ADAdam Deller

Adam Deller

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Adam Deller has a total of 178 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Rydberg positronium injection of electrons and positrons into a levitated dipole trap

    by A. Deller

    A neutral-beam injection scheme for magnetically trapping electrons and positrons is proposed. Pulsed lasers excite positronium (Ps) to long-lived Rydberg states that drift at speeds of $$|\vec {v}| \sim 10^5$$ | v → | ∼ 10 5 $$\textrm{m} \, \textrm{s}^{-1}$$ m s - 1 into the magnetic field of a levitated superconducting coil. The electric field experienced in the reference frame of the rapidly moving atoms is sufficient to ionize a significant portion of the loosely bound Ps. The released electrons and positrons are confined to the poloidal magnetic field lines that wrap around the coil. Rydberg positronium injection (RPI) does not perturb the confinement volume and ensures local charge symmetry. The technique provides equal, low temperatures for the electron and positron distributions, as well as smooth, inwardly peaked density profiles. The range of populated field lines depends on the Ps velocity distribution and the ionization threshold of the Rydberg state. Monte Carlo simulations are used to evaluate the $$e^+$$ e + efficiency of RPI for the APEX (A Positron–Electron eXperiment) levitated dipole.

  • Open Access

    Motional dynamics of Rydberg NO molecules in a transmission-line Rydberg-Stark decelerator

    by A. Deller, M. H. Rayment, S. D. Hogan

    1. Rydberg states of small molecules, with high principal quantum number n, are of importance in areas ranging from studies of plasma dynamics [1–4] to precision tests of quantum chemical calculati...

  • Open Access

    Positron transport and cooling with CF 4 in an inhomogeneous magnetic field

    by J. von der Linden, A. Deller, S. Nißl, K. Michishio, H. Higaki, E. V. Stenson

    We present measurements of positrons ( e + ) undergoing transport and cooling with molecular CF 4 in the inhomogeneous magnetic field of a dipole trap. The annihilation rate and γ -ray spectra reveal a shift in the primary loss channel from positronium (Ps) formation to collisional cross-field transport. This transition is mediated by molecules cooling e + below the charge-exchange threshold for Ps formation. Elucidating the interplay between cooling and annihilation is crucial for optimizing e + confinement schemes and refining models of astrophysical γ -ray spectra.

  • Open Access

    Pure electron plasmas in a compact levitated dipole trap

    by A. Deller, V. C. Bayer, A. Card, P. Steinbrunner, M. R. Stoneking, E. V. Stenson

    We present measurements of pure electron plasmas in the APEX (A Positron Electron eXperiment) levitated dipole trap. The electrons are confined by the magnetic field generated by a persistent current flowing in a magnetically suspended high-temperature-superconducting coil. A pulsed thermionic emitter fills the ultra-high vacuum trap with electrons. Large-amplitude, narrow-band oscillations in the region of f0∼50 kHz are consistently observed in wall probe measurements after the fill. The toroidally propagating ℓ=1 mode is typically stable for ∼1 s. Longer hold times generally exhibit a series of upward chirps in a similar frequency range. An electron beam probe provides time-resolved measurements of the electric potential along the axis of symmetry of the dipole field. We employ this diagnostic to estimate the charge on the coil and the surrounding electron density distribution.

  • Open Access

    Design and operation of APEX-LD: A compact levitated dipole for a positron–electron experiment

    by A. Card, M. R. Stoneking, A. Deller, E. V. Stenson

    The objective of the APEX (A Positron–Electron eXperiment) project is to magnetically confine and study positron–electron pair plasmas. For this purpose, a levitated dipole trap (APEX-LD) has been constructed. The magnetically levitated, compact (7.5-cm radius), closed-loop, high-temperature superconducting floating (F-)coil consists exclusively of a no-insulation rare-earth barium copper oxide winding pack, solder-potted in a gold-plated-copper case. A resealable in-vacuum cryostat facilitates cooling (via helium gas) and inductive charging of the F-coil. The 70-min preparation cycle reliably generates persistent currents of ∼60 kA-turns and an axial magnetic flux density of B0 ≈ 0.5 T. We demonstrate levitation times in excess of 3 h with a vertical stability of σz < 20 μm. Despite being subjected to routine quenches (and occasional mechanical shocks), the F-coil has proven remarkably robust. We present the results of preliminary experiments with electrons and outline the next steps for injecting positron bunches into the device.


  • Open Access

    Diocotron modes in pure electron plasmas in the APEX levitating dipole trap

    by A Deller, V C Bayer, P Steinbrunner, A Card, J R Danielson, M R Stoneking, E V Stenson

    Observations of persistent toroidal modes in dipole-trapped pure electron plasmas are presented. Non-neutral electron plasmas were confined by the poloidal magnetic field of the APEX (A Positron Electron eXperiment) levitating dipole trap. The negative bias of the electron emitter was gated to control the filling time. Large amplitude, narrow-band oscillations were consistently observed in wall probe measurements after the fill. The oscillatory image-charge currents induced by the trapped electron plasma typically persisted for many seconds with fundamental frequencies, f 0 = 50 to 500 kHz, that scale with the E → × B → drift velocity. We attribute this feature to the dipole-equivalent of the diocotron mode that is commonly observed in non-neutral plasmas in linear traps.


