RZRuiyun Zhu

Ruiyun Zhu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ruiyun Zhu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Semi-supervised Tubular Structure Segmentation with Cross Geometry and Hausdorff Distance Consistency

    by Ruiyun Zhu, Masahiro Oda, Yuichiro Hayashi, Takayuki Kitasaka, Kensaku Mori


  • Open Access

    Skeleton-guided 3D convolutional neural network for tubular structure segmentation

    by Ruiyun Zhu, Masahiro Oda, Yuichiro Hayashi, Takayuki Kitasaka, Kazunari Misawa, Michitaka Fujiwara, Kensaku Mori

    Purpose: Accurate segmentation of tubular structures is crucial for clinical diagnosis and treatment but is challenging due to their complex branching structures and volume imbalance. The purpose of this study is to propose a 3D deep learning network that incorporates skeleton information to enhance segmentation accuracy in these tubular structures. Methods: Our approach employs a 3D convolutional network to extract 3D tubular structures from medical images such as CT volumetric images. We introduce a skeleton-guided module that operates on extracted features to capture and preserve the skeleton information in the segmentation results. Additionally, to effectively train our deep model in leveraging skeleton information, we propose a sigmoid-adaptive Tversky loss function which is specifically designed for skeleton segmentation. Results: We conducted experiments on two distinct 3D medical image datasets. The first dataset consisted of 90 cases of chest CT volumetric images, while the second dataset comprised 35 cases of abdominal CT volumetric images. Comparative analysis with previous segmentation approaches demonstrated the superior performance of our method. For the airway segmentation task, our method achieved an average tree length rate of 93.0%, a branch detection rate of 91.5%, and a precision rate of 90.0%. In the case of abdominal artery segmentation, our method attained an average precision rate of 97.7%, a recall rate of 91.7%, and an F-measure of 94.6%. Conclusion: We present a skeleton-guided 3D convolutional network to segment tubular structures from 3D medical images. Our skeleton-guided 3D convolutional network could effectively segment small tubular structures, outperforming previous methods.


  • A skeleton context-aware 3D fully convolutional network for abdominal artery segmentation

    by Ruiyun Zhu, Masahiro Oda, Yuichiro Hayashi, Takayuki Kitasaka, Kazunari Misawa, Michitaka Fujiwara, Kensaku Mori

    Purpose This paper aims to propose a deep learning-based method for abdominal artery segmentation. Blood vessel structure information is essential to diagnosis and treatment. Accurate blood vessel segmentation is critical to preoperative planning. Although deep learning-based methods perform well on large organs, segmenting small organs such as blood vessels is challenging due to complicated branching structures and positions. We propose a 3D deep learning network from a skeleton context-aware perspective to improve segmentation accuracy. In addition, we propose a novel 3D patch generation method which could strengthen the structural diversity of a training data set. Method The proposed method segments abdominal arteries from an abdominal computed tomography (CT) volume using a 3D fully convolutional network (FCN). We add two auxiliary tasks to the network to extract the skeleton context of abdominal arteries. In addition, our skeleton-based patch generation (SBPG) method further enables the FCN to segment small arteries. SBPG generates a 3D patch from a CT volume by leveraging artery skeleton information. These methods improve the segmentation accuracies of small arteries. Results We used 20 cases of abdominal CT volumes to evaluate the proposed method. The experimental results showed that our method outperformed previous segmentation accuracies. The averaged precision rate, recall rate, and F-measure were 95.5%, 91.0%, and 93.2%, respectively. Compared to a baseline method, our method improved 1.5% the averaged recall rate and 0.7% the averaged F-measure. Conclusions We present a skeleton context-aware 3D FCN to segment abdominal arteries from an abdominal CT volume. In addition, we propose a 3D patch generation method. Our fully automated method segmented most of the abdominal artery regions. The method produced competitive segmentation performance compared to previous methods.