminary experiments are conducted to evaluate the model accuracy. Results show an average shape error of 1.98 mm (4.2%) and a maximum of 3.58 mm (7.6%). A robotic bronchoscopy platform integrated with the continuum manipulator is developed to conduct the airway phantom experiments. The shape deviation of the proposed manipulator from the centerline of the bronchus is 31.8% smaller than that of the constant curvature manipulator. The experiments validate the system-level feasibility and effectiveness of the developed continuum manipulator.
- 24 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (3) , 4560-4567
A Multi-Contact-Aided Continuum Manipulator With Anisotropic Shapes
Cable-driven continuum manipulators have shown excellent benefits to work for endoluminal intervention. Demand of small diameter for confined anatomy limits the usage of multiple actuations, leading to limited DOFs and bending shapes. To address this problem, this letter proposes a multi-contact-aided continuum manipulator with anisotropic bending shapes. First, contact-aided compliant mechanisms (CCMs) are configured at different locations to introduce the specific constraints to enable the anisotropy. Then, the forward and inverse kinematic models considering contact blocks are built. The reachable workspace of the continuum manipulator is given, and simulation cases are studied to demonstrate the superiority of the proposed manipulator. Finally, a 3D-printed physical prototype is fabricated, and preliminary experiments are conducted to evaluate the model accuracy. Results show an average shape error of 1.98 mm (4.2%) and a maximum of 3.58 mm (7.6%). A robotic bronchoscopy platform integrated with the continuum manipulator is developed to conduct the airway phantom experiments. The shape deviation of the proposed manipulator from the centerline of the bronchus is 31.8% smaller than that of the constant curvature manipulator. The experiments validate the system-level feasibility and effectiveness of the developed continuum manipulator.
- 10 November 2001
- Published by ASME International
- p. 131-140
A Parallel HOFD Scheme for Direct Numerical Simulation of Turbulent Magnetically Driven Flows
Turbulent magnetically flows occur in a wide range of material processing systems involving electrically conducting melts. This paper presents a parallel higher order scheme for the direct numerical simulation of turbulent magnetically driven flows in induction channels. The numerical method is based on the higher order finite difference algorithm, which enjoys the spectral accuracy while minimizing the computational intensity. This, coupled with the parallel computing strategy, provides a very useful means to simulate turbulent flows. The higher order finite difference formulation of magnetically driven flow problems is described in this paper. The details of the parallel algorithm and its implementation for the simulations on parallel machines are discussed. The accuracy and numerical performance of the higher order finite difference scheme are assessed in comparison with the spectral method. The examples of turbulent magnetically driven flows in induction channels and pressure gradient driven flows in regular channels are given, and the computed results are compared with experimental measurements wherever possible.
- 10 November 2001
- Published by ASME International
- p. 131-140
A Parallel HOFD Scheme for Direct Numerical Simulation of Turbulent Magnetically Driven Flows
Turbulent magnetically flows occur in a wide range of material processing systems involving electrically conducting melts. This paper presents a parallel higher order scheme for the direct numerical simulation of turbulent magnetically driven flows in induction channels. The numerical method is based on the higher order finite difference algorithm, which enjoys the spectral accuracy while minimizing the computational intensity. This, coupled with the parallel computing strategy, provides a very useful means to simulate turbulent flows. The higher order finite difference formulation of magnetically driven flow problems is described in this paper. The details of the parallel algorithm and its implementation for the simulations on parallel machines are discussed. The accuracy and numerical performance of the higher order finite difference scheme are assessed in comparison with the spectral method. The examples of turbulent magnetically driven flows in induction channels and pressure gradient driven flows in regular channels are given, and the computed results are compared with experimental measurements wherever possible.