Manatsaphon Sukmak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Manatsaphon Sukmak has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Sirirat Anutrakulchai
Division of Nephrology, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand
2 shared publications - Ubon Cha’on
Department of Biochemistry, Faculty of Medicine, Khon Kaen University, Khon Kaen 40002, Thailand
2 shared publications - Amod Sharma
Department of Pharmacology and Toxicology, University of Arkansas for Medical Sciences, Little Rock, AR 72205, USA
1 shared publication - Atit Silsirivanit
Department of Biochemistry, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand
1 shared publication - Bruce D. Hammock
Department of Entomology and Nematology and UC Davis Comprehensive Cancer Center
1 shared publication - Carlo Selmi
Rheumatology and Clinical Immunology, IRCCS Humanitas Research Hospital, Rozzano, Italy
1 shared publication
Latest Publications
- Open Access
- 24 October 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (11) , 915
Effects of Boric Acid and Storage Temperature on the Analysis of Microalbumin Using Aptasensor-Based Fluorescent Detection
The instability of human serum albumin (HSA) in urine samples makes fresh urine a requirement for microalbumin analyses using immunoturbidimetry. Here, we determined the ability of an aptasensor-based fluorescent platform to detect microalbumin in old, boric acid-preserved urine samples. Our results show that the cleavage site of protease enzymes on urine albumin protein differed from the binding position of the aptamer on HSA protein, suggesting the aptasensor may be effective for albumin detection in non-fresh urine. Furthermore, the addition of boric acid in urine samples over a short term (at ambient temperature (Ta) and 4 °C), long term (−20 and −80 °C), and following freeze–thawing (1–3 cycles) did not significantly affect albumin stability, as analyzed using the aptasensor. Therefore, boric acid stabilized has in urine stored over a short- and long-term. Thus, the aptasensor developed by us is applicable for HSA detection in boric acid-preserved urine that has been stored for 7-d at Ta and 4 °C, and in the long-term at −80 °C.
- 24 October 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (11) , 915
Open AccessEffects of Boric Acid and Storage Temperature on the Analysis of Microalbumin Using Aptasensor-Based Fluorescent Detection
The instability of human serum albumin (HSA) in urine samples makes fresh urine a requirement for microalbumin analyses using immunoturbidimetry. Here, we determined the ability of an aptasensor-based fluorescent platform to detect microalbumin in old, boric acid-preserved urine samples. Our results show that the cleavage site of protease enzymes on urine albumin protein differed from the binding position of the aptamer on HSA protein, suggesting the aptasensor may be effective for albumin detection in non-fresh urine. Furthermore, the addition of boric acid in urine samples over a short term (at ambient temperature (Ta) and 4 °C), long term (−20 and −80 °C), and following freeze–thawing (1–3 cycles) did not significantly affect albumin stability, as analyzed using the aptasensor. Therefore, boric acid stabilized has in urine stored over a short- and long-term. Thus, the aptasensor developed by us is applicable for HSA detection in boric acid-preserved urine that has been stored for 7-d at Ta and 4 °C, and in the long-term at −80 °C.
- 14 September 2022
- Published by Elsevier in Biochemical and Biophysical Research Communications
- Vol. 630, 158-166
Monosodium glutamate consumption reduces the renal excretion of trimethylamine N-oxide and the abundance of Akkermansia muciniphila in the gut
- 14 September 2022
- Published by Elsevier in Biochemical and Biophysical Research Communications
- Vol. 630, 158-166
Monosodium glutamate consumption reduces the renal excretion of trimethylamine N-oxide and the abundance of Akkermansia muciniphila in the gut