Jithendar Reddy Mandhadi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jithendar Reddy Mandhadi has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Bhupendra Shrestha
Himalayan Pharmacy Institute, Majhitar, East Sikkim 737136, India
1 shared publication- Biplab Kumar Dey
Faculty of Pharmaceutical Science, Assam Down Town University, Guwahati, Assam, India
1 shared publication - Faruk Alam
Faculty of Pharmaceutical Science, Assam down town University, Sankar Madhab Path, Gandhi Nagar, Panikhaiti, Guwahati, Assam, 781026, India
1 shared publication - Mayeen Uddin Khandaker
Sunway University
1 shared publication - Ruhul Amin
Faculty of Pharmaceutical Science, Assam down town University, Panikhaiti, Gandhinagar, Guwahati, Assam, India
1 shared publication - Sher Zaman Safi
Faculty of Medicine, Bioscience and Nursing, MAHSA University, Jenjarom, Malaysia
1 shared publication
Latest Publications
- Open Access
- 30 June 2025
- Published by Creative Pharma Assent in Journal of Applied Pharmaceutical Research
- Vol. 13 (3) , 154-163
Spectrophotometric methods for determination of naringin, amlodipine, and nifedipine using chemometric techniques
Background: Chemometrics articulates statistical and mathematical aspects to analyse the effectiveness of chemical data, playing a pivotal role in spectroscopy. Among all the chemometrics techniques, this study utilizes the Orthogonal partial least squares (OPLS) model for the simultaneous analysis of naringin, amlodipine, and nifedipine, a well-established calcium channel blocker. Naringin, a citrus flavonoid exhibiting notable pharmacological activities. Methodology: This research employs UV-visible spectrophotometry in conjunction with the OPLS method for both calibration and prediction sets in simultaneous studies of Amlodipine–Naringin and Nifedipine–Naringin, aiming to develop a precise model for measuring drug concentrations. A linear dynamic range of 5-20 µg/mL was achieved for standard solutions, while calibration sets were developed using factorial designs. Result and Discussion: The OPLS model had significant predictive performance with R2 values within the range of 0.9947-0.9976 for calibration and 0.9947-0.9985 for prediction, and low root mean square error of cross validation (RMSECV) values of 0.6191- 0.4353 for NIF-NAR, and 0.3978- 0.4418 for AML-NAR, indicating robust model performance. The model validation process, using Hotelling’s T2 test, DModx, established no significant outliers, and permutation analysis validated the model’s reliable fit. The recovery studies showed values close to 100%, thus verifying the effectiveness of the methodology. Conclusion: The research demonstrated OPLS (Orthogonal Partial Least Squares) as a powerful solution for resolving overlapping spectral data, providing high-precision drug analysis with minimal interference. The development of chemometrics methods demonstrated efficiency and precision in pharmaceutical analysis while also offering cost-effectiveness for quality control and formulation development.
- 30 June 2025
- Published by Creative Pharma Assent in Journal of Applied Pharmaceutical Research
- Vol. 13 (3) , 154-163
Open AccessSpectrophotometric methods for determination of naringin, amlodipine, and nifedipine using chemometric techniques
Background: Chemometrics articulates statistical and mathematical aspects to analyse the effectiveness of chemical data, playing a pivotal role in spectroscopy. Among all the chemometrics techniques, this study utilizes the Orthogonal partial least squares (OPLS) model for the simultaneous analysis of naringin, amlodipine, and nifedipine, a well-established calcium channel blocker. Naringin, a citrus flavonoid exhibiting notable pharmacological activities. Methodology: This research employs UV-visible spectrophotometry in conjunction with the OPLS method for both calibration and prediction sets in simultaneous studies of Amlodipine–Naringin and Nifedipine–Naringin, aiming to develop a precise model for measuring drug concentrations. A linear dynamic range of 5-20 µg/mL was achieved for standard solutions, while calibration sets were developed using factorial designs. Result and Discussion: The OPLS model had significant predictive performance with R2 values within the range of 0.9947-0.9976 for calibration and 0.9947-0.9985 for prediction, and low root mean square error of cross validation (RMSECV) values of 0.6191- 0.4353 for NIF-NAR, and 0.3978- 0.4418 for AML-NAR, indicating robust model performance. The model validation process, using Hotelling’s T2 test, DModx, established no significant outliers, and permutation analysis validated the model’s reliable fit. The recovery studies showed values close to 100%, thus verifying the effectiveness of the methodology. Conclusion: The research demonstrated OPLS (Orthogonal Partial Least Squares) as a powerful solution for resolving overlapping spectral data, providing high-precision drug analysis with minimal interference. The development of chemometrics methods demonstrated efficiency and precision in pharmaceutical analysis while also offering cost-effectiveness for quality control and formulation development.
- Open Access
- 24 October 2022
- Published by MDPI AG in Separations
- Vol. 9 (11) , 326
Multidimensional Chromatography and Its Applications in Food Products, Biological Samples and Toxin Products: A Comprehensive Review
Food, drugs, dyes, extracts, and minerals are all made up of complex elements, and utilizing unidimensional chromatography to separate them is inefficient and insensitive. This has sparked the invention of several linked chromatography methods, each of them with distinct separation principles and affinity for the analyte of interest. Multidimensional chromatography consists of the combination of multiple chromatography techniques, with great benefits at the level of efficiency, peak capacity, precision, and accuracy of the analysis, while reducing the time required for the analysis. Various coupled chromatography techniques have recently emerged, including liquid chromatography–gas chromatography (LC–GC), gas chromatography–gas chromatography (GC–GC), liquid chromatography–liquid chromatography (LC–LC), GCMS–MS, LCMS–MS, supercritical fluid techniques with chromatography techniques, and electro-driven multidimensional separation techniques. In this paper, the different coupled chromatography techniques will be discussed, along with their wide spectrum of applications for food, flavor, and environmental analysis, as well as their usefulness for the pharmaceutical, color, and dyes industries.
- 24 October 2022
- Published by MDPI AG in Separations
- Vol. 9 (11) , 326
Open AccessMultidimensional Chromatography and Its Applications in Food Products, Biological Samples and Toxin Products: A Comprehensive Review
Food, drugs, dyes, extracts, and minerals are all made up of complex elements, and utilizing unidimensional chromatography to separate them is inefficient and insensitive. This has sparked the invention of several linked chromatography methods, each of them with distinct separation principles and affinity for the analyte of interest. Multidimensional chromatography consists of the combination of multiple chromatography techniques, with great benefits at the level of efficiency, peak capacity, precision, and accuracy of the analysis, while reducing the time required for the analysis. Various coupled chromatography techniques have recently emerged, including liquid chromatography–gas chromatography (LC–GC), gas chromatography–gas chromatography (GC–GC), liquid chromatography–liquid chromatography (LC–LC), GCMS–MS, LCMS–MS, supercritical fluid techniques with chromatography techniques, and electro-driven multidimensional separation techniques. In this paper, the different coupled chromatography techniques will be discussed, along with their wide spectrum of applications for food, flavor, and environmental analysis, as well as their usefulness for the pharmaceutical, color, and dyes industries.