  • Open Access

    Injection, confinement, and diagnosis of electrons and positrons in a permanent magnet dipole trap

    by J. von der Linden, S. Nißl, A. Deller, M. Singer, N. Belmore, C. P. Hugenschmidt, T. Sunn Pedersen, H. Saitoh, E. V. Stenson

    Prerequisites for the goal of studying long-lived, magnetically confined, electron–positron pair plasmas in the laboratory include the injection of both species into the trap, long trapping times, and suitable diagnostic methods. Here we report recent progress on these tasks achieved in a simple dipole trap based on a supported permanent magnet. For the injection of electrons, both an $$\textbf{E}\times B$$ E × B drift technique (of a $$\sim $$ ∼ 2– $$\upmu $$ μ A, 6-eV beam) and “edge injection” (from a filament emitting a few mA and biased to some tens of volts) have been demonstrated; the former is suitable for low-density beams with smaller spatial and velocity spreads, while the latter employs fluctuations arising from collective behavior. To diagnose the edge-injected electrons, image potentials and currents induced on a wall probe, the magnet case, and wall electrodes were measured. Confinement of drift-injected positrons, measured experimentally, exhibited at least two well-separated timescales. Simulations reproduced this qualitatively, using a simple model of elastic collisions with residual background gas, and point to small adjustments for increasing trapping times. In a major upgrade to diagnostic capabilities, 25 bismuth germanate detectors, placed in three reentrant ports, are able to localize annihilation gammas, which will be used in future experiments to distinguish between different loss channels. Graphical


  • FPGA-Stabilized Magnetic Levitation of the APEX-LD High-Temperature Superconducting Coil

    by A. Card, A. Deller, M. R. Stoneking, J. von der Linden, E. V. Stenson

    In this article, we demonstrate in-vacuum magnetic levitation of a compact high-temperature superconducting coil, which has been designed for magnetic confinement of an electron–positron pair plasma. The closed no-insulation rare-earth barium copper oxide coil was energized with a persistent current to generate a dipole magnetic field and then magnetically levitated by a water-cooled copper lifting coil located above. The vertical position of the floating coil was measured by an array of laser position sensors. Stable levitation was achieved by continuous adjustment of the lifting coil current using a 1-kHz proportional–integral–derivative feedback loop implemented by a field-programmable gate array. The feedback parameters were optimized with a 1-D simulation of the levitation system. A levitation time in excess of 3 h was achieved with a mean vertical displacement from the set point position of $-\text{3 } \mu \rm {\text{m}}$ and a standard deviation of $\sigma _{z} = \text{18 }\mu \rm {\text{m}}$ .


  • Open Access

    Injection and confinement of positron bunches in a magnetic dipole trap

    by A. Deller, J. von der Linden, S. Nißl, K. Michishio, N. Oshima, H. Higaki, E. V. Stenson

    We demonstrate the efficient injection of a pulsed positron beam into a magnetic dipole trap and investigate the ensuing particle dynamics in the inhomogeneous electric and magnetic fields. Bunches of ∼105e+ were transferred from a buffer-gas trap into the field of a permanent magnet using a lossless E×B drift technique. The Δt≈0.2µs pulses were short compared to the toroidal rotation period, τd≈16µs, and e+ confinement time, τc≈0.6 s. The redistribution dynamics were studied by measuring the delayed γ-ray emission as the trap was emptied. This work extends the record for the number of low-energy positrons held in a dipole trap by two orders of magnitude and represents a significant advance toward the confinement of an electron-positron pair plasma.


  • Open Access

    A buffer-gas trap for the NEPOMUC positron beam: optimization studies with electrons

    by A. Deller, C.W. Rogge, S. Desopo, E.V. Stenson, J.R. Danielson, M.R. Stoneking, C. Hugenschmidt, T. Sunn Pedersen, C.M. Surko

    Buffer-gas traps (BGTs) use inelastic interactions with nitrogen molecules to capture positrons from a continuous beam. These devices are invaluable for high-resolution studies of matter–antimatter interactions, antihydrogen research and positronium laser spectroscopy. We present a new project with the goal of producing a non-neutral plasma containing ${\sim }10^8$ low-energy positrons by installing a BGT on the NEPOMUC (NEutron induced POsitron source MUniCh) high-intensity positron beam. Details of the BGT are outlined and results are presented from experiments in which an electron beam, with a similar intensity and energy spread to the remoderated NEPOMUC beam, was used to create pulses of non-neutral electron plasma. The device is a vital component of the APEX (A Positron Electron eXperiment) project, which aims to create a low-temperature electron–positron pair plasma